• Title/Summary/Keyword: sewage treatment sludge

Search Result 400, Processing Time 0.026 seconds

Products and pollutants of half dried sewage sludge and waste plastic co-pyrolysis in a pilot-scale continuous reactor (반 건조 하수슬러지와 폐플라스틱 혼합물의 파일롯 규모 연속식 열분해에 의한 생산물과 발생 오염물질)

  • Kim, YongHwa;Chun, Seung-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.327-337
    • /
    • 2017
  • A continuous low temperature ($510^{\circ}C{\sim}530^{\circ}C$) pyrolysis experiment in a pilot-scale of 85.3 kg/hr was carried out by the mixed feedstock of half dried digested sewage sludge and waste plastics. As a result, the amount of pyrolysis gas generated was maximum 68.3% of input dry mass and scored $40.9MJ/Nm^3$ of lower heating value (LHV), and the percentage of air inflow caused by continuous pyrolysis was 19.6%. The oil was produced 4.2% of the input dry mass, and the LHV was 32.5 MJ/kg. The sulfur and chlorine contents, which could cause corrosion of the facility, were found to be 0.2% or more respectively. The carbide generated was 27.5% of the input dry mass which shows LHV of 10.2 MJ/kg, and did not fall under designated waste from the elution test. The concentration of carbon monoxide, sulfur oxides and hydrogen cyanide of emitted flu gas from pyrolysis gas combustion was especially high, and dioxin (PCDDs/DFs) was within the legal standards as $0.034ng-TEQ/Sm^3$. Among the 47 water pollutant contents of waste water generated from dry flue gas condensation, several contents such as total nitrogen, n-H extract and cyanide showed high concentration. Therefore, the merge treatment in the sewage treatment plants after pre-treatment could be considered.

A Study on Optimum Moisture Content and C/N ratio of Sewage Sludge Treatment Using Composting (퇴비화를 이용한 하수슬러지 처리에 있어서 적정 수분함량과 C/N비에 관한 연구)

  • 손현석;양원호;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.2
    • /
    • pp.44-56
    • /
    • 1997
  • When sewage sludge is treated by cornposting, higher moisture content and lower C/N ratio on sewage sludge is problems. This paper project to alesolve two problems. The almost trends in run 3 of MC 70% are similar to these in run 1 and 4 of MC 65%. A retention time of the highest temperature (>50$\circ$C) and increase rate of temperature in run 3 are an affinity to these in run 4. Particularly, decrease rate of temperature in run 3 is slower than others and this data shows the more activity of thermal microbial in run 3 than that in others. C/N ratio trends in run 3 shows slow reaction in initial stage but, after 9 days, is similar to that in run 1 and 4. Carbon trends in each run are a similarity to C/N ratio trends. Temperature, MC, carbon and C/N ratio trends in run 5, whose C/N ratio is 15, show less microbial activity than that in run 6, whose C/N ratio is 20. But temperature increase of the beginning stage and pH of the final stage in run 5 are greater than that in run 6. Final MC and carbon content in run 5 and 6 have a similar values. That is, final MC in run 5 and 6 is 49.39% and 48.97% and final carbon content in each run is 25.15% and 22.20%. Expecially, a temperature increase and C/N ratio decrease rate of the beginning stage in run 5 are greater than these in run 6. This shows the shorter lag time in run 5 than lag time in run 6.

  • PDF

A Feasibility Study for Renewable Energy from Sewage Sludge Biogas (하수슬러지 Biogas의 신재생에너지화 타당성 연구)

  • Kang, Ho;Lee, Hye Mi;Cho, Sang Sun;Park, Sun Uk;Jeong, Ji Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.754-760
    • /
    • 2010
  • This study was carried out not only to evaluate optimal operating condition to increase biogas production, but also to estimate feasibility of renewable energy from anaerobic digester of sewage sludge. Semi- continuous Fed and Mixed Reactors (SCFMRs) were operated in various condition to quantify the reactor variables. The result of SCFMR operation showed that the biogas productivity and total volatile solids (TVS) removal of total solids (TS) 4% reactor at hydraulic retention time (HRT) 20 days with Organic Loading Rate (OLR) of $1.45kg/m^3-d$ were $0.39m^3/m^3-d$ and 26.7%, respectively which was two times higher than that of TS 2.5% reactor. Consequently the daily biogas production of $20,000m^3$ would be possible from the total volume of $52,000m^3$ of anaerobic digesters of the municipal wastewater treatment plant in D city. In feasibility study for the Biogas utilization, combined heat and power system (CHP) and CNG gasification were examined. In case of CHP, the withdrawal period of capital cost for gas-engine (GE) and micro gas-turbine (MGT) were 7.7 years and 9.1 years respectively. biogas utilization as Clean Natural Gas (CNG) shows lower capital cost and higher profit than that of CHP system. CNG gasificaion after biogas purification is likely the best alternative for Biogas utilization which have more economic potential than CHP system. The withdrawal period of capital cost appeared to be 2.3 years.

