• Title/Summary/Keyword: shoulder types

Search Result 363, Processing Time 0.026 seconds

The Domestic Trends of Traditional Korean Medicine Treatments on Frozen Shoulder (동결견의 한의학적 치료에 대한 국내 연구 동향)

  • Son, Seol-Ki;Kim, Jong-Su;Kim, Shin-Woong;Yoo, Su-Bin;Moon, Byung-Heon;Lee, Cha-Ro
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.9 no.1
    • /
    • pp.55-65
    • /
    • 2014
  • Objectives : The purpose of this review is to investigate the trends of traditional korean medicine treatments on frozen shoulder. Methods : We investigated the studies on traditional korean medicine treatments for frozen shoulder via searching 6 Korean web databases. As a result, 32 research papers were found to be analyzed according to their published year, the titles of journals, published institution, the types of study, the number of cases, the types of treatments, the instruments for assessment and ethical approvals. Results : 32 papers were published since 1989. The studies on traditional korean medicine treatments about frozen shoulder were mainly published in The journal of korean acupuncture & moxibustion medicine. 10 case series, 7 reviews, 6 non-randomized controlled trials, 5 randomized controlled trials and 4 case reports had been under research. In most of the research, the number of the cases were not enough. In 15 cases of the studies, various traditional korean medicine treatments were used to treat the symptoms. In 8 cases of the studies, one method was used to treat the symptoms. Range of motion(ROM) and visual analogue scale(VAS) were used as primary assessments. Among the 25 clinical studies, 5 of them were accepted by institutional review board(IRB). Conclusion : In this study, we analyzed the trends of traditional korean medicine treatments on frozen shoulder. Reviewing the domestic trends of studies on traditional korean medicine treatments for frozen shoulder and examining the strong and weak points of those treatments are essential for the future studies.

  • PDF

Clinical Study about Acupuncture and Moxibustion Treatment according to the different type of the Meridian Pathways of the Patients who have Shoulder Pain (견비통 환자의 경락 유형별 침구 치료에 대한 임상적 고찰)

  • Lee Hee-Yoon;Kim Sang-Heon;Heo Jeong-Eun;Youn Hyoun-Min;Kim Won-Il
    • Korean Journal of Acupuncture
    • /
    • v.23 no.4
    • /
    • pp.67-84
    • /
    • 2006
  • Objectives : This clinical trial is to know how significant the acupuncture treatments are which were done on appropriate acupuncture-points with using method of classification by meridian pathways along the parts of the shoulder pain. Methods : 27 shoulder pain patients who participated in the clinical study in the Bukpyeoung haemalkeun oriental medical clinic which is located in Donghae city were classified 3 types(Yangmyeng, Soyang, Taeyang meridian type) according to their different parts of the shoulder pain. They have been acupunctured in their applied acupoints in the body 3 times a week for 4 weeks. Results : After 4 weeks of the treatments, there were statistically meaningful treatment effect in all index in Yangmyeng meridian type. In Soyang meridian type, there were statistically meaningful treatment effect in 'subjective symptom of shoulder pain','shoulder pain and disability index', 'visual analog scale'. In Taeyang meridian type, statistically effective treatment result was found in 'shoulder pain and disability index' Conclusions : Every type has statistically meaningful treatment effects according to the analysis of the results.

  • PDF

Bag Preference of Men according to their Age and Gender-role Identity Types (남성의 연령과 성역할 정체감 유형에 따른 가방 선호도)

