• 제목/요약/키워드: shaping methods

검색결과 209건 처리시간 0.023초

Endovascular Treatment of Aneurysms Arising from the Proximal Segment of the Anterior Cerebral Artery

  • Ko, Jun Kyeung;Cha, Seung Heon;Lee, Tae Hong;Choi, Chang Hwa;Lee, Sang Weon;Lee, Jae Il
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권2호
    • /
    • pp.75-80
    • /
    • 2013
  • Objective : Aneurysms arising from the proximal segment of the anterior cerebral artery (A1) are rare and challenging to treat. The aim of this study was to report our experience with endovascular treatment of A1 Aneurysms. Methods : From August 2007 through May 2012, eleven A1 aneurysms in eleven patients were treated endovascularly. Six aneurysms were unruptured and 5 were ruptured. One patient with an unruptured A1 aneurysm presented with subarachnoid hemorrhage due to rupture of an anterior communicating artery aneurysm. Procedural data, clinical and angiographic results were reviewed retrospectively. Results : All of the aneurysms were successfully treated with coil embolization. Six were treated with a simple technique while the remaining 5 required adjunctive technique : double catheters (n=2), balloon-assisted (n=2), and stent-assisted (n=1). The immediate angiographic control showed a complete occlusion in all cases. Procedure-related complication occurred in only one patient : parent artery occlusion, which was not clinically significant. All patients had excellent clinical outcomes but one patient was discharged with a slight disability. No neurologic deterioration or bleeding was seen during the follow-up period in this cohort of patients. Follow-up angiography (mean, 20 months) was available in ten patients and revealed stable occlusion in all cases. Conclusion : Endovascular treatment is a feasible and effective therapeutic modality for A1 aneurysms. Tailored microcatheter shaping and/or adjunctive techniques are necessary for successful aneurysm embolization because of the projection and location of A1 aneurysms.

Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals

  • Ha, Jung-Hong;Park, Sang-Shin
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.215-219
    • /
    • 2012
  • Objectives: The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods: Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer) were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer), #15 NiTi K-file NITIFLEX (Dentsply Maillefer), modified #16 Path File (equivalent to #18), and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer) at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results: Group 4 showed lowest screw-in effect ($2.796{\pm}0.134$) among the groups (p < 0.05). Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions: The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals

  • Park, Hyun-Jin;Seo, Min-Seock;Moon, Young-Mi
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.3.1-3.10
    • /
    • 2018
  • Objectives: The aim of this study was to compare root canal volume change and canal transportation by Vortex Blue (VB; Dentsply Tulsa Dental Specialties), ProTaper Next (PTN; Dentsply Maillefer), and ProTaper Universal (PTU; Dentsply Maillefer) nickel-titanium rotary files in curved root canals. Materials and Methods: Thirty canals with $20^{\circ}-45^{\circ}$ of curvature from extracted human molars were used. Root canal instrumentation was performed with VB, PTN, and PTU files up to #30.06, X3, and F3, respectively. Changes in root canal volume before and after the instrumentation, and the amount and direction of canal transportation at 1, 3, and 5 mm from the root apex were measured by using micro-computed tomography. Data of canal volume change were statistically analyzed using one-way analysis of variance and Tukey test, while data of amount and direction of transportation were analyzed using Kruskal-Wallis and Mann-Whitney U test. Results: There were no significant differences among 3 groups in terms of canal volume change (p > 0.05). For the amount of transportation, PTN showed significantly less transportation than PTU at 3 mm level (p = 0.005). VB files showed no significant difference in canal transportation at all 3 levels with either PTN or PTU files. Also, VB files showed unique inward transportation tendency in the apical area. Conclusions: Other than PTN produced less amount of transportation than PTU at 3 mm level, all 3 file systems showed similar level of canal volume change and transportation, and VB file system could prepare the curved canals without significant shaping errors.

