• 제목/요약/키워드: shear strength characteristic

검색결과 187건 처리시간 0.028초

Perforated shear connectors

  • Machacek, Josef;Studnicka, Jiri
    • Steel and Composite Structures
    • /
    • 제2권1호
    • /
    • pp.51-66
    • /
    • 2002
  • Perforated shear connectors currently used in composite steel and concrete structures are described and evaluated. Modifications of the perforated connector suitable for common use injavascript:confirm_mark('abe', '1'); civil and bridge engineering are proposed. The connectors were tested in laboratories of CTU Prague for shear load capacity. Push tests of connectors with 32 mm openings and with 60 mm openings, both in normal and lightweight concrete of different strength characteristics and with different transverse reinforcement, were carried out. The experimental study also dealt with the connector height and parallel arrangement of two connectors and their influence on shear resistance. While extensive tests with static loading were carried out, fatigue tests under repeated loading are still in progress. After statistical evaluation of the experimental results and comparisons with other available data the authors developed reasonable shear resistance formulas for all proposed arrangements.

경량 성토재 활용을 위한 석탄 저회 물성 비교 (Comparison of Geotechnical Characteristics of Bottom Ash for Lightweight Fill Material)

  • 김윤기;이성진;신민호;이승래;이용식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.679-686
    • /
    • 2010
  • Mechanical characteristics of bottom ash produced in coal-fired power plant are investigated to utilize as light-weight fill materials. Triaxial compression test, water retention test, and unsaturated direct shear test were conducted for weathered soil (WS), reclaimed bottom ash (RBA), and screened bottom ash (BA). RBA had larger frictional angle and lower effective cohesion than those of WS. Water retention charactersitics of RBA and BA existed within distributions of soil-water characteristic curves for domestic weathered soils. Unsaturated shear strength of RBA was similar to that of WS at matric suctions of 50 kPa and 100 kPa. As a conclusion, bottom ash can be used as fill materials to replace the conventional construction materials by.

  • PDF

반복하중을 받는 ├형 철근콘크리트 접합부의 전단특성에 관한 연구 (A Study on the Shear Characteristic of├ Type Reinforced Concrete Joints under Cyclic Loading)

  • 이상호;이동화
    • 한국지진공학회논문집
    • /
    • 제5권2호
    • /
    • pp.73-82
    • /
    • 2001
  • 본 연구는 실험적 방법과 해석적 방법을 통하여 반복하중을 받는 ├형 철근콘크리트 접합부의 전단특성을 파악함을 목적으로 한다. ├형 접합부는 고강도 재료의 사용으로 인한 체적의 감소 뿐만 아니라, 지진발생 시 반복하중의 작용으로 인한 변동축력 등으로 , 구조적으로 취약한 부분이 될 가능성이 있다. 따라서 본 연구에서는 ├형 접합부의 전단특성을 파악하기 위하여 기동축력, 콘크리트 압축강도, 접합부 전단보강근비를 변수로 한 12개의 실험체를 제작하여 가력실험을 수행하였다. 또한, 유한요소 해석을 수행하여 본 실험결과와의 비교 검토를 통하여 타당성을 검토한 후, 기둥축력과 콘크리트 압축강도의 변화에 대한 변수해석을 통하여 접합부의 전단강도에 미치는 변수는 영향을 파악하였으며, 실험에 의한 실험체의 전단내력을 기존에 제안된 AIJ, ACI 규준 등과 비교 검토하였다. 본 연구의 결로부터 기둥축력과 콘크리트 압축강도가 ├형 철근콘크리트 접합부의 전단강도에 미치는 영향을 확인하였다.

