• Title/Summary/Keyword: side of angle

Search Result 1,329, Processing Time 0.034 seconds

Modeling and Analysis of Variable Wind Speed Turbine System Using Back to Back Converter (Back to bock 컨버터를 갖는 가변속 풍력터빈 시스템의 모델링과 해석)

  • Kim, Eel-Hwan;Kang, Keong-Bo;Kim, Jae-Hong;Moon, Sang-Ho;Oh, Sung-Bo;Kim, Se-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.150-157
    • /
    • 2005
  • This paper presents the simulation modeling and analysis of variable wind speed turbine system(VWTS) using the doubly fed induction generator(DFIG) connected the back to back converter system in the rotor side. In the simulation, using the model system which has the 660[kW] rated power, blade control and the dual converter system are modeled for verifying the control characteristics. The VWTS is controlled by the optimal pitch angle for maximum output power under the rated wind speed, and for the rated output power over the rated wind speed. And also power factor is controlled by the reactive power. To verify the effectiveness of the proposed method, simulation results are compared with the actual data from the V47 VWTS located in Hangwon wind farm in Jeju-Do. According to the comparison of these results, this method shows excellent performance.

Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

Development of a Web-based System for Raster Data Analysis Using Map Algebra (연구는 래스터 데이터의 지도대수 분석을 위한 GRASS 기반의 웹 시스템 개발)

  • Lee, In-Ji;Lee, Yang-Won;Suh, Yong-Cheol
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.4
    • /
    • pp.131-139
    • /
    • 2010
  • Recent spread of GIS and the increasing demand of spatial data have brought about the development of web GIS. In addition to sharing and mapping spatial data, web GIS is also required to provide spatial analytic functions on the web. The FOSS(free and open source software) can play an important role in developing such a system for web GIS. In this paper, we proposed a web-based system for raster data analysis using map algebra. We employed GRASS as an open source software and implemented the GRASS functionalities on the web using java methods for invocation of server-side commands. Map algebra and AHP were combined for the raster data analysis in our system. For a feasibility test, the landslide susceptibility in South Korea was calculated using rainfall, elevation, slope angle, slope aspect, and soil layers. It is anticipated that our system will be extensible to other web GIS for raster data analysis with GRASS.

Heat Transfer in Rotating Duct with $70^{\circ}$ Angled Ribs (회전하는 덕트내 설치된 $70^{\circ}$ 경사요철의 열전달 특성)

  • Choi, Chung;Lee, Sei Young;Won, Jung Ho;Cho, Hyung Hee;Park, Byung kyu
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.3 s.12
    • /
    • pp.7-13
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside a cooling passage of rotating gas-turbine blades. The rotating duct has staggered ribs with $70^{\circ}$ attack angle, which are attached on leading and trailing surfaces. Naphthalene sublimation technique is employed to determine detailed local heat transfer coefficients using the heat and mass transfer analogy. Additional numerical calculations are conducted to analyze the flow patterns in the cooling passage. The present experiments employ two-surface heating conditions in the rotating duct because the exposed surfaces to hot gas stream are pressure and suction side surfaces in the middle passages of an actual gas-turbine blade. Secondary flows are generated by Coriolis and centrifugal forces in the spanwise and streamwise directions. The ribs attached on the walls disturb the mainflow resulting in recirculation and secondary flows near the ribbed wall. The local heat transfer and flow patterns in the passage are changed significantly according to rib configurations and duct rotation speeds. Therefore, the geometry and arrangement of the ribs are important for the advantageous cooling performance. The experimental results show that the ribs enhance the heat transfer more than $70\%$ from that of the smooth duct. The duct rotation generates the heat transfer discrepancy between the leading and trailing walls due to the secondary flows induced by the Coriolis force. The overal heat transfer pattern on the leading and trailing walls for the first and second passes are depended on the rotating speed, but the local heat transfer trend is affected mainly by the rib arrangements.

  • PDF

Cross-sectional Survey for Prevalence Rate of Scoliosis in Primary, Middle and High School Boys in Pusan City (부산시내 남자 초.중.고등학생의 척추측만증 유병률 측정을 위한 단면조사)

