• 제목/요약/키워드: sewage treatment plant

검색결과 524건 처리시간 0.031초

하수처리장 변압기 설치사례 연구를 통한 전력손실 저감방안 (Case Studies on the Electric Power Loss Reducing Methodology for Transformer Installation in Sewage Treatment Plant)

  • 김주영;최창규
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.70-77
    • /
    • 2011
  • Sewage treatment plants, consuming 1,756[GWh] which is 0.53[%] of national wide electricity consumption, is one of the electricity consuming facilites. At the research of electricity consumption and power quality analysis on sewage treatment plants, average utilization of transformer was less than 40[%] because peak load was very lower than its capacity due to excess capacity. So reduction of power loss can be achieved by transformer design optimization. The achievement in this research, is to meet reduction of power loss through optimizing the capacity and to improve as high efficiency-low loss transformer while the transformer is operating.

저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향 (The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage)

  • 황규대;김민호;고새봄
    • 상하수도학회지
    • /
    • 제11권1호
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF

간접가온 건조방식의 건조시설을 이용한 하수슬러지 퇴비화에 관한 연구 (Research on composting of sewage sludge using dryer facility with indirect heating system)

  • 백선재;한인섭;최익훈;강성효;홍성민
    • 상하수도학회지
    • /
    • 제28권3호
    • /
    • pp.299-304
    • /
    • 2014
  • The need of reusing sewage sludge is highly increasing as the amount of domestic sewage sludge is growing and sewage management strategies were reinforced. Accordingly, in this research, we studied the composting possibility of sludge in sewage treatment plant J, using dryer facility with indirect system by conducting component analysis of dried sludge and experiment on cultivating crops. It was observed from the component analysis, that the dried sludge is appropriate for both decomposed manure standard of Ministry of Environment and fertilizer standard of Rural Development Administration. Besides, in the experiment on cultivating lettuce, the experimental group(soil + dried sludge) was superior to the control group(soil + bed soil) in apparent condition of leaves tensity and damage by disease and pest. In case of cultivating tomato, the experimental group showed stronger durability of fruits dangling on stems compared to the control group after 9 weeks. Consequently, the excess sludge dried by indirect heating system in the sewage treatment plant J is appropriate for the standard of both Ministry of Environment and Rural Development Administration and show good result in experiment on cultivating crops therefore it can be reused for composting.

활성슬러지공정 하수종말처리장의 분원성 지표세균의 농도 및 비교 (Enumeration and Comparison of Fecal Indicator Bacteria in a Sewage Treatment Plant Using Activated Sludge Process)

  • 이동근;성기문;정미라;박성주
    • 한국환경보건학회지
    • /
    • 제36권2호
    • /
    • pp.141-147
    • /
    • 2010
  • Indicator bacteria of fecal pollution were enumerated and compared by various detection methods for influent and final effluent of a sewage treatment plant. Total coliforms were enumerated by four methods including most probable numbers, chromogenic enzyme substrate test, membrane filtration, and plate counts and were about $10^4$ for influent and $10^2{\sim}10^3\;CFU/ml$ for final effluent. Fecal coliforms ranged between $10^3$ and $10^4$ for influent and $10^2\;CFU/ml$ for effluent by chromogenic enzyme substrate test and membrane filtration. Fecal streptococci counts were 1-log less than fecal coliforms counts, $10^2{\sim}10^3$ for influent and $10^1\;CFU/ml$ for effluent. Total coliforms numbers by plate count both in influent and in effluent showed 1-log higher than by the other three methods. Statistical analysis revealed that numbers of total coliforms by plate count in final effluent had the highest average of correlation (r=0.778, p<0.01) compared with those by the other three methods. In addition, total coliforms numbers by plate count showed most significant correlation (r=0.835, p<0.01) with those by chromogenic test which is well-known as its highest recovery efficiency. These results suggest that the plate count would be the optimum detection method for total coliforms in wastewater treatment plants which are the only microbiological standard of final effluent from wastewater treatment plants in the Republic of Korea, considering economic aspects and difficulties in laboratories.

