• Title/Summary/Keyword: sheath

Search Result 1,232, Processing Time 0.037 seconds

Distribution of positive cells by two monoclonal antibodies (MT1, MB2) in rat spleens (Rat 비장에서 MT1 과 MB2 항체의 양성반응세포 분포)

  • Kwak, Soo-dong;Koh, Phil-ok;Kim, Chong-sup
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.455-460
    • /
    • 1998
  • This study was designed to investigate the distributions of the positive cells in rat spleens by two monoclonal antibodies of MT1 and MB2. The spleens of immature 10 rats (Sprague Duwely, approximately 200gm) were collected and paraffin-embedded sections of spleens were stained with immunohistochemical methods. Higher proportions of MT1-positive cell number in spleens were ordered as marginal zone(8.5~18.1%), red pulp(2.1~8.8%) and periarterial lymphoid sheath(0~1.6%) in white pulp, and those of MB2-positive cell number are ordered as the central area of the periarterial lymphoid sheath(100%), red pulp(29.1~45.0%), marginal zone(15.2~30.4%), and peripheral area of periarterial lymphoid sheath(2.3~3.5%). The positive cells by MB2 are more numerous in number than by MT1. The above results were concluded that the positive cells by above two monoclonal antibodies were scattered throughout the red pulp and marginal zone, but in the central area of the periarterial lymphoid sheath, the MB2-positive cells only were present.

  • PDF

The Effect of Capsaicin on the Peripheral Nerve Damage of Intervibrissal Fur in Rats (Capsaicin을 투여한 성숙 흰쥐의 Intervibrissal Fur 부위의 말초 신경 손상에 관하여)

  • Hong, Hae-Sook;Na, Yeon-Kyung
    • Journal of Korean Biological Nursing Science
    • /
    • v.8 no.1
    • /
    • pp.39-48
    • /
    • 2006
  • Purpose: To see the effects of capsaicin on the peripheral nerve damage of intervibrissal fur in mature rats, Method: 24 female mature rats($200{\sim}250g$) are divided to 3 groups and compared with each other. Immunofluorescence dye using CGRP and PGP antibodies was performed and 8 weeks after administration of capsaicin with control group. Result: The immunopositive reaction against PGP and CGRP was reduced by the damage of epidermal and dermal endings in unmyelinated sheath and thin myelinated sheath and the group after 8weeks showed distinct positive reaction of PGP and CGRP than the group after 4 weeks which means the recover of nerves. Conclusion: As a result, capsaicin influenced on pain-related neurotransmitter like CGRP when administerd to mature rats and even though it caused the damages on unmyelinated sheath and thin myelinated sheath, the damaged nerves recovered after 8 weeks. Also the research about sensory nerve endings scattered over middle dermal and deep epidermal layers such as lanceolate, merkel reticular, Ruffini endings should be studied when the research of the inner conical body is performed. Further studies are necessary about the toxicity and effect of capsaicin on the peripheral nerve endings.

  • PDF

A Case of Malignant Peripheral Nerve Sheath Tumor with Hypopharyngeal Cancer (하인두암과 동반된 경부의 악성 말초 신경초종 1예)

  • Lim, Sang-Ho;Lee, Kyung-Seok;Yang, Yoon-Soo;Hong, Ki-Hwan
    • Korean Journal of Head & Neck Oncology
    • /
    • v.28 no.1
    • /
    • pp.37-41
    • /
    • 2012
  • The malignant peripheral nerve sheath tumor(MPNST) is an extremely rare soft tissue sarcoma of ectomesenchyme also known as malignant schwannoma or malignant neurilemoma. It is a highly malignant sarcoma, which is locally invasive, frequently leading to multiple recurrences and eventual metastatic spread. The peak incidence of this disease is known to arise in the seventh decades. In human body, trunk and extremities are the most commonly involved sites, and only 8-14% of all lesions appear in head and neck region. Because immunohistochemical staining is essential in final diagnosis. The authors report a case of malignant peripheral nerve sheath tumor in neck with hypopharyngeal cancer simultaneously on a review of the literature.

Research on Preparation of Sheath-Core Bicomponent Composite Ion Exchange Fibers and Absorption Properties to Metal Ion

  • Ding, Zhi-Jia;Qi, Lu;Ye, Jian-Zhong
    • Macromolecular Research
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2008
  • Based on the sheath-core bicomponent composite fibers with modified polystyrene (PS) and the modified polypropylene (PP), composite fibers obtained were further cross-linked and sulphonated with chlorosulphonic acid to produce strong acidic cation ion exchange fibers. The structures of the fibers obtained were characterized using Fourier transform infrared (FT-IR) spectroscopy, differential scanning calorimetry (DSC) etc. The optimal technology of the fibers obtained is discussed. The static absorption capacity of the sheath-core bicomponent composite cation exchange fibers for $Zn^{2+}$, $Cu^{2+}$ was determined. The absorption kinetics and major factors affecting the absorption capacities of $Zn^{2+}$, $Cu^{2+}$ were studied, and its chemical stability and regenerating properties were probed. The results suggest that cation exchange fibers with better mechanical properties and higher exchange capability were obtained. Moreover, this type of ion exchange fiber has good absorption properties and working stability to various metal ions. Hence, they have higher practicability.

