• Title/Summary/Keyword: shaking test

Search Result 538, Processing Time 0.028 seconds

Seismic Damage Assessment and Nonlinear Structural Identification Using Measured Seismic Responses (실측 지진응답을 이용한 지진손상도 평가 및 소성모형 추정)

  • 이형진;김남식
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.6
    • /
    • pp.7-15
    • /
    • 2002
  • In this paper, the nonlinear parameter estimation method using the estimated hysteresis of each structural members was studied for the purpose of efficient seismic damage prediction and estimation of MDOF nonlinear structural model in the shaking table test. The hysteresis of each structural members can be obtained by the conversion of measured response histories into relative motions of each structural members and member forces. These hysteresis can be used to evaluate various kinds of damage indices of each structural members. The MDOF nonlinear structural model for further analysis(re-analysis) can be easily reconstructed using estimated nonlinear structural parameters of each structural members. To demonstrate the proposed techniques, several numerical and experimental example analyses are carried out. The results indicate that the proposed method can be very useful to assess local seismic damages of structures.

Implementation of a macro model to predict seismic response of RC structural walls

  • Fischinger, Matej;Isakovic, Tatjana;Kante, Peter
    • Computers and Concrete
    • /
    • v.1 no.2
    • /
    • pp.211-226
    • /
    • 2004
  • A relatively simple multiple-vertical-line-element macro model has been incorporated into a standard computer code DRAIN-2D. It was used in blind predictions of seismic response of cantilever RC walls subjected to a series of consequent earthquakes on a shaking table. The model was able to predict predominantly flexural response with relative success. It was able to predict the stiffness and the strength of the pre-cracked specimen and time-history response of the highly nonlinear wall as well as to simulate the shift of the neutral axis and corresponding varying axial force in the cantilever wall. However, failing to identify the rupture of some brittle reinforcement in the third test, the model was not able to predict post-critical, near collapse behaviour during the subsequent response to two stronger earthquakes. The analysed macro model seems to be appropriate for global analyses of complex building structures with RC structural walls subjected to moderate/strong earthquakes. However, it cannot, by definition, be used in refined research analyses monitoring local behaviour in the post critical region.

A new type liquid damper with adjustable natural frequencies (고유진동수 조절이 가능한 새로운 형태의 액체댐퍼)

  • Lee, Hye-Ri;Min, Kyung-Won;Park, Ji-Hun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.161-165
    • /
    • 2011
  • 본 논문에서는 고유진동수 조절이 가능한 새로운 형태의 액체댐퍼를 개발하였다. 동조댐퍼는 구조물의 설계단계에서 응답평가를 통해 필요성이 요구된다. 건물은 설계단계에서 고유진동수와 시공 후 고유진동수가 상이하다. 액체댐퍼의 형태는 설계단계에서 건물의 고유진동수를 동조시킬 수 있도록 설계되기 때문에 고유진동수가 고정이 될 수 있다. 본 연구에서는 제안한 댐퍼의 전체적인 형태는 기존의 Liquid Column Vibration Absorber(LCVA)와 같다. 기존의 LCVA는 시공 후 건물의 고유진동수에 동조시키기 위해 물높이를 조절하나 층고 때문에 제한이 있다. 우리가 제안한 새로운 형태의 액체댐퍼는 물높이 조절 뿐 아니라 수직관의 면적을 조절하여 고유진동수를 조절 할 수 있도록 개발하였다. LCVA의 수직관을 일정한 면적의 독립된 셀로 나누었으며 이 셀을 각각 밀폐시킬 수 있도록 하였다. 밀폐된 셀 안으로는 공기압력에 의해 물이 차지 않고 차 있는 물도 움직이지 않게 된다. 밀폐된 셀의 개수를 조정하여 수직관의 면적이 조절하여 고유진동수를 변화시킬 수 있다. 제작된 액체댐퍼의 밀폐된 셀 개수를 조절하여 진동대 실험을 통해 댐퍼의 고유진동수를 파악하였다. 실험으로 나온 고유진동수와 이론적으로 산정한 고유진동수를 비교하여 댐퍼의 사용성을 평가하였다. 개발된 액체 댐퍼의 수직관의 면적 조절을 통해 고유진동수 조절이 용이하여 실제로 사용이 가능함을 확인할 수 있었다.

  • PDF

An ESED method for investigating seismic behavior of single-layer spherical reticulated shells

  • Zhang, Ming;Zhou, Guangchun;Huang, Yanxia;Zhi, Xudong;Zhang, De-Yi
    • Earthquakes and Structures
    • /
    • v.13 no.5
    • /
    • pp.455-464
    • /
    • 2017
  • This paper develops a new method for analyzing the structural seismic behavior of single-layer reticulated shells based on exponential strain energy density (ESED). The ESED method reveals a characteristic point from a relationship between ESED sum and peak seismic acceleration. Then, the characteristic point leads to an updated concept of structural failure and an ESED-based criterion for predicting structural failure load. Subsequently, the ESED-based criterion and the characteristic point are verified through numerical analysis of typical single-layer reticulated shells with different configurations and a shaking table test of the scale shell model. Finally, discussions further verify the rationality and application of the ESED-based criterion. The ESED method might open a new way of structural analysis and the ESED-based criterion might indicate a prospect for a unified criterion for predicting seismic failure loads of various structures.

Study on the Biological Effects of TSP Collected from the Subway Station with Tradescantia Bioassay (지하철 시설내 부유먼지에 함유된 돌연변이원의 생물학적 영향 평가)

  • Kim, Jin-Kyu;Shin, Hae-Shik;Lee, Jeong-Joo;Kim, Kyun;Lee, Jin-Hong
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.245-252
    • /
    • 2002
  • Airborne pollutants in the subway facilities can be potentially harmful to the health of passengers. This study was designed to examine whether the suspended particulates have mutagenic or carcinogenic effect on the plant cell systems. Total suspended particulates were collected with a high volume air sampler, in the entrance, the waiting room, and the platform of each subway station. The biological end -points in this experiment were the pink mutations in stamen hairs and micronuclei in the pollen mother cells of Tradescantia. The exudates were collected by shaking the filter papers from the sampler in distilled water for 24 hours. All the plant cuttings exposed to the exudates resulted in positive responses. The micronucleus assay proved more reliable and sensitive to the test than the stamen hair assay. The results indicate that the air particulates can give an adverse effect on the health of subway passengers.

Review of the Extraction Methods of Soil Extracts, Soil Elutriates, and Soil Suspensions for Ecotoxicity Assessments (생태독성평가를 위한 Soil Extracts, Soil Elutriates, Soil Suspensions 추출기법)

  • Nam, Sun-Hwa;An, Youn-Joo
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.15-24
    • /
    • 2014
  • Soil pollution has been recognized as a serious problem because it causes groundwater pollution through medium contacts. Although concentration of individual chemical could be more easily measured by physico-chemical analysis, it is not easy to consider the bioavailability of edaphic receptors living in soil or groundwater. To measure the toxicity of soil, the soil extracts (soil elutriates or soil suspensions in the other words) are often used due to the difficulties of extracting soil pore water. In this study, we reviewed 15 toxicity test methods found in literature to analyze the detail of each extraction method and to recommend the most frequently used extraction methods. The identified most commonly used extraction methods are as following: The 1 : 4 soil:water ratio, 24 hours shaking time, room temperature, dark, and separation of supernatant using a $0.45{\mu}m$ pore size filter.

Analysis of Failure Behavior of Pile Embedded in Liquefiable Soil Deposits considering Buckling Instability (좌굴을 고려한 액상화 지반에 근입된 말뚝의 파괴거동 분석)

  • Han, Jin-Tae;Cho, Chong-Suck;Hwang, Jae-Ik;Kim, Myoung-Mo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.105-112
    • /
    • 2006
  • Liquefaction-induced lateral spreading has been the most extensive damage to pile foundations during earthquakes. However, a case of pile failure was reported despite the fact that a large margin of safety factor was employed in their design. This means that the current seismic design method of pile is not agreeable with the actual failure mechanism of pile. Newly proposed failure mechanism of pile is a pile failure based on buckling instability. In this study, failure behavior of pile embedded in liquefied soil deposits was analyzed considering lateral spreading and buckling instability performing 1g shaking table test. As a result, it can be concluded that the pile subjected to excessive axial loads ($near\;P_{cr}$) can fail by buckling instability during liquefaction. When lateral spreading took place in sloping grounds, lateral spreading increased lateral deflection of pile and reduced the buckling load, promoting more rapid collapse. In addition, buckling shape of pile was observed. In the ease of pile buckling, hinge formed at the middle of the pile, not at the bottom. And in sloping grounds, location of hinge got loiter compared with level ground because of the effects of lateral spreading.

