• 제목/요약/키워드: side-polished fiber

검색결과 63건 처리시간 0.042초

In-line Variable Attenuator Based on the Evanescent Wave Coupling Between a Side-polished Single-mode Fiber and an Index Matched Dielectric Plate

  • Kim, Kwang-Taek;Kim, Hyo-Kyeom
    • Journal of the Optical Society of Korea
    • /
    • 제8권1호
    • /
    • pp.17-20
    • /
    • 2004
  • An in-line variable attenuator has been proposed and demonstrated exploiting a side-polished single-mode (SM) fiber evanescently coupled with an index matched dielectric plate. The attenuation can be controlled by fine mechanical sliding of the index matched dielectric plate. We have achieved 49 ㏈ dynamic range and very low excess loss of 0.2 ㏈ at 1550 nm wavelength. The measured polarization dependent losses (PDL) were 0.1, 0.2, and 0.4 ㏈ at 10, 20, and 30 ㏈ attenuation, respectively. Wavelength sensitivity was measured to be -0.017/nm ㏈ at 20 ㏈ attenuation.

측면 연마된 광섬유를 이용한 마이켈슨 간섭계 센서 제작 (The Fabrications of Michelson Interferometer Sensor Using Side Polished Fiber)

  • 이상필;김준형;윤영갑;조승용;이현용;황보승
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.388-389
    • /
    • 2006
  • 굴절률 등을 측정하기 위한 광센서로 이용하기 위해 광섬유 형태의 마이켈슨 간섭계와 측면 연마된 광섬유를 결합한 구조를 제안하였고, 이를 제작 및 특성 평가하였다. 마이켈슨 간섭계 구성은 광 파워 분기비가 50:50인 광커플러와 센서부로 사용하기 위한 측면 연마한 광섬유를 이용하였다. 그리고 광섬유의 끝단에는 거울 역할을 하도록 은(Silver)을 증착하여 구성하였다. 광섬유 형태의 마이켈슨 간섭계 센서의 센서부 표면에 굴절률 용액을 이용하여 광학적 특성을 평가하였다.

  • PDF

측면 연마된 광섬유와 완전도체면 아래의 유전체 사이에서의 결합과 전파특성의 해석 (Light Coupling and Propagation Between a Fiber and a Dielectric Slab with a Conductor Cladding)

  • 권광희;윤기홍;김정훈;송재원;박의돈;손석우
    • 한국통신학회논문지
    • /
    • 제28권2A호
    • /
    • pp.70-79
    • /
    • 2003
  • 완전도체면 아래의 유전체와 측면 연마된 광섬유의 소산장 결합 및 전파특성에 대한 해석 연구 결과를 나타내었다. 두 구조에서의 전파특성과 소산장 결합 관계를 해석하기 위해 결합모드 방정식과 혼합 모드(compound-mode) 방정식을 이용하여 코아와 유전체의 굴절률 및 구조의 각 변수에 대한 특성을 나타내었다. 그리고 측면 연마된 광섬유와 완전도체면 아래의 유전체가 결합할 때 일어나는 광섬유에서의 감쇠현상을 비교하기 위하여 감쇠상수를 구하여 함께 비교하였다.

Double clad fiber probe for fluorescence spectroscopy

  • Wang, Ling;Lee, Byeong-Ha
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 하계학술발표회 논문집
    • /
    • pp.35-36
    • /
    • 2007
  • We report a probe using a single double clad fiber (DCF) for fluorescence spectroscopy. Bidirectional separate transmission for excitation and fluorescence light in a single fiber was implemented. A DCF coupler made by side-polished method could extract none but the collected fluorescence signals propagating in inner cladding mode, thereby diminishing the interference of silica background generated by the excitation in core mode. The experimental results show that the fluorescence spectra of biological tissues obtained using the DCF probes have much less silica background than using a standard multiple-mode fiber.

  • PDF

표면 플라즈몬 광섬유 편광기 설계 및 제작 (Design and fabrication of the surface plasmon fiber polarizer)

  • 이준옥;김철호;김광택;권광희;송재원
    • 한국광학회지
    • /
    • 제14권2호
    • /
    • pp.169-174
    • /
    • 2003
  • 본 논문은 금속박막과 결합된 측면 연마 단일 모드 광섬유를 이용한 편광기에 관하여 이론 및 실험 연구 결과를 보고한다. 금속 박막의 두께와 상부 유전체의 굴절률이 소자특성에 미치는 영향을 직교 모드이론으로 분석하였다. 이론적 예측을 토대로 광통신파장에서 편광 소멸비가 40 ㏈, 그리고 삽입 손실이 0.5 ㏈를 가지는 편광기를 구현하였다.

전방과 측면 방사 조절이 가능한 의료용 광섬유 팁 가공 기술 (Laser Microfabrication of Multidirectional Side-fire Optical Fiber Tip)

  • 정덕;손익부;노영철;김진혁;김창환;이호
    • 한국정밀공학회지
    • /
    • 제30권10호
    • /
    • pp.1017-1022
    • /
    • 2013
  • Currently, various optical fiber tips are used to deliver laser beam for endoscopic surgery. In this paper, we demonstrated multidirectional (forward and side) firing optical fiber tip using a femtosecond micromachining and $CO_2$ laser polishing technology. We controlled the edge width of optical fiber tip, by modulating the condition of $CO_2$ laser, to regulate the amount of side and forward emission. The distal end of the optical fiber with core/clad diameter of $400/440{\mu}m$ was microstructured with cone shape by using a femtosecond laser. And then the microstructured optical fiber tip was polished by $CO_2$ laser beam result in smoothing and specular reflection at the surface of the cone structure. Finally, we operated the LightTools simulation and good agreement was generally found between the proposed model and experimental simulation.