Isolation and identification of a phenol-degrading bacterium from the sewage sludge (하수슬러지로부터 페놀분해세균의 분리 및 동정에 관한 연구)

  • Kim, Young-Jun;Lee, Suk-Won;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.1
    • /
    • pp.67-74
    • /
    • 2004
  • A bacterium which grow on phenol as an only carbon and energy source was isolated from the sewage sludge at Nangi municipal wastewater treatment plant in Seoul. This bacterium was found to be a Gram negative rod with high motility, and well grew on 0.05%, 0.1%, and 0.15% of phenol. No matching strain was found from the result of the BBL test. Phylogenetic analysis of the strain by comparison of the 16s-rDNA has revealed that this bacterium has 99% of similarity with Stenotrophomonas maltophilia strain of Xanthomonas group, which belongs t the Gamma (${\gamma}$) subdivision of Proteobacteria. This strain has also shown 98% of similarity with nitrogen fixing bacterium MAGDE3 and Pseudomonas cissicola strain, and 97% of similarity with Stenotrophomonas sp. LMG198 and Xanthomonas cucurbitae.

  • PDF

Biosorption of Reactive Dyes using Chemically Modified Sewage Sludge (화학적으로 변형된 하수슬러지를 이용한 반응성염료의 생물흡착)

  • Han, Min-Hee;Choi, Gi-Wook;Yun, Yeoung-Sang
    • Clean Technology
    • /
    • v.13 no.3
    • /
    • pp.215-221
    • /
    • 2007
  • Biosorption is considered to be a promising alternative to replace the present methods for the treatment of dye-containing wastewater. In this study, sewage sludge was used as a biosorbent which could be one of the cheapest and most abundant biomaterials. The objective of this work is to develop a surface-modified biosorbent with enhanced sorption capacity and binding affinity. The FT-IR and potentiometric titration studies revealed that carboxyl, phosphateand amine groups played a role in binding of dye molecules. The binding sites for reactive dye Reactive Red 4 (RR 4) were identified to be amino groups present in the biomass. In this work, based on the biosorption mechanism, the performance of biosorbentcould be enhanced by the removal of inhibitory carboxyl groups from the biomass for practical application of the biosorbents. As a result, the maximum capacity of biomass was increased up to 130% and 210% of the increment of sorption capacity at pH 2 and 4, respectively. Therefore, chemically modified sewage sludge can be used as an effective and low-cost biosorbent for the removal of dyes from industrial discharges.

  • PDF

Development and Performance Evaluation of Electrodewatering System for Sewage Sludge Recycling

  • Lee, Jae-Keun;Lee, Jung-Eun;Shin, Hee-Soo;Park, Chan-Jung;Lee, Chang-Gun;Kim, Young-Hwan;Kim, Man-Jong
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.443-447
    • /
    • 2001
  • A laboratory-scale electrodewatering system for enhancing conventional filter pressure dewatering by an electric field has been developed to decrease the water content of sludge generated in the wastewater treatment. It consists of a piston-typed filter press, a power supply and data acquisition system. The offset of electrodewatering is investigated as a function of applied pressure, applied voltage, sludge type and filtration time. Also the optimal conditions for maximizing the dewatering efficiency in the eletrodewatering system are investigated. Electric field strength and mechanical pressure are in the range of from 0 to 120 V/cm and from 98.1 to 392.4 kPa. The dewatering rates increased with increasing electric strength. These experiments produced a final sludge cake with water content of 60 wt% using electrodewatering technology, compared with a 80 wt% using pressure filtration alone. The conventional filtration system using the electrodewatering shows the potential to be effective method for improving dewatering Sludge.

  • PDF

Effect of Wet Milling on Scum Generation and Solubilization in Batch Ozone Reaction Using Digested Sludge (소화슬러지를 이용한 회분식 오존반응 시 습식분쇄가 스컴 생성과 가용화에 미치는 영향)