  • PDF

모관흡수력에 따른 화강풍화토의 유효응력과 전단강도의 관계 (The Relationship Between Effective Stress and Shear Strength of Weathered Granite Soils Based on Matric Suctions)

  • 이영휘;오세붕;김광현;성열호
    • 한국지반환경공학회 논문집
    • /
    • 제13권4호
    • /
    • pp.45-51
    • /
    • 2012
  • 불포화토를 대상으로 $K_0$ 압밀조건에서 삼축시험을 수행하여 전단강도를 분석하였다. 불포화 삼축압축시험에서는 대구지역에 있는 풍화토 시료를 성형하여 다양한 모관흡수력을 조절하였다. 건조 및 습윤 시 함수특성시험을 수행하여 실험치들을 van Genuchten 곡선으로 모델하였다. 함수특성곡선으로부터 모관흡수력이 유효응력에 기여하는 성분을 평가할 수 있다. 이로부터 유효응력을 산정하였으며 유효응력에 따른 전단강도를 결정하였다. 다양한 모관흡수력에 따른 전단강도는 유효응력으로 기술하였을 때, 유일한 직선으로 나타나며 포화토의 파괴포락선과 일치함을 알 수 있었다.

ECAP Al 2024 합금의 소성변형량에 따른 강도 특성 및 이방성 연구 (A Study on Strength Characteristic Variation as amount of Plastic Deformation and Strength Anisotrophy for ECAP Al 2024 Alloy)

  • 최정우;마영화;윤기봉
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.283-286
    • /
    • 2005
  • When subjected to severe shear deformation by ECAP, microstructure of Al2024 becomes nanocrystalline grained texture material. To measure the strength of that, small punch (SP) testing method was adopted as a substitute for the conventional uniaxial tensile testing because the size of material processed by ECAP were limited to $\varphi12mm$ in transverse direction. SP tests were performed with specimens in longitudinal and transverse directions of Al 2024 ECAP metal. For comparing the strength values with those assessed by SP tests, uniaxial tensile tests were also conducted with specimens in longitudinal direction. Failure surfaces of the tested SP specimens showed that failure mode was shear deformation and Al 2024 ECAP metal has an anisotropy in strength. Thus, conventional equations proposed for assessing the strength characteristics were improper to assess those of Al2024 ECAP metal. In this paper a way of assessing the strength of Al 2024 ECAP metal was proposed and was proven to be effective.

  • PDF

반복-횡력을 받는 조적벽 골조와 전단벽 골조의 내력 및 연성에 관한 실험적 연구 (Experimental Study of Strength and Ductility on Masonry Wall Frame and Shear Wall Frame Subjected to Cyclic Lateral Loading)

  • 이호;변상민;정환목;이택운
    • 한국공간구조학회논문집
    • /
    • 제13권2호
    • /
    • pp.83-91
    • /
    • 2013
  • The core aim of this dissertation is to empirically scrutinize a strength characteristic of beam-column frame subjected to the cyclic lateral load, a beam-column frame of un-reinforced masonry wall, and a shear wall frame. First and foremost, I embark upon making three prototypes vis-$\grave{a}$-vis this research. By conducting this process, I touch on an analysis of cyclic behavior and a damage characteristic of the beam-column frame, the beam-column frame of un-reinforced masonry wall, and the shear wall frame. What is more, through the previous procedure, the next part delves into the exact stress transfer path and the destructive mechanism to examine how much and how strong the beam-column frame of un-reinforced Masonry Wall does have a resistance capacity against earthquake in all the architecture constructed by the above-mentioned frame, as well as school buildings. In addition to the three prototypes, two more experimental models, a beam-column frame and shear wall frame, are used to compare with the beam-column frame of un-reinforced masonry wall. Lastly, the dissertation will suggest some solutions to improve the resistance capacity against earthquake regarding all constructions built with non bearing wall following having examining precisely all the analysis with regard to not only behavior properties and the damage mechanism of the beam-column frame and the beam-column frame of un-reinforced Masonry Wall but also the resistance capacity against earthquake of non bearing wall and school buildings.

Plate로 전면보강된 교량 상판의 거동특성에 관한 연구 (A Study on the Structural Characteristic of Strengthened Bridge Deck Specimens Using External Bonded Plate)

  • 심종성;오홍섭;김언경
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.163-168
    • /
    • 2001
  • Punching shear in concrete slabs is a serious problem in certain structural systems, such as flat slab. In this study, mechanical improvement between specimens which are unstrengthened and strengthened with steel plate and fiber panel is experimentally investigated. The strengthened bridge deck specimens had increment of strength and broke down with punching shear failure. Strengthening ratio should be considered to restraint punching failure.

