• Title/Summary/Keyword: side view images

Search Result 61, Processing Time 0.025 seconds

Prevalence and extension of the anterior loop of the mental nerve in different populations and CBCT imaging settings: A systematic review and meta-analysis

  • Hadilou, Mahdi;Gholami, Leila;Ghojazadeh, Morteza;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.141-153
    • /
    • 2022
  • Purpose: This study aimed to identify the prevalence and extension of the anterior loop (AL) of the mental nerve in different populations and according to different cone-beam computed tomography (CBCT) imaging settings. Materials and Methods: Medline/PubMed, Embase, Scopus, Web of Science, and ProQuest were searched. The main inclusion criterion was ALs evaluated in CBCT images. The quality of studies was assessed with the Joanna Briggs Institute risk of bias checklist. Subgroup analyses were conducted for sex, side, continent, voxel size, field of view, and type of CBCT-reconstruction images with a random-effects model. Results: Sixty-three studies with 13,743 participants (27,075 hemimandibles) were included. An AL was found in 40.6% (95% CI: 32.8%-48.9%, P<0.05) of participants and 36.0% (95% CI: 27.5%-45.5%, P<0.05) of hemimandibles, in 34.9% (95% CI: 25.1%-46.2%, P<0.05) of males and 34.5% (95% CI: 23.5%-47.4%, P<0.05) of females. The average length of ALs was 2.39 mm (95% CI: 2.07-2.70 mm, P<0.05). Their extension was 2.13 mm (95% CI: 1.54-2.73 mm, P<0.05) in males and 1.85 mm (95% CI: 1.35-2.36 mm, P<0.05) in females. Significant differences were observed regarding the prevalence and length of ALs among continents and for its measured length on different CBCT-reconstruction images, but not between other subgroups. Conclusion: AL was a relatively common finding. The voxel size and fields of view of CBCT devices were adequate for assessing AL; however, a 2-mm safety margin from anatomical structures(such as the AL) could be recommended to be considered when using CBCT imaging.

A Study on the correlation between a streetscape image and a signboard density - Focused on roadside buildings occupation density of signboard in the business area - (가로경관이미지와 간판밀도와의 상관관계에 관한 연구 - 상업지역 연도건물의 간판 점유밀도를 중심으로 -)

  • Kim, Yun-Hee;Rhee, Jae-Won
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.287-296
    • /
    • 2005
  • The street image in a business area is so much affected by Facade that the front side of a roadside building makes. Recently, for the indiscreet and intemperate advertising signboard of the front side of roadside buildings, a streetscape becomes more disordered than before, so now we need to do research about signboards of roadside buildings for a streetscape image. In this research, we focused on a streetscape with difference of occupation density of signboard in the business area via investigation and analysis about occupation density of signboards of the front side of roadside buildings, and we suggested optimum occupation density of signboards for supporting the road image positively. An object of research is the street in the business area that has many pedestrians and active passing zone of cars. We investigated and analyzed how to feel street images on the rate of occupation density of roadside building's signboards of in the chosen street. As a result of using an adjective that we use for estimating street view images for extraction of street images, we could know 2 factors. We named that one is the image of recognition, and the other is the image of feelings. We knew that signboard density of street of heavily recognized images is from 20% to 30% and, signboard density of street of heavily feeling images is from 50% to 60%. We also could know that people feel both images of recognition and images of feeling in specific density, 30 to 50%. Through this result of research, we can suggest Facade on signboard density with the recognition and the feeling and use images of the street view as materials to be more specific and more special.

