• Title/Summary/Keyword: shot blast

Search Result 27, Processing Time 0.028 seconds

Microstructural Characterization of SS304 upon Various Shot Peening Treatments

  • He, Yinsheng;Li, Kejian;Cho, In Shik;Lee, Chang Soon;Park, In Gyu;Song, Jung-il;Yang, Cheol-Woong;Lee, Je-Hyun;Shin, Keesam
    • Applied Microscopy
    • /
    • v.45 no.3
    • /
    • pp.155-169
    • /
    • 2015
  • Plastic deformation was introduced to the austenitic (${\gamma}$) stainless steel of SS304 by air blast shot peening, ultrasonic shot peening, and ultrasonic nanocrystalline surface modification. Various deformation structures were formed. The hardness, the deformation structure and the underlying grain refinement mechanism were investigated. In the deformed region, planar dislocation arrays and deformation twin (DT), the DT-DT intersection and ${\varepsilon}$-martensite structures, and ${\alpha}^{\prime}$-martensite were formed in the respective regions of low, medium, and high strain. The grain refinement mechanism is found to be closely related to the 1) sub-division of coarse grains by DT, shear bands and their intersection, and 2) formation of nano-sized ${\alpha}^{\prime}$-martensite due to the high plastic deformation.

Cavitation Erosion Behavior in Seawater of Shot Peened Gray Cast Iron (쇼트피닝 처리된 회주철의 해수 내 캐비테이션 침식 손상 거동)

  • Park, Il-Cho;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.111-111
    • /
    • 2017
  • 쇼트피닝 기술은 크게 피로강도 향상을 위한 쇼트피닝(shot peening), 재료의 청정 및 도장 품질 향상을 위한 쇼트블라스트(shot blast) 그리고 쇼트피닝 시 판재의 변형되는 성질을 이용한 핀포밍(peen forming) 등으로 구분할 수 있다. 그 중 본 연구에서는 해양산업 분야에서 널리 사용되는 회주철의 효과적인 내구성 향상을 위해 쇼트피닝 기술을 적용하였다. 그러나 쇼트피닝 기술 적용에 있어서 가장 중요한 것은 제품의 균일성, 정확성, 신뢰성을 확보하기 위해 쇼트피닝 강도를 제어하는 여러 가지 변수들에 대하여 최적 상태를 유지하는 것이다. 따라서 회주철에 대한 최적 쇼트피닝 분사조건 규명작업은 반드시 쇼트피닝 가공 전에 수반되어야만 한다. 그 일환으로 실험은 쇼트피닝 분사시간과 분사압력을 변수로 하여 회주철 표면에 적용하였으며, 기계적 특성 평가를 통해 최적의 쇼트피닝 조건을 규명하고자 하였다. 쇼트피닝 분사조건에 따른 회주철의 내구성을 평가하기 위해 캐비테이션 실험을 실시하였으며, 경도 측정, 횡단면 관찰 및 표면의 3D 현미경 관찰 등을 통해 기계적 특성을 분석하였다. 캐비테이션 실험은 ASTM G32 규정에 의거하여 천연해수 내 $30^{\circ}C$에서 $50{\mu}m$의 진폭으로 실시하였다. 실험 후에는 주사전자현미경으로 손상표면을 관찰하였으며, 손상 정도를 비교하기 위해 무게 감소량을 계측하여 상호 비교/분석하였다.

  • PDF

Design, Fabrication and Performance Testing of a High-impulse, Low-Power Microthruster using Liquid Propellant with High Viscous Fluid Plug (저전력소비, 고출력, 연발형 마이크로 분사기의 설계, 제작 및 성능 시험)

  • Kim, Sang-Wook;Kang, Tae-Goo;Cho, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.59-63
    • /
    • 2001
  • A high-impulse, low-power, continuous-shot microthruster has been developed using low boiling temperature liquid-propellant with high viscous fluid-plug. The viscous friction force of the fluid-plug increases the blast pressure and the low boiling temperature liquid-propellant is intended to reduce input power consumption. The three-layer microthruster has been fabricated by surface micromachining as well as bulk micromachining in the size of $7{\times}13{\times}1.5mm^{3}$. A continuous output impulse bit of $6.4{\times}10^{-8}N{\cdot}sec$ has been obtained from the fabricated microthruster using perfluoro normal hexane (FC72) propellant and oil plug, resulting in about ten times increase of the impulse bit using one hundredth electrical input energy compared to the conventional continuous microthruster.

