• 제목/요약/키워드: shear zone

검색결과 614건 처리시간 0.028초

개선된 직접전단시험을 이용한 전단영역의 거동 (Behavior of Shear Zone by Improved Direct Shear Test)

  • 변용훈;쭝꽝훙;짠밍콰;이종섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.607-614
    • /
    • 2010
  • Shear behavior of granular soils largely affects the safety and stability of underground and earth structures. This study presents the characteristics of shear zone in a direct shear test using shear wave and electrical resistivity measurements. An innovative direct shear box made of transparent acrylic material has been developed to prevent direct electric current. Bender elements and electrical resistivity probe are embedded in the wall of direct shear box to estimate the shear wave velocities and the electrical resistivity at the shear and non-shear zones. Experimental results show that the void ratio and shear wave velocity at shear zone increase during shearing while the values remain constant at non-shear zone. The results demonstrate correlation among the contact force, small strain shear modulus, and void ratio at shear zone. This study suggests that the application of the modified direct shear box including shear wave and electrical resistivity measurements may become an effective tool for analyzing soil behavior at shear zone.

  • PDF

DIP 기법을 이용한 조립토의 전단영역 크기 분석 (The Thickness of Shear Zone in Granular Materials Using Digital Image Processing)

  • 민덕기;김치영
    • 한국지반공학회논문집
    • /
    • 제22권8호
    • /
    • pp.89-97
    • /
    • 2006
  • 본 논문은 DIP(digital image processing)기법을 이용하여 조립토의 직접전단실험시 발생하는 전단영역의 크기에 대해 상대밀도와 전단하중이 미치는 영향에 대해 분석하였다. 전단변형 후 DIP기법을 적용하여 전단영역의 측정을 위해 적절한 고화제(epoxy resin)를 선택하여 4단계의 초기 상대밀도를 가진 시편이 준비되었고, 각각의 시료에 대해 전단시험 및 고화제 주입, 시편제작, 이미지 분석 등의 단계를 거쳐 전단영역의 크기가 측정하였다. 전단영역의 크기 측정 결과, 시료의 초기 삿대밀도가 증가할수록 전단영역의 크기도 증가하고, 전단하중 재하 중 전단영역 내부의 간극비는 변하지만 전단영역의 크기는 변하지 않는 것을 확인할 수 있었다. 또한, 시편의 초기 상대밀도가 한계상태 이전에는 상대밀도에 따라 전단영역의 크기가 거의 변하지 않으나 한계상태를 지나 조밀한 상태가 된 경우 상대밀도가 증가함에 따라 전단영역의 크기가 크게 증가하는 것으로 나타났다.

호남 전단대의 잠재적 변위 지시자: 가야 지역 회장암체 (A potential displacement marker of the Honam Shear Zone: Gaya anorthosite)

  • 권성택;사공희
    • 암석학회지
    • /
    • 제12권4호
    • /
    • pp.207-209
    • /
    • 2003
  • 현생이언 동안 한반도에서 일어난 중요한 지질 현상 중의 하나인 호남 전단대는 그 지구조적 중요성 때문에 많은 주목을 받아 왔으나, 전단운동의 규모를 나타내는 변위량에 대해서는 거의 알려진 바가 없다. 이 소고에서 우리는 그 변위량을 추정하게 해 줄 수 있는 지시자의 존재를 제안한다. 한반도 남중부의 산청 및 가야 회장암체의 지리적 위치와 특징적인 암상은 북동 방향으로 약 50km 변위를 가진 우수향 주향이동 전단대를 시사한다. 이 가상의 전단대는 그 방향과 전단 감각이 같기 때문에 호남 전단대의 일부로 생각된다.

영광(靈光) 부근(附近) 연성전단대(延性剪斷帶)(전주전단대(全州剪斷帶))의 성질(性質)과 교차양상(交叉樣相)에 관(關)하여 (On the Properties and Intersection Feature of the Ductile Shear Zone (Chonju shear zone) near Yongkwang-Eub)

