• Title/Summary/Keyword: sewage treatment system

Search Result 369, Processing Time 0.029 seconds

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.3
    • /
    • pp.1-9
    • /
    • 2021
  • Purpose: This study was conducted to develop a module with higher removal efficiency and effectiveness by adapting two or more deodorization techniques for main cause of odor pollution exposed citizen living near water treatment facilities. Research design, data and methodology: To consider the standard, unity, electrical wire, compatibility of detachable device by installing two types of dry deodorization device within one module for easy replacement. Complex odor, H2S, NH3 were collected from sewage treatment facilities for evaluation of deodorization device. Results: Using the developed application in this study, removal efficiency of complex odor, H2S, NH3 were 93%, 100%, 82%, respectively. Conclusions: The H2S removal efficiency of deodorization device was higher than bio-filter system, which were currently used by sewage treatment. Further, the device should be considered for use in efficient odor removal system.

Toxicity characteristics of sewage treatment effluents and potential contribution of micropollutant residuals

  • Kim, Younghee;Farnazo, Danvir Mark
    • Journal of Ecology and Environment
    • /
    • v.41 no.11
    • /
    • pp.318-327
    • /
    • 2017
  • Background: A typical sewage treatment plant is designed for organic and nutrient removal from municipal sewage water and not targeted to eliminate micropollutants such as pesticides, pharmaceuticals, and nano-sized metals which become a big concern for sustainable human and ecological system and are mainly discharged from sewage treatment plant. Therefore, despite contaminant removal by wastewater treatment processes, there are still remaining environmental risks by untreated pollutants in STP (sewage treatment plant) effluents. This study performed aquatic toxicity tests of raw wastewater and treated effluents in two sewage treatment plants to evaluate toxicity reduction by wastewater treatment process and analyze concentration of contaminants to reveal potential toxic factors in STP effluents. Methods: Water samples were collected from each treatment steps of two STPs, and acute and chronic toxicity tests were conducted following USEPA (United States Environmental Protection Agency) and OECD (Organization for Economic Cooperation and Development) guidelines. Endpoints were immobility for mortality and reproduction effect for estrogenicity. Results: Acute $EC_{50}s$ (median effective concentration) of influents for Seungki (SK) and Jungnang (JN) STPs are $54.13{\pm}32.64%$ and $30.38{\pm}24.96%$, respectively, and reduced to $96.49{\pm}7.84%$ and 100%. Acute toxicity reduction was clearly correlated with SS (suspended solids) concentration because of filter feeding characteristics of test organisms. Chronic toxicity tests revealed that lethal effect was reduced and low concentration of influents showed higher number of neonates. However, toxicity reduction was not related to nutrient removal. Fecundity effect positively increased in treated wastewater compared to that in raw wastewater, and no significant differences were observed compared to the control group in JN final effluent implying potential effects of estrogenic compounds in the STP effluents. Conclusions: Conventional wastewater treatment process reduced some organics and nutritional compounds from wastewater, and it results in toxicity reduction in lethal effect and positive reproductive effect but not showing correlation. Unknown estrogenic compounds could be a reason causing the increase of brood size. This study suggests that pharmaceutical residues and nanoparticles in STP effluents are one of the major micropollutants and underline as one of estrogenic effect factors.

A Study on Fuzzy Control Method of Energy Saving for Activated Sludge Process in Sewage Treatment Plant (하수처리 활성오니공정의 에너지 절감을 위한 퍼지 제어 방법에 관한 연구)

  • Nahm, Eui-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1477-1485
    • /
    • 2018
  • There are two major issues for activated sludge process in sewage treatment plant. One is how to make sewage be more clean and the other is the energy saving in sewage treatment process. The major monitoring sewage qualities are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent. These are transmitted to the national TMS(Telemetry Monitoring System) at every hour. If these exceed the environmental standard, the environmental charges imposed. So, these water qualities are to be controlled below the environmental standard in operation of sewage treatment plant. And recently, the energy saving is also important in process operation. Over 50% energy is consumed in blowers and motors for injection oxygen into aeration tank. So, with the water qualities to be controlled below the environmental standard, the energy saving also is to be accomplished for efficient plant management. Almost researches are aimed to control water quality without considering energy saving. AI techniques have been used for control water quality. AI modeling simulator provided the optimal control inputs(blower speed, waste sludge, return sludge) for control water quality. Blower speed is the main control input for activated sludge process. To make sewage be more clean, the excessive blower speed is supplied, but water quality is not better than the previous. In results, non necessary energy is consumed. In this paper we propose a new method that the energy saving also is to be accomplished with the water qualities to be controlled below the environmental standard for efficient plant management. Water qualities in only aeration tank are used the inputs of fuzzy models. Outputs of these models are chemical oxygen demand, phosphorus, nitrogen, suspended solid in effluent and have the environmental standards. In test, we found this method could save 10% energy than the previous methods.

