• Title/Summary/Keyword: sewage system

Search Result 641, Processing Time 0.035 seconds

Hydrogeochemistry and Microbial Community Structure of Groundwater in an Agricultural Area (농업지역 지하수의 수리지화학 및 미생물 군집 구조 분석)

  • Kim, Dong-Hun;Oh, Yong Hwa;Lee, Bong-Joo;Lee, Jung-Yun
    • Journal of Soil and Groundwater Environment
    • /
    • v.27 no.2
    • /
    • pp.61-75
    • /
    • 2022
  • This study evaluated the potential threat of agricultural and human activities to groundwater in the Noseong stream watershed, a typical agricultural area, through hydrogeochemical characteristics and microbial community analyses. The groundwater in the study area was Ca-SO4 and Ca-HCO3 types alluvial aquifer mainly used for agricultural and living purposes, and contained high levels of NO3- and Cl- ions generated from anthropogenic sources such as fertilizer, livestock wastewater, and domestic sewage. Proteobacteria was most abundant in all samples with an average of 46.1% while Actinobacteria, Bacteroidetes, and Cyanobacteria were dominant on an occasional basis. The prevalence of aerobic bacteria such as the genus Mycobacterium, Flavobacterium, and Sphingomonas suggests that groundwater was well connected with the surface layer. The potential pathogen Mycobacterium was detected in most samples, and other pathogenic bacteria were also widely distributed, indicating the vulnerability to contamination. Therefore, an integrated management system is required to secure the sustainable use of groundwater in agricultural areas with high groundwater dependence.

Assessment of Estuary Reservoir Water Quality According to Upstream Pollutant Management Using Watershed-Reservoir Linkage Model (유역-호소 연계모형을 이용한 상류 오염원 관리에 따른 담수호 수질영향평가)

  • Kim, Seokhyeon;Hwang, Soonho;Kim, Sinae;Lee, Hyunji;Jun, Sang Min;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.6
    • /
    • pp.1-12
    • /
    • 2022
  • Estuary reservoirs were artificial reservoir with seawalls built at the exit points of rivers. Although many water resources can be saved, it is difficult to manage due to the large influx of pollutants. To manage this, it is necessary to analyze watersheds and reservoirs through accurate modeling. Therefore, in this study, we linked the Hydrological Simulation Program-FORTRAN (HSPF), Environmental Fluid Dynamics Code (EFDC), and Water quality Analysis Simulation Program (WASP) models to simulate the hydrology and water quality of the watershed and the water level and quality of estuary lakes. As a result of applying the linked model in stream, R2 0.7 or more was satisfied for the watershed runoff except for one point. In addition, the water quality satisfies all within 15% of PBIAS. In reservoir, R2 0.72 was satisfied for water level and the water quality was within 15% of T-N and T-P. Through the modeling system, We applied upstream pollutant management scenarios to analyze changes in water quality in estuary reservoirs. Three pollution source management were applied as scenarios, the improvement of effluent water quality from the sewage treatment plant and the livestock waste treatment plant was effective in improving the quality of the reservoir water, while the artificial wetland had little effect. Water quality improvement was confirmed as a measure against upstream pollutants, but it was insufficient to achieve agricultural water quality, so additional reservoir management is required.

Development of Air Flow Calculation System for Sewage Treatment Plant according to Inflow Water Quality (유입수질에 따른 하수처리장 송풍량 산정 시스템 개발)

  • Shin Geol Kim;Wooseok Yeo;Deok-Hyeon Kim;Jong Kyu Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.486-486
    • /
    • 2023
  • 하수처리장 내 생물반응조에서는 유기물을 제거하거나 질산화(Nitrification) 반응을 일으키기 위하여 산소를 요구하고 있으며, 필요한 산소는 송풍기 운영을 통해 공급하고 있는 상황이다. 질산화 반응을 일으키기 위해서 처리장 내 일정 이상의 산소가 수중에 공급되어야 한다. 생물반응조내 용존산소가 부족할 경우 활성슬러지의 침전성이 저해되어 오염물질 저감 효율이 떨어지게 되며, 과도한 산소가 공급되어도 수처리의 효율은 개선되지 않으며 반응에 사용되지 않은 산소들은 대기중으로 방출된다. 또한 유입수질에 따라 실시간으로 반응조 내 필요한 산소는 달라지게 되므로 유입수질에 맞는 효율적인 하수처리장 운영이 요구되고 있다. 하수처리장 내 적절한 산소를 공급하기 위하여 많은 연구들이 활발하게 진행되어 왔으나 실제생물학적 처리시 요구되는 산소의 양을 산정할 수 있는 한계점을 지니고 있으며, 하수 성분, 용량과 같은 환경에 따라 차이를 보이고 있어 범용적으로 사용하기에는 어려움이 있다. 따라서 본 연구에서는 이러한 적용 한계점을 극복하기 위하여 하수도 설계 시 사용되어지고 있는 하수도 시설기준의 산소요구량 및 공기공급량 산정식을 통하여 유입수질에 따라 실제 하수처리장에 필요한 산소요구량 & 공기공급량을 산정하는 시스템을 개발하고자 하였다. 하수도 설계기준의 여러 가지 수식을 실제 하수처리장 내 필요한 요소로 변환시켜 범용적으로 사용가능한 시스템을 개발하였다. 본 연구에서 개발한 하수처리장 송풍량 산정 시스템 적용에 따른 송풍량 절감 효율을 비교분석하기 위하여 2021년 A하수처리장의 4월 월간 데이터를 활용하여 하수처리장에서 필요한 송풍량을 산정하여 실제 사용된 송풍량과 비교 분석하여 송풍량 절감 효율을 분석하였다. 본 연구의 결과를 바탕으로 실제 하수처리장 내 송풍량 산정 시스템을 도입하게 된다면 운전자 경험에 의존하고 있는 수동적인 제어 방식에서 벗어나 자율 제어를 통한 효율적인 하수처리장을 운영할 수 있어 송풍량 절감 및 탄소중립에도 이바지 할 수 있을 것이라고 판단된다.