  • PDF

The Measurement of Three-Dimensional Temporal Behavior According to the Pressure in the Plasma Display Panel (플라즈마 디스플레이 패널에서 압력에 3차원 시간 분해 측정)

  • 최훈영;이석현;이승걸
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.476-480
    • /
    • 2003
  • In this paper, we have performed 3-dimensional time-resolving measurement of the Ne light emitted from the cell of plasma display panel(PDP) as a function of the pressure using the scanned point detecting system. From the temporal behavior results, we could analyze the discharge behavior of panel with Ne-Xe(4%) mixing gas and 300 torr, 400 torr and 500 torr pressure. At the top view of panel, the discharge of 300 torr panel starts at the 634 ns and ends at the 722 ns. The emission duration time is about 90 ns. The discharge of 400 torr panel starts at the 682 ns and ends at the 786 ns. the emission duration time is about 100 ns. Also, the discharge of 500 torr panel starts at the 770 ns and ends at the 826 ns. the emission duration time is about 56 ns. The discharge moves from inner edge of cathode electrode to outer cathode electrode forming arc type. In the side view of 300 torr, 400 torr and 500 torr an emission shows that the light is detected up to 180${\mu}{\textrm}{m}$, 150${\mu}{\textrm}{m}$ and 70${\mu}{\textrm}{m}$ height of barrier rib and the emission distribution of the 300 torr is wider than 400 torr, 500 torr.

Assessment of accessory mandibular canal in mandibular third molars using cone-beam computed tomography (콘빔 CT를 이용한 하악 제3대구치부의 부하악관 평가)

  • Cho, Bong-Hae;Jung, Yun-Hoa
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.753-761
    • /
    • 2014
  • Purpose: This study was performed to examine distribution of accessory mandibular canal and its characteristics in mandibular third molars. Materials and methods: A total of 251 subjects (166 males and 85 females) having mandibular third molars bilaterally were included in the study. Cone-beam computed tomographic images were reviewed for bifid or trifid accessory mandibular canal. The prevalence of accessory mandibular canal was evaluated according to gender, side and its branching type. Proximity and crosssectional position of accessory mandibular canal to mandibular third molar was analyzed. Results: Accessory mandibular canals were found in 66 (26.3%) of 251 patients and 86 (17.1%) of 502 hemi-mandibles. Gender and sides showed no statistically significant differences in prevalence. Retromolar canal (46.1%) was the most common branching type. Proximity of accessory canal to mandibular third molars showed mean distance of 2.8 mm from third molar and a statistically significant difference was found among types of accessory canal. Dental canal was the closest to tooth among branching types and closer to tooth than main canal. On cross-sectional view, accessory canal was generally located on buccal side of mandibular third molar. Conclusion: Accessory mandibular canal was common and well detected with cone-beam computed tomography. Their localization is significant in all anesthetic and surgical procedures involving mandibular third molars.

Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

The Analysis of Body-Image on the On-Line Game Lineage II Character Fashion (온라인 게임 리니지II 캐릭터 패션에 나타난 바디 이미지 분석(分析))

  • Jin, Kyung-Ok;Seo, Jung-Lip
    • Journal of Fashion Business
    • /
    • v.8 no.5
    • /
    • pp.144-154
    • /
    • 2004
  • The purpose of this study is to consider the characteristics of character's body-image throughout the on-line games and with this study we researched the symbolic meaning reflected by the character's body-images throughout the fashion. The characteristics of the body-images presented in modern fashion is expressed in 4 features on Lineage II game. First, it adopts the ways in which modern fashion expresses the erotic image and represents various sexual stimulation, which can not be represented in the real world, in cyberspace. Second, it expresses the beauty and taste in sensitivity by exchanging the items, which are the features of body-image, each other as the neutral body-image and pursuits for the double side feature between males and females by dismantling the point of view to sex. Third, it shows the new value system different from the existing one by using extraordinary items and materials that you've never seen in real fashion as the abnormal body-image expressed in informal and inaccurate principal of deformation. Fourth, it show the body with the items which induces more interest and curiosity than the real world do as the humorous body-image accompanying with childish amusement and pleasure.