  • Kim, Bok-Yong;Park, Jung-Han;Kim, Poong-Taek
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.217-223
    • /
    • 1988
  • A cross-sectional survey was conducted to determine the prevalence rate of scoliosis in elementary, middle and high school boys in May 1988. The study population included 1,393 male students in Pusan ; 463 students of 4th grade in two elementary schools, 543 students of 1st grade in one middle school and 387 students of 1st grade in one high school. The students of elementary school were screened with inspection by two physicians at the same time and the students of middle and high schools were screened with both inspection by the same physicians and 70mm chest X-ray. Positive students in any one of the two screening tests were measured for height and body weight and asked for the shoulder side on which he carries the school bag. The angle of curvature on X-ray film was measured by Cobb's method. The number of positive students in any one of the two screening tests were 15(3.2%) in elementary schools, 174(32.0%) in middle school and 92(23.8%) in high school. However, positive rates in both tests were only 2.2% for the middle school students and 2.6% for the high school students and among these students 1.1% out of total middle school students and 2.3% of high school students had a curvature equal to or greater than $5^{\circ}$ of Cobb's angle on 70mm chest X-ray film. There was a statistically significant association between the direction of spinal curve and the shoulder side on which one carries school bag among positive students in both screening 1.sts (p<0.05) Mean height and body weight of 281 positive students in any one of two screening tests were compared with the Korean standard for the same age. Mean weight of elementary school students was nearly the same as the standard weight but the height was slightly shorter than the standard. However, both mean height and weight of the middle school students were lower than the standard while those of the high school students were higher. The prevalence rate of scoliosis for the 2nd and 3rd grades of high school is presumed to be higher than that of the 1st grade of high school and the rate for girls will be even higher than the rate for boys of the same age. Thus, scoliosis seems to be an important school health problem. To prevent scoliosis, it is recommeded to reduce the weight of school bag, educate the students to keep a right posture and exercise periodically.

  • PDF

Characteristics of Beach Change and Sediment Transport by Field Survey in Sinji-Myeongsasimni Beach (신지명사십리 해수욕장에서 현장조사에 의한 해빈변화와 퇴적물이동 특성)

  • Jeong, Seung Myong;Park, Il Heum
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.594-604
    • /
    • 2021
  • To evaluate the causes of beach erosion in Sinji-Myeongsasimni Beach, external forces, such as tides, tidal currents, and waves, were observed seasonally from March 2019 to March 2020, and the surface sediments were analyzed for this period. In addition, the shoreline positions and beach elevations were regularly surveyed with a VRS GPS and fixed-wing drone. From these field data, the speed of the tidal currents was noted to be insufficient, but the waves were observed to af ect the deformation of the beach. As the beach is open to the southern direction, waves of heights over 1 m were received in the S-SE direction during the spring, summer, and fall seasons. Large waves with heights over 2 m were observed during typhoons in summer and fall. Because of the absence of typhoons for the previous two years from July 2018, the beach area over datum level (DL) as of July 2018 was greater by 30,138m2 compared with that of March 2019, and the beach area as of March 2020 decreased by 61,210m2 compared with that of March 2019 because of four typhoon attacks after July 2018. The beach volume as of March 2019 decreased by 5.4% compared with that of July 2018 owing to two typhoons, and the beach volume as of September 2019 decreased by 7.3% because of two typhoons during the observation year. However, the volume recovered slightly by about 3% during fall and winter, when there were no high waves. According to the sediment transport vectors by GSTA, the sediments were weakly influxed from small streams located at the center of the beach; the movement vectors were not noticeable at the west beach site, but the westward sediment transport under the water and seaward vectors from the foreshore beach were prominently observed at the east beach site. These patterns of westward sediment vectors could be explained by the angle between the annual mean incident wave direction and beach opening direction. This angle was inclined 24° counterclockwise with the west-east direction. Therefore, the westward wave-induced currents developed strongly during the large-wave seasons. Hence, the sand content is high in the west-side beach but the east-side beach has been eroded seriously, where the pebbles are exposed and sand dune has decreased because of the lack of sand sources except for the soiled dunes. Therefore, it is proposed that efforts for creating new sediment sources, such as beach nourishment and reducing wave heights via submerged breakwaters, be undertaken for the eastside of the beach.

A Study on Improving Survival of Bombina orientalis through Escape Facilities in Artificial Canals (무당개구리의 인공 수로 내 수로 탈출시설을 통한 생존성 향상에 대한 연구)

  • Jung-Hoon Bae;Young-Don Ju;Sul-Woong Shim;Yang-Seop Bae
    • Journal of Environmental Impact Assessment
    • /
    • v.33 no.1
    • /
    • pp.1-8
    • /
    • 2024
  • Amphibians are a taxonomic group that ecologically connects terrestrial ecosystems and aquatic ecosystems. They play a very important role in the food chain of the ecosystem. It is known that there are about 5,948 species distributed all over the world, but after the Industrial Revolution, due to industrialization and urbanization, there has been a decrease in species and populations. In particular, it is becoming a factor in exacerbating habitat fragmentation or fragmentation due to artificial canals. In orderto improve the survivalrate of wild animals in artificial canals, escape facilities are installed to reduce it. This study analyzed the slope, height of the escape facility, escape rate, and travel distance in the operating facility for Bombina orientalis, which mainly inhabits near forests. The slope of the escape facility showed a relatively similar escape success rate regardless of height at 50° and 60°, while at 70°, it showed a relatively high escape success rate at only 40cm in height. The success rate of escape from the waterway escape facility in operation was 14.71%, showing a very low utilization rate, and the recognition rate of the artificial canal escape facility was found to be very low as it moved along the side wall of the artificial canal. Therefore, in the case of a waterway escape facility for Bombina orientalis, it is possible to construct it at an angle of 60°, and if the side walls of the artificial canals are built within 60°, Bombina orientalis can move freely in both directions, overcoming the low utilization rate of existing waterway escape facilities. It is expected to minimize the impact of movement and death of artificial canals. In addition, if the spacing between escape facilities is narrowed from the installation standard of 30m and ramps are constructed in both directions upstream and downstream, the escape success rate of amphibians,reptiles, and small mammals otherthan lady frogs is expected to improve.