A Study on the Laser Welding of Cladding Tube with Temp. Sensor for Fuel Irradiation Test (핵연료 조사시험용 온도센서 피복재의 레이저용접 연구)

  • Kim, Su-Seong;Lee, Cheol-Yong;Kim, Ung-Gi;Lee, Jeong-Won;Go, Jin-Hyeon;Lee, Yeong-Ho
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.106-108
    • /
    • 2005
  • The instrumented fuel irradiation test at a research reactor is needed to evaluate the performance of the developed nuclear fuel. The fuel elements can be designed to measure the center line temperature of fuel pellets during the irradiation test by using temperature sensor. The thermal sensor was composed of thermocouple and sensor sheath. Micro-laser welding technology was adopted to seal between seal tube and sensor sheath with thickness of 0.15 mm. The soundness of welding area has to be confirmed to prevent fission gas of the fuel from leaking out of the element during the fuel irradiation test. In this study, fundamental data for micro-laser welding technology was proposed to seal temperature sensor sheath of the instrumented fuel element. And, micro-laser welding for dissimilar metals between sensor sheath and seal tube was characterized by investigating welding conditions. Moreover, the micro-laser welding technology is closely related to advanced industry. It is expected that the laser material processing technology will be adopted to various a pplications in the industry.

  • PDF

Malignant Peripheral Nerve Sheath Tumor in Frontal Sinus, Orbital Cavity and Ethmoid Cavity

  • Lee, Jeong Hwan;Kim, Nam Gyun;Lee, Kyung Suk;Kim, Jun Sik
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.3
    • /
    • pp.125-128
    • /
    • 2014
  • Malignant peripheral nerve sheath tumors are extremely rare soft tissue sarcomas. Among various locations, the trunk and extremities are the most commonly involved sites, with only 15% of such lesions occuring in head and neck region. Here, we report a case of a 74-year-old male who presented with forehead swelling and right eye deviation. Computed tomography images revealed a tumor involving the frontal sinus, ethmoid sinus, and the orbital cavity. The patient underwent a surgical excision of the lesion, which histopathological examination revealed to be a malignant peripheral nerve sheath tumor.

A Study on the Sequence Impedance Modeling of Underground Transmission Systems (지중송전선로의 대칭분 임피던스 모델링에 관한 연구)

  • Hwang, Young-Rok;Kim, Kyung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.60-67
    • /
    • 2014
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. The majority of fault in transmission lines is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and ground wires in overhead transmission systems and through cable sheaths and earth in underground transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, EMTP-based sequence impedance calculation method was described and applied to 345kV cable transmission systems. Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.

The Study of the Fire Possibility of Sheath Heater without Safety Device in Use(Focused on the fire cases) (안전장치 없는 시즈히터에 대한 사용중 발화 가능성 연구(화재사례를 중심으로))

  • Mun, Yong-Su;Myeong, Jeong-Ho;Choe, Jin-Man;Kim, Yong-Su
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.4 no.1
    • /
    • pp.62-69
    • /
    • 2004
  • The purpose of this study on the sheath heater having high occurrence of fires in a small work place because of not having the safety device, was to find out the characteristics required in the field examination of the fires in the courses of investigation. The results of the experiments conducted and reviewed on the basis of the fire cases whose conditions of the ignition possibility were divided into A, E, C and D are as follows: When the sheath heater without safety device is left on the condition of the heat accumulation of which the temperature rapidly rise, and then ignite the inflammables of the surroundings. In such cases, it was characterized that the color change trace appeared even if no short trace was discovered in the power line.

  • PDF

Linearity Analysis and Calibration of a Cable-Conduit Bend Sensor (케이블 컨듀잇 굽힘 센서의 선형 특성 분석 및 켈리브레이션)

  • Jeong, Useok;Cho, Kyu-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.12 no.1
    • /
    • pp.26-32
    • /
    • 2017
  • Previous shape sensors including bend sensors and optic fiber based sensors are widely used in various applications including goniometer and surgical robots. But theses sensors have large nonlinearity, limited in the range of sensing curvature, and sometimes are expensive. This study suggests a new concept of bend sensor using cable-conduit which consists of the outer sheath and the inner wire. The outer sheath is made of helical coil whose length of the central line changes as the sheath bends. This length change of the central line can be measured with the length change of the inner cable. The modeling and the experimental results show that the output signal of the proposed sensor is linearly related with the bend angle of the sheath with root mean square error of 5.3% of $450^{\circ}$ sensing range. Also the polynomial calibration of the sensor can decrease the root mean square error to 2.1% of the full sensing range.

PCM/Nylon6 복합사 염착특성

  • Lee, Jun-Hee;Kim, Hyung-Joo;Yim, Sang-Hyun;Im, Jung-Nam;Son, Young-A
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.11a
    • /
    • pp.35-35
    • /
    • 2011
  • Phase change material(PCM) has thermal energy storage and been attracted attention. Latent heat of the organic PCM can keep maintaining temperature when the change of outside energy conditions influence to PCM. Thus, many researchers have interested to thermal energy storage ability and investigated to applications such as thermal storage of solar energy, bioclimatic building, icebank, medical application, clothing industry and so on. Among the many applications, investigation of the PCM in clothing industry is also important because the people has interest functional factor called health-care in the clothing. In addition, PCM can give them mild environment condition such suitable temperature control or humidity. To fabrics, the PCM has various methods such as microcapsule, padding and modified cross-section formation(Sheath/core). Sheath core PCM fabric has a better benefit of durability than other method. However, PCM sheath/core spinning is difficult. In addition, dyeing property is important to use clothing industry due to visual images. In this study, we investigated dyeing properties of Nylon/PCM sheath/core fabrics. Especially, we observed the relation between dyeing property and PCM including ratio. Various temperature and pH conditions were also studied to optimize dyeing properties as acid dye.

  • PDF