  • Hong, Seong-Min;Lee, Dong-Hoon;Kim, Choong-Gon;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.27 no.2
    • /
    • pp.13-18
    • /
    • 2019
  • Sewage sludge treatment is increasing every year due to improvement of living and urbanization. However, interest in anaerobic digestion which is one of the recycling technology. There is anaerobic digestion of increasing due to limitations of ocean dumping and final disposal. But, the limit of anaerobic digestion efficiency due to the advanced treatment of sewage has been limited, and studies for solubilization technology have been actively conducted. Therefore, in this study, we aimed to investigate the variation of generation of scum and the solubilization efficiency in the application of pre-treatment of ozone reaction and the change of properties of digested sludge with wet milling. There are results of VS/TS increased by 4.4% and $SCOD_{cr}/TCOD_{cr}$ increased by 9.4% by wet milling alone. In addition, the increase of the specific surface area due to which the reduction of the particle size of the solid content of the sludge in the ozone reaction caused by wet milling decreased the generation rate of scum at 14.3% and increased VS/TS at 2.1%, compared with the ozone reaction alone. From these results, it is expected that the application of wet milling can be increased the contact efficiency with solids in the sludge during ozone reaction with suppress scum and increase the efficiency of the subsequent process in anaerobic digestion.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

Optimal Management Scheme for Phosphorus Discharged from Public Sewage Treatment Plant Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 공공 하수종말처리시설의 총인 배출 최적관리)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Jeong, Myungsuk;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.200-209
    • /
    • 2011
  • The purpose of the study is to optimally manage sewage treatment plant with analysis of phosphorus contribution and improvement of water quality contributing rate in the effect of inflowing point of effluent and Pal-Dang lake after reducing T-P discharge from large scale public sewage treatment plant at upstream of Pal-Dang lake. Also, this study, for enforcement of T-P in effluent, plans optimal management of effluent T-P through examining propriety of environmental, technological, and economical aspect such as water quality standard of domestic and foreign T-P and related policy. In regarding optimal management of T-P discharged from public sewage treatment plant located in upstream of Pal-Dang lake, the study drew following conclusions. With the optimal management of public sewage treatment plant, it showed that a pollution level became higher in the order of Sumgang E in South-Han river, C in Dalcheon, B1 B2, A in North-Han river, and J in Kyungancheon, and it is required reduction of T-P first. The highest value in analysis of benefit-costs from sewage treatment plant in the selected research area was Kyungan B, and the others are with the order of Jojong A, Bokha A, Kyungan A, and Yanghwa A. With result of this study, all 14 areas are required more enforced phosphorus treatment. The study resulted that the most top priority areas were Hangang F, Sumgang B, and Gyungan A, top priority areas were Bokha A, Dalcheon B, and Cheongmi A, priority areas were Hangang E, Heukcheon A, Gyungan B, and Jojong A, and potential areas were Sumgang A, Yanghwa A, Dalcheon A, and Hangang D. It seems to be appropriate to apply 0.2 mg/L of T-P treatment for water supply source reservation, 0.5 mg/L for the other areas by locally, and 0.2~0.5 mg/L for biological nitrogen phosphorus treatment method and 0.5~1 mg/L for Conventional Activated Sludge by technologically. Also, it may be appropriate to apply 0.2 mg/L for the most top priority area(I), 0.3 mg/L for the top priority area(II), 0.4 mg/L for priority area(III), and 0.5 mg/L for potential area(IV) by the separation of priority area.

Effective correlation between coagulation efficiency and the sludge settling characteristic (슬러지 응집효율이 침강특성에 미치는 상관관계에 대한 연구)

  • Han, Gee-Bong;Yoon, Ji-Hyun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.1
    • /
    • pp.151-159
    • /
    • 2006
  • In these days, the importance of sludge treatment is emerging due to the London Convention, so this study was conducted to propose the alternatives for the improved sludge treatment on the organic wastewater and sewage sludge with JAR test and settling column equipped with stirrer. The minimum coagulant dosage to earn the optimum sludge settling efficiency resulted from 200mg/l and each critical sludge settling interface showed no distinct difference when PAC was dosed over 200mg/l. Accordingly, Clarification Rate(CR) with 200mg/l dosage was calculated to CR=(Ho-Ht) / Ho=1-0.4=0.6 because the critical sludge settling height stopped at 0.4. The settling velocity of sludge interface was decreased with the increase of MLSS concentration but rather increased with MLSS concentration over 1,000mg/l. This resulted from positive effect of interacted coagulation for floc formation by transfer to the zone of compressed settling when MLSS concentration increased over 1,000mg/l. The settling velocity of sludge interface showed $28.66{\times}10^{-3}/min$ for average settling velocity of sewage sludge which is 6.7 times higher than $4.25{\times}10^{-3}/min$ for average settling velocity of organic wastewater sludge. The increasing rate of CR for organic wastewater activated sludge was higher than that of settling velocity under 200mg/l of PAC dosage but settling velocity was higher than CR over 200mg/l of PAC dosage. However, in case of sewage sludge, the differential rate of CR was low when PAC dosage was increased but the settling velocity was suddenly increased with over 200mg/l dosage. Therefore coagulation effect was more efficient to MLSS settling velocity rather than SS removal effect in the supernatant.

  • PDF