A Study on the Peripheral Dose of 6MV X-ray Beam (6 MV X선의 주변선량분포)

  • Choi, Doo-Ho;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.1
    • /
    • pp.24-33
    • /
    • 1989
  • The peripheral dose, defined as the dose outside therapeutic photon fields, was estimated for 6MV X-ray linear accelerator. The measurements were performed using silicon diode detectors controlled by automatic controlled water phantom. The effects of field size, collimator position, presence or absence of wedge filter, and wedge angle were analyzed. The results were as follows 1. The peripheral dose decreases as the distance from field margin increases and it is more than 2.4% of central axis maximum dose even at 15cm distance from field margin. 2. Maximum build-up of peripheral dose is at 2-3 mm from the water surface and drops to a minimum at 1.5cm depth and then the dose increase again. 3. The peripheral dose increases as the field size. increases. At the short distance from field margin, the difference of peripheral dose between 5 $\times\;5cm^2$ and 20 $\times\;20cm^2$ field size reaches more than 2 fold. 4. The peripheral dose is higher along the upper collimator than along the lower collimator. The differences is less than 1%. 5. The presence of wedge filter increases peripheral dose. And the peripheral dose is higher along the blade side of wedge filter than along the ridge side. The difference is about 3% at 5cm distance from the field margin for 15 $\times\;15cm^2$ field size and 60$^{\circ}$ wedge filter. 6. The Peripheral dose of wedge filter increases as the wedge filter angle increases and the increasing ratio is about 2 fold in 60$^{\circ}$wedge filter compared with open field.

  • PDF

수직형 LED의 광 추출효율 향상을 위한 표면 roughening에 대한 연구

  • Kim, Tae-Hyeong;Bae, Jeong-Un;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.323-324
    • /
    • 2011
  • 현재 많은 blue LED소자의 제작 공정과 소자 표면에 texturing하는 과정이 보고되어 있다. 그 중n층이 위로 올라오는 수직형 LED 구조로 인해 표면 texturing 기술은 빛의 발광 효율을 증가 시킬 수 있는 중요한 기술 중 하나가 되었다. 1 이 연구에서, 우리는 InGaN을 바탕으로 한 LED 소자의 표면 roughening을 건식과 습식 공정을 모두 거치는 과정을 통하여 소자의 발광 효율을 높이는 시도를 하였다. 최근 전도성 물질 기판 위에 증착 되어 있는 수직형 LED 소자 2,3,4는 과거의 사파이어 기판 위에 증착 되어 있는 형태의 LED 소자에 비해 우수한 소자 특성을 보인다. 이는 과거 사파이어 기판을 사용함으로써 낮은 열적 특성과 더불어 전기 정도성에 몇 가지 제약을 초래하게 되었기 때문이다. 반면, 전도성 기판은 LED 구조의 back side ohmic contact을 가능하게 하였고, 더 나은 확산 특성을 보여 주었고 작동 전압 또한 감소 하였다. N층이 위에 있는 수직형 LED 소자는 KrF pulsed excimer laser로 인해 실현 되었다. 이 laser 빛이 투명한 사파이어 기판을 통해 얇은 GaN층에 입사되면, 기판과 GaN가 분리된다. 이 레이저 기술은 laser lift-off(LLO)로 성장된 기판으로부터 LED 구조를 분리하는데 성공하게 하였다. 우리는 건식 식각 공정을 이용하여 n 층이 위에 올라와 있는 구조인 수직형 LED 소자에 roughening을 주고 다시 이 표면에 습식 식각 공정을 적용하여 거친 부분의 거칠기를 또 한번 증가시켰다. 그리고 이 거칠어진 표면은 이 공정이 진행 되기 전의 소자에 비해 빛의 발광 효율이 증가 되었다. 이 두 공정을 포함한 식각 공정은 두 가지 장점이 생겼는데, 한가지는 GaN에서 외부로 방출할 수 있는 표면 지역이 증가되었고, 다른 한가지는 가파른 거칠기 특성으로 인해 critical angle을 증가시킨 것이다.

  • PDF

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF