• Title/Summary/Keyword: shape comparison

Search Result 1,727, Processing Time 0.031 seconds

Comparison of pants pattern by adolescent boy's body type using 3D virtual simulation

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.2
    • /
    • pp.75-84
    • /
    • 2019
  • The purpose of this study was to present a good pants pattern for boys aged 13-18 by comparing and analyzing the pants pattern according to lower body shape. And through it, this study was to provide basic data for pants production considering male student body shape. The pattern of this study used the industrial type Lee Hee-chun pattern and DC Suite Program for 3D virtual simulation. As a result of the appearance evaluation, there was a significant difference between the patterns in most items. Type 2 was rated highly, followed by Type 4, Type 3, and Type 1. Type 1 required correction of the length of the pants and the amount of crotch part, while type 3 required adjustment of the pants in the knee area. Type 4 required correction of pattern drawing method of crotch width, thigh circumference, and knee circumference. This pattern method was evaluated as suitable for slender body shape. This study suggests a pants pattern system suitable for adolescent boys by reflecting the body shape characteristics of adolescent boy with a change of body shape. It is expected that this will meet the increasing demand for fitting. In this study, we have examined 3D virtual simulation, not actual wear experiment, so it will be necessary to investigate the difference through actual clothing experiment for adolescent boys.

Numerical simulation of the influence of interaction between Qanat and tunnel on the ground settlement

  • Sarfarazi, Vahab;Tabaroei, Abdollah
    • Geomechanics and Engineering
    • /
    • v.23 no.5
    • /
    • pp.455-466
    • /
    • 2020
  • This paper presents analysis of the interaction between tunnel and Qanat with a particular interest for the optimization of Qanat shape using the discrete element code, PFC2D, and the results will be compared with the FEM results of PLAXIS2D. For these concerns, using software PFC2D based on Discrete Element Method (DEM), a model with dimension of 100m 100 m was prepared. A circular tunnel with dimension of 9 m was situated 20 m below the ground surface. Also one Qanat was situated perpendicularly above the tunnel roof. Distance between Qanat center and ground surface was 8 m. Five different shapes for Qanat were selected i.e., square, semi-circular, vertical ellipse, circular and horizontal ellipse. Confining pressure of 5 MPa was applied to the model. The vertical displacement of balls situated in ground surface was picked up to measure the ground subsidence. Also two measuring circles were situated at the tunnel roof and at the Qanat roof to check the vertical displacements. The properties of the alluvial soil of Tehran city are: γdry=19 (KN/㎥), E= 750 (kg/㎠), ν=0.35, c=0.3(kg/㎠), φ=34°. In order to validate the DEM results, a comparison between the numerical results (obtained in this study) and analytical and field monitoring have been done. The PFC2D results are compared with the FEM results. The results shows that when Qanat has rectangular shape, the tensile stress concentration at the Qanat corners has maximum value while it has minimum value for vertical ellipse shape. The ground subsidence for Qanat rectangular shape has maximum value while it has minimum value for ellipse shape of Qanat. The vertical displacements at the tunnel roof for Qanat rectangular shape has maximum value while it has minimum value for ellipse shape of Qanat. Historical shape of Qante approved the finding of this research.

Analysis of Mulberry Leaves Yields and Amount of Silkworms raising in the Mulberry Tree-shape of Vinyl-house (오디용 뽕나무 시설재배 수형별 뽕잎생산량과 누에 사육량 분석)

  • Kim, Dong-Wan;Moon, Hyung-Cheol;Kim, Eun-Ji;Kim, Jeong-Man
    • Korean Journal of Organic Agriculture
    • /
    • v.23 no.4
    • /
    • pp.757-766
    • /
    • 2015
  • This study was considered chances of additional income, if farmers raised silkworms in unused mulberry leaves, after harvesting mulberry, investigated yields of mulberry leaves in vinyl-house and optimal amount in raised silkworms, First, the results was investigated productions of mulberry leaves in the mulberry tree-shape of vinyl-house, T-shape harvested 7.07 kg, Y-shape was 6.55 kg, in comparison with convention of it was harvested 4.75 kg mulberry leaves/1 mulberry tree, was harvested 49%, 38% more each. Also, yields of mulberry leaves was used 302 kg when was raised 1box of silkworms in the mulberry tree-shape of vinyl-house. In other hand, yields of raising silkworms was analysed in the mulberry tree-shapes of vinyl-house, mulberry leaves of $1,000m^2$ vinyl-house mulberry tree was raised average of 3.74 boxs silkworms, in the concrete conventional-shape was 3.24 boxs, T-shape did 4.17 boxs and Y-shape was 3.83 boxs, Consequently, if the farmers of $1,000m^2$ vinyl-house mulberry tree raised silkworms with unused mulberry leaves, could get 1~1.2 million won additionally.

