• 제목/요약/키워드: show window

검색결과 733건 처리시간 0.028초

쇼윈도 조명환경에 관한 (A Study on the Illumination Environment in Show Window)

  • 김현지;안옥거
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.32-37
    • /
    • 1993
  • This study investigates the relationship between size, illumination ,and display of show window. The average width, heigh, and depth of show windows in Taegu area were 341.3, 233.4, and 125.8cm, respectively. As light source, halogen lamp was most frequently used, followed by fluorescent lamp and incandescence lamp. In the actual illumination, however, a combined use of more than 2 light sources was common. Further, a local illumination method, e.g., spot light, was generally adopted. The thought of employers and employees in fashion shops about display and illumination was examined aw well. On the whole, the necessity and importance of display were well recognized but the fact that the illumination should be hamonized with other factors such as color and arrangement of goods was underestimated.

  • PDF

OFDM 시스템의 PAPR 저감을 위한 가변적인 윈도우 크기를 적용한 Peak Windowing 기법 (A New Peak-Windowing Algorithm with Window-length Adaptation for PAPR Reduction of OFDM Systems)

  • 이성은;방극준;박명희;이영수;홍대식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.185-188
    • /
    • 2005
  • This paper proposes a new peak-windowing algorithm with window-length adaptation for peak-to-average power reduction (PAPR) of orthogonal frequency division multiplexing (OFDM) systems. Conventional peak windowing algorithm has advantages, such as moderate system complexity with good spectral shape. However, adjacent peak signals within the length of window functions produce the distortion of signal amplitude since window functions might overap with each other. These undesired characteristics of conventional peak windowing algorithm result in the degradation of BER performance. The proposed algorithm outperforms the conventional one with the aid of window-length adaptation. Simulation results show the efficiency of the proposed algorithm under the environments of WiBro downlink systems.

  • PDF

미임계로 표적빔창의 열수력 해석 (Thermal Hydraulic Power Analysis of the HYPER Target Beam Window)

  • 송민근;주은선;최진호;송태영;탁남일;박원석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.39-42
    • /
    • 2002
  • The nuclear transmutation technology to Incinerate the long lived radioactive nuclides and produce energy during the incineration process is believed to be one or the best solutions. HYPER(${\underline{HY}}brid {\underline{P}}ower {\underline{E}}xtraction {\underline{R}}$eactor)is the accelerator driven transmutation system which is being developed by KAERI(Korea Atomic Energy Research Institute). Lead-bismuth(Pb-Bi) is adopted as a coolant and spallation target material. In this paper, we performed the thermal-hydraulic analysis of HYPER target using the commercial code FLUENT, and also calculated thermal and mechanical stress of the beam window using the commercial code ANSYS. It is found that there is an optimum value for the window diameter and the maximum allowable beam current can be increased to 17.3 mA for the inner diameter of windows, 40 cm. Finally, the other shapes such as uniform or scanned beam were considered. The results of FLUENT calculations show that the uniform type is preferable to the other shapes of the beam in terms of the window and target cooling and the maximum window temperature is lower than that of the parabolic beam by $58 ^{\circ}C$ for the beam current, 13 mA.

  • PDF

허리 근육의 근전도 신호 안정성이 주파수 분석에 미치는 영향 (The Effect of the Signal Stationarity on the EMG Frequency Analysis)

  • 조영진;김정룡
    • 대한인간공학회지
    • /
    • 제29권2호
    • /
    • pp.183-188
    • /
    • 2010
  • The purpose of this study is to investigate the stationarity of the electromyographic signal in various flexion angles, loads, and window sizes, which influence the result of the mean power frequency (MPF) and median frequency (MNF) analysis. Six healthy subjects participated in the experiment. They were tested in the combination of 3-level flexion angles (0 degree, 22.5 degree, 45 degree) and 3-level loads (0Nm, 30Nm, 60Nm). Electromyographic data were collected for 20 seconds during isometric contraction. The stationarity of collected data were analyzed with four different window sizes including 250, 500, 1000 and 2000ms. Two test methods for stationarity such as Reverse Arrangements Test and Modified Reverse Arrangements Test were used. In order to show the effect of nonstationarity, the increasing/decreasing trend of MPF and MNF trend were discussed. In results, the stationarity of the electromyographic signal decreased as flexion angle increased and load decreased while window size decreased based on Reverse Arrangements Test. The highest stationarity was shown at 500 ms window in Modified Reverse Arrangements Test. The inclination of MNF and MPF indicated 3.6-6.3%, 3.8-5.1% discrepancy compared to the result from stationary data.

