• Title/Summary/Keyword: signal tube

Search Result 318, Processing Time 0.023 seconds

An Experimental Study on the Material Characteristics of Mechanical Filters for Eliminating High-Frequency Noise in Accelerometer Measurements (가속도 측정에 있어 고주파 잡음 제거를 위한 기계적 필터의 재료 특성에 관한 실험적 연구)

  • Choi, Won-Yeong;Yoo, Seong-Yeol;Cha, Ki-Up;Kim, Sung-Soo;Noh, Myoung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.773-778
    • /
    • 2011
  • Accelerometers are widely used to measure the lateral vibrations of pipe-like structures such as a gun tube under impulse loads. Stress waves that precede the lateral vibrations due to the explosion within a gun contribute little to the vibrations, but saturate the accelerometer input. A mechanical filter eliminates this high-frequency stress wave and only transmits the signal corresponding to the lateral vibrations. The mechanical filter consists of a mechanical structure for mounting the accelerometers and a damping material. The low-pass filter characteristics are determined from the equivalent damping and stiffness property of this damping material. In this paper, we tested nine commercially available damping materials for their vibration characteristics by using a test rig. We also observed the change in the vibration characteristics while compressing the material. We designed and manufactured a mechanical filter and verified its filtering performance.

Novel Anti-Angiogenic Activity in Rubus coreanus Miquel Water Extract Suppresses VEGF-Induced Angiogenesis

  • Kim, Eok-Cheon;Kim, Hye Jin;Kim, Tack-Joong
    • Biomedical Science Letters
    • /
    • v.20 no.4
    • /
    • pp.209-220
    • /
    • 2014
  • Vascular endothelial growth factor (VEGF) is a key factor involved in the induction of angiogenesis and has become an attractive target for anti-angiogenesis therapies. The purpose of this study was to elucidate the anti-angiogenic activity of Rubus coreanus Miquel water extract (RCME). Rubus coreanus Miquel has long been employed as a traditional medicine, and recent studies have demonstrated that it has measureable biological activities. Thus, we investigated for the first time the effect of RCME on angiogenesis and its underlying signaling pathways. The effects of RCME were tested on in vitro models of angiogenesis, namely, proliferation, migration, invasion and tube formation of human umbilical vein endothelial cells as well as an ex vivo model of vessel sprouting from the rat aorta in response to VEGF. We observed that VEGF-induced angiogenesis was strongly suppressed by RCME treatment compared to that of the control group. Moreover, we found that RCME inhibited VEGF-induced activation of matrix metalloproteinases and phosphorylation of extracellular signal-regulated kinase and p38, and also effectively inhibited phosphorylation of VEGF receptor 2. These results indicated that RCME inhibits angiogenesis by suppressing phosphorylation of the VEGF receptor and may be useful for the treatment of angiogenesis-dependent diseases such as cancer and diabetic retinopathy.

Detailed Local Chemiluminescence Measurement (OH*, CH* and C2*) and Nitrogen Oxides Emissions in Laminar Partially Premixed CH4/Air Flames (메탄/공기 층류 부분예혼합화염의 상세 라디칼(OH*, CH* 그리고 C2*) 정보와 배기매출물에 관한 실험적 연구)

  • Jeong Yong Ki;Oh Jeong Seog;Jeon Chung Hwan;Chang Young June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.263-270
    • /
    • 2005
  • An experimental study was performed to investigate the effects of partially premixing, varying the equivalence ratios from $0.79{\sim}{\infty}$, on NOx emissions and chemiluminescence of excited $OH^{\ast},\;CH^{ast}\;C_2^{\ast}$ radicals in laminar partially premixed flames. the signal from the electronically excited state of $OH^{\ast},\;CH^{ast}\;C_2^{\ast}$ was detected through a band pass filter with a photo multiplier tube, which are processed to the intensity ratio ($C_2^{\ast}/CH^{\ast},\;C_2^{\ast}/OH^{\ast},\;and\;CH^{\ast}/OH^{\ast}$) to reveal the correlation with local equivalence ratio. And measurements of NOx emission were made to investigate the relationship between visible flame appearance, chemiluminescence, and EINOX. The results demonstrated that (1) the flames at ${\phi}<1.59$ exhibited classical double flame structure, at ${\phi}>4.76$, the flames exhibited diffusion flame structure, and the intermediate flames at $1.59<{\phi}<4.76$ was a merged flame, (2) the $OH^{\ast}$ peak was located inside the $CH^{\ast}\;and\;C_2^{\ast}$ radical for all measured conditions and the emission intensity ratio of $C_2^{\ast}/CH^{\ast}\;and\;C_2^{\ast}/OH^{\ast}$ were identified as good marker for local equivalence ratio over a range of ${\phi}=0.79{\sim}1.2\;and\;CH^{\ast}/OH^{\ast}\;is\;0.79<{\phi}<1.9$. However, it was difficult to predict the equivalence ratio in partially premixed flames using this system for ${\phi}>2.38$, (3) the minimum NOX emission index (EINOx) is obtained for a equivalence ratio of 3.19 in the intermediate flames.

