• Title/Summary/Keyword: side channel

Search Result 926, Processing Time 0.021 seconds

Implementation of Optimized 1st-Order Masking AES Algorithm Against Side-Channel-Analysis (부채널 분석 대응을 위한 1차 마스킹 AES 알고리즘 최적화 구현)

  • Kim, Kyung Ho;Seo, Hwa Jeong
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.8 no.9
    • /
    • pp.225-230
    • /
    • 2019
  • Recently, with the development of Internet technology, various encryption algorithms have been adopted to protect the sensing data measured by hardware devices. The Advanced Encryption Standard (AES), the most widely used encryption algorithm in the world, is also used in many devices with strong security. However, it has been found that the AES algorithm is vulnerable to side channel analysis attacks such as Differential Power Analysis (DPA) and Correlation Power Analysis (CPA). In this paper, we present a software optimization implementation technique of the AES algorithm applying the most widely known masking technique among side channel analysis attack methods.

Flush+Reload Cache Side-Channel Attack on Block Cipher ARIA (블록 암호 ARIA에 대한 Flush+Reload 캐시 부채널 공격)

  • Bae, Daehyeon;Hwang, Jongbae;Ha, Jaecheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.6
    • /
    • pp.1207-1216
    • /
    • 2020
  • Since the server system in the cloud environments can simultaneously operate multiple OS and commonly share the memory space between users, an adversary can recover some secret information using cache side-channel attacks. In this paper, the Flush+Reload attack, a kind of cache side-channel attacks, is applied to the optimized precomputation table implementation of Korea block cipher standard ARIA. As an experimental result of attack on ARIA-128 implemented in Ubuntu environment, we show that the adversary can extract the 16 bytes last round key through Flush+Reload attack. Furthermore, the master key of ARIA can be revealed from last and first round key used in an encryption processing.

An Improved Side Channel Power Analysis with OP-Amp (OP-Amp를 적용한 향상된 부채널 전력분석 방법)

  • Kim, JinBae;Ji, JaeDeok;Cho, Jong-Won;Kim, MinKu;Han, Dong-Guk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.3
    • /
    • pp.509-517
    • /
    • 2015
  • Side Channel Analysis of applying the power-consumption was known as effective method to analyze the key of security device based on chip. The precedential information of power-consumption was measured by the voltage distribution method using by series connection of resistor. This method was dependent on the strength of the voltage. If the voltage cannot be acquired much information which is involved with the key, the information of power-consumption significantly might be influenced by noise. If so, some of the information of power-consumption might be lost and distorted. Then, this loss can reduce the performance of the analysis. For the first time, this paper will be introduced the better way of the improvement with using the method of Current to Voltage Converter with OP-Amp. The suggested method can reduce the effect of the noise which is included in the side channel information. Therefore we can verify the result of our experiments which is provided with the improvement of the performance of side channel analysis.

A Side Channel Attack with Vibration Signal on Card Terminal (진동 신호를 이용한 카드 단말기 부채널 공격)

  • Jang, Soohee;Ha, Youngmok;Yoon, Jiwon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.6
    • /
    • pp.1045-1053
    • /
    • 2014
  • In this paper, we assume that the information leakage through side-channel signal may occur from the card payment terminal and newly introduce a real application attack model. The attack model is a side channel attack based on vibration signals, which are detected by a small sensor attached on card terminal by attacker. This study is similar to some other studies regarding side channel attack. However, this paper is different in that it is based on the non-language model. Because the financial transaction information such as a card number, password, mobile phone number and etc cannot have a constant pattern. In addition, there was no study about card terminal. Therefore, this new study is meaningful. We collected vibration signals on card terminal with a small wireless sensor and analyzed signal data with statistical signal processing techniques using spectrum of frequency domain and principal component analysis and pattern recognition algorithms. Finally, we evaluated the performances by using real data from the sensor.

The Hydraulic Assessment of Side Weir using 3D Computational Fluid Dynamics Program (3차원 수치모형에 의한 횡월류위어의 수리학적 평가)

  • Nam, Ki-Young;Han, Kun-Yeun;Park, Hong-Sung;Kim, Keuk-Soo;Choi, Seung-Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.2
    • /
    • pp.153-168
    • /
    • 2010
  • The objectives of this study are to analyze flow characteristics for a side weir, which is an inlet structure for flow discharge reduction in the main channel through 3 dimensional numerical analysis and to understand the efficiency of the overflow effect at the side weir. In this study over 40 simulations using FLOW-3D, a computational fluid dynamics program were conducted, and the results were analyzed to find the influence of the flow hydraulics, geometry, channel and weir shapes on the coefficient. It is especially considered the relatively high stage in downstream that may cause flow within channel to be backed up along the channel. Additionally by setting up the scale of simulations much larger than the existing test equipment designed by other researchers, it is intended to analyze more accurate hydraulic behavior along with the realistic hydraulic features such as structures and volumes of flow. The results show that for design with subcritical flow only if the Froude number of upstream is sustained below 0.5 and the length of weir is 33-100% of the width of channel, it is expected to improve the efficiency of the overflow over a side weir.