  • Lee, Young-Ju
    • Fashion & Textile Research Journal
    • /
    • v.13 no.1
    • /
    • pp.82-90
    • /
    • 2011
  • This study examines if men in the 20's and 30's have different preference for bag types according to their age and gender-role identity types in order to provide foundational data for the male bag market to segment its customers and establish marketing strategies. Total 288 questionnaire sheets were distributed to 186 men in the 20's and 102 men in the 30's residing in Busan. First, according to the result of analyzing their preference for bag types, adult men in the 20's and 30's preferred cross bags the most. It was also shown that men who are feminine or androgynous prefer back packs, shoulder bags, and tote bags to the other two types. Second, about cross bags, men in the 20's showed a higher rate of having two or three than those in the 30's. Men in the 20's possessed back packs more than those in the 30's. And men tend to show a lower rate of having shoulder bags compared with that of cross bags or back packs. Men in the 30's possessed briefcases more than those in the 20's. Masculine men had more briefcases than the other types of bags, and androgynous men tend to have more tote bags than the other types of bags. Third, men in the 20's and 30's all deemed that back packs go well with the casual style. Men in the 20's regarded shoulder bags are the type of bags that harmoniously matches all styles including casual or semi-suit; however, men in the 30's think they only suit casual or semi-suit. And it was also found that men in the 20's think briefcases are the type of bags that goes well with various styles of clothes while men in the 20's consider they are the type of bags only matching suits.

Generation of 3-dimensional isocomfort workspace using the robot kinematics (로보트 기구학을 이용한 3차원 등편의 작업영역의 생성)

  • 기도형
    • Journal of the Ergonomics Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.11-21
    • /
    • 1997
  • The purpose of this study is to obtain 3-dimensional isocomfort workspace using the robot kinematics, which is based on perceived discomfort in varying postures for manipulating four types of controls. Fifteen healthy male subjects participated in the experiment where their perceived discomfort in the given postures was measured, in which L32 orthogonal array was adopted. The shoulder flexion and adduction-abduction, elbow flexion, types of controls, and right/left hands were selected as experimental variables. The results showed that the shoulder flexion and adduction-abduction, elbow flexion, and types of controls significantly affected the perceived discomfort at .alpha. =0.01. Depending upon the types of control used, regression equations predicting perceived dis- comfort and three dimensional isocomfort workspace were suggested based on the experiemntal cata. Using the equations, driver's isocomfort workspace in his/her cabin for pushing operation was illustrated, in which the robot kinematics was employed to describe the translational relationships between the upper arm and the lower arm/hand. It was ecpected that isocomfort workspace could be used as a valuable guideline to design workplaces ergonomically.

  • PDF

The effect of ultrasonic vibration on bond strength of cemented crown according to margin types and cements (초음파 진동이 주조금관의 변연형태와 시멘트의 결합강도에 미치는 영향)

  • Lee, Yun-Kyung;Bang, Mong-Sook;Park, Ha-Ok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.225-233
    • /
    • 2002
  • This study was aimed to evaluate the effects of ultrasonic vibration on margin types and cements by comparing bond strength of cemented crown. In this study, margins of each metal die, which were chamfer, shoulder and shoulder with bevel, were prepared using computer milling machine. Specimens were cemented with zinc phosphate cement or resin cement. The specimens were divided by the finish line and cement used, ultrasonic vibration. I made total 84 specimens. All specimens were divided into two groups. One group was not vibrated, the other group was subjected to ultrasonic vibration for 12 minutes. Tensile bond strength was measured using Universial testing machine. The changes of bond strength in groups were statistically analyzed by t-test or One-way ANOVA. The results were as follows : 1. Ultrasonic instrumentation diminished the bond strength of crown cemented with zinc phosphate cement and resin cement after 12 minutes application. 2. In case of zinc phosphate cement, the bond strength of a vibrated group was showed significantly decreased(p<0.05). In vibrated groups with zinc phosphate cement, shoulder with bevel exhibit a significant difference to chamfer and shoulder(p<0.05) 3. Resin cement was more resistant to ultrasonic vibration than zinc phosphate cement and showed no significant differences according to ultrasonic vibration and margin type. In conclusion, These results revealed that zinc phosphate cement was most affected and resin cement was the least affected by ultrasonic vibration. Especially shoulder with bevel design was most affected in zinc phosphate cement groups. we should consider these results and be taken in the application of ultrasonic vibration to any teeth restored with crowns.