Ring-Shaped Inductive Sensor Design and Application to Pressure Sensing (환형 인덕티브 센서의 설계 및 압력센서로의 적용)

  • Noh, Myounggyu;Kim, Sunyoung;Baek, Seongki;Park, Young-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.10
    • /
    • pp.995-999
    • /
    • 2015
  • Inductive sensors are versatile and economical devices that are widely used to measure a wide variety of physical variables, such as displacement, force, and pressure. In this paper, we propose a simple inductive sensor consisting of a thin partial ring and a coil set. The self-inductance of the sensor was estimated using magnetic circuit analysis and validated through finite element analysis (FEA). The natural frequency of the ring was estimated using Castigliano's theorem and the method of equivalent mass. The estimation was validated through experiments and FEA. A prototype sensor with a signal processing circuit is built and applied to noninvasively sense the pressure inside a flexible tube. The obtained sensor outputs show quadratic behavior with respect to the pressure. When fitted to a quadratic equation, the least-square measurement error was less than 2%. The results confirm the feasibility of pressure sensing using the proposed inductive sensor.

Signal Characteristics of Eddy Current Test for Intergranular Attack of Steam Generator Tubes (증기발생기 전열관의 입계부식에 대한 와전류검사 신호특성)

  • Choi, Myung-Sik;Lee, Deok-Hyun;Cho, Se-Gon;Yim, Chang-Jae;Han, Jung-Ho;Hur, Do-Haeng
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.198-202
    • /
    • 2002
  • Beacuse intergranular attack (IGA), one of the locallized corrosion forms occurring on steam generator tubes, can not be fabricated by an electric discharge machining method, there are few data for the eddy current test (ECT) characteristics of IGA. In this paper, the characteristics of eddy current signals are evaluated using nonexpanded tubes with IGA defects formed in 0.1 M sodium tetrathionate solution at $40^{\circ}C$. The detectability and sizing accuracy of IGA were discussed in terms of the coil type and frequency of the ECT probes.

A Study of the Diffusion and Rise of Stack Plumes at Coastal Region by Using LIDAR Observation Data

  • Yoon, Ill-Hee
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • v.26 no.1
    • /
    • pp.43-58
    • /
    • 1998
  • The Kwinana Shoreline Fumigation Experiment (KSFE) took place at Fremantle, WA, Australia between January 23 and February 8, 1995. The CSIRO DAR LIDAR measured plume sections from near the Kwinana Power Station (KPS) stacks to up to about 5 km downstream. It also measured boundary layer aerosols and the structure of the boundary layer on some occasions. Both stages A and C of KPS were used as tracers at different times. The heart of the LIDAR system is a Neodymium-doped Yttrium-aluminum-garnet (Nd:YAG) laser operating at a fundamental wavelength of 1064 nm, with harmonics of 532 nm and 355 nm. For these experiments the third harmonic was used because the UV wavelength at 355 nm is eye safe beyond about 50 m. The laser fires a pulse of light 6 ns in duration (about 1.8 m long) and with an energy (at the third harmonic) of about 70 mJ. This pulse subsequently scattered and absorbed by both air molecules and particles in the atmosphere. A small fraction of the laser beam is scattered back to the LIDAR, collected by a telescope and detected by a photo-multiplier tube. The intensity of the signal as a function of time is a measure of the particle concentration as a function of distance along the line of the laser shot. The smoke plume was clearly identifiable in the scans both before and after fumigation in the thermal internal boundary layer (TIBL). Both power station plumes were detected. Over the 9 days of operation, 1,568 plumes scans (214 series) were performed. Essentially all of these will provide instantaneous plume heights and widths, and there are many periods of continuous operation over several hours when it should be possible to compile hourly average plume statistics as well. The results of four days LIDAR observations of the dispersion of smoke plume in the TIBL at a coastal site are presented for the case of stages A and C.

