• Title/Summary/Keyword: signal tube

Search Result 318, Processing Time 0.028 seconds

Piezo-activated guided wave propagation and interaction with damage in tubular structures

  • Lu, Ye;Ye, Lin;Wang, Dong;Zhou, Limin;Cheng, Li
    • Smart Structures and Systems
    • /
    • v.6 no.7
    • /
    • pp.835-849
    • /
    • 2010
  • This study investigated propagation characteristics of piezo-activated guided waves in an aluminium rectangular-section tube for the purpose of damage identification. Changes in propagating velocity and amplitude of the first wave packet in acquired signals were observed in the frequency range from 50 to 250 kHz. The difference in guided wave propagation between rectangular- and circular-section tubes was examined using finite element simulation, demonstrating a great challenge in interpretation of guided wave signals in rectangular-section tubes. An active sensor network, consisting of nine PZT elements bonded on different surfaces of the tube, was configured to collect the wave signals scattered from through-thickness holes of different diameters. It was found that guided waves were capable of propagating across the sharp tube curvatures while retaining sensitivity to damage, even that not located on the surfaces where actuators/sensors were attached. Signal correlation between the intact and damaged structures was evaluated with the assistance of a concept of digital damage fingerprints (DDFs). The probability of the presence of damage on the unfolded tube surface was thus obtained, by which means the position of damage was identified with good accuracy.

Determination of Flow Direction by Using an Acousto-Optic Effect (광음향 변조효과를 이용한 유체의 방향 결정)

  • 김규욱
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.34-36
    • /
    • 1990
  • The flow direction in a glass tube is measured by using a forward scatering dual beam laser Doppler velocimeter with an acousto-optic modulator. We can determine the flow direction by measuring the shifted Doppler frequency which is dependent on the order of modulation of the laser frequency shifting moves only the Doppler signal, enabling complete separation of the Pedestal and Doppler singal.

  • PDF

Application of Radiations for Random Noise (형광물질의 방사선을 응용한 Random Nois)

  • J. K. Lee
    • 전기의세계
    • /
    • v.13 no.3
    • /
    • pp.8-12
    • /
    • 1964
  • The study of the research for Random process have been recently increasing rapidly. There are many methods in generating of Random signal, however, mainly these are dependent upon utilizing of hot noise of resistance and noise of discharge tube. Consequently, it is not easy to obtain of Random Noise of stabilized low frequency. Therefore, I like to study over the result of principle and design in the method of obtaining the Random Noise with faint radiations of fluoresence materials.

  • PDF

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Frequency Stabilization of He-Ne laser using One Chip Micro-Processor (1칩 마이크로 프로세서를 이용한 He-Ne 레이저의 주파수 안정화)

  • 최현승;엄태봉;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.102-105
    • /
    • 2000
  • A simple digital control system has been developed for the frequency stabilization of an internal mirror He-Ne laser. The system is based on one chip microprocessor with embedded Basic interpreter. To stabilize the laser output frequency, the signal such as power difference or beat frequency between two modes is supplied and processed by a microprocessor, and control signal is fed to the heating coil would round the laser tube for adjusting the spacing of the laser cavity mirror. Newly developed frequency stabilization system is totally digitized. The system and the frequency stability performance are briefly described.

  • PDF

Numerical Analysis of ECT with Axisymmetric Crack (원통형결함에 대한 와전류탐상의 수치해석)

  • Lee, H.B.;Shin, Y.K.;Lim, S.K.;Jung, H.K.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.83-85
    • /
    • 1997
  • In this paper a numerical analysis method for eddy current testing (ECT) with axisymmetric crack is studied. The finite element method(FEM) is used for electromagnetic solution. In this paper the outer diameter crack of INCONEL 600 tube is modelled and the impedance signal is obtained using the differential probe. The characteristics of the crack depth variation in the signal are analyzed.

  • PDF

Study on Characteristics of Plasma in Hollow Cathode Discharge (Hollow Cathode Discharge에서 플라즈마 특성에 관한 연구)

  • Yoon, Man-Young;Shin, Jong-Soon
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.23 no.2
    • /
    • pp.93-101
    • /
    • 2005
  • The measured plasma temperature of Ar hollow cathode discharge for several metal cathodes are about $620\;{\sim}\;780K$ at discharge current of $7\;{\sim}\;10mA$. The optogalvanic signals were measured using hollow cathode discharge tube with argon as buffer gas at change of discharge currents. A change of ionization rate due to electron collision causes an increase or decrease of the electric conductivity. This change in electric conductivity generates the optogalvanic signal. We conclude that optogalvanic signal has close relation with the lowest metastable atoms density at low current.

  • PDF

Self-Interference Cancellation for Shared Band Transmission in Nonlinear Satellite Communication Channels

  • Jung, Sooyeob;Ryu, Joon Gyu;Oh, Deock-Gil;Yu, Heejung
    • ETRI Journal
    • /
    • v.39 no.6
    • /
    • pp.771-781
    • /
    • 2017
  • For efficient spectral utilization of satellite channels, a shared band transmission technique is introduced in this paper. A satellite transmits multiple received signals from a gateway and terminal in the common frequency band by superimposing the signals. To improve the power efficiency as well as the spectral efficiency, a travelling wave tube amplifier in the satellite should operate near the saturation level. This causes a nonlinear distortion of the superimposed transmit signal. Without mitigating this nonlinear effect, the self-interference cannot be properly cancelled and the desired signal cannot be demodulated. Therefore, an adaptive compensation scheme for nonlinearity is herein proposed with the proper operation scenario. It is shown through simulations that the proposed shared band transmission approach with nonlinear compensation and self-interference cancellation can achieve an acceptable system performance in nonlinear satellite channels.

Determination of Flow Direction by Using an Acousto-Optic Modulator (광음향 변조기를 이용한 유체의 방향결정)

  • 김규욱;최종운;원종욱
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.58-64
    • /
    • 1990
  • The flow direction in a glass tube is measured by using a forward scattering dual beam laser Doppler velo$.$ cimeter with an acousto-optic modulator. We can determine the flow direction by measuring the shifted Doppler frequency which is dependent on the order of modulation of the laser beam and the fluid flow direction. Also. an electronic amplification circuit which has a bandwidth of 0 . 300 MHz and a gain of 38 dB is designed and fabricated to amplify the high frequency signal.signal.

  • PDF

A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom (흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구)

  • Hwang, Hyeseong;Kim, Nuri;Jeong, Yoonji;Goo, Eunhoe;Kim, Kijeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF