• Title/Summary/Keyword: sg-continuous

Search Result 14, Processing Time 0.026 seconds

Design and Fabrication of butt-coupled(BT) sampled grating(SG) distributed bragg reflector(DBR) laser diode(LD) using planar buried heterosture(PBH) (저 전류 및 고 효율로 동작하는 양자 우물 매립형 butt-coupled sampled grating distributed bragg reflector laser diode 설계 및 제작)

  • Oh Su Hwan;Lee Chul-Wook;Kim Ki Soo;Ko Hyunsung;Park Sahnggi;Park Moon-Ho;Lee Ji-Myon
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.469-474
    • /
    • 2004
  • We have fabricated and designed wavelength-tunable sampled grating distributed Bragg reflector laser diodes(SGDBR-LD) by using, for the first time, planar buried heterostructures(PBH). The diodes have low threshold current values and high-performance of laser operation. Growth condition using metal organic chemical vapor deposition(MOCVD) was optimized for the formation of a good butt-coupling at the interface. A maximum output power of the fabricated device was 20 mW under 200 mA continuous wave(CW) operation at $25^{\circ}C$. Average threshold current and voltage were 12 mA and 0.8 V, approximately. This output power is higher than those of ridge waveguide(RWG) and buried ridge stripe(BRS) structures by amounts of 9 mW and 13 mW, respectively. We obtained a tuning range of 44.4nm which is well matched with the target value of our design. The side mode suppression ratio of more than 35 dB was obtained for the whole tuning range. Optical output power variation was less than 5 dB, which is 4 dB smaller than that of RWG structures.

Medical Image Compression Using JPEG International Standard (JPEG 표준안을 이용한 의료 영상 압축)

  • Ahn, Chang-Beom;Han, Sang-Woo;Kim, Il-Yoen
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.504-506
    • /
    • 1993
  • The Joint Photographic Experts Group (JPEG) standard was proposed by the International Standardization Organization (ISO/SC 29/WG 10) and the CCITT SG VIII as an international standard for digital continuous-tone still image compression. The JPEG standard has been widely accepted in electronic imaging, computer graphics, and multi-media applications, however, due to the lossy character of the JPEG compression its application in the field of medical imaging has been limited. In this paper, the JPEG standard was applied to a series of head sections of magnetic resonance (MR) images (256 gray levels, $256{\times}256$ size) and its performance was investigated. For this purpose, DCT-based sequential mode of the JPEG standard was implemented using the CL550 compression chip and progressive and lossless coding was implemented by software without additional hardware. From the experiment, it appears that the compression ratio of about 10 to 20 was obtained for the MR images without noticeable distortion. It is also noted that the error signal between the reconstructed image by the JPEG and the original image was nearly random noise without causing any special-pattern-related artifact. Although the coding efficiency of the progressive and hierarchical coding is identical to that of the sequential coding in compression ratio and SNR, it has useful features In fast search of patient Image from huge image data base and in remote diagnosis through slow public communication channel.

  • PDF

A REVIEW ON THE ODSCC OF STEAM GENERATOR TUBES IN KOREAN NPPS

  • Chung, Hansub;Kim, Hong-Deok;Oh, Seungjin;Boo, Myung Hwan;Na, Kyung-Hwan;Yun, Eunsup;Kang, Yong-Seok;Kim, Wang-Bae;Lee, Jae Gon;Kim, Dong-Jin;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.513-522
    • /
    • 2013
  • The ODSCC detected in the TSP position of Ulchin 3&4 SGs are typical ODSCC of Alloy 600MA tubes. The causative chemical environment is formed by concentration of impurities inside the occluded region formed by the tube surface, egg crate strips, and sludge deposit there. Most cracks are detected at or near the line contacts between the tube surface and the egg crate strips. The region of dense crack population, as defined as between $4^{th}$ and $9^{th}$ TSPs, and near the center of hot leg hemisphere plane, coincided well with the region of preferential sludge deposition as defined by thermal hydraulics calculation using SGAP computer code. The cracks developed homogeneously in a wide range of SGs, so that the number of cracks detected each outage increased very rapidly since the first detection in the $8^{th}$ refueling outage. The root cause assessment focused on investigation of the difference in microstructure and manufacturing residual stress in order to reveal the cause of different susceptibilities to ODSCC among identical six units. The manufacturing residual stress as measured by XRD on OD surface and by split tube method indicated that the high residual stress of Alloy 600MA tube played a critical role in developing ODSCC. The level of residual stress showed substantial variations among the six units depending on details of straightening and OD grinding processes. Youngwang 3&4 tubes are less susceptible to ODSCC than U3 and U4 tubes because semi-continuous coarse chromium carbides are formed along the grain boundary of Y3&4 tubes, while there are finer less continuous chromium carbides in U3 and U4. The different carbide morphology is caused by the difference in cooling rate after mill anneal. There is a possibility that high chromium content in the Y3&4 tubes, still within the allowable range of Alloy 600, has made some contribution to the improved resistance to ODSCC. It is anticipated that ODSCC in Y5&6 SGs will be retarded more considerably than U3 SGs since the manufacturing residual stress in Y5&6 tubes is substantially lower than in U3 tubes, while the microstructure is similar with each other.

A Non-parametric Trend Analysis of Water Quality Using Water Environment Network Data in Nakdong River (낙동강수계 물환경측정망 자료를 이용한 비모수적 수질 경향 비교 및 분석)

  • Kim, Jungmin;Jeong, Hyungi;Kim, Hyeran;Kim, Yongseok;Yang, Deukseok
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.1
    • /
    • pp.61-77
    • /
    • 2020
  • In South Korea, major public waters have been systematic management under national level. Water environment network has been continuous monitoring for change of aquatic ecosystem, river and reservoir. In Water Quality Monitoring Networks, the data have been generally monitored Per eight days or month, while in Automatic Water Quality Monitoring Network the data have been monitored at daily intervals. Therefore, we were compared and analyzed water quality data between the networks using statistic method for same water quality item. Mann-kendall test results confirm that all points in Water Temperature (WT) and DO were not statistically significant. In particular, the result revealed that there is significant variation of TOC in the four different sites, TN in two different sites, TP in three different sites, WT in seven different sites, pH in two different sites between Water Quality Monitoring Network and Automatic Water Quality Monitoring Network. As a result firm LOWESS, TOC and pH clearly shows different trend. Among different sites, the water quality show the significantly positive correlations between at Sinam-Sangju2 and Namgang-Namgang4. Negative correlation significantly appeared in TP (ADD_Lower-AD1 site), TOC (DG-SG site), pH (GR-GR site), TP (JP-CN) and TN, TP, pH, EC, DO (GC-GC2-1 site).