고전압 전기장을 이용한 하수처리장 방류수 중의 대장균군 소독에 관한 연구 (A Study on the Disinfection of Coliform Group in the Effluent of Sewage Plant by High Voltage Electric Field Treatment)

  • 이민규;정근식;감상규
    • 한국환경과학회지
    • /
    • 제17권7호
    • /
    • pp.817-826
    • /
    • 2008
  • Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH $5{\sim}9$ used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.85-88
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PARs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRT AP) of Europe. A method of the gas chromatographic-mass spectrometric (GC-MS) determination of PARs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PARs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PARs sewage sludge samples varied from 2.44 to 4.82 ${\mu}g$/g. Concentration of emission carcinogen PARs(PARcarc), such as Benzo(a)anthracene, Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(a)pyrene, Dibenzo(a, h)anthracene and Indeno(1, 2, 3-cd)pyrene ranged from 0.62 to 1.03 ${\mu}g$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PARs and $\sum$PAHcarc from sewage treatment plants had several pathway each by-products. In the ocean dumping, PAHs and $\sum$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year. In recycle, PAHs and $\sum$PAHcarc emissions were 98.36 kg/year and 428.87 kg/year. In the landfill, PAHs and $\sum$PAHcarc emissions were 190.40 kg/year and 830.21 kg/year. In the incineration, PAHs and $\sum$PAHcarc emission were 33.10 kg/year and 830.21 kg/year. (In case of incineration, the whole provisions of PARs and $\sum$PAHcarc contained to flowed in sludge was supposed to be exhausted to environment through exhaust after incineration.)

  • PDF

Estimation of polycyclic aromatic hydrocarbons emission from sewage sludge of sewerage treatment plants in Korea

  • Kim, Dong-Hwan;Hwang, Jong-Seob;Lee, Min-Hee;Ok, Gon
    • 한국환경과학회지
    • /
    • 제12권11호
    • /
    • pp.1167-1171
    • /
    • 2003
  • Polycyclic aromatic hydrocarbons (PAHs) are an important group of organic contaminants present in sewage sludge, due to their persistence, toxic, bioaccumulative and long range transfer. These characters make themselves as Persistent Organic Pollutants(POPs) in Long Range Transboundary Air Pollutions convention(LRTAP) of Europe. A method of the gas chromatographicmass spectrometric (GCMS) determination of PAHs present in sewage sludge was developed and applied to analyzed samples from five sewerage treatment plants (SWTPs), having different treatment types. PAHs were extracted from freeze-dried samples by toluene 16 hours in a soxhlet extraction system. The sludge extracts were cleaned-up by an activated silica gel column chromatography. The sum of the 16 US Environmental Protection Agency PAHs sewage sludge samples varied from 2.44 to 4.82 $\mu\textrm{g}$/g. Concentration of emission carcinogen PAHs(PAHcarc), such as Benzo(a)anthracene, Benzo(b)f1uoranthene, Benzo(k)f1uoranthene, Benzo(a)pyrene, Dibenzo(a,h)anthracene and Indeno( 1,2,3-cd)pyrene ranged from 0.62 to 1.03 $\mu\textrm{g}$/g. The total amount of PAHs emission from sewage sludge in Korea was calculated as a top-down approach. PAHs and $\Sigma$PAHcarc from sewage treatment plants had emitted to environment by several pathway. The highest amount of emission to the environment was remarked in the ocean dumping(PAHs and $\Sigma$PAHcarc emissions were 1155.95 kg/year and 5040.32 kg/year, respectively).