A Study on Treatment Measures of Carcass Disposal Site Leachate into the Livestock Manure and Sewage Treatment Facilities using NIER-MASS program (NIER-MASS 프로그램을 이용한 가축매립지 침출수 연계처리 방안 연구)

  • Jeong, Dong-Hwan;Lee, Chulgu;Shin, Jinsoo;Kim, Hyunwoo;Yoon, Soohyang;Kim, Yongseok;Yu, Soonju;Kim, Shinjo
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.725-734
    • /
    • 2012
  • The outbreak of foot and mouth disease in November 2010 raised many social, economic and environmental issues and water contaminations by leachate from carcass disposal sites particularly emerged as a serious concern. In oder to efficiently handle these problems, a critical method is required to transport leachate to livestock manure and sewage treatment plants and purify it. This study aims to present the best applicable method to transport leachate from carcass disposal sites into livestock manure and sewage treatment facilities. We investigated the biological and chemical characteristics such as BOD, COD, SS, TN, TP and Total coliforms. Current conjugated treatments in livestock manure and sewage treatment plants was studied by surveying the operations of those facilities. The NIER-MASS(National Institute of Environmental Research - Mass Balance Evaluation System of Sewage Treatment Facilities) program was applied to present the best conjugated treatment method through estimating the maximum daily load to meet the water quality standards in effluent.

Effects of Sewage Treatment on Characteristics of Sludge as a Composting Material (하수처리가 퇴비화를 위한 하수 슬러지 특성에 미치는 영향)

  • Kim, Jae-Koo;Kim, Jong-Soo
    • Applied Biological Chemistry
    • /
    • v.41 no.2
    • /
    • pp.181-186
    • /
    • 1998
  • The effects of sewage treatment on characteristics of sludge as a composting material were investigated for a year during the initial operation at the full-scale Chunan sewage treatment plant. Due to the shortage of design capacity of belt press, a sludge dewatering unit, non-volatile solids were recirculating and concentrating in the treatment plant, resulting in an increase of MLSS and a decrease in F/M ratio at the activated sludge system. Special attention is required for long term operations since the increase of non-volatile solids in the plant would deteriorates the treatment efficiency. The sewage sludge of the Chunan sewage treatment plant showed 79.5% of water content, 11.6% of organic content, and C/N ratio of 6.1, and contained As 1.8 mg/kg, Cd 27 mg/kg, Hg <0.1 mg/kg, Pb 54 mg/kg, T-Cr 370 mg/kg, and Cu 1,100mg/kg of heavy metals. In order to be used as raw material for optimum composting, the sewage sludge requires bulking agents for moistrure/porosity control and a carbon source for adjusting C/N ratio. However, the sewage sludge is not adequate as a soil conditioner after composing due to a high content of heavy metals. If the sewage sludge has to he used as a soil conditioner after composting, it as required to identify and remove tire industrial wastewater portions in tire influent of the plant since heavy metals in the influent were mostly concentrated in dewatered sludge.

  • PDF

A study on the Effect of SOB(Sulfur-Oxidizing Bacteria) Media on the Removal of Hydrogen Sulfide in Water of Septic Tank (SOB(Sulfur Oxidizing Bacteria) Media가 정화조의 수중황화수소 제거에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil;Kim, Taeksoo;Kwon, Sucheol;Yu, Hyeongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.59-67
    • /
    • 2013
  • The odor occurring in the sewage system induces the displeasure, the disgust such as the headache, the vomit, etc. and increases the spiritual stress and disturbs the pleasant life of residents. These odors occur mainly in the area of combined sewage system treatment, being created in the personal sewage treatment plant such as septic tank and are incoming to sewage pipes and emitted to the outside through the manhole and the receiver, etc.; and this causes odors to the people. The Hydrogen Sulfide, the Methyl Mercaptan, the Ammonia, etc. are materials causing the odor, the more serious issue of odor is occurring since the septic tank of degradation process is being applied. The primary cause of odor is the decomposition of human feces in the septic tanks and sewage disposal facilities. The purpose of this study is reduction of hydrogen sulfide using air supplying and SOB(Sulfur-Oxidizing Bacteria). As a result of this study of the air supply system and the SOB media equipment by air supply, in case the air is injected to SOB media compared to the injection of air only, the removal efficiency the hydrogen sulfide was average 3.4 times higher.