파형정형된 IFDMA 신호에서 클리핑이 스펙트럼과 BER에 미치는 영향 (The Effect of Clipping on the Spectrum and BER of IFDMA Signal with Pulse Shaping)

  • 박승용;김정구
    • 한국통신학회논문지
    • /
    • 제34권11C호
    • /
    • pp.1106-1112
    • /
    • 2009
  • SC-FDMA(single carrier-frequency division multiple access)는 낮은 첨두전력을 가져 최근 3GPP LTE(3rd Generation Partnership Project Long Term Evolution)의 상향 다중 접속방식으로 채택되었다. 파형정형 여파기인 제곱근 상승여현 여파기의 롤오프 계수가 1에서 0으로 감소함에 따라 SC-FDMA의 부반송파 매핑방식 중 하나인 IFDMA(interleaved FDMA) 방식의 대역폭은 좁아지지만, 오히려 그 첨두전력은 심각하게 증가할 수 있다. 실제 시스템에서는 증폭기의 전력효율을 높이기 위하여 높은 첨두전력을 특정 값 이하로 절사하는 클리핑 과정을 수행하게 된다. 신호의 클리핑은 고주파 성분의 재생성 및 신호의 왜곡을 야기할 수 있다. 본 논문에서는 파형정형된 IFDMA 신호에서 클리핑이 스펙트럼과 오율에 미치는 영향을 분석한다.

왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교 (Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation)

  • 전영주;김진우;조경모;박세희;장훈상
    • 대한치과의사협회지
    • /
    • 제52권12호
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.

압출성형 횟수가 떡국떡의 품질 특성에 미치는 영향 (Effects of Extrusion Frequency on the Quality Characteristics of Ddukgukdduk)

  • 배정숙;유창희;이경은
    • 한국식품조리과학회지
    • /
    • 제32권4호
    • /
    • pp.449-457
    • /
    • 2016
  • Purpose: The study was conducted to analyze the change in quality characteristics of Ddukguk Garaedduk and Ddukgukdduk by the frequency of extruding rice dough. Methods: Ddukguk Garaedduk samples were made by extruding and shaping rice flour dough 2, 3, and 4 times; while Ddukgukdduk samples were made by drying the Ddukguk Garaedduk at room temperature for 48 hours and slicing them in slices of 0.3 cm thickness. Results: Significant differences were not found in water content by the extrusion frequency for Ddukguk Garaedduk and Ddukgukdduk. The adhesiveness and springiness of Ddukguk Garaedduk with a 4 times extrusion were significantly higher than those of Ddukguk Garaedduk with a 2 times extrusion. Ddukgukdduk with a 4 times extrusion generated finer cells and a more even distribution of cells than the other samples, as observed by scanning electron microscopy. Upon boiling, significantly more water was absorbed in Ddukgukdduk of a 2 times extrusion than in that of a 4 times extrusion. Hardness and adhesiveness scores of the cooked Ddukgukdduk were the highest, and springiness was the lowest in the sample with the 4 times extrusion. Conclusion: The extrusion of rice dough makes the structure of Ddukguk Garaedduk finer and more even, which results in the increased adhesiveness of Ddukguk Garaedduk. When cooking Ddukguk, Ddukgukdduk that has been extruded more absorbs less water and dissolves less solids, which maintains the chewiness and structure of cooked Ddukgukdduk.

Screw-in forces during instrumentation by various file systems

  • Ha, Jung-Hong;Kwak, Sang Won;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.304-309
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Materials and Methods: Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS-k, DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Results: Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest (p < 0.05). Conclusions: Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended.