  • 전경석;장태우;이병주
    • 자원환경지질
    • /
    • 제24권4호
    • /
    • pp.435-446
    • /
    • 1991
  • Ductile shear zones developed in Jurassic granites in the Yonggwang area show NE trend at the eastern part and nearly EW trend at the western part, respectively. Judged from shear sense indicators, they have resulted from dextral strike-slip movement. The intersection of both trends is thought to be due to the truncation and offset of NE shear zone Chonju Shear zone by the brittle Yonggwang fault which runs in near EW direction with sinistral movement sense. The simple shear deformation was predominate through the deformation in this ductile shear zone. Based on this deformation mechanism, the shear strain (${\gamma}$) estimated in domain 1 increases from 0.14 at the shear zone margin to 9.41 toward the center of shear zone. Total displacement obtained only from this measured section(JK 59 to JK14) appecars to be 1434.5 meters. The sequential development of microstructures can be divided into three stages; weakly-foliated, well-foliated and banded-foliated stages. In the weakly-foliated stage dislocation glide mechanism might be predominant. In the well-foliated stage grain boundary migration and progressive misorientation of subgrains was remarkable during dynamic recovery and recrystallization. In the banded-foliated stage grain boundary sliding and microfracturing mechanisms accompanied with crushing and cracking were marked. According to strain analysis from quartzites of the metasedimentary rocks, strain intensity (${\gamma}$) of the samples within the ductile shear zone ranges from 2.7 to 5.7, while that of the samples out of the ductile shear zone appears to be about 1.7.

  • PDF

단부 횡보강영역에 따른 전단벽 연성도의 변화 (Variations in Ductility of Shear Wall with Length of Boundary Confinement)

  • 강수민;오재은;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.853-858
    • /
    • 2001
  • Experimental studies were peformed to investigate variations in ductility of shear wall with length of boundary confinement. Eight specimens containg different lengths of confinment zone, which model compressive zone in plastic regions of shear walls, were tested against eccentric vetical load. Stress-strain model for confined concrete was used to predict strength and ductility of the specimens, which was compared to the test results. The results obtained show that failure of the compressive zone occurs in a brittle manner when the stress of unconfined zone softened after the ultimate strength were reached. To enhance the ductility of shear walls with concentrated confinement zone such as barbell-type walls, the ultimate strength of the confinement zone needs to be increased, and for shear walls with distributed confinement zone the length of the confinement zone needs to be extended.

  • PDF

전단파, 전자기파 및 콘 관입저항력을 이용한 직접전단실험시 전단영역 특성 평가 (Evaluation of Shear Zone in Direct Shear Test Using Elastic, Electromagnetic Waves and Cone Tip Resistance)

  • 변용훈;쭝꽝훙;짠밍콰;이종섭
    • 한국지반공학회논문집
    • /
    • 제27권2호
    • /
    • pp.43-52
    • /
    • 2011
  • 조립토로 구성된 지반구조물의 안정성은 전단변형에 따른 전단영역의 특성변화에 의해 영향을받는다. 본 연구의 목적은 전단파와 전기비저항 및 콘 선단저항력을 이용하여 직접전단실험시 발생하는 전단영역의 특성을 파악하는 것이다. 전단영역의 특성을 파악하기 위하여, 아크릴 재질로 직접전단상자를 제작하였으며, 직접전단상자의 벽면에는 전단파와 전기비저항의 측정을 위하여 벤더엘리먼트와 전기비저항 프로브를 설치하였다. 벤더엘리먼트와 전기비저항 프로브는 전단영역과 비전단영역에 각각 설치되어, 전단변형에 따른 조립토의 거동을 비교할 수 있도록 하였다. 또한, 콘 선단저항력을 측정할 수 있도록 개발한 마이크로 콘을 첨두강도상태와 잔류강도상태에서 관입하여 깊이에 따른 시료의 강도분포를 관찰하였다. 실험결과, 바닥부근과 하부전단영역에서는 전단변형에 따른 전단파 속도는 일정하였지만, 상부전단영역에서의 전단파 속도는 증가하였다. 또한, 바닥부근의 전기비저항은 변화가 없는 반면, 하부전단영역에서 전기비저항은 상대밀도에 따라 수직변형률과 반비례관계로 나타났다. 콘 선단저항력의 변화도 전단파 속도의 변화와 유사하게 상부전단영역에서 큰 변화가 관찰되었다. 본 논문에서 제시한 직접전단실험시 전단파와 전기비저항을 관찰하는 것과 실험완료 후 콘 관입실험은 조립토의 전단영역 특성을 파악하기 위한 매우 효과적인 방법이 될 수 있음을 보여준다.

