• Title/Summary/Keyword: sheath current

Search Result 144, Processing Time 0.03 seconds

Structural Differentiation of Photosynthetic Tissue in Kranz Anatomy of Salsola Species (Salsola속 Kranz구조내 광합성조직의 구조분화)

  • Kim, In-Sun
    • Applied Microscopy
    • /
    • v.31 no.4
    • /
    • pp.367-374
    • /
    • 2001
  • Leaves of two developmental stages of Salsola species, young and mature, were examined to reveal the structural and functional relationships in the photosynthetic tissue using anatomical and ultrastructural criteria. Both young and mature leaves had Kranz anatomy of the Salsolid type with two layers of chlorenchyma on the leaf periphery: an outer layer of palisade mesophyll cells and an inner layer of compact bundle sheath cells with centripetally arranged organelles. The chlorenchyma was continuous in young leaves , while it was discontinuous in mature leaves. The main vascular bundle occupied the central position in the leaf. but the small peripheral vascular bundles were in contact with the chlorenchyma. Structural dimorphism of chloroplasts was obvious in bundle sheath cells of mature leaves exhibiting noticeable grana reduction, whereas mesophyll cell chloroplasts had well developed grana in all cases. Plasmodesmata were less numerous and rather simple in young leaves relative to well-developed secondary plasmodesmata of the later stage. According to the current data, features of two stages of Salsola leaves corresponded to NADP-ME bio-chemical subtype on the basis of photosynthetic cell ultrastructure. Implications of developing such anatomical and ultrastructural data of Sulsola species and biochemical characteristics reported in other C-4 species have been discussed.

  • PDF

Low Temperature Thermal Conductivity of Sheath Alloys for High $T_{c}$ Superconductor Tape

  • Park, Hyung-Sang;Oh, Seung-Jin;Jinho Joo;Jaimoo Yoo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.2
    • /
    • pp.32-37
    • /
    • 2000
  • Effect of alloying element additions to Ag on thermal conductivity and electrical conductivity of sheath materials for Bi-Pb-Sr-Ca-Cu-O(BSCCO) tapes has been characterized. The thermal conductivity at low temperature range (10~300K) of Ag and Ag alloys were evaluated by both direct and indirect measurement techniqueas and compared with each other, It was observed that the thermal conductivity decreases with increasing the content of alloying element such as Au, Pd and Mg. Thermal conductivity of pure Ag at 3 0K was measured to be 994.0 W(m.K) on the other hand, the corresponding values of $Ag_{0.9995}Mg_{0.0005}$, $Ag_{0.974}$, $Au_{0.025}$, $Mg_{0.001}$, $Ab_{0.973}$, $Au_{0.025}$, $Mg_{0.002}$ and $Ag_{0.92}$, $Pb_{0.06}$, $Mg_{0.02}$ were 342.6, 62.1, 59.2 and 28.9 W(m.K), respectively, indicating 3 to 30 times lower than that of pure Ag. In addition, the thermal conductivity of pure Ag measured by direct and indirect measurement techniques was 303.2 and 363.8 W(m.K) The difference in this study is considered to be within an acceptable error range compared to the reference data.

  • PDF

A Morphological Study of Bamboos in Mt. Jiri by Vascular Bundle Sheath (지리산(智異山) 죽류(竹類)의 유관속초(維管束鞘)에 의(依)한 형태학적(形態學的) 연구(硏究))

  • Kim, Jai-Saing
    • Journal of Korean Society of Forest Science
    • /
    • v.34 no.1
    • /
    • pp.47-56
    • /
    • 1977
  • I have investigated and compared the morphology of vascular bundle shown in the section of culm wall of bamboo trees growing on Mt. Jiri which were classified by Grosser and Liese with their methods of morphological classification. The results obtained were as follows: 1. It was shown that there are no b.g.i. types of bamboo classified by Grosser and Liese among the bamboo trees on Mt. Jiri (Phyllostachys and Sasa). 2. As for the thickness of the culm wall in the culm, it was shown that the culm wall of the Phyllostachys becomes thinner in proportion to its nearness to the upper part of the tree, but no distinctive difference appeared in the Sasa. 3. The c, d, and e types of Sasa were the same as those of the Phyllostachys, but there was a vascular bundle type of the a' type, which was quite different from that of the Phyllostachys. 4. It was shown that the a', d, and e types of Sasa were distributed in a zone less than 500m above sea level, but no a' type was distributed in the high mountain area except for the c, d and e types which ranged from 600m to 1000m above sea level. Such facts mean that the vascular bundle sheath has changed in quantity because of the height of mountain. 5. In general, as compared with the Phyllostachys, the Sasa (types a, c, d and e which included a new type a) have fewer vascular bundles. 6. Considering the above results, it is thought that not by the current Sasa classification method based on observation of the the study of Sasa form the outside, but by a new method of classification based on the aspect of the physiological construction as seen from the inside wall is advanced. I believe this new method of classification to be a first step towards an epoch-making methodological advance and encourage the further study of it.

