• 제목/요약/키워드: shin-huh

검색결과 522건 처리시간 0.032초

퍼지논리에 의한 XY 테이블의 위치제어기 설계 (Design of Position Controller for XY table using Fuzzy Logic)

  • 염형선;신기상;신두진;허욱열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.414-416
    • /
    • 1998
  • One significant error in XY table is due to friction and disturbance. However, the characteristics of this friction is not easy to predict and analyze because of its nonlinearity. Therefore, it is difficult for conventional controller to compensate it effectively. In order to solve this problem, this paper presents a position controller based on fuzzy logic controller(FLC) that is suitable for system with unknown and unmodelled dynamics. The performance of the proposed controller are demonstrated by simulation results.

  • PDF

X선영상증배관의 상대변환계수 측정에 관한 검토 (The Study on Measurement of Relative Conversion Factor in X-ray Image Intensifier)

  • 김성철;신성일;이선숙;허준;김성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.28-33
    • /
    • 1997
  • For the Evaluation of X-ray image intensifier, we measured radiation dose at input of I. I., brightness and fluorescence at output of I. I. by using X-ray exposure meter, optometer and fluorescence meter for the relative conversion factor. Especially, by using fluorescence meter, we could easily get relative conversion factor without having regulated machine by JIS. Since using, the quality of image intensifier is going down. Consequently, it needs continuous quality maintenance.

  • PDF

관전압(管電壓)과 황산(黃酸)바륨의 농도(濃度)에 관(關)한 연구(硏究) (Study on the High Tension on Radiography and Density of Barium Sulphate)

  • 경광현;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제3권1호
    • /
    • pp.43-48
    • /
    • 1980
  • An experimental study was carried out to make a comparison between tube voltage and density of barium sulphate in the stomach radiography. The results were summarized as follows: 1. The percentage of density on concentrations of barium sulphate as contrast media could not show in differences with changes of voltages applied X-ray tube. 2. The changes of density visualized on X-ray film mainly depend upon with thickness of stomach filled barium sulphate than the ratio of barium sulphite and plain water volume. 3. The lesions positioned in upper part within stomach exhibited their best discrimination performanance with depth in the low tube voltage, followed in order by the middle part and lower part. However, the discrimination performanance at the high tension radiography uniformly visualized over X-ray film without density in change.

  • PDF

저전압 SR모터의 퍼지로직 기반 전상각 제어 (Fuzzy logic based advance angle control for low voltage SRM)

  • 김규동;신두진;허성재;허욱열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.22-25
    • /
    • 2001
  • In this paper, a fuzzy advance angle control method is described to drive an industrial low voltage SRM (Switched Reluctance Motor) for 10kW forklift truck. SRM has a highly non-linear characteristic that is due to change the rotor and stator. And low voltage SRM is designed that its phase resistance and phase inductance is very low to inject high current into the phase windings. In this reason, the proper current control is necessary to drive the low voltage SRM efficiently. SRM has positive torque at increasing inductance region and negative torque at decreasing inductance region. Due to this reason, the current has to be built up in the increasing phase inductance part as soon as possible. Therefore, the phase switch must be turned on before the phase inductance increases, and this angle is called as the advance angle. Also, the phase current has to be dropped before the phase inductance decreases. Fuzzy logic is a flexible and general-purposed method of implementing non-linear functions and as such it is useful in control applications. Consequently, we designed a fuzzy advance angle controller to control the phase current appropriately.

  • PDF

Induction of Lipin1 by ROS-Dependent SREBP-2 Activation

  • Seo, Kyuhwa;Shin, Sang Mi
    • Toxicological Research
    • /
    • 제33권3호
    • /
    • pp.219-224
    • /
    • 2017
  • Lipin1 was identified as a phosphatidate phosphatase enzyme, and it plays a key role in lipid metabolism. Since free radicals contribute to metabolic diseases in the liver, this study investigated the effects of free radicals on the regulation of Lipin1 expression in Huh7 and AML12 cells. Hydrogen peroxide induced mRNA and protein expression of Lipin1 in Huh7 cells, which was assayed by quantitative RT-PCR and immunoblotting, respectively. Induction of Lipin1 by hydrogen peroxide was confirmed in AML12 cells. Hydrogen peroxide treatment significantly increased expression of sterol regulatory element-binding protein (SREBP)-2, but not SREBP-1. Moreover, nuclear translocation of SREBP-2 was detected after hydrogen peroxide treatment. Hydrogen peroxide-induced Lipin1 or SREBP-2 expression was significantly reduced by N-acetyl-$\small{L}$-cysteine treatment, indicating that reactive oxygen species (ROS) were implicated in Lipin1 expression. Next, we investigated whether the hypoxic environments that cause endogenous ROS production in mitochondria in metabolic diseases affect the expression of Lipin1. Exposure to hypoxia also increased Lipin1 expression. In contrast, pretreatment with antioxidants attenuated hypoxia-induced Lipin1 expression. Collectively, our results show that ROS activate SREBP-2, which induces Lipin1 expression.