A Study on the Performance of Causal Links between Error Causes: Application to Railroad Accident Cases

  • Kim, Dong San;Yoon, Wan Chul
    • 대한인간공학회지
    • /
    • 제32권6호
    • /
    • pp.535-540
    • /
    • 2013
  • Objective: The aim of this study is to evaluate the effectiveness and efficiency of causal links between various error causes in human error analysis. Background: As finding root causes of human error in safety-critical systems is often a cognitively demanding and time-consuming task, it is particularly necessary to develop a method for improving both the quality and efficiency of the task. Although a few methods such as CREAM have suggested causal linking between error causes as a means to enhance the quality and efficiency of human error analysis, no published research to date has evaluated the performance of the causal links. Method: The performance of the CREAM links between error causes were evaluated with 80 railway accident investigation reports from the UK. From each report, errorneous actions of operators were derived, and for each error, candidate causes were found by following the predefined links. Two measures, coverage and selectivity, were used to evaluate the effectiveness and efficiency of the links, respectively. Results: On average, 96% of error causes actually included in the accident reports were found by following the causal links, and among the total of 121 possible error causes, the number of error causes to be examined further was reduced to one-tenth on average. As an additional result of this work, frequent error causes and frequently used links are provided. Conclusion: This result implies that the predefined causal links between error causes can significantly reduce the time and effort required to find the multiple levels of error causes and their causal relations without losing the quality of the results. Application: The CREAM links can be applied to human error analysis in any industry with minor modifications.

Direct metal laser sintering 방식을 이용하여 제작한 다양한 고정성 보철물 수복 증례 (Fixed prostheses fabricated by direct metal laser sintering system: case report)

  • 백주원;신수연
    • 구강회복응용과학지
    • /
    • 제32권3호
    • /
    • pp.246-254
    • /
    • 2016
  • Direct metal laser sintering (DMLS) 방식은 3D 프린팅 중 한 방식으로, 재료를 쌓아가면서 레이저를 이용하여 선택적으로 sintering하는 방식이다. 이는 주조 방식에서 문제되는 결손과 뒤틀림을 방지할 수 있으며 절삭 가공 방식으로 제작하기 어려운 복잡한 구조물을 제작할 수 있다. 본 증례들은 DMLS 방식을 이용하여 지대치 간 길이가 긴 고정성 보철물, 포스트 등 다양한 고정성 보철물을 제작하여 수복하였고, 주기적인 관찰 결과 심미적, 기능적으로 만족할만한 결과를 얻었기에 이를 보고하는 바이다.

PLLA/HA Composite Scaffold와 골수 줄기세포를 이용한 조직공학적 골재생에 대한 연구 (BONE TISSUE ENGINEERING USING PLLA/HA COMPOSITE SCAFFOLD AND BONE MARROW MESENCHYMAL STEM CELL)

  • 김병렬;장현석;임재석;이의석;김동현
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권4호
    • /
    • pp.323-332
    • /
    • 2008
  • Aim of the study: Scaffolds are crucial to tissue engineering/regeneration. Biodegradable polymer/ceramic composite scaffolds can overcome the limitations of conventional ceramic bone substitutes such as brittleness and difficulty in shaping. In this study, poly(L-lactide)/hydroxyapatite(PLLA/HA) composite scaffolds were fabricated for in vivo bone tissue engineering. Material & methods: In this study, PLLA/HA composite microspheres were prepared by double emulsion-solvent evaporation method, and were evaluated in vivo bone tissue engineering. Bone marrow mesenchymal stem cell from rat iliac crest was differentiated to osteoblast by adding osteogenic medium, and was mixed with PLLA/HA composite scaffold in fibrin gel and was injected immediately into rat cranial bone critical size defect(CSD:8mm in diameter). At 1. 2, 4, 8 weeks after implantation, histological analysis by H-E staining, histomorphometric analysis and radiolographic analysis were done. Results: BMP-2 loaded PLLA/HA composite scaffolds in fibrin gel delivered with osteoblasts differentiated from bone marrow mesenchymal stem cells showed rapid and much more bone regeneration in rat cranial bone defects than control group. Conclusion: This results suggest the feasibility and usefulness of this type of scaffold in bone tissue engineering.