Blank Design of SPFH 590 Steel Sheet for Stamping of Center Hinge of Automotive via Analysis of Transfer Forming Process with Multi-Stages (다단 이송 성형 공정 해석을 통한 자동차 센터 힌지 성형용 SPFH 590 고강도 강판 블랭크 설계)

  • Ahn, Dong-Gyu;Song, Dong-Han;Sohn, Sang-Sik;Han, Gil-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.5
    • /
    • pp.75-84
    • /
    • 2010
  • The aim of this paper is to design the blank shape of SPFH 590 high strength steel for stamping of the center hinge of automotive via numerical analyses and experiments for multi-stages transfer forming process. Three-dimensional elasto-plastic finite element analyses for the transfer forming process with six stages were performed using a commercial code AUTOFORM V4.2. The influence of the blank shape on the formability and the shape conformity were quantitatively examined through the FE analyses. From the results of the FE analysis, a feasible shape of the blank and the forming load were estimated. Stamping experiments were carried out using the proposed blank shape. The results of experiments were shown that the center hinge parts with the desired shapes can be manufactured successfully as the proposed blank shape is used. Through the comparison of the results of the experiments with those of the analyses, it was shown that the estimation of blank shape using the FE analysis is a proper methodology to create a feasible shape of the blank for the center hinge of automotive.

Shape similarity measure for M:N areal object pairs using the Zernike moment descriptor (저니키 모멘트 서술자를 이용한 M:N 면 객체 쌍의 형상 유사도 측정)

  • Huh, Yong;Yu, Ki-Yun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.2
    • /
    • pp.153-162
    • /
    • 2012
  • In this paper, we propose a new shape similarity measure for M:N polygon pairs regardless of different object cardinalities in the pairs. The proposed method compares the projections of two shape functions onto Zernike polynomial basis functions, where the shape functions were obtained from each overall region of objects, thus not being affected by the cardinalities of object pairs. Moments with low-order basis functions describe global shape properties and those with high-order basis functions describe local shape properties. Therefore several moments up to a certain order where the original shapes were similarly reconstructed can efficiently describe the shape properties thus be used for shape comparison. The proposed method was applied for the building objects in the New address digital map and a car navigation map of Seoul area. Comparing to an overlapping ratio method, the proposed method's similarity is more robust to object cardinality.

Influence of Earthquake Shape on the Dynamic Behavior of Fluid in a Rectangular Structure (사각형 구조물에 저장된 유체의 동적거동에 미치는 시간-가속도 형상의 영향)

  • Park, Gun;Hong, Ki-Nam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.59-66
    • /
    • 2017
  • In the case of fluid storage structure, hydrostatic pressure acts on the structure due to fluid surge during an earthquake. At this time, hydrodynamic pressure of the fluid charge not only by the strength of the earthquake but also by the sloshing height of the fluid. Factors affecting the change of load include the size, width and height of the fluid storage structure and height of fluid, time-history shape, etc. This paper wanted to identify the relationship between the earthquake shape and fluid free surface shape. The sloshing height measured the height of the fluid by applying earthquake to a tank whose width 500mm and comparison of the experiment and analysis. In addition, the shape of the fluid free surface was measured while varying the shape of earthquake and effective of the shape of earthquake of the fluid was analyzed.

A Study on Base Isolation Performance and Phenomenological Model of E-Shape Steel Hysteretic Damper (E-Shape 강재이력댐퍼의 수치모델과 기초격리구조물의 지진응답)

  • Hwang, Inho;Ju, Minkwan;Sim, Jongsung;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.685-690
    • /
    • 2008
  • Recently, as large structures become lighter and more flexible, the necessity of structural control for reducing excessive displacement and acceleration due to seismic excitation is increased. As a means to minimize seismic damages, various base isolation systems are adopted or considered for adoption. In this study, a base isolation system using hysteretic damper is shown to effectively protect structures against earthquakes. A mechanical model is determined that can effectively portray the behavior of a typical E-shape device. Comparison with experimental results for a hysteretic damper indicates that the model is accurate over a wide range of operating conditions and adequate for analysis. The seismic performance of hysteretic dampers are studied and compared with the conventional systems as a base isolation system. A five-story building is modeled and the seismic performance of the systems subjected to three different earthquake is compared. The results show that the hysteretic damper system can provide superior protection than the other systems for a wide range of ground motions.