  • PDF

Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae

  • Choi, Jung-Yoo;Sim, Jae-Hyuk;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.3
    • /
    • pp.182-192
    • /
    • 2017
  • Purpose: Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically separate contact and distance osteogenesis, thus allowing contact osteogenesis to be measured in the absence of possible triggers from distance osteogenesis. Methods: Sandblasted and acid-etched (SLA) and modified SLA (modSLA) implants were used. Both types had been sandblasted with large grit and then etched with acid. The modSLA implants then underwent additional treatment to increase hydrophilicity. The implants were implanted into rabbit tibiae, and half were implanted within Ti tubes. The bone-to-implant contact (BIC) ratio was calculated for each implant. Immunohistochemical analyses of bone morphogenetic protein (BMP)-2 expression and new bone formation (Masson trichrome stain) were performed. Results: The implants outside of Ti tubes were associated with good bone formation along the implant surface. Implantation within a Ti tube significantly reduced the BIC ratio (P<0.001). Compared with the modSLA implants, the SLA implants were associated with significantly higher BIC ratios, regardless of the presence or absence of Ti tubes (P=0.043). In the absence of Ti tubes, the bone adjacent to the implant had areas of new bone formation that expressed BMP-2 at high levels. Conclusions: This study disproved the null hypothesis and suggested that contact osteogenesis is initiated by signals from the old bone that undergoes distance osteogenesis after drilling. This signal may be BMP-2.

Vibration Sensing and Impact Location Measurement Using Intensity-Based Optical Fiber Vibration Sensor (광강도형 광섬유 진동센서를 이용한 진동감지 및 충격위치 측정)

  • 양유창;황운봉;박현철;한경섭
    • Composites Research
    • /
    • v.13 no.5
    • /
    • pp.1-9
    • /
    • 2000
  • An intensity-based optical fiber vibration sensor is applied to monitor the structural vibration and detect impact locations on a plate. Optical fiber vibration sensor is constructed by placing two cleaved fiber end, one of which is cantilevered in a hollow glass tube. The movement of the cantilevered section lags behind the rest of the sensor in response to an applied vibration and the amount of light coupled between the two fibers is thereby modulated. For vibration sensing, optical fiber vibration sensor is mounted on the carbon fiber composite beam and its response is investigated to free and forced vibration. In impact location detection, four optical fiber vibration sensors whose location is predetermined are placed at chosen positions and the different arrival times of impact-generated vibration signal are recorded by an FFT analyzer. Impact location can be calculated from these time delays. Experimental results show that optical fiber vibration sensor signals coincide with gap sensor in vibration sensing. The precise location of impact can be detected on an acrylate plate.

  • PDF

Development of Photoacoustic System for Breast Cancer Detection (유방암 진단용 광음향 영상 시스템 개발)

  • Lee, Soonhyouk;Ji, Yun-Seo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.183-190
    • /
    • 2013
  • Recently, the photoacoustic imaging system has been widely and intensively developed, and has been shown the possibility of diagnosis for early stage cancer. In this study, we developed a photoacoustic tomography imaging system with a commercial ultra sound device and a linear array probe. A tube phantom and a chicken breast phantom was made for the possibility of a system as a breast cancer detection. A moving average filter and a band pass filter with 3~6 MHz bandwidth were developed for background noise elimination before delay-and-sum beamforming algorithm was used for image reconstruction. As a result, we showed that some signal processing procedure before beamforming was effective for the photoacoustic image reconstruction.

Development of a Surge Protective Device for Computer Network to International Standards (국제규격 대응 컴퓨터 네트워크용 서지방호장치 개발)

  • Park Dae-won;Song Jae-yong;Han Joo-sup;Kil Gyung-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.6
    • /
    • pp.1253-1259
    • /
    • 2005
  • This paper dealt with the development of surge protection devices (SPDs) that can protect high speed computer network devices from overvoltages caused by switching operations or lightning surges. The designed SPD is a form of hybrid circuit which is composed of a gas tube having large current diverting capability, high response bi-directional avalanche diodes, and fast recovery diodes to reduce insertion loss on high frequency domain. Surge protection and signal transmission characteristics of the fabricated SPD was tested according to the international standards, IEC 61000-4-5 and IEC 61643-21. From the test results, the SPD is satisfied with the international standards and the high cut-off frequency was 204 MHz. Also, the SPD showed a good performance without an insertion loss on a field test of 100 Mbps class Local Area Network.