• Title/Summary/Keyword: signal number estimation

Search Result 262, Processing Time 0.03 seconds

Estimation of Nugget Size in Resistance Spot Welding Processes Using Artificial Neural Networks (저항 점용접에서 인공신경회로망을 이용한 용융부 추정에 관한 연구)

  • 최용범;장희석;조형석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.2
    • /
    • pp.393-406
    • /
    • 1993
  • In resistance spot welding process, size of molten nuggest have been utilized to assess the integrity of the weld quality. However real-time monitoring of the nugget size is an extremely difficult problem. This paper describes the design of an artificial neural networks(ANN) estimator to predict the nugget size for on-line use of weld quality monitoring. The main task of the ANN estimator is to realize the mapping characteristics from the sampled dynamic resistance signal to the actual negget size through training. The structure of the ANN estimator including the number of hidden layers and nodes in a layer is determined by an estimation error analysis. A series of welding experiments are performed to assess the performance of the ANN estimator. The results are quite promissing in that real-time estimation of the invisible nugget size can be achieved by analyzing the dynamic resistance signal without any conventional destructive testing of welds.

A Decorrelation Technique for Direction-of-Arrival Estimation of Coherent Signals (Coherent 신호의 입사방향 추정을 위한 상관관계 제거 기법)

  • Park, Geun-Ho;Shin, Jong-Woo;Kim, Hyoung-Nam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.95-104
    • /
    • 2016
  • Subspace-based direction-of-arrival (DOA) estimation algorithms have a difficulty in dealing with coherent signals caused by multi-path environment. As one of attempts to solve this problem, a spatial differencing method is known to be useful for not only estimating DOAs of the coherent signals but also improving the number of resolvable wavefronts even more than the number of antenna elements. However, since the conventional spatial differencing method uses only the partial statistics of the observed data, this method suffers from the performance degradation in estimation accuracy caused by the residual correlation between the uncorrelated signals. To cope with this problem, in this paper, a generalized spatial differencing method is proposed. Unlike the conventional method, the proposed method utilizes the entire statistics of the received signals. Therefore, the additional performance enhancement in both estimation accuracy and the number of resolvable wavefronts can be achieved. The performance analyses with computer simulations show that the proposed method outperforms the conventional method in terms of the estimation accuracy and the number of resolvable wavefronts.

People Counting and Coordinate Estimation Using Multiple IR-UWB Radars (다수의 IR-UWB 레이다를 이용한 인원수 및 좌표 추정 연구)

  • Tae-Yun Kim;Se-Won Yoon;In-Oh Choi;Joo-Ho Jung;Sang-Hong Park
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.19 no.1
    • /
    • pp.39-46
    • /
    • 2024
  • In this paper, we propose an efficient method for estimating the number of people and their locations using multiple IR-UWB radar sensors. Using three IR-UWB radar sensors in the indoor space, the measured signal from the target is processed to remove the clutter using rejection methods. Then, to further remove the clutter and to determine the presence of the human, the time-frequency image representing the micro-Doppler is obtained and classified by a convolutional neural network. Finally, the system finds the number of human objects and estimates each position in a two-dimensional space. In experiments using the measured data, the system successfully estimated the location and number of individuals with a high accuracy ≈ 88.68 %.

Separation of Partial Discharge Signals and Noise (부분방전 신호와 잡음의 분리)

  • 이승환;유치형;정찬수;김재철;이상철;정양웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.21-30
    • /
    • 1999
  • The research for retecting of insulating deterioration in transforrrer has been studied from long ago and the analysis rrethod of combustible gas which is included in insulating oil has been used Recently the spreading effect of the accident is larger than before because of high voltage and large capacity, so on-line detecting system is needed and the study for the estimation of partial discharge signals location has begun. This thesis is the study for the sermating noise signal that is the greatest problem in ultrasonic signal measurement which is one of the method of estimation of partial discharge signals location. Because we can measure the number and location of signal, it is rossible to distinguish between the signal of partial discharge and the external noise. Therefore, we can devolop the credibility of detecting of insulating deterioration in transformer.former.

  • PDF

Determination of Research Octane Number using NIR Spectral Data and Ridge Regression

  • Jeong, Ho Il;Lee, Hye Seon;Jeon, Ji Hyeok
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.1
    • /
    • pp.37-42
    • /
    • 2001
  • Ridge regression is compared with multiple linear regression (MLR) for determination of Research Octane Number (RON) when the baseline and signal-to-noise ratio are varied. MLR analysis of near-infrared (NIR) spectroscopic data usually encounters a collinearity problem, which adversely affects long-term prediction performance. The collinearity problem can be eliminated or greatly improved by using ridge regression, which is a biased estimation method. To evaluate the robustness of each calibration, the calibration models developed by both calibration methods were used to predict RONs of gasoline spectra in which the baseline and signal-to-noise ratio were varied. The prediction results of a ridge calibration model showed more stable prediction performance as compared to that of MLR, especially when the spectral baselines were varied. . In conclusion, ridge regression is shown to be a viable method for calibration of RON with the NIR data when only a few wavelengths are available such as hand-carry device using a few diodes.