Three cases of cholesterol granuloma in the mandible

  • Shin, Min-Jung;Shin, Jae-Myung;Huh, Kyung-Hoe;Yi, Won-Jin;Moon, Je-Woon;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제37권4호
    • /
    • pp.225-230
    • /
    • 2007
  • Cholesterol granuloma is an unusual clinical entity described as an inflammatory granulation in response to the deposit of cholesterol crystals. It can develop in any portion of air cells within the temporal bone as a result of a lack of aeration and inadequate drainage, especially in the middle ear cavity. Here, we report very unusual three cases of cholesterol granuloma developed in mandible. In the first case a 68-year-old male with a large mass arising from the mandible was observed. Panoramic radiograph and computed tomography scans revealed a huge expanding lesion in the mandible. In the second case a 47-year-old female with a cystic lesion in the mandible was observed. And in the third case a 19-year-old male complaining atypical facial pain had a large lesion in the mandibular ramus. The histopathologic examinations of the cases showed numerous cholesterol crystals surrounded by multinucleated foreign body giant cells.

  • PDF

흉부X선사진(胸部X線寫眞)에 나타나는 감감현상(減感現象)에 관(關)한 연구(硏究) (A Study on Appearances of Desensitized Phenomenon in Chest Roentgenography)

  • 경광현;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제2권1호
    • /
    • pp.23-29
    • /
    • 1979
  • Roentgenographic film has to be handled with greatest care during removal from the packing, loading of the cassettes and loading of the hanger. In the case of prior to or after exposed film is handled with mechanical pressure in darkroom, the most common phenomena are desensitization or sensitization on roentgenographic film. In order to observe these defect occurring on, it, the author studied on change of the densities where the mechanical pressure reached to the roentgenographic film. 1. The optimal minimum and maximum densities in routine chest x-ray film are from 0.25 to 1.47 2. The dependence of the desensitization occurring on film upon the bent degree of film is in the portion to bent degree over $10^{\circ}$ 3. Appearances of the desensitization on film by the curved degree of film is inverse proportion to it's degree below intervals of 3cm. 4. The more unexposed film is bent with nail tip and is pressured with palm, the more desensitization it was appeared upon film size and pressure weight. 5. The most serious area of desensitization produced by many types of mechanical pressure is in the portion of lung apex and outside lung fields. 6. The tendency of desensitization due to mechanical pressure on unexposed film is more serious than sensitization on exposed film in the view of radiologic diagnosis.

  • PDF

X선진단(X線診斷) 부문(部門)에 있어서 업무량(業務量)에 관(關)한 조사연구(調査硏究)(I) (A Study on Activities of Diagnostic X-ray Examination(I))

  • 경광현;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제1권1호
    • /
    • pp.37-43
    • /
    • 1978
  • This Study was conducted, during the period of 8-16th, August in 1977 and 27th, January through 2, Feburury in 1978, to measure laking off and on time for patient's clothes at the radiologic department in general hospitals. The study dealt with three general hospitals which were classified into groups by ownerships; two university hospitals, one private hospitals. The scope of the study was limited to measurement's of taking off and on time except taking a radiograph. The results were summarized as follows: [1] In Summer, the average taking off ana on tine for male was 3 minutes and 7 seconds and 3 minutes and 43 seconds for female. The latter was longer than that for the former. [2] In Winter, the mean taking off and on time for male was 3 minutes 42 seconds, 4 minutes 17 seconds for female. [3] In this respect, the average taking off and on time for female was longer than that for male and that for winter was expended that for summer. [4] In Summer, regardless of age group and sex, the average taking off and on time for taking a radiograph was 3 minutes 25 seconds, and 3 minuteds 59 seconds in Winter. [5] Regardless of season, sen, and age, the mean time expended to take off and on for taking a radiograph was 3 minutes 43 seconds.

  • PDF