  • PDF

clinical analysis of vascular trauma (혈관손상의 임상적 고찰)

  • 성숙환
    • Journal of Chest Surgery
    • /
    • v.19 no.2
    • /
    • pp.288-294
    • /
    • 1986
  • During the period from Mar. 1983 to Feb. 1986, 22 patients with vascular trauma were treated at Capital Armed General Hospital. 1] 11 patients had arterial injury alone, 6 patients had venous injury alone, and 5 patients had both arterial and venous injuries. 2] The mechanism of injury in these 22 patients was 7 penetrating non-gun shot wounds, 5 blast fragments injuries, 4 iatrogenic injuries, 4 blunt injuries, 2 gun shot wounds. 3] The method of 16 arterial repair was 5 autogenous saphenous vein graft, 8 synthetic vascular graft, 1 end to end anastomosis, 2 lateral suture. Midterm patency of 16 repairs was 100% within 1 months. 4] The method of 11 venous repair was 1 autogenous saphenous vein graft, 2 onlay vein patch, 2 ligation, 1 lateral suture. The thrombotic obstructions occurred in 4 repairs [36.4%], but they were resolved somewhat with heparinization. 5] Uncommon cases of false aneurysm of internal carotid artery and laceration of retrohepatic inferior vena cava were summarized.

  • PDF

단조품 후처리 공정의 작업환경 개선을 위한 공정자동화 시스템 개발

  • 송신우;하인철;송병석;이경돈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.282-282
    • /
    • 2004
  • 단조품 후처리 공정은 표면처리, 자분 탐상, 수 검사, 방청, 개수계량 공정으로 이루어져있다. 그러나 우리나라의 단조품 제조 산업에서는 Fig. 1에서 보는 바와 같이 후처리 공정이 작업자의 수작업으로 이루어져 있어서 많은 문제점을 가지고 있다. 표면 처리 공정에서 소재를 장입하는 작업은 작업자의 수작업으로 이루어져 있어서, 작업자는 중량물을 개수하고, 버킷에 담는 작업을 수행해야 한다. 또한, 소재의 이송은 지게차를 이용하고 있어 작업자와 지게차는 같은 작업공간에서 작업을 하게 된다.(중략)

  • PDF

Slip Behavior of Friction Type High-Tension Bolted Joints with Oversize Hole (과대공을 갖는 고장력 볼트 마찰이음부의 미끄러짐 거동)

  • Cho, Sun Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.301-307
    • /
    • 1997
  • In field fabrication of steel members, the oversize hole is frequently required due to reaming and mismatching. But, there are no provisions and investigations about oversize hole in the Korean specifications. So, in this study, the tension test of friction type high-tention bolted joints is performed with parameters of bolt hole size, surface treatment and tightening force, and investigate the effect of slip behavior with those parameters. From the results, the enough tightening force is needed to obtain some degree slip load in shot blast treatment case, although tightening force is reduced somewhat, it is no problem to guarantee slip load in zincrich primer case. The slip behavior of joints with oversize hole(26mm) is similar to the slip behavior of joints with hole of nominal size.

  • PDF

Designing An Effective siRNA (효과적인 siRNA의 디자인)

  • Gu, Nam-Jin;Jo, Gwang-Hwi
    • Bioinformatics and Biosystems
    • /
    • v.2 no.1
    • /
    • pp.17-23
    • /
    • 2007
  • Shot interfering RNA (siRNA) can be used to silence specific gene expression and have many potential therapeutic applications. However, how to design an effective siRNA is still not clear. Highly effective siRNA has sequence-specific properties which are low G/C content, low internal stability at the sense strand 3'-terminus, sense strand base bias(position 1 is G/C, position 19 is /AU). Recently, mRNA secondary structure playsan important role in RNAi. Target site of siRNA in high-ordered structure (i.e hairpin loop, multi loop) or base pair of many hydrogen bonds dramatically reduce function of siRNA mediated gene silencing. Possible off-target effects of siRNA is detecting from BLAST search.