하수처리시설에서 인 고도처리를 위한 자동제어시스템 개발에 관한 연구 (Development of the Automatic Control System for the Advanced Phosphorus Treatment in Sewage Treatment Plant)

  • 김선국;이호식;전태성
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.300-304
    • /
    • 2012
  • It has a limitation to satisfy the phosphorus effluent criteria of 0.2 mg/L which will be reinforced from 2012 with the Biological Nutrient Removal (BNR) process. The chemical coagulation process has been operated in parallel with the biological treatment process for advanced treatment of phosphorous in the developed countries including Europe. However, the coagulation process has some disadvantages such as the desired goal may not be achieved without injecting the optimum dosage of the coagulant. This study developed the automatic control system to inject the optimum dosage of phosphorous coagulant into the coagulation process. The adopted coagulant was 10% Poly Aluminum Chloride (PAC) in this study. The automatic control system developed in this study was adopted for the treatment of the phosphorus from the effluent in SBR process. The automatic control system was composed of the data receiving part, the optimum coagulant dosage control part and the data transmit part. The result of the phosphorous advanced treatment of the SBR effluent using the automatic control system showed the removing efficiency over 95% consistently with the phosphorous concentration under 0.02 ~ 0.15 mg/L. The reproducibility analysis for checking the safety of automatic control system showed more than 95% correlation.

EQPS 모델을 이용한 하수처리장 운전 평가 (Evaluation of Operational Options of Wastewater Treatment Using EQPS Models)

  • 유호식;안세영
    • 한국도시환경학회지
    • /
    • 제18권4호
    • /
    • pp.401-408
    • /
    • 2018
  • 하수처리 공정모델링 소프트웨어인 EQPS(Effluent Quality Prediction System, Dynamita, France)를 적용하여 A하수처리시설 생물반응조 설계의 적합성을 분석하였다. A하수처리장은 친수용수 수준의 목표수질을 준수하기 위하여 이차침전지 유출수 설계농도를 총질소와 총인, 각 10 mg/L, 1.8 mg/L로 설정하여 설계하였다. 4-Stage BNR 공정인 반응조의 체류시간은 총 9.6시간으로 전무산소조 0.5, 혐기조 1.0, 무산소조 2.9, 호기조 5.2시간이었다. 동절기 공정모델링 결과 친수용수 수준의 목표수질을 만족하기 위하여 혐기조의 체류시간을 0.2시간 늘렸고 당초 설계조건이던 외부탄소원 비상시 주입을 상시적으로 주입해야 하는 것으로 조사되었다. 모델링 결과의 왜곡을 배제하기 위하여 소프트웨어 제조사가 제시한 one step nitrification denitrification 모델의 Default 계수를 사용하였다. 공정모델링은 대체적으로 최적의 상태를 제시하기 때문에 생물반응조 여유율을 고려하면 4-Stage BNR의 체류시간은 9.8시간보다 증가시켜야 한다. 하수처리장 설계단계에서 공정 모델링의 정확한 사용은 하수처리장 건설 후 처리성능과 효율의 안정성을 담보할 수 있는 방법이므로 설계단계에서 철저한 평가가 필요하다.

폐플라스틱용기 미디어를 활용한 오수고도처리 (Advanced Treatment of Sewage Using Waste Plastic Vessel Media)

  • 김재용;엄명헌;안대현;심명진
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.58-61
    • /
    • 2006
  • 본 연구는 폐플라스틱용기 미디어 산화공법을 이용하여 유체 및 산소전달 효율 향상을 위한 개조 방법과 미생물 부착특성을 향상시키는 방법을 통하여 오수고도처리 함을 목적으로 하고 있다. 또한 실험실 규모의 실험에서 최적의 담체 층진율과 충진 방법을 도출함으로써, 실 규모 설비를 위한 최적 설계 인자와 운전인자를 확보하고, 오수의 고도처리를 위한 다양한 운전조건을 제공하여 폐플라스틱 용기를 미생물 담체로 사용할 경우 생물학적 반응에 의해서 분해 될 때 소비되는 산소량과 오수중에 현탁되어 있는 유, 무기성 부유물과 질소 제거가 이루어지는 메카니즘을 규명하고 오수 처리 효율 향상을 위한 운전인자 도출을 목표로 한다.