Channel estimation and detection with space-time transmission scheme in colocated multiple-input and multiple-output system

  • Pratibha Rani;Arti M.K.;Pradeep Kumar Dimri
    • ETRI Journal
    • /
    • v.45 no.6
    • /
    • pp.952-962
    • /
    • 2023
  • In this study, a space-time transmission scheme is proposed to tackle the limitations of channel estimation with orthogonal pilot information in colocated multiple-input multiple-output systems with several transmitting and receiving antennas. Channel information is obtained using orthogonal pilots. Channel estimation introduces pilot heads required to estimate a channel. This leads to bandwidth insufficiency. As a result, trade-offs exist between the number of pilots required to estimate a channel versus spectral efficiency. The detection of data symbols is performed using the maximum likelihood decoding method as it provides a consistent approach to parameter estimation problems. The moment-generating function of the instantaneous signal-to-noise ratio is used to drive an approximate expression of the symbol error rate for the proposed scheme. Furthermore, the order of diversity is less by one than the number of receiver antennas used in the proposed scheme. The effect of the length of a pilot sequence on the proposed scheme's performance is also investigated.

A Study on an Improved MVE for Estimating the Direction of Arrival of Multiple Sources (다중 신호원의 도래방향 추정을 위한 개선된 MVE에 관한 연구)

  • 정용민;신준호;김용득
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.687-690
    • /
    • 1999
  • Many high-resolution algorithms based on the eigen-decomposition analysis of observed covariance matrix, such as MVE, MUSIC, and EVM, have been proposed. However, the resolution of spectral estimates for these algorithms is severely degraded when Signal-to-Noise Ratio (SNR) is low and arrival angles of signal are close to each other. And EVM and MUSIC is powerful for the characteristic of SNR. But have the limitation that the number of signals presented is known. While MVE is bad the characteristic of SNR. In this study, we propose a modified MVE to enhance the resolution for Direction-Of-Arrival (DOA) estimation of underwater acoustic signal. This is to remove the limitation that existing algorithms should know the information for the number of signals. Because the algorithms founded on the eigen value estimate DOA with only the noise subspace, they have the high-resolution characteristic. And then, with the method reducing the effect of the signal subspace, we are to reduce the degradation because of complementary relationship between the signal subspace and the noise subspace. This paper, with using the simulation data, we have estimated the proposed algorithms, compared it with other high-resolution algorithms. The simulation results show that the modified MVE proposed is accurate and has a better resolution even though SNR is low, under the same condition.

  • PDF

An algorithm for real time blood flow estimation of LDF (LDF의 실시간 혈류추정을 위한 알고리즘)

  • Kim, Jong-Weon;Ko, Han-Woo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.78-79
    • /
    • 1998
  • This paper describes a real time algorithm for blood flow estimation of LDF(laser Doppler flowmeter). Many algorithms for blood flow estimation are using power spectral density of Doppler signal by blood flow. In these research, the fast Fourier transformation is used to estimate power spectral density. This is a block processing procedure rather than real time processing. The algorithm in this paper used parametric spectral estimation. This has real time capability by estimation of AR(autoregressive) parameters sample by sample, and has smoothing power spectrum. Also, the frequency resolution is not limited by number of samples used to estimate AR parameter. Another advantage of this algorithm is that AR model enhance SNR.

  • PDF

A Study on EMG Signal Processing Using Linear Prediction (선형예측을 이용한 EMG 신호처리에 관한 연구)

  • ;邊潤植;李建基
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.2
    • /
    • pp.280-291
    • /
    • 1987
  • In this paper, the linear autoregressive model of EMG signal for four basic arm functions was presented and parameters for each function were estimated. The signal identification was carried out using function discrimination algorithm. It was validated that EMG signal was a widesense stationary process and the linear autoregressive model of EMG signal was constructed through approximating it to Gaussian process. It was confined that Levinson-Durbin algoridthm is a more appropriate one than the recursive least square method for parameter estimation of the linear model. Optimal function discrimination was acquired when sampling frequency was 500Hz and two electrodes were attached to bicep and tricep muscle, respectively. Parameter values were independent of variance and the number of minimum data for function discrimination was 200. Bayesian discrimination method turned out to be a better one than parallel filtering method for functional discrimination recognition.

  • PDF

Signal Measurement Algorithm for 3GPP WCDMA Measurement Equipment (3GPP WCDMA모뎀 계측장비를 위한 신호계측 알고리듬)

  • Hong, Dae-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.1
    • /
    • pp.7-15
    • /
    • 2011
  • In this paper, we implement measurement functionality for the 3GPP (Third Generation Partnership Project) WCDMA (Wideband Code Division Multiple Access) modem. Generally speaking, the receiving algorithms in normal modems cannot be used directly to the measurement system due to the lack of the measurement accuracy. In this paper, we propose the new measurement algorithm for precise 3GPP WCDMA signal measurements. In the measurement algorithm, 4-stage parameters estimation scheme is used. To improve the measurement accuracy, we increase the number of the received signal samples by interpolation. The proposed 3GPP WCDMA signal measurement algorithm can be used for verifying and implementing SoC/FPGA modem measurement systems.