Clinical Outcome after Surgical Treatment of Recurrent Shoulder Dislocation with Small Bony Bankart

  • Kim, Jung-Han;Kim, Chang-Wan
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.3
    • /
    • pp.144-151
    • /
    • 2015
  • Background: The consensus is that a bony Bankart lesion shorter than 25% of the length of glenoid does not affect the clinical result; hence, such lesions were often neglected. However, small bony Bankart lesions are associated with various types of capsulolabral lesions. Methods: A total of 82 patients who had undergone arthroscopic capsulolabral lesion repair surgery for anterior shoulder dislocation were reviewed. The prevalence rates of early and late type of capsulolabral lesions were compared between a group of patients with and a group without small bony Bankart lesions. In addition, the types of accompanying capsulolabral lesion were analyzed according to the type of bony Bankart lesion. Finally, the clinical outcomes were evaluated (active range of motion, American Shoulder and Elbow Surgeons score and Rowe's score). Results: Among the 13 patients who had small bony Bankart lesions, the prevalence rate of early and late type of capsulolabral lesions was 38.5% and 61.5%, respectively. Among the 69 patients without bony Bankart lesion, the prevalence rates of early and late type of capsulolabral lesions were 74% and 26%, respectively. Significantly worse clinical outcome was observed for the group of patients with both small bony Bankart lesions and late type of capsulolabral lesion. Conclusions: More severe type of small bony Bankart lesion appears to be associated with late type of capsulolabral lesion. The significantly worse clinical outcome for patients with both small bony Bankart lesion and late type of capsulolabral lesion indicates that small bony Bankart lesions cannot always be neglected.

A STUDY ON THE FRACTURE STRENGTH OF THE IPS-EMPRESS CERAMIC CROWN ACCORDING TO MARGIN TYPE (IPS-Empress 도재관의 변연형태에 따른 파절강도에 관한 연구)

  • Kim, Hyun-Soo;Ju, Tae-Hun;Oh, Sang-Chun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.296-307
    • /
    • 1997
  • The purpose of this study was to compare the fracture strength of the IPS-Empress ceramic crown according to margin types such as bevel, shoulder, rounded shoulder, shoulder with bevel, rounded shoulder with bevel and bevel with groove. After 10 metal dies were constructed for each group, the IPS-Empress ceramic crown were fabricated and each crown was cemented on each metal die with Bistite resin cement. The cemented crowns mounted in the testing jig were inclined 30 degree and universal testing machine (Zwick 1456 41, Zwick Co., Germany) was used to measure the fracture strength. The obtained results were as follows : 1. The fracture strength of the crown with rounded shoulder was the highest of all. The mean fracture strength was 484N in rounded shoulder, 357N in bevel, 341N in rounded shoulder with bevl, 300N in shoulder with bevel, 280N in shoulder and 275N in bevel with groove. 2. The fracture strength of rounded shoulder was statistically different from those of shoulder with bevel, shoulder and beve41 with groove. 3. In the strain at fracture, there was no significant difference among each group. 4. The fracture mode of the crown was similar and most of fracture line began at the loading area and extended through proximal surface perpendicularly to the margin, irrespective of margin type.

  • PDF

A Study on Classification of Bodytype of Elderly Males for Upper Garments Construction (상의 구성을 위한 노년기 남성의 체형 분류)

  • 이선명
    • The Research Journal of the Costume Culture
    • /
    • v.1 no.2
    • /
    • pp.159-179
    • /
    • 1993
  • The purpose of this study is to collect data for he improvement of the accuracy of upper garments construction of the old whose bodies have been changed due to their age. In this study the body measurements with 61 items were taken from 226 men(aged fro m 60 to 80) living in Seoul by the R. Martin's method in 1992. The data were calculate by computer and analyzed by the multivariate method, especially factor and cluster analysis. The results of the study were as follows; 1. The average stature of elderly males was 163.6cm, chest circumference 91.6cm, waist circumference 9\\85.5cm. hip circumference 92.8cm, neck circumference 37cm, arm length 55.4 cm, back length 42.6cm, shoulder breadth 42.9cm and the Roher's Index 1.39, which was a standard body shape. 2. The items of factor analysis were explained to seven, namely, the degree of fatness of the upper body, the size of the frame of body, the length of the upper body, the degree of curve of the front body, the size of shoulder, the shape of the back, and the slope of shoulder. 3. The body types of subjects were classified into four types. The majority was type 4, which was 67% of subjects and considered as balanced body type. The distinctive features of those types are as follows; Type 1. The subjects of this type had a slight skeletal structure and were the thinnest of all the subjects with thin and forward-bent arm. Type 2. The subjects of this type were the tallest of all the subjects. they had the straightest side of body and a well-developed upper arm. The thigh length of this type was longer than the length of trunk. Type. 3. The subjects of this type was only one, so ti could be excluded. Type 4. The subjects of this type had a long trunk, well-developed shoulder, and a crook in their neck and back. The arm length and thigh of this type were short and those circumferences were thick. Type 5. The subjects of this type were the shortest of all, but had the highest degree of fatness in the waist and abdominal. They had well-developed front muscles of body and projected hip.