A study on Determination Method of the Compliance Concentration of Effluent Limitation from Public Sewage Treatment Works in the Jinwee-stream Watershed Sewer System (유역하수도 공공하수처리시설의 방류수 수질 준수농도 설정방안 연구: 진위천 수계를 중심으로)

  • Jeong, Dong-Hwan;Cho, Yangseok;Kim, Youngseok;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.493-502
    • /
    • 2015
  • In accordance with the Watershed Sewer System Maintenance Plan enforced on February 2, 2013, the different compliance concentration of effluent limit be applied to effluent discharged from public sewage treatment works(PSTWs) in each watershed on the basis of water quality thereof. With the introduction of watershed sewer system, it is necessary to set the compliance concentration of effluent limit for PSTWs situated in the watershed, by region and PSTW size, to achieve water quality criteria for regional watersheds or target water quality under TMDL program. Watershed Environmental Agencies establish the Watershed Sewer System Maintenance Plan and set the compliance concentrations of effluent limit for PSTWs under the plan. The agencies plan to apply tougher effluent BOD concentration limits in Class I to IV areas. Effluent BOD concentration limits will be toughened from 5~10 mg/L to 3 mg/L in class II~III areas, from 10mg/L to 5mg/L in class IV areas. Uniform application of effluent BOD concentration limits to PSTWs in the watershed sewer system need to be complemented considering type of sewage treatment technology employed and watershed characteristics. Therefore, this study presents method to determine the compliance concentration of effluent limit from PSTWs in the watershed.

A Study on Removal of Nitrogen at Sewage Treatment using Solar Energy (Solar Energy를 이용한 하수처리의 질소 제거에 관한 연구)

  • Hwang, Yong Ha
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.37-42
    • /
    • 2011
  • The purpose of this research is to improve nitrogen removal efficiency in winter season through rise of water temperature of extraneous water by using solar energy which is estimated to have great potential among new regeneration energy and while operating Plug-Flow Reactor to improve nitrogen removal efficiency by selecting A/O process among sewage waste water treatment processes as the necessity of solving the problem of nitrogen removal efficiency according to reduced water temperature in winter season and strengthening of water quality criteria regarding discharged sewage waste water suggested in the research background. Summarizing the research result, supply of solar energy source improves the function outstandingly when removing nitrogen, (nitrogen removal rate before operating solar energy 55.4% ${\rightarrow}$ nitrogen removal rate after operating solar energy 84.1%).

  • PDF

Enhancement of Sewage Treatment Efficiencies by Recirculation in Absorbent Biofilter System (재순환에 의한 흡수성 바이오필터 시스템의 오수처리효율 향상)

  • Kwun, Soon-Kuk;Cheon, Gi-Seol;Kim, Song-Bae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.3
    • /
    • pp.69-76
    • /
    • 2005
  • An Absorbent Biofilter System (ABS) combined with the recirculation process was investigated for the feasible application in additional removing of organics (BOD, SS) as well as nutrients (TN, TP) from small Community wastewater in Korea. Polyurethane biofilter media with high porosity and large surface area were /used for the aerobic system. A part of treated wastewater was recirculated into the anoxic septic tank to promote removal of nutrients. The concentrations of BOD and SS of treated wastewater satisfied the regulations for small on-site wastewater treatment facility (10 mg/L) during the overall experimental period. The effluent concentrations of BOD and SS were decreased with enhancement of removal efficiencies of 95.7 and $96.7\%$. The nitrogen and phosphorus removal efficiencies by the recirculation increased to $52.9\%\;and\;43.2\%$ in average during the overall experimental period, respectively. With the improvement, these values were increased as much as additional 42 and $18\%$ compared with those of non-recirculation. The rates of nitrification and denitrification were enhanced showing $65\~77\%\;and\;42\~92\%$, respectively. The described process modification is a low cost and effective method of enhancing nitrogen and phosphorus removal, especially on existing systems without changing major design components of a treatment facility.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.