• Title/Summary/Keyword: signal detector

Search Result 1,005, Processing Time 0.032 seconds

Analysis of Toxic Heavy Meatals using Hybrid Neural Network in Glow Discharge Atomic Emission Spectroscoy (글로우 방전 원자방출에서의 Hybrid Neural Network를 이용한 유해 중금속 분석)

  • Lee, J.S.;Lee, S.C.;Choi, K.S.;Kim, Y.S.;So, S.H.;Ha, K.J.;Ryu, D.H.;Cho, T.H.;Jung, M.S.
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.399-409
    • /
    • 2002
  • A system software on-line spectral analysis of atomic emission spectrometer. The system program consisted of a control part for the optical instruments and the spectrum analysis part the artificial intelligence method to reduce nonlinear error of the wavelengths. McPHERSON 207 Monochromator controlled GPIB communication protocol, and the detector signal was measured from PMT by using A/D Amplifier that was made by Photon_Tek. co.. HNN(Hybrid Neural Network) of artificial intelligence technique was applied to the qualitative analysis of P, Cu, Fe, Cr, and that was accurately applied to the quantitative analysis of Cd with 10 ppb level better than the conventional methods.

Classification of Normal and Abnormal QRS-complex for Home Health Management System (재택건강관리 시스템을 위한 정상 및 비정상 심전도의 분류)

  • 최안식;우응제;박승훈;윤영로
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.129-135
    • /
    • 2004
  • In the home health management system, we often face the situation to handle biological signals that are frequently measured from normal subjects. In such a case, it is necessary to decide whether the signal at a certain moment is normal or abnormal. Since ECC is one of the most frequently measured biological signals, we describe algorithms that detect QRS-complex and decide whether it is normal or abnormal. The developed QRS detection algorithm is a simplified version of the conventional algorithm providing enough performance for the proposed application. The developed classification algorithm that detects abnormal from mostly normal beats is based on QRS width, R-R interval and QRS shape parameter using Karhunen-Loeve transformation. The simplified QRS detector correctly detected about 99% of all beats in the MTT/BIH ECG database. The classification algorithm correctly classified about 96% of beats as normal or abnormal. The QRS detection and classification algorithm described in this paper could be used in home health management system.

A Design of Solar Proton Telescope for Next Generation Small Satellite

  • Sohn, Jongdae;Oh, Suyeon;Yi, Yu;Min, Kyoung-Wook;Lee, Dae-Young;Seon, Jongho
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.4
    • /
    • pp.343-349
    • /
    • 2012
  • The solar proton telescope (SPT) is considered as one of the scientific instruments to be installed in instruments for the study of space storm (ISSS) which is determined for next generation small satellite-1 (NEXTSat-1). The SPT is the instrument that acquires the information on energetic particles, especially the energy and flux of proton, according to the solar activity in the space radiation environment. We performed the simulation to determine the specification of the SPT using geometry and tracking 4 (GEANT4). The simulation was performed in the range of 0.6-1,000 MeV considering that the proton, which is to be detected, corresponds to the high energy region according to the solar activity in the space radiation environment. By using aluminum as a blocking material and adjusting the energy detection range, we determined total 7 channels (0.6~5, 5~10, 10~20, 20~35, 35~52, 52~72, and >72 MeV) for the energy range of SPT. In the SPT, the proton energy was distinguished using linear energy transfer to compare with or discriminate from relativistic electron for the channels P1-P3 which are the range of less than 20 MeV, and above those channels, the energy was determined on the basis of whether silicon semiconductor detector (SSD) signal can pass or not. To determine the optimal channel, we performed the conceptual design of payload which uses the SSD. The designed SPT will improve the understanding on the capture and decline of solar energetic particles at the radiation belt by measuring the energetic proton.