  • PDF

Classification on the Upper Trunk Shapes of the Women in 20-30s by Tight Fitting Technique (입체재단법을 이용한 20-30대 여성의 상반신 유형분류)

  • Seong, Wha-Kyoung;Han, Mi-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.3
    • /
    • pp.349-361
    • /
    • 2008
  • The purpose of this study was to develop bodice basic patterns fitted on different body types of adult women. To meet this purpose, first, human bodies were measured using tight fitting technique and classified based on the shapes of upper trunk. The subjects were 214 women $20{\sim}39$ years of age. For the measurement of female upper trunk, tight fitting technique was utilized. The development of figures of upper trunks were obtained from women. These development of figures were then digitized and analysed using the PAD system. A total of 155 measurements were taken from each of the development of figures. then, 32 measurements were selected for the further analysis. As complimentary data, 22 direct body measurements using an anthropometric method and 23 body measurements using a photographic method from the side view pictures of the participants were also obtained. The results and discussions of this study are as follows: Using the body measurements from the development of figures, a factor analysis and a cluster analysis were conducted. As a result, the body types were classified into 5 different types, which differ in terms of bust volumes, shoulder slopes, shoulder tilts, back silhouettes, body axises. The prominent characteristics of each type are as follows: The first type has a large bust volume. The second type has a right figure. The third type has a rounded back silhouette. The fourth type has a back silhouette of scapular coming backward. Finally the fifth type has a shoulder tilted forward.

The Effects of Trapezius and Serratus Anterior Strengthening Exercise on Pain and Muscle Activation in Spinal Cord Injury Patients with Functional Shoulder Impingement Syndrome (승모근과 전거근 강화운동이 기능적 어깨충돌증후군을 가진 척수손상 환자의 통증과 근 활성도에 미치는 영향)

  • Kim, Sang-Chul;Lee, Young-Min;Shin, Kyu-Hyun
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.33-42
    • /
    • 2018
  • Purpose: The aim of this study was to investigate the effects of trapezius and serratus anterior strengthening exercise on the shoulder pain and muscle activation of patients with spinal cord injury and functional shoulder impingement syndrome. Methods: The study consisted of 10 patients with spinal cord injury who were hospitalized in Rehabilitation Hospital U, Uijeongbu, South Korea. The exercise was implemented three times a week for 10 weeks. In each session, the subjects performed one of a total of five types of exercise at mid-level intensity. The shoulder pain and disability index (SPADI) was used to evaluate the patients before and after the intervention. The muscle activation of the upper trapezius, middle trapezius, lower trapezius, and anterior serratus muscle was assessed by surface electromyography (EMG) at the beginning of the experiment and 10 weeks later. Wilcoxon's singed-rank test was conducted to determine differences in the pain index and muscle activation before and after the exercise. The level of statistical significance was set at ${\alpha}=0.05$. Results: SPADI scores significantly decreased after the exercise (p<0.05). In comparisons of muscle activation, there was a significant improvement in the upper trapezius at $60^{\circ}$ shoulder joint flexion (p<0.05). There was no significant improvement at $90^{\circ}$ shoulder joint flexion. The middle trapezius showed a significant improvement at $120^{\circ}$ shoulder joint flexion (p<0.05). Conclusion: Trapezius and serratus anterior strengthening exercise reduced pain in spinal cord injury patients with functional shoulder impingement syndrome. The decreased muscle activation of upper trapezius and increased muscle activation of the anterior serratus muscle at $60^{\circ}$ shoulder joint flexion point to positive effects of the exercise on supraduction of the scapula.