  • PDF

도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구 (The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal)

  • 김희진;김부섭
    • 대한치과기공학회지
    • /
    • 제32권3호
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

고강도 전단철근을 사용한 철근콘크리트 전단벽체-기초계면에서의 전단마찰 거동특성에 대한 해석적 연구 (Analytical Study on Behavior Characteristic of Shear Friction on Reinforced Concrete Shear Wall-Foundation Interface using High-Strength Reinforcing Bar)

  • 천주현;이기호;백장운;박홍근;신현목
    • 콘크리트학회논문집
    • /
    • 제28권4호
    • /
    • pp.473-480
    • /
    • 2016
  • 본 연구에서는 550 MPa급 고강도 철근을 사용한 낮은 형상비를 갖는 철근콘크리트 전단벽체의 벽체-기초 접합부에서의 전단마찰 파괴거동을 평가하기 위한 해석적 방안을 마련하는 것을 목표로 한다. 형상비, 경계면에서의 마찰계수, 배근상세, 각 방향으로의 철근비, 재료물성 등의 다양한 변수를 갖는 총 16개의 실험체를 검증 대상으로 선정하여 저자 등에 의해 개발된 비선형 유한요소해석 프로그램(RCAHEST)에 콘크리트 구조설계기준(2012)과 CEB-FIP Model code 2010을 바탕으로 경계면에서 수정된 전단마찰 구성관계식을 적용하여 해석을 수행하였다. 최대 하중에 대한 실험과 해석으로부터의 결과는 평균과 변동계수가 각각 1.04와 17% 정도로 예측하였고 일부 실험체를 제외하고 파괴모드와 파괴시까지의 전반적인 거동 특성을 적절히 평가하였다. 결과를 종합해 볼 때, 수정된 전단마찰 구성관계식을 적용한 해석프로그램은 해석 결과에 비교적 높은 신뢰도를 확보하고 있는 것으로 판단된다.

불포화된 화강풍화토에 대한 공학적 특성분석을 위한 실험적 연구 (An Experimental Study on the Engineering Characteristics Analysis of Unsaturated Weathered Granite Soil)

  • 김준석
    • 한국재난정보학회 논문집
    • /
    • 제16권3호
    • /
    • pp.577-585
    • /
    • 2020
  • 연구목적: 불포화토에서 발생하는 모관흡수력의 존재는 사면의 안정성을 증가시키지만, 강우침투 로 인한 모관흡수력의 감소는 갑작스런 사면 파괴를 유발하여 큰 재난을 발생시킬 수 있다. 본 논문에서는 우리나라의 대표적인 산흙인 화강풍화토에 대하여 불포화상태에서의 공학적 특성을 분석하였다. 연구방법:화강풍화토에 대하여 입도상태가 양호한 경우와 입도상태가 불량한 경우로 나누어 불포화 상태에서 함수특성곡선, 불포화투수곡선, 모관흡수력에 대한 불포화 전단강도 관계 등으로서 실험과 분석을 수행하였다. 연구결과: 입도분포가 불량한 경우가 입도분포가 균등한 경우에 비하여 체적함수비에 대한 모관흡수력의 변화가 급격히 발생하는 것으로 분석되었다. 입도가 균등한 경우가 입도가 불량한 경우에 비하여 동일한 모관흡수력에서 투수계수가 비교적 작은 값을 나타내었다. 모관흡수력이 크게 작용할수록 전단강도가 증가하는 경항을 보였다. 결론: 우리나라의 대표적인 산흙인 화강풍화토에 대하여 입도상태가 양호한 경우와 입도상태가 불량한 경우로 나누어 불포화상태에서의 공학적 특성인 함수특성곡선, 불포화투수계수, 불포화 전단강도 등에 대하여 실험을 실시하여 각각의 상관관계를 확보하였다.