• Title/Summary/Keyword: side drop

Search Result 294, Processing Time 0.024 seconds

Characteristics of Fin-Side Heat-Transfer and Pressure Drop in a Condenser for Automobile (자동차용 응축기의 휜 열전달 및 압력강하 특성)

  • 곽경민;이홍열
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.152-158
    • /
    • 2004
  • An experimental study was performed to determine the fin-side heat transfer and pressure drop of a condenser for automobile. Five sample with different fin height and louver angle were tested, 9mm, 8mm, 7.5mm, 5.4mm and 4.5mm. Results are presented as plot of Colburn j-factor(or heat transfer coefficients) and friction factor(or pressure drop) against the Reynolds number(or inlet air velocity) based on louver pitch, in the range of 110 to 480. The results show that both heat transfer and pressure drop on the fin are mainly affected by the louver angle in a lower range of air velocity, but, by the fin height in a higher range of air velocity. The performance of 5.4mm fin is the highest, compared to other fin sample.

Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature (용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰)

  • Ham, Jeonggyun;Kim, Min-Jun;An, Sungkook;Cho, Honghyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

Air Side Heat Transfer Charactieristics of Tension Wound Transverse Fin with Minichannel (장력 감김으로 부착된 가로방향 휜-미니채널의 공기측 열전달 특성)

  • Kim Jong-Soo;Im Yong-Bin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.701-706
    • /
    • 2005
  • Pipes, tubes. and tubular sections with external transverse high fins have been used extensively for heating cooling, and degumidifying air and other gases. This work was performed to investigate an air side heat transfer charactieristics of minichannel with tension wound transverse fin. This estimate was confirmed conversion heat capacity the air side surface area enlargement and heat transfer charactieristics performed available inlet tube side hot water mass flux or outlet tube side air frontal air velocity. The most suitable tension wound transverse finned minichannel was measured extremely low in air side pressure drop and fin effectiveness $3.3\~4.4$. The pressure drop $0.9\~2.8Pa$ was ranged frontal air velocity $0.5\~1.2m/s$. It is also appeared that heat transfer in air side could be better conversion heat area which has been increased $330\%$ of heat capacity compared with the bare tube.

Vibration Characteristics and Drop Impacts of Bear Glass Bottles During Truck Transit (트럭 운송시 맥주용 유리병의 진동 및 낙하 특성)

  • Park, Su-Il;Park, In-Sik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.15 no.3
    • /
    • pp.77-81
    • /
    • 2009
  • There has been an increasing demand on measurement of the vibration levels in commercial truck shipments, where all packaged products are exposed to some levels of random vibration and shock. In this study, bear glass bottles loaded at the front, middle, and rear positions of 11 tonne truck bed was shipped from Kwangju to Waegouan. Vertical direction vibration levels were analysed and matching laboratory random vibration test was performed using power spectral density (PSD) profiles derived from truck transit records. Also, the effects of drop hight on glass bottles were evaluated. As expected, the maximum vibration levels were recorded at the rear of truck bed. No breakage of bottles were observed during truck transit and laboratory random vibration testing set at 0.52 $G_{rms}$. In drop test, glass bottles were not damaged by bottom side impact, while short side drop impact caused about twice higher bottle breakage rate than that of long side drop impact at 30 cm and 40 cm drop hight.

  • PDF

A study on the pressure drop characteristics of plate and shell heat exchangers (Plate and Shell 열교환기의 압력강하 특성에 관한 연구)

  • Seo, Moo-Kyo;Kim, Young-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.25-30
    • /
    • 2000
  • Plate and shell heat exchanger(P&SHE) has been applied to the refrigeration and air conditioning systems as evaporators or condensers fur their high efficiency and compactness. The purpose of this study is to analyze the characteristics of pressure drop in plate and shell heat exchanger. An experiment for single phase (low pressure drop in plate and shell heat exchanger was performed. Also numerical work was conducted using the FLUENT code for $ {\kappa}-{\varepsilon}$ model. The dependence of friction factor on geometrical Parameters was numerically investigated. The study examines the internal flow and the pressure distribution in the channel of plate and shell heat exchanger. The results of CFD analysis compared with experimental data, and the difference of frictor factor in plate side and shell side are 10% and 12%, respectively. Therefore, the CFD analysis model is effectively predict the performance of plate and shell heat exchanger.

  • PDF

Evaluation of Air-side Heat Transfer and Friction Characteristics on Design Conditions of Evaporator (증발기의 설계조건에서 공기측 열전달계수 및 압력강하 산출)

  • 김창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1007-1017
    • /
    • 2003
  • An experimental study on the air-side pressure drop and heat transfer coefficient of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper focuses on new method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface heat transfer estimation in fin-tube heat exchanger having refrigerant on the tube-side. Results are presented as plots of friction f-factor and Colburn j -factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of 150∼250 kg/$m^2$s with air flows at velocity ranges from 0.3 m/s to 0.8 m/s.