A Research regarding the Figuration Comparison of 3D Printing using the Radiation DICOM Images (방사선 DICOM 영상을 이용한 3차원 프린팅 출력물의 형상 비교에 관한 연구)

  • Kim, Hyeong-Gyun;Choi, Jun-Gu;Kim, Gha-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.558-565
    • /
    • 2016
  • Recent 3D printing technology has been grafting onto various medical practices. In light of this trend, this research is intended to examine the figuration surface's accuracy of 3D images made by using DICOM images after printing by 3D printing. The medical images were obtained from animal bone objects, while the objects were printed after undergoing STL file conversion for 3D printing purposes. Ultimately, after the 3D figuration, which was obtained by the original animal bones and 3D printing, was scanned by 3D scanner, 3D modeling was merged each other and the differences were compared. The result analysis was conducted by visual figuration comparison, color comparison of modeling's scale value, and numerical figuration comparison. The shape surface was not visually distinguished; the numerical figuration comparison was made from the values measured from the four different points on the X, Y and Z coordinates. The shape surface of the merged modeling was smaller than the original object (the animal bone) by average of -0.49 mm in the 3D printed figuration. However, not all of the shape surface was uniformly reduced in size and the differences was within range of -0.83 mm on the experiment.

Study on Diagnosis by Facial Shapes and Signs as a Disease-Prediction Data for a Construction of the Ante-disease Pattern Diagno-Therapeutic System - Focusing on Gallbladder's versus Bladder's Body and Masculine versus Feminine Shape - (미병학(未病學) 체계구축을 위한 질병예측자(疾病豫側子)로서의 형상진단연구 - 담방광체(膽膀胱體)와 남녀형상(男女形象)을 중심으로 -)

  • Kim, Jong-Wan;Kim, Kyung-Chul;Lee, Yang-Tae;Lee, In-Seon;Kim, Kyu-Kon;Chi, Gyoo-Yang
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.540-547
    • /
    • 2009
  • There needs disease-predictable signs in order to enable preventive diagnosis and therapy. Then traditional Chinese medicine applies various medical diagnostic equipments used in western medicine to diagnosing sub-healthy state. But such data are not originated from inherent oriental medicine, and not obtained easily in ordinary clinical practice. This paper is to provide synopsis of the ante-disease diagno-therapeutics partly and to show predictable data based on the facial shapes and signs, especially of gall bladder's versus bladder's body and masculine versus feminine shape. Ante-disease means not only the complete healthy state, but also the state unseen any symptoms in macrographically in the course of outbreak of disease. It contains two stages, first one is the former state of disease and second one is untransmitted state of disease. The patterns of ante-disease consist of latent disease, pre-disease, transmission type like senescent syndrome, abnormal reactive syndrome(變證), syndrome of transmission and transmutation. The classification with gall bladder and bladder type manifests the differences of shape, color and size of each organ in comparison of the universal and standard figures of the human being. On the other hand, the classification with masculine and feminine shape contrasts the innate sexual difference and the shape, characteristics originated from in itself. These two classification theories have their own pathologic types and syndrome types with each disease so that disease-predictable data can be constructed based on such a relationship. In addition, this diagnostic method by facial shapes and signs is able to be applied to whole stages from prenatal to present state of disease even if the cause and inducement are not clear. Ante-disease diagno-theraputic system by Gall Bladder's versus Bladder's Body and Masculine versus Feminine Shape is getting more important in the chronic and internal disease in comparison of the acute and traumatic disease. So this study is able to make up for the limit of diagnosis on ante-disease in the field of oriental medicine clinic.

A Comparative Analysis of the Difference between 3D Body Scan Measurements and Physical Measurements by Gender -5th Size Korea Adult Data- (3차원 스캔측정치와 직접치수간 차이의 성별 비교 -제5차 Size Korea 성인데이터를 대상으로-)

  • Han, Hyun-Sook;Nam, Yun-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.8
    • /
    • pp.1190-1202
    • /
    • 2009
  • A 3D body scan measurement (SM) is used as an alternative to physical measurements (PM) as the information for designing industrial products. This study compared the mean difference (MD) between SM and PM by gender and analyzed the causes of the difference. The data used in this study were the scan measurements and physical measurements of adults aged twenty to seventy years old of the fifth Size Korea survey. The results of this study are as follows: 1. The comparison of MD between men and women for all subjects: The measurement of the significant differences between men and women were height, neck base girth, chest girth, under-bust girth, waist girth, armscye girth, back length, and foot length. The causes of difference are the difference of body shape. 2. The comparison of MD between men and women by BMI groups: Many measurements had significant differences between men and women at normal weight and overweight but underweight. Some measurements had significant differences only at a specific BMI group because the body shape difference between men and women is revealed clearly in the group. The comparison of MD between men and women by age groups: The measurements that show significant difference at more than four age groups were neck girth, chest girth, under-bust girth, waist girth, armscye girth, and foot length. The height and abdomen girth had a significant difference in the age range of 20's and 30's. There were measurements that increase MD with an increase in age; under-bust girth and lateral shoulder length for women and lateral shoulder length for men. This comparison of MD between men and women provide the correct guidelines for the use of SM.