Implementation of Filter for the Removal of Partial Volume Effect (부분용적효과 제거를 위한 Filter 구현)

  • Park, Minju;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.139-145
    • /
    • 2015
  • When examining a patient using SPECT, gamma rays emitted from the body decrease or scatter. And when they reach the detector they spread in accordance with physical characteristics and geometric shapes of the scanner, quantitative analysis was difficult. For exact quantitative analysis of gamma rays emitted from the body, so that they must be considered to correction about PVE(partial volume effect). In this paper, sinogram filter was implemented to solve comprehensive PVE of SPECT. According to the results in which implemented filter was applied, partial volume effect caused by SPECT was removed. To compare proposed method and conventional method, PSNR(Peak Signal to Noise Ratio) was executed. As a result, proposed method was indicated as 7dB, conventional method was indicated as 14db respectively. dB(decibel) level of the proposed methods is lower, since the MSE(mean square error) becomes greater because scattered ray was removed, PSNR value is low. Therefore, by applying the proposed method for removing the PVE of SPECT imaging method, the image quality is improved.

Influence of Ne-Xe Gas Mixture Ratio on the Extreme Ultraviolet (EUV) Emission Measurement from the Coaxially Focused Plasma

  • Lee, Sung-Hee;Hong, Young-June;Choi, Duk-In;Uhm, Han-Sup;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.220-220
    • /
    • 2011
  • The Ne-Xe plasmas in dense plasma-focus device with coaxial electrodes were generated for extreme ultraviolet (EUV) lithography. The influence of gas mixture ratio, Ne-Xe (1, 10, 15, 20, 25, 30, 50%) mixture gas, on EUV emission measurement, EUV intensity and electron temperature in the coaxially focused plasma were investigated. An input voltage of 4.5 kV was applied to the capacitor bank of 1.53mF and the diode chamber was filled with Ne-Xe mixture gas at a prescribed pressure. The inner surface of the cylindrical cathode was lined by an acetal insulator. The anode was made of tin metal. The EUV emission signal of the wavelength in the range of 6~16 nm has been detected by a photo-detector (AXUV-100 Zr/C, IRD). The visible emission line was also detected by the composite-grating spectrometer of the working wavelength range of 200~1100 nm (HR 4000CG). The electron temperature is obtained by the optical emission spectroscopy (OES) and measured by the Boltzmann plot with the assumption of local thermodynamic equilibrium (LTE).

  • PDF

Reliable Multicast MAC Protocol with Low Probability of Detection for Survivability in Tactical Ad-hoc Networks (생존성 향상을 위해 신뢰성 및 저피탐을 보장하는 멀티캐스팅 MAC 프로토콜 기법)

  • Kim, Jeong-Hun;Jung, Jun-Woo;Kim, Jung-Bin;Lim, Jae-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11B
    • /
    • pp.1685-1695
    • /
    • 2010
  • In this paper, we propose a new reliable multicast MAC protocol over the IEEE 802.11-based tactical ad hoc networks. The major contribution compared to the previous reliable multicast schemes using consecutive CTSs/ACKs is that the proposed scheme can send multiple CTS/ACK messages concurrently assisted by MC-DS/CDMA mechanisms. When multiple receivers receive the RTS/DATA message from a sender, they respond with the CTS/ACK message spread with pre-assigned code in the same time interval. The proposed scheme can reduce the overhead of multiple CTSs/ACKs. It is also possible to alleviate the received signal strength at the enemy detector and thus it improves low probability of detection performance. Through simulations and analysis, the proposed scheme outperforms that of the multiple CTSs/ACks in terms of the throughput, transmission delay and low probability of detection.