Historical Reality and Cultural Memory: The Image of Peter I in Russian Literature and Folklore (역사적 현실과 문화적 기억 : 기록 문학과 구술 문학에 나타난 표트르 대제의 형상)

  • Seo, Seon Jeong
    • Cross-Cultural Studies
    • /
    • v.29
    • /
    • pp.201-232
    • /
    • 2012
  • In the world history in the rein of totalitarianism cultural project of government had been activated, and consequently of it official culture had been organized. But at the same time on the other side of it people('narod'), who didn't have cultural means for active expression of own opinion on the reality, had expressed world-view and judgement informally in everyday language. In the literature of autocracy, subjected to censorship, had been expressed and fixed mythically idealized image of sovereign and his works. But in the folklore the image of ruler had been created by liberal fantasy of people. This article examined russian literature and folklore texts of 18 century, when russian people suffered from rapid and dramatic changes, caused by Peter I. Although russian literature of 18 century had gone over to the new literary regime, it still accepted political mechanism as dominant of age, and consequently in the literary texts of this century Peter I was represented as ideal person and great monarch. But various images in folklore texts show that people's opinion on ruler and his activities couldn't be controlled. In other worlds, diverse images of Peter I in folklore texts reflect clear and plain historical consciousness of people. This analysis reveals not only difference between mechanism of idealization of government and historical consciousness of people, but also meaning of cultural memory as indicator of historical reality.

Comparison of Radiography Findings and Magnetic Resonance Image Findings of Lumbar Spine Instability Patients (요추 불안정 환자에서 단순방사선 소견과 자기공명영상 소견의 비교)

  • Lee, In-Hee;Park, Hee-Joon;Jin, Jong-Sik;Lee, Jyung-Hyun;Kim, Yoon-Nyun
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.3
    • /
    • pp.41-46
    • /
    • 2007
  • Purpose: This study was to investigate how dose the radiography findings are to magnetic resonance (MR) image findings in the L5-S1 instability patients. The subjects of this study were comprised of eleven males and fifteen females, who had Lumbago and agreed with this research. Methods: Radiography and MR images of Lumbar spine were acquired respectively from subjects in conditions of maximum flexion and extension. The horizontal and angular displacements in lumabosacral spine radiography were used to assess the instability of lumbar spine. MR images were also used to evaluate the intervertebral disc abnormalities and change of bone marrow. Results: The results are as follows. 1. In the case of flexion transitional displacement proposed by Dupuis et al, the specificity and negative predictive value were good accuracy ($0.7{\sim}0.8$), and the negative predictive value was in average. In the case of extension displacement, the negative predictive value was about average ($0.6{\sim}0.7$), but the sensitivity, specificity and positive predictive value were below the poor (<0.6). On the other side, the specificity was about average but other things were below in the case of angular displacement. 2. In the case of flexion transitional displacement proposed by Dupuis et al., compared with the intervertebral disc abnormalities, the negative prediction value was excellent, the sensitivity good, and the specificity about average. In the case of extension, the negative prediction value was about average, but the other things were poor. On the other side the specificity and negative predictive value had good accuracy and the sensitivity and positive prediction value were below average in the case of angular displacement. Conclusion: The above results show that the radiography finding is sufficiently helpful to find the lumbar spine instability as an economic point of view.

  • PDF

Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT (Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교)

  • Lim, Hyun-Jin;Kim, Joong-Hyun;Kim, Jae-Il;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.70-75
    • /
    • 2012
  • Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

  • PDF

Real-Time Pipe Fault Detection System Using Computer Vision

  • Kim Hyoung-Seok;Lee Byung-Ryong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.1
    • /
    • pp.30-34
    • /
    • 2006
  • Recently, there has been an increasing demand for computer-vision-based inspection and/or measurement system as a part of factory automation equipment. In general, it is almost impossible to check the fault of all parts, coming from part-feeding system, with only manual inspection because of time limitation. Therefore, most of manual inspection is applied to specific samples, not all coming parts, and manual inspection neither guarantee consistent measuring accuracy nor decrease working time. Thus, in order to improve the measuring speed and accuracy of the inspection, a computer-aided measuring and analysis method is highly needed. In this paper, a computer-vision-based pipe inspection system is proposed, where the front and side-view profiles of three different kinds of pipes, coming from a forming line, are acquired by computer vision. And the edge detection is processed by using Laplace operator. To reduce the vision processing time, modified Hough transform is used with clustering method for straight line detection. And the center points and diameters of inner and outer circle are found to determine eccentricity of the parts. Also, an inspection system has been built so that the data and images of faulted parts are stored as files and transferred to the server.