• Title/Summary/Keyword: sewerage

Search Result 251, Processing Time 0.037 seconds

Effect of municipal sludge from drainage facility on foul smell (도시내 배수설비 슬러지가 악취에 미치는 영향 연구)

  • Yu, Dae-Hyun;Park, Jihoon;Lee, Yong-Hoon;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

Characteristics of Bacteria in the Living Room and Bathroom of a Residential Environment Using the Pyrosequencing Method (파이로시퀀싱 분석법을 이용한 주거 환경 중 거실과 화장실의 세균 특성)

  • Lee, Siwon;Chung, Hyen-Mi;Park, Eung-Roh
    • Microbiology and Biotechnology Letters
    • /
    • v.44 no.1
    • /
    • pp.84-88
    • /
    • 2016
  • In this study, bacterial diversity in the living room and bathroom of a residential environment was analyzed using the pyrosequencing method. There was no difference in the diversity index of bacteria between the 2 rooms; however, differences were noted in the composition of bacteria. The classes ${\beta}$-Proteobacteria and ${\delta}$-Proteobacteria were found in the bathroom at higher abundances than in the living room. The phyla Acidobacteria, Chlorobi, Chloroflexi, Fusobacteria, Nitrospirae, and Planctomycetes were found in the bathroom, but not in the living room, indicating a broader range of bacteria. However, the living room showed a more diverse range of bacterial genera than the bathroom did. In both the living room and the bathroom, the genus Methylobacterium was dominant.

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.85-88
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PARs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRT AP) of Europe. A method of the gas chromatographic-mass spectrometric (GC-MS) determination of PARs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PARs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PARs sewage sludge samples varied from 2.44 to 4.82 ${\mu}g$/g. Concentration of emission carcinogen PARs(PARcarc), such as Benzo(a)anthracene, Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(a)pyrene, Dibenzo(a, h)anthracene and Indeno(1, 2, 3-cd)pyrene ranged from 0.62 to 1.03 ${\mu}g$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PARs and $\sum$PAHcarc from sewage treatment plants had several pathway each by-products. In the ocean dumping, PAHs and $\sum$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year. In recycle, PAHs and $\sum$PAHcarc emissions were 98.36 kg/year and 428.87 kg/year. In the landfill, PAHs and $\sum$PAHcarc emissions were 190.40 kg/year and 830.21 kg/year. In the incineration, PAHs and $\sum$PAHcarc emission were 33.10 kg/year and 830.21 kg/year. (In case of incineration, the whole provisions of PARs and $\sum$PAHcarc contained to flowed in sludge was supposed to be exhausted to environment through exhaust after incineration.)

  • PDF

Establishment of Effluent Limitation based on Wastewater Characteristics and Treatment Technology (폐수특성 및 처리기술에 근거한 산업폐수 배출허용기준 설정체계 연구)

  • Kwon, Ohsang;Jung, Jinyoung;Heo, Teayoung;Jun, Hangbae;Lee, Younhee;Park, Sangmin
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.804-812
    • /
    • 2012
  • This study contemplated domestic and other country's effluent limitation standards and suggested a methodology to establish technology-base limitation value. Current effluent limitation regulates industrial point sources discriminated by discharge flow rate and by regional distinction in Korea. Discharged $BOD_5$ load from large-scale plants(flow rate above $2,000\;m^3/day)$ exceeds 50% of overall industrial wastewater, which present rationale for discrimination based on plant size. However, regional distinction and pollutant- specific regulation might be insufficient to meet practical effectiveness of wastewater management policy, due to the nearly same limitation. Water quality data and treatment methods were investigated in hospital industry. And their distribution of effluent $BOD_5$ concentrations was statistically analyzed to suggest limitation value. Effluent $BOD_5$ concentrations showed lognormal distribution and $95^{th}$ percentile was corresponded to 87.9 mg/L, which could be suggested as tentative effluent limitation in hospital industry. The $95^{th}$ percentile of log-transformed distribution showed similar value of 86.5 mg/L. This study demonstrated reasonable methodology for establishing effluent limitation reflecting wastewater characteristic and treatment technology in separately categorized industry.

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • Journal of Environmental Science International
    • /
    • v.12 no.11
    • /
    • pp.1167-1171
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PAHs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRTAP) of Europe. A method of the gas chromatographicmass spectrometric (GCMS) determination of PAHs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PAHs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PAHs sewage sludge samples varied from 2.44 to 4.82 $\mu\textrm{g}$/g. Concentration of emission carcinogen PAHs(PAHcarc), such as Benzo(a)anthracene, Benzo(b)f1uoranthene, Benzo(k)f1uoranthene, Benzo(a)pyrene, Dibenzo(a,h)anthracene and Indeno( 1,2,3-cd)pyrene ranged from 0.62 to 1.03 $\mu\textrm{g}$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PAHs and $\Sigma$PAHcarc from sewage treatment plants had emitted to environment by several pathway. The highest amount of emission to the environment was remarked in the ocean dumping(PAHs and $\Sigma$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year, respectively).