내진철골모멘트접합부 패널존의 전단좌굴 방지를 위한 패널존 상대강도 (Relative Panel Zone Strength in Seismic Steel Moment Connections for Prevention of Panel Zone Shear Buckling)

  • 김소연;이철호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.845-850
    • /
    • 2007
  • The empirical AISC panel zone thickness provision$(t_z\geq(d_z+w_z)$/90) to prevent the cyclic shear buckling of the panel zone was proposed based on the test data of Krawinkler et al. (1971) and Bertero et al. (1973) However, no published records of the equation development or any other background information appear to be available. The calibrated finite element analysis results of this study indicated that the AISC provision was not reasonable. In this study, through including the effects of the column axial force and the aspect ratio of the panel zone, a new equation for the relative strength between the beam and the panel zone was proposed such that the proposed equation can prevent the panel zone shear buckling and reduce the potential fracture associated with the kinking of the column flanges.

  • PDF

물성치 변동성에 의한 불확실성이 고려된 국내 필댐 사력부를 위한 전단파 속도 주상도 모델 (Determination of Shear Wave Velocity Profile Model Considering Uncertainty Caused by Spatial Variation of Material Property in Rockfill Zone of Fill Dam)

  • 박형춘
    • 한국지반공학회논문집
    • /
    • 제35권2호
    • /
    • pp.29-36
    • /
    • 2019
  • 본 연구에서는 필댐 사력부 전단파 속도 주상도 결정시 물성치 변동성에 의해 발생 가능한 불확실성을 평가하고, 평가된 불확실성이 반영된 국내 필댐 사력부를 위한 전단파 속도 주상도 모델을 제안하였다. 이를 위하여 평가된 불확실성을 바탕으로 국내 필댐 사력부에 존재 가능한 깊이-전단파 속도 곡선 400개를 결정하고, 이에 대한 통계분석을 통하여 깊이별 전단파 속도 상한과 하한 곡선을 결정하였다. 결정된 곡선을 바탕으로 Burger 모델 형태의 깊이별 전단파 속도 상한과 하한 주상도 모델을 결정하였다. 결정된 모델은 국내에서 많이 사용되고 있는 Sawada-Takahashi 모델과 비교하였다.

인장-전단하중을 받는 점 용접재의 변형률 분포 특성 평가 (Evaluation on the Properties of Strain Distribution of the sopt welding specimen under tensile-shear load)

  • 김덕중
    • 한국생산제조학회지
    • /
    • 제8권6호
    • /
    • pp.113-118
    • /
    • 1999
  • In order to evaluate strength of spot welded joint, at first it is importent that we should know strain distribution near nugget zone. During loading, in HAZ, compressive strain increase with Increase of load, but in nugget zone tensile strain increase. During unloading, on the other hand, even through the decreases, the strain variation is not almost appeared in nugget zone and HAZ. In nugget boundary zone, the strain range increases continuously along with load increase on outer surface, but the strain increases continunously and decreases rapidly beyond yield strength on inner surface. In this paper, strain distribution are measured in inner and outer surface with variation of thickness and load under tensile-shear load. Tensile-shear strength increased as with increase of specimen thickness. As for thickness increase rates are 25%, 50%, 100%, and 150%, tensile-shear strength in crease rates are 40%, 81%, 130% and 228%.

  • PDF

Box단면 접합부의 Panel Zone 거동특성 (Panel Zone Behavior of Steel Box Connections)

  • 황원섭
    • 한국강구조학회 논문집
    • /
    • 제9권4호통권33호
    • /
    • pp.683-695
    • /
    • 1997
  • 본 연구는 강제 라멘교각 접합부 panel zone의 전단거동특성에 대하여 검토한 것이다. 여기에서는 접합부 시험체 20개에 대한 재하실험 결과와 3가지의 FEM해석 모델에 대한 결과를 제시 하였다. 이와같은 실험및 해석결과를 비교 검토한 결과, panel zone의 강도와 변형 성능은 단면적비와 전단좌굴등에 의하여 감소하는 경향을 보이고 있음을 알 수 있었다. 따라서 본 연구에서는 이상의 결과를 기초로 panel zone의 강도와 변형성능에 대한 새로운 평가식을 제안하였으며, 또한 기존의 라멘교각 접합부에 대한 변형성능에 관해서 검토하였다.

  • PDF