  • PDF

High-impulse, Low-Power Microthruster using Liquid Propellant with High-Viscosity Fluid Plug (저온 비등 팽창유체와 고점성 유체마개를 이용한 고출력 저전력형 마이크로 분사기)

  • Kim, Sang-Wook;Kang, Tae-Goo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.868-874
    • /
    • 2002
  • A high-impulse, low-power, digital microthruster has been developed using low-boiling-temperature liquid propellant with high-viscosity fluid plug. The viscous fiction force of the fluid plug increases the blast pressure and the low-boiling-temperature liquid propellant is intended to reduce input power consumption. The three-layer microthruster has been fabricated by surface micromachining as well as bulk micromachining in the size of 7$\times$13$\times$1.5㎣. A digital output impulse bit of 6.4$\times$10$^{-8}$ Nsec has been obtained from the fabricated microthruster using perfluoro normal hexane (FC72) propellant and oil plug, resulting in about ten times increase of the impulse bit using one hundredth electrical input energy compared to the conventional multiple-shot microthruster.

A Study on the Characteristics of High-Tension Bolted Joints' Behavior due to Surface Condition (표면상태에 따른 고장력볼트 마찰이음부의 거동특성에 관한 연구)

  • Cho, Sun Kyu;Hong, Sung Wook
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.3 s.32
    • /
    • pp.421-430
    • /
    • 1997
  • In this study, the static and the fatigue tests were performed with high tension bolted joints, of which the surfaces were spread with inorganic zinc-primer after shot-blast, and milling surface, and steel-natural surface, difference of friction surface condition were examined by comparing the esults of tests. From the result of synthetical investigation of this study. it is proper that using the torque management method in order to introduce design axial force to blots, and the provision of specifications that initial axial forces must be 110% of design axial forces is proper. Decreasing ratio of axial forces to initial force is proportional to common lorgarithms of time progress, it converge constant value after 20 hours, and decreasing ratio is little related to the roughness of friction surface. Sliding coefficient of milling, spreading inorganic zinc-primer, just producting is great in order and sliding forces are dependent on the applied axial forces, but if the applied axial forces are great, sliding coefficient become small by a loss of roughness. So it is confirmed that relation between the applied axial forces and the sliding forces are not proportional linearly. From the result of estimation on fatigue strength, all specimens satisfy the specifications with B-grade and milling surface is lower than the others about 14% in fatigue strength because in milling surface lose the function of friction-types joints at lower number of cycles. From the result of eximination for the distribution area of compressive force, friction area near to inside bolt is wider in the direction of stress than near to outside. It is guessed that this situation occurs because outside bolts firstly change from the friction connection to the bearing connection.

  • PDF

Evaluation of slip coefficient of slip critical joints with high strength bolts

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Kim, Kang-Seok;Kim, Woo-Bum
    • Structural Engineering and Mechanics
    • /
    • v.32 no.4
    • /
    • pp.477-488
    • /
    • 2009
  • A slip critical joint has various values to adopt the proper slip coefficient in various conditions of faying surfaces in the following codes: AISC, AIJ and Eurocode 3. However, the Korean Building Code still regulates the unique slip coefficient, 0.45, regardless of the diverse faying conditions. In this study, the slip resistance test, including five kinds of surface treatments were conducted to obtain the proper slip coefficients available to steel plate KS SM490A. The faying surfaces were comprised of a clean mill, rust, red lead paint, zinc primer, and shot blast treatment. The candidates for high strength bolts were torque-shear bolts, torque-shear bolts with zinc coating, and ASTM A490 bolts. Based on the test results, the specimens with a shot blasted surface and rusted surface exhibited $k_s$, 0.61, and 0.5, respectively. It is recommended that the specimens with zinc primer exhibit $k_s{\geq}0.40$. The clean mill treated surface had prominently lower values, 0.27. For red lead painted treatment, the thickness of the coating affects the determinant of slip coefficient, so it is necessary to establish a minimum $k_s$ of 0.2, with a coating thickness of 65 ${\mu}m$. During 1,000 hours of relaxation, the uncoated surfaces exhibited the loss of clamping force behind 3%, while the coated surfaces within a certain limited thickness exhibited the loss of clamping within a range of 4.71% and 8.37%.