Trends in Indian Private Sector Bank Efficiency: Non-Stochastic Frontier DEA Window Analysis Approach

  • KUMAR, Ashish;ANAND, Nakul;BATRA, Vikas
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권10호
    • /
    • pp.729-740
    • /
    • 2020
  • The study examines the efficiency of private sector banks in India with the help of Window DEA (Data Envelopment Analysis) for a period from 2005 to 2017. With a window of three years, the period was divided into 11 windows. The study outcomes show that 59.9% of all private sector banks in India operate at more than 0.9 level of efficiency, and there are only three occasions when banks were operating at the efficiency value between 0.6 to 0.7. Further, the consistency in the efficiency scores of the banks has also been analyzed using an efficiency mapping matrix, and the mean efficiency score of the bank in each window is studied. The score of standard deviation was interpreted accordingly for these banks. Banks that are showing the highest efficiency scores also have a higher variance of efficiency scores. There was no bank identified in the matrix that promises high-efficiency ratings with low variability. The study concludes that the analysis of the efficiency mapping matrix indicates that, as a DMU escalates in the efficiency scores, the standard deviation reflecting the risk in overall efficiency scores also tends to rise. The findings complement the concept of higher risk to higher return or greater efficiency.

공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구 (A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments)

  • 윤종호;안영섭;김병수;황상근
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

DEA/Window를 이용한 국립대학도서관의 효율성 추세변화 분석 (Trends in the Efficiency of Korean National University Libraries : A DEA/Window Analysis Approach)

  • 한하늘
    • 정보관리연구
    • /
    • 제40권3호
    • /
    • pp.41-60
    • /
    • 2009
  • 최근까지 DEA를 이용한 대학도서관 효율성 평가에 관한 선행연구들은 대부분 특정 시점의 횡단면 분석 위주였으며, 효율성 추세변화 분석과 같은 종단면 분석은 거의 수행되지 못하고 있었다. 이에 본 연구에서는 우선 선행연구들처럼 DEA를 이용하여 특정 시점(2008년) 기준 하에서 국립대학도서관의 상대적 효율 수준을 분석하고, 다음으로 DEA Window 분석 기법을 적용하여 최근 5년(2004년-2008년)간 상대적 효율 수준의 추세변화를 분석하였다. 분석 결과 첫째, 특정시점 하에서 상대적 효율은 기술 효율성 측면에서 비효율적이었으며, 이는 상대적으로 규모의 비효율에 기인하는 것으로 나타나 선행연구 결과들을 재확인하였다. 둘째, 이러한 기술 효율성의 비효율은 전반적으로 최근 5년간 지속적인 개선이 있었으나 이는 상대적으로 순수 기술 효율성의 개선에 따른 것으로 나타났다. 따라서 앞으로 국립대학도서관의 기술 효율성을 개선하기 위해서는 규모의 비효율을 개선하는 노력이 필요할 것으로 사료된다.

높은 처리율을 갖는 고속 터보 복호 기법 (High Throughput Turbo Decoding Scheme)

  • 최재성;신준영;이정우
    • 대한전자공학회논문지TC
    • /
    • 제48권7호
    • /
    • pp.9-16
    • /
    • 2011
  • 본 논문에서는 높은 처리율을 가지는 다양한 터보 복호 방식을 소개하고 각각의 장점을 기반으로 한 새로운 고속 터보 복호 기법을 제안한다. 제안된 기법은 기본적으로 슬라이딩 윈도우, 복류 복호, 셔플 복호 방식을 사용하며 모의실험 결과, 제안된 기법은 기존의 방법에 비해서 적은 클록 사이클로도 동일한 BER 성능을 얻을 수 있음을 확인하였다. 게다가 슬라이딩 윈도우 크기를 적절하게 조정하면 메모리 사용량도 줄일 수 있음을 확인하였다. 따라서 본 논문에서 제안한 터보 복호 기법을 사용함으로써 저 전력, 저 면적의 고속 터보 복호기의 설계가 가능하다.

$ZrO_2$$CeO_2$ 절연체를 이용한 BLT/절연체/Si 구조의 특성 (Characterization of BLT/insulator/Si structure using $ZrO_2$ and $CeO_2$ insulator)

  • 이정미;김경태;김창일
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.186-189
    • /
    • 2003
  • The MFIS capacitors were fabricated using a metalorganic decomposition method. Thin layers of $ZrO_2$ and $CeO_2$ were deposited as a buffer layer on Si substrate and BLT thin films were used as a ferroelectric layer. The electrical and structural properties of the MFIS structure were investigated. X -ray diffraction was used to determine the phase of the BLT thin films and the quality of the $ZrO_2$ and $CeO_2$ layer. AES show no interdiffusion and the formation of amorphous $SiO_2$ layer is suppressed by using the $ZrO_2$ and $CeO_2$ film as buffer layer between the BLT film and Si substrate. The width of the memory window in the C-V curves for the $BLT/ZrO_2/Si$ and $BLT/CeO_2/Si$ structure is 2.94 V and 1.3V, respectively. The experimental results show that the BLT-based MFIS structure is suitable for non-volatile memory FETs with large memory window.

  • PDF

무선 ad hoc 네트워크에서 IEEE 802.11의 power management scheme에 관한 성능 분석 (Throughput Analysis of Power Management Scheme of IEEE 802.11 DCF in Wireless Ad Hoc Networks)

  • 이감록;권욱현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.61-62
    • /
    • 2006
  • In this paper, using Bianchi's model with channel idle probability we analyze performance of power management scheme of IEEE 802.11 DCF according to ATIM window size and number of nodes for wireless ad hoc networks. The analytical results show that, when the number of nodes is given, the selected ATIM window size limits the performance.

  • PDF