  • PDF

A Basic Study for the Fire Potentiality in Wire being Applied Electric Current (통전중인 도선에서 화재 가능성에 관한 기초 연구)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Lee, Chun-Ha;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.72-77
    • /
    • 2009
  • In total electric fire in Korea in 2006, a rate of the electric fire caused of short in electric wire is over 63.2[%]. It is needed to study a fire potentiality in electric wire. This paper studies contact and fire potentiality between a electric wire and conductors existed around the electric wire. As amplitude of current in electric wire is bigger, as it has higher possibility to contact between a electric wire and conductors existed around the electric wire. In case of temperature of wire is over combustion point of outer sheath, it is appeared to spark discharge between wire and conductors. So the fire potentiality raise up.

A Study on the Generation of the Earth Potential and Communication Line Noise (대지전위와 통신회선 잡음.발생에 대한 고찰)

  • Yeo, Sang-Kun;Park, Chan-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.181-189
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

Transient Phenomena Analysis and Estimation According to Unbalance Factors on Underground Power Cable Systems (지중송전계통에서 불평형 구성요소에 따른 과도현상 해석 및 평가)

  • Jung Chae-Kyun;Lee Jong-Beom;Kang Ji-Won;Lee Dong-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.8
    • /
    • pp.410-417
    • /
    • 2005
  • This paper analyses the transient phenomena against single line to ground fault and lightning surge on underground power cable systems. For analysis in various fault conditions, several actual underground power cable systems are modeled using ATP In ground fault, the transient characteristic of the conductor and the sheath according to the fault current and the installation types of CCPU are analysed. In lightning surge strokes, the various unbalanced conditions including the length of crossbonded lead, the breakdown of CCPU and distance unbalance are considered. This paper is expected to contribute the establishment of proper protection methods against transients on underground power cable systems.

Analysis of temperature and energy characteristic of OF Cable (OF 케이블의 온도 및 에너지 특성 해석)

  • Kang, J.W.;Jang, T.I.;Hong, D.S.;Lee, D.I.;Jung, C.K.;Lee, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.721-723
    • /
    • 2005
  • This paper analyses the characteristic of temperature and energy of oil field cable in transient state such as lightning surge. For analysis in various conditions, many actual underground power cable systems are modeled using ATP These results are applied for the examination of temperature increase when the hitting of lightning surge are occurred. The inner part temperature of OF cable is analysed according to the various kinds of cable using the thermal model of transient state. The temperature increase of sheath and crossbonded lead by fault current is also analysed using IEC 60949.

  • PDF

Methodology of Parallel Ground Conductor Installation on Underground Transmission System (지중송전 시스템의 병행지선 설치 방안 연구)

  • Hong, Dong-Suk;Park, Sung-Min;Hahn, Kwayng-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.470-471
    • /
    • 2008
  • SVL is installed at underground transmission system to protect cables and insulation joint-box from overvoltages caused by lightning, switching, and line-to-ground fault. Domestic underground power system adopts cross bonding type to reduce the induced voltage at sheath, but single-point bonding is required depending the system installation configuration. SVL can be easily broken by overvoltages induced at joint-box because single-point bonding has uneffective system structure to extract fault current. ANSI/IEEE recommends Parallel Ground Continuity Conductor(PGCC) to prevent SVL breakdown. In this paper, EMTP simulation is performed to analyze effects on SVL under PGCC installation when single-line-to-ground fault occurs. The result shows that PGCC and short single-point bonding distance can reduce overvoltages at SVL.

  • PDF

Modeling and Switching Overvoltage Analysis for Reclosing Analysis in Combined Transmission Systems (혼합송전계통에서 재폐로 해석을 위한 모델수립 및 개폐과전압해석)

  • Lim, Kwang-Sik;Lee, Jong-Beom;Kang, Ji-Won;Jung, Chae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.442-443
    • /
    • 2008
  • This paper describes modeling using the EMTP/ATPDraw for reclosing analysis in 154kV combined transmission systems, and analyzes switching overvoltage. Current transformer established at lead-in area and lead-out area in transmission line and circuit breaker were modeled using TACS in the EMTP/ATPDraw. And also MODELS was constructed by signal processing of the operating reclosing. The simulation was carried out the switching overvoltage according to the length of overhead and underground transmission line, overvoltage between sheath and earth, and voltage between joint boxes.

  • PDF

Analysis and Estimation of the Transient Thermal Characteristics of OF Cable systems (OF 케이블 계통 과도상태 열특성 해석 및 평가)

  • Kang, Ji-Won;Lee, Dong-Il;Jung, Chae-Kyun;Lee, Jong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.10
    • /
    • pp.487-495
    • /
    • 2005
  • This paper reviews the characteristic of thermal and temperature of oil field cable in transient state such as grounding fault and lightning surge. For analysis in various conditions, many actual underground power cable systems are modeled using ATP. These results are applied for the examination of temperature increase when the single line to ground fault by the breakdown of insulation part and hitting of lightning surge are occurred. The inner part temperature of OF cable is analysed according to the various kinds of cable using the thermal model of transient state. The temperature increase of sheath and crossbonded lead bv fault current is also analysed using IEC 60949.