• Title/Summary/Keyword: shock absorption performance

Search Result 39, Processing Time 0.025 seconds

Performance Estimation of Hexagonal Rockfall Protection Net by Numerical Analysis (수치해석을 이용한 육각 낙석방지망의 성능 평가)

  • Oh, Sewook;Park, Soobeom;Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.11
    • /
    • pp.53-59
    • /
    • 2014
  • It has been generally recognized that the conventional rockfall protection nets have several problems to actual field application in the aspect of shock absorption, lack of pullout bearing capacities, and net damages. Because of the recognition, authors have tried to develop a new rockfall protection system consisted of shock absorption parts and hexagonal net configuration. In the previous research by the authors, the performance of the newly developed rockfall protection system has been investigated through the laboratory tests and the full-scale testing. In this study, subsequently, numerical analysis program is organized to make a confirmation of the structural stability and performance. For the correct design procedure of the hexagonal net system, it is essential to understand the various mechanical behavior of the entire system. It is also important to be reproduced the systematic characteristics of the system acquired by laboratory and full-scale testing by numerical analysis in order to carry out the numerical experiment to understand various mechanical behavior of the system. As a conclusion, the hexagonal net has better performance in mechanical and physical behavior compared with that of the rectangular net. Furthermore, due to the hexagonal net shows a good performance in aspect of the load distribution, it gives a good alternative in long-term management of the rockfall protection net.

Explosion Resistance Performance of Corrugated Blast Walls for Offshore Structures made of High Energy Absorbing Materials (고에너지흡수 신소재 적용 해양플랜트 파형 방폭벽의 폭발 저항 성능)

  • Noh, Myung-Hyun;Park, Kyu-Sik;Lee, Jae-Yik
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • In this paper, a finite element dynamic simulation study was performed to gain an insight about the blast wall test details for the offshore structures. The simulation was verified using qualitative and quantitative comparisons for different materials. Based on in-depth examination of blast simulation recordings, dynamic behaviors occurred in the blast wall against the explosion are determined. Subsequent simulation results present that the blast wall made of high energy absorbing high manganese steel performs much better in the shock absorption. In this paper, the existing finite element shock analysis using the LS-DYNA program is further extended to study the blast wave response of the corrugated blast wall made of the high manganese steel considering strain rate effects. The numerical results for various parameters are verified by comparing different material models with dynamic effects occurred in the blast wall from the explosive simulation.

Design and Implementation of Vibration Isolation System for Mobile Doppler Wind LIDAR

  • Song, Xiaoquan;Chen, Chao;Liu, Bingyi;Xia, Jinbao;Stanic, Samo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.103-108
    • /
    • 2013
  • The operation of a Doppler wind LIDAR in a mobile environment is very sensitive to shocks and vibrations, which can cause critical failures such as misalignment of the optical path and damage to optical components. To be able to stabilize the LIDAR and to perform wind field measurements in motion, a shock absorption and vibration isolation system was designed and implemented. The performance of the vehicle-mounted Doppler wind LIDAR was tested in motion, first in a circular test route with a diameter of about 30 m and later in regular expressway traffic. The vibration isolation efficiency of the system was found to be higher than 82% in the main vibration area and shock dynamic deflection was smaller than maximal deflection of the isolator. The stability of the laser locking frequency in the same mobile environment before and after the vibration isolation system installation was also found to be greatly improved. The reliability of the vibration isolation system was confirmed by good results of the analysis of the LIDAR data, in particular the plane position indicator of the line of sight velocity and the wind profile.

Dynamic Characteristics Stiffened Blast-wall Structures Subjected to Blast Loading Considering High Strain-rate Effects (고속 변형률속도 효과를 고려한 폭발하중을 받는 보강형 방폭벽 구조의 동적 특성)

  • Kim, Gyu Dong;Noh, Myung Hyun;Lee, Jae Yik;Lee, Sang Youl
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.65-74
    • /
    • 2016
  • A finite element dynamic simulation is performed to gain an insight about the stiffened blast wall structures subjected to blast loading. The simulation was verified using qualitative and quantitative comparisons for different materials. Based on in-depth examination of blast simulation recordings, dynamic behaviors occurred in the blast wall against the explosion are determined. Subsequent simulation results present that the blast wall made of the high performance steel performs much better in the shock absorption. In this paper, the existing finite element shock analysis using the LS-DYNA program is further extended to study the dynamic response of the stiffened blast wall made of the high-performance steel considering high strain-rate effects. The numerical results for various parameters were verified by comparing different material models with dynamic effects occurred in the stiffened blast wall from the explosive simulation.

Study on the Reliability of COB Flip Chip Package using NCP (NCP 적용 COB 플립칩 패키지의 신뢰성 연구)

  • Lee, So-Jeong;Yoo, Se-Hoon;Lee, Chang-Woo;Lee, Ji-Hwan;Kim, Jun-Ki
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.25-29
    • /
    • 2009
  • High temperature high humidity and thermal shock reliability tests were performed for the board level COB(chip-on-board) flip chip packages using self-formulated and commercial NCPs(non-conductive pastes) to ensure the performance of NCP flip chip packages. It was considered that the more smaller fused silica filler in prototype NCPs is more favorable for high temperature high humidity reliability. The failure of NCP interconnection was affected by the expansion of epoxy due to moisture absorption rather than the fatigue due to thermal stress. It was considered that the NCP having more higher adhesive strength seems to be more favorable to increase the thermal shock reliability.