Evaluation of Air-side Heat Transfer and Friction Characteristics on Design Conditions of Condenser (응축기의 설계조건에서 공기측 열전달계수 및 압력강하 산출)

  • 김창덕;전창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.220-229
    • /
    • 2003
  • An experimental study on the air-side pressure drop and heat transfer coefficient of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper focuses on new method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry surface heat transfer estimation in fin-tube heat exchanger having refrigerant on the tube-side. Results are presented as plots of friction f-factor and Colburn j -factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of 150~250 kg/$m^2$s with air flows at velocity ranges from 0.6 m/s to 1.6 m/s.

A Study of Drop Handles Design

  • Cho, Sook-Kyung;Moon, Sun-Ok
    • Journal of the Korea Furniture Society
    • /
    • v.21 no.3
    • /
    • pp.253-260
    • /
    • 2010
  • The drop handle in the Chosun-Dynasty played a role lifting up the cabinet and box which was attached to and besides this had the decoration function. The scope of this study should include the drop handles from the $18^{th}$ century up to now by investigating and analyzing their definition & function and furthermore the types of their designs. The object of the study was the drop handle having 2 golden fixing parts which are definitive difference from ring or loop, and the design typology of drop handle was concentrated on the handle part, and it can be classified in two types. The one is the figuration of bow, bat, bamboo, fish and bird and so on from the motive of nature on the handle part, and the other one is the drop handle of the simple ㄷ-shape, the temple-symbol shape or geometrical forms. According to the analysis of relics & literature from the past it was found that there were more quantitative nature-motive figurations than the geometrical forms. The nature-motive figurations were again classified in box-, bat-, cloud- bamboo-, fish- and bird-type, and the geometrical forms in ㄷ-shape, the temple-symbol shape and others. The cases applied to furniture are roughly divided into the front-attached type and the side-attached type. In comparison of the drop handle in the Chosun-Dynasty with that of modern times, ㄷ-shape and bow-type keep the long tradition of the drop handles despite of the constructive change partly. Ring-type is similar to the just ring or loop of the part and drop handle with one golden fixing part, while the knob-type shows almost same forms in the past as well as in the modern times. Which type among handles in the modern times has little connection with the past is the reclaimed type, and it was showed in the Chosun-Dynasty and also is showed up to now identically that the man-made hole on the front side of the drawer for the function as handle.

  • PDF

The Heat Transfer and Pressure Drop Characteristics on Microchannel PCHE with various Configurations (채널 형상에 따른 마이크로채널 PCHE의 열전달 및 압력강하 특성)

  • Kim, Yoon-Ho;Moon, Jung-Eun;Lee, Kyu-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.215-220
    • /
    • 2008
  • A microchannel PCHE is manufactured by the two technologies of micro photo-etching and diffusion bonding. In this paper, heat transfer and pressure drop characteristics by applying various configuration for the flow channel in the microchannel PCHE is experimentally investigated. The flow channel configurations are designed three types such as straight, wavy and offset strip channels. The performance experiment of each configuration is performed for Reynolds numbers in ranges of $100{\sim}700$ under various flow conditions for the hot side and the Reynolds number of cold side is fixed at 350. The inlet temperatures of the hot side and cold side are conducted as $40^{\circ}C$ and $20^{\circ}C$, respectively. The heat transfer performance of wavy channel, which was similar to that of offset strip channel, was much higher than that of straight channel. The effectiveness of wavy channel and offset strip channel was evaluated as about $0.5{\sim}0.9$. The pressure drop of wavy channel was highest among configurations and that of offset strip channel was lower than that of straight channel because the round curved surface of each strip edge was reduced the pressure loss.

  • PDF

Add/drop Filter for CWDM Systems Using Side-coupled Long-period Fiber Gratings

  • Chan Florence Y. M.;Kim Myoung Jin;Lee Byeong Ha
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.135-139
    • /
    • 2005
  • We demonstrate a simple and effective wavelength-tunable add/drop filter suitable for coarse wavelength division multiplexing (CWDM) systems. The filter consists of two fibers in contact side by side, with identical long-period fiber gratings (LPG) in each fiber. The LPG couples the power in the fundamental core mode to one of the cladding modes, which is then coupled to the same order cladding mode in the other fiber through evanescent-field coupling between two fibers. Finally, the cladding mode in the second fiber is coupled to its core mode with the help of the other LPG. With an optimal longitudinal offset distance of 10 em, coupling efficiency as high as -1.68 dB and side lobes smaller than -24 dB were experimentally obtained. The experimental results agreed well with the theoretical ones. The operating wavelength of the proposed add/drop filter was tunable by varying the temperature. The temperature sensitivity was measured to be -0.43 nm/$^{\circ}C$.