The Response Characteristics of as Addition Ratio of Arsenic in $CaWO_4/a-Se$ based X-ray Conversion Sensor ($CaWO_4/a-Se$ 구조의 X선 변환센서에서 a-Se의 Arsenic 첨가량에 따른 반응 특성)

  • Kang, Sang-Sik;Suk, Dae-Woo;Cho, Sung-Ho;Kim, Jae-Hyung;Nam, Namg-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.416-419
    • /
    • 2002
  • There are being two prominent studying for Digital Radiography. Direct and Indirect method of Digital Radiography are announced for producing high quality digital image. The one is using amorphous selenium as photoconductor and the other is using phosphor layer as a light conversion. But each two systems have strength and weakness such as high voltage and blurring effect. In this study, we investigated the electrical characteristic of $multi-layer\left(CaWO_{4}+a-Se \right)$ as a photoconductor according to the changing arsenic composition ratio. This is a basic research for developing of Hybrid digital radiography which is a new type X-ray detector. The arsenic composition ratio of a-Se compound is classified into 7 different kinds which have 0.1%, 0.3%, 0.5%, 1%, 1.5%, 5%, 10% and were made test sample throught thermo-evaporation. The phosphor layer of $CaWO_4$ was overlapped on a-Se using EFIRON optical adhesives. We measured the dark and photo current about the test sample and compared the electrical characteristic of the net charge and signal-to-noise ratio. Among other things, test sample of compound material of 0.3% arsenic showed good characteristic of $2.45nA/cm^2$ dark current and $357.19pC/cm^2/mR$ net charge at $3V/{\mu}m$.

  • PDF

Study on the Development of Linearity of Broad-Band SDLVA Using Clamping Op-Amp (Clamping Op-Amp를 이용한 광대역 로그 비디오 증폭기의 선형성 개선에 관한 연구)

  • Park, Jong-Sul;Kim, Jong-Geon;Kim, Jum-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.6
    • /
    • pp.641-647
    • /
    • 2011
  • This paper describes a design and fabrication of SDLVA. The SDLVA operates 0.5~2.0 GHz with -70~0 dBm dynamic range. The SDLVA is consisted of 5-stage RF block, 2-stage detector block and summation circuit using clamping op-amp to improve video linearity. The result of measure, SDLVA of RF path has over 73 dB small-signal gain and 10.1~12.2 dBm saturation power. The video path has 25 mV/ dB${\pm}$1.0 mV and under ${\pm}$1.5 dB video linearity.

Star Detectability Analysis of Daytime Star Sensor (주간 활용 별센서의 별 감지가능성 분석)

  • Nah, Ja-Kyoung;Yi, Yu;Kim, Yong-Ha
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.9
    • /
    • pp.89-96
    • /
    • 2005
  • This paper discusses the daytime atmospheric conditions and the possibility of daytime star detection with the purpose of practical use of the star sensor for daylight navigation. In order to estimate the daytime atmospheric data, we use the standard atmospheric model (LOWTRAN 7), from which atmospheric transmittance and radiance from background sky are calculated. Assuming the star sensor with an optical filter to reduce background radiation, different separation angles between the star sensor and the sun are set up to express the effect of the solar radiation. As considerations of field of view (FOV) of the star sensor, the variation of the sky background radiation and the star density of the detectable star are analyzed. In addition, the integration time to achieve a required signal-to-noise ratio and the number of the radiation-caused electrons of the charge coupled detector(CCD) working as the limit to daylight application of the star sensor are calculated.

Earthquake-related Data Selection using Event Packets (이벤트 패킷을 이용한 지진관련 데이터의 추출)

  • Lim, In-Seub;Jung, Soon-Key
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.6
    • /
    • pp.59-68
    • /
    • 2008
  • In this paper, we propose a method for selecting meaningful event packets from which can receive before anything else from seismograph according to allotted priority and estimate epicenter using selected packets. Event packets which received from each station will be evaluated with their onset time, signal period and SNR by statistical method and will be selected packets related with real earthquake's P-wave. And estimated epicenters using by 'Application of epicenter estimation using first P arrivals'. With local earthquakes occurred in 2007 were announced by KMA, collected event packets on earthquake happened date and selected p-wave related packets and estimated epicenter. After result of experiment, if an earthquake occurred within seismic networks, can estimate epicenter with small misfits just after event packets arrived from above 4 stations. Considering average distance of each station, in case of using all stations' data include other organization, can estimate and alert rapidly. It show this method is useful when construct a local earthquake early warning system later.

  • PDF