Weight Recovery Attacks for DNN-Based MNIST Classifier Using Side Channel Analysis and Implementation of Countermeasures (부채널 분석을 이용한 DNN 기반 MNIST 분류기 가중치 복구 공격 및 대응책 구현)

  • Youngju Lee;Seungyeol Lee;Jeacheol Ha
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.6
    • /
    • pp.919-928
    • /
    • 2023
  • Deep learning technology is used in various fields such as self-driving cars, image creation, and virtual voice implementation, and deep learning accelerators have been developed for high-speed operation in hardware devices. However, several side channel attacks that recover secret information inside the accelerator using side-channel information generated when the deep learning accelerator operates have been recently researched. In this paper, we implemented a DNN(Deep Neural Network)-based MNIST digit classifier on a microprocessor and attempted a correlation power analysis attack to confirm that the weights of deep learning accelerator could be sufficiently recovered. In addition, to counter these power analysis attacks, we proposed a Node-CUT shuffling method that applies the principle of misalignment at the time of power measurement. It was confirmed through experiments that the proposed countermeasure can effectively defend against side-channel attacks, and that the additional calculation amount is reduced by more than 1/3 compared to using the Fisher-Yates shuffling method.

Investigation of Stresses Due to Various Parameters of Shell and Tube Oil Cooler (다관 원통식 오일 냉각기의 다양한 파라미터에 따른 스트레스 고찰)

  • Han, S.K.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.5-12
    • /
    • 2009
  • The present work aims to estimate channel, shell, tube and tube sheet stresses of shell and tube oil cooler stemmed from various parameters. These parameters involve size, thickness and dimension of shell and tube oil cooler, including fluid temperature. The main purpose of the present work is to ensure safety of design products and also develop new products rapidly. For stress evaluation of oil coolers, first of all, the maximum pressure on the shell-side and on the tube side is fixed with 3.1MPa and 1.5MPa, respectively. Secondly, the pressure on each side varies from 2MPa to 3.1MPa on the shell side and tram 0.6MPa to 2MPa on the tube side. Various parameters under these conditions are employed to estimate design stresses on each side of oil cooler. These basic information related to stresses will be useful for a designer or manufacturer of an oil cooler.

  • PDF

Design of Multiprocess Models for Parallel Protocol Implementation (병렬 프로토콜 구현을 위한 다중 프로세스 모델의 설계)

  • Choi, Sun-Wan;Chung, Kwang-Sue
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.10
    • /
    • pp.2544-2552
    • /
    • 1997
  • This paper presents three multiprocess models for parallel protocol implementation, that is, (1)channel communication model, (2)fork-join model, and (3)event polling model. For the specification of parallelism for each model, a parallel programming language, Par. C System, is used. to measure the performance of multiprocess models, we implemented the Internet Protocol Suite(IPS) Internet Protocol (IP) for each model by writing the parallel language on the Transputer. After decomposing the IP functions into two parts, that is, the sending side and the receiving side, the parallelism in both sides is exploited in the form of Multiple Instruction Single Data (MISD). Three models are evaluated and compared on the basis of various run-time overheads, such as an event sending via channels in the parallel channel communication model, process creating in the fork-join model and context switching in the event polling model, at the sending side and the receiving side. The event polling model has lower processing delays as about 77% and 9% in comparison with the channel communication model and the fork-join model at the sending side, respectively. At the receiving side, the fork-join model has lower processing delays as about 55% and 107% in comparison with the channel communication model and the event polling model, respectively.

  • PDF

Evaluation of Discharge Coefficients for Sharp Crested Side Weir in Wide Channel (폭이 넓은 개수로에서의 예연횡월류위어 유량계수 산정)

  • Lee, Dong Sop;Kim, Chang Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.449-458
    • /
    • 2008
  • This study is investigating experimentally the effect of upstream Froude number, weir height, weir length, and main channel width on the discharge coefficient of rectangular sharp crested side-weirs under subcritical flow conditions in a relatively wide rectangular open channel based on the De Marchi discharge coefficient $C_M$. The effects of four main influential parameters found by dimensional analysis, $Fr_1$, $h/y_1$, L/B, and $L/y_1$ are examined by the flume tests. New estimated equations for the discharge coefficients of sharp-crested side-weir are suggested based on the experimental results. The effect of $Fr_1$ for the discharge coefficient of sharp crested side weir is decreased in wide open channel and the relative importance of other influential parameters like $h/y_1$, L/B, and $L/y_1$ are increased. Also, the experimental results are compared with the results of other studies to extend the applicability of pre-suggested formulas for sharp-crested side-weir discharge coefficient.

Estimation of discharge coefficients of the broad-crested side weir with various levee's side slope of main channel (본류수로의 제방사면경사에 따른 광정횡월류위어의 유량계수 산정)

  • Kang, Ho-Seon;Cho, Hong-Je
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.11
    • /
    • pp.941-949
    • /
    • 2016
  • The flow characteristics of the broad-crested side weir considering the levee's side slope of main channel ($ES_{ch}$) was investigated through hydraulic experiment in order to estimate the discharge coefficient equation. For applicability to actual river, levee's side slope of main channel 1:0.5, 1:1 and 1:2 were selected. Experimental results show that the new estimated equation for the discharge coefficient including $ES_{ch}$ is reasonable and effective in actual applications by comparing estimated and measured discharge over side weirs. Through a multiple linear regression analysis the importance of variabes were ordered as $ES_{ch}$ > $h/y_u$ > $L/y_u$ > $Fr_u$. Especially the discharge coefficient equation without $Fr_u$ was suggested, and the high applicability was reviewed by comparing the measured and calculated overflow of broad-chested side weir.