  • PDF

Simultaneous detection of five biocides in household products by gas chromatography-mass spectrometry

  • Choi, Kyeong-Yun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.197-204
    • /
    • 2022
  • A gas chromatography-mass spectrometric method was developed for determining 5-chloro-2-methyl-4-isothiazolin-3-one (CMIT), 2-methyl-4-isothiazolin-3-one (MIT), 1,2-benzisothiazolin-3-one (BIT), 3-iodo-2-propynyl butyl carbamic acid (IPBC) and benzoic acid (BA) in household products. A 0.5 g sample was placed in a test tube and dissolved with 5 mL water, 5 mL methylene chloride and 1.0 mL methanol. The solution was extracted by ultra-sonication followed by mechanical shaking using the salting out effect. Under the established condition, the lowest quantification limits of all analytes were in the range of 0.04-10 mg/kg and their relative standard deviations were less than 8.0 %. The method was used to analyze 10 household products. As a result of analyzing 10 household products, MIT was detected in the range of 1.2-3.5 mg/kg in 3 of 10 samples, CMIT was detected in the range of 2.6-8.2 mg/kg in 3 of 10 samples, and BA was detected in the range of 5.0-15 mg/kg in 4 of 10 samples. Meanwhile, BIT and IPBC were not detected in any of the products. It has been shown that this method can be used for the simultaneous determination of biocides with various physical and chemical properties in household products.

Damage evaluation of seismic response of structure through time-frequency analysis technique

  • Chen, Wen-Hui;Hseuh, Wen;Loh, Kenneth J.;Loh, Chin-Hsiung
    • Structural Monitoring and Maintenance
    • /
    • v.9 no.2
    • /
    • pp.107-127
    • /
    • 2022
  • Structural health monitoring (SHM) has been related to damage identification with either operational loads or other environmental loading playing a significant complimentary role in terms of structural safety. In this study, a non-parametric method of time frequency analysis on the measurement is used to address the time-frequency representation for modal parameter estimation and system damage identification of structure. The method employs the wavelet decomposition of dynamic data by using the modified complex Morlet wavelet with variable central frequency (MCMW+VCF). Through detail discussion on the selection of model parameter in wavelet analysis, the method is applied to study the dynamic response of both steel structure and reinforced concrete frame under white noise excitation as well as earthquake excitation from shaking table test. Application of the method to building earthquake response measurement is also examined. It is shown that by using the spectrogram generated from MCMW+VCF method, with suitable selected model parameter, one can clearly identify the time-varying modal frequency of the reinforced concrete structure under earthquake excitation. Discussions on the advantages and disadvantages of the method through field experiments are also presented.

Behaviors of UHPC-filled Q960 high strength steel tubes under low-temperature compression

  • Yan, Jia-Bao;Hu, Shunnian;Luo, Yan-Li;Lin, Xuchuan;Luo, Yun-Biao;Zhang, Lingxin
    • Steel and Composite Structures
    • /
    • v.43 no.2
    • /
    • pp.201-219
    • /
    • 2022
  • This paper firstly proposed high performance composite columns for cold-region infrastructures using ultra-high performance concrete (UHPC) and ultra-high strength steel (UHSS) Q960E. Then, 24 square UHPC-filled UHSS tubes (UHSTCs) at low temperatures of -80, -60, -30, and 30℃ were performed under axial loads. The key influencing parameters on axial compression performance of UHSS were studied, i.e., temperature level and UHSS-tube wall thickness (t). In addition, mechanical properties of Q960E at low temperatures were also studied. Test results revealed low temperatures improved the yield/ultimate strength of Q960E. Axial compression tests on UHSTCs revealed that the dropping environmental temperature increased the compression strength and stiffness, but compromised the ductility of UHSTCs; increasing t significantly increased the strength, stiffness, and ductility of UHSTCs. This study developed numerical and theoretical models to reproduce axial compression performances of UHSTCs at low temperatures. Validations against 24 tests proved that both two methods provided reasonable simulations on axial compression performance of UHSTCs. Finally, simplified theoretical models (STMs) and modified prediction equations in AISC 360, ACI 318, and Eurocode 4 were developed to estimate the axial load capacity of UHSTCs at low temperatures.