  • PDF

Design of a Variable-Stiffness Type Safety Joint for Service Robots (서비스 로봇용 가변강성 형 안전관절의 설계)

  • Jeong, Jae-Jin;Chang, Seung-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.128-134
    • /
    • 2009
  • This paper aims to design a variable-stiffness type economical safety joint for service robots. The safety joint was designed to have a passive shock absorbing mechanism for protecting human from a catastrophic collision under service condition of robots. A simple mechanism composed of two action disks for switching the load transfer, a spring and a screw for pre-load was proposed. In order to evaluate the performance of the safety joint a testing platform which can carry out the static and impact tests was also designed and fabricated. From the test results, the designed safety joint was proved to have a variable load-carrying capacity and about 42% impact absorption capacity with simple manipulation of the control screw.

Optimization and sensitivity analysis of the humanoid robot's foot using the design of experiments (실험계획법에 의한 휴머노이드 발의 민감도 해석 및 최적화)

  • Yoon, Ji-Won;Park, Tae-Won;Jung, Sung-Pil;Park, Joong-Kyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.933-938
    • /
    • 2007
  • These days, up-to-date humanoid robots are continuously developed. Among them, Qrio, Asimo[1,2] are famous for its unique walking technology and natural movement. These robots could show manufacturers' technological improvement and leave a good impression to the customer. In accordance with global trends, Samsung is also producing humanoid robot. The humanoid robot, however, could walk like a human compared to the industrial robot fixed in the factory. This feature could cause another dynamic effect while walking. In this paper, the robot's feet were examined to find out parameters that affect stability of the humanoid robot's feet. With the sensitivity analysis, the optimization procedure in design of experiments finds the most suitable performance of robot. Maximum deflection of the frame upon various cases was minimized, and rubber coefficients for shock absorption were optimized.

  • PDF

Experimental study on seismic performance of concrete filled tubular square column-to-beam connections with combined cross diaphragm

  • Choi, Sung-Mo;Yun, Yeo-Sang;Kim, Jin-Ho
    • Steel and Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.303-317
    • /
    • 2006
  • The connection with combined cross diaphragm is developed for the connection of square CFT column and steel beam and proposed to be used for the frame with asymmetric span length. The structural characteristics of this connection lie in the penetration of the beam flange in the direction of major axis through the column for the smooth flow of stress. The purpose of this study is to analyze the dynamic behavior and stress flow of suggested connection and to evaluate the resistance to shock of connection. Four T-type CFT column-to-beam specimens; two with combined cross diaphragm and the others with interior and through diaphragms, the existing connection types, were made for cyclic load test guided by the load program of ANSI/AISC SSPEC 2002. The results show that the proposed connection is more efficient than existing ones in terms of strength, stress flow and energy absorption and satisfies the seismic performance required in the region of weak/moderate earthquakes.

Development of an Advanced Oil Deflector Used in Thermoelectric Power Plant (화력발전소에 사용되는 개선된 오일 디플렉터 개발)

  • Choi, Yong Hoon;Kwak, Hyo Seo;Lee, Chang Ryeol;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.8
    • /
    • pp.661-668
    • /
    • 2016
  • Oil deflector prevents oil leakage that occurs in thermoelectric power plant at operating lubricant facilities. Vibration of rotating rotor-induced wear of aluminum tooth in existing oil deflector leads to oil leakage as well as life shortening of the tooth. In this study, an advanced oil deflector was developed for shock absorption and prevention of wear by decreasing clearance (from 0.5 mm to 0.2 mm) between rotor and tooth to minimize oil leakage, and by replacing 2 aluminum teeth in outmost of the oil deflector with hi-performance seal made of engineering plastic. The CFD results were compared between advanced vs. existing oil deflector to determine the amount of oil loss. Structural safety was verified through impact analyses according to the three kinds of engineering plastics, considering cost efficiency, and optimal material of hi-performance seal was chosen.

Seismic performance of hybrid isolation plate-shell integrated concrete LSS

  • Lei Qi;Xuansheng Cheng;Shanglong Zhang;Yuyue Bu;Bingbing Luo
    • Earthquakes and Structures
    • /
    • v.27 no.1
    • /
    • pp.57-67
    • /
    • 2024
  • To assess the seismic performance of Plate-Shell Integrated Concrete Liquid-Storage Structure (PSICLSS), a scaled test model was constructed. This model incorporated a hybrid isolation system, which combined shape memory alloy (SMA), lead-cored rubber isolation bearing (LRB) and sliding isolation bearing (SB). By conducting shaking table test, the dynamic responses of both non-isolated and hybrid-isolated PSICLSS were analyzed. The results show that the hybrid isolation system can effectively reduce the acceleration and displacement responses of the structure. However, it also results in an increase in local hydrodynamic pressure and liquid sloshing height. Under extreme earthquake action, the displacement of isolation layer is small. When vertical ground motion is taken into account, the shock absorption rate of horizontal acceleration decreases. The peak hydrodynamic pressure increases significantly, and the peak hydrodynamic pressure position also changes. The maximum displacement of isolation layer increases, the residual displacement decreases.