  • PDF

Bisphenol a induces reproductive dysfunction in male mice

  • Young-Joo, Yi;Malavige Romesha, Chandanee;Dong-Won, Seo;Jung-Min, Heo;Min, Cho;Sang-Myeong, Lee
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.935-944
    • /
    • 2021
  • It has been suggested that bisphenol A (BPA), a known endocrine disruptor, interferes with the endocrine system, causing reproductive dysfunction. Recently, BPA has been found in waste water due to incomplete sewage purification, possibly threatening health through its ingestion via tap water. In this study, young male mice (6 - 7 weeks old) were administered water containing BPA (50 mg·kg-1) for four weeks, while control mice consumed water without BPA. Serum, epididymal spermatozoa and testicular sections were assessed after sacrificing the mice on day 28. No significant differences were obtained between the groups in the body, testis and seminal vesicle weights. However, the epididymal sperm motility and count levels were significantly reduced in BPA-fed mice. Significantly higher hepatotoxicity levels were also observed in mice ingesting BPA as compared to the control mice. The level of serum testosterone was reduced, and testicular sections revealed incomplete and irregular spermatogenesis in BPA-ingested mice. The sperm proteasomal-proteolytic activity level has been implicated in sperm function and is measured in motile spermatozoa using fluorometric substrates. High ubiquitin C-terminal hydrolase activity levels were observed in the control mice without BPA. During a mating trial, a low pregnancy rate (71.4%) was observed in females mated with males who had consumed BPA (100% in the control mice). Overall, BPA adversely affected spermatogenesis and quality, as indicated by decreased sperm motility, concentration and serum testosterone levels, resulting in reduced fertility competence.

Development of underground facility information collection technology based on 3D precision exploration (3차원 정밀탐사 지하시설물 정보 수집 기술 개발)

  • Jisong RYU;Yonggu JANG
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.4
    • /
    • pp.56-66
    • /
    • 2023
  • Safety accidents are increasing, such as changes in groundwater levels due to construction work or natural influences, or ground cave-ins caused by soil runoff from old water supply and sewage pipes. In addition, underground facility management agencies must make efforts to improve the accuracy of underground information through continuous investigation and exploration in accordance with the Special Act on Enhanced Underground Safety Management. Accordingly, in this study, we defined the configuration of equipment and data processing method to collect 3D precise exploration underground facility information and developed 3D underground facility information collection technology to ensure accuracy of underground facilities. As a result of verifying the developed technology, the horizontal accuracy improved by an average of 6cm compared to the existing method, making it possible to acquire 3D underground facility information within the error range of the public survey work regulations.

An Analysis of Suitable site of Constructed Wetland using High Resolution Satellite Image and GIS in Kyoung-An Stream (고해상도 위성영상과 GIS를 이용한 인공습지 적지 분석 -경안천을 대상으로-)

  • Koh, Chang-Hwan;Jin, Do;Ha, Sung-Ryong
    • Journal of Wetlands Research
    • /
    • v.10 no.2
    • /
    • pp.115-128
    • /
    • 2008
  • Various human activities such as the Urbanization and Industrialization are estimated the main factors to pollute the stream. Now days, numerous studies are carried out for managing non-point sources which have un-effect on water quality of streams by land-use and livestock. In case of Korea, a matter of concern that the management of Pal dang reservoir - the main water resources of the national capital region - has been occurring. Especially, large-scale constructed-wetlands are planned and constructed at the end of Kyoung-an stream. Additionally a lot of sewage treatment plants are newly installed and extended in this watershed. According to these efforts, water quality of Kyoung-an stream is predicted that would be improved. But the more detail and scientific analysis should be carried out for the water quality improvement, because, existing water quality improvement projects are not involved to analyze root of water quality deterioration and improvement plans. Therefore, this study aims to select suitable areas for constructed-wetlands and to calculate size of the constructed-wetlands for water quality improvement in Kyoung-an stream through the geographical pollutant distribution analysis and land-use pattern analysis by high resolution satellite image and suitable area analysis of constructed-wetlands by GIS(Geographic information system). The progress of this study is (1) to select maximum pollutant loaded area by geographical analysis based on water quality data, (2) to analyze land-use patterns using high resolution satellite image, (3) to select suitable areas of constructed-wetlands, (4) to calculate area and volume of chosen constructed-wetlands using GIS. Basically, sizes of constructed-wetlands are induced through the constructed-wetlands design index based on treatment ratio(provided by Korea Water Resources Corporation). As a result of this study, two areas are selected to construct constructed-wetlands. One of the area was $127,586m^2$ near by Yong-in sewage treatment plant, and the other area was $1,647m^2$ near by Ju-buk stream and Dae-dae stream.

  • PDF

Effect on Digestion Efficiency by Adding Microbial Agent in Mesophilic Two-stage Anaerobic Digester (중온2단혐기성소화조에 미생물제재 주입시 소화효율에 미치는 영향)

  • Jung, Byung-Gil;Kim, Seok-Soon;Kang, Dong-Hyo;Sung, Nak-Chang;Choi, Seung-Ho;Lee, Hee-Pom
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.3
    • /
    • pp.75-86
    • /
    • 2003
  • In the near future, the capacity of conventional anaerobic digester is thought to be insufficient because of the increase of the total solids from expansion of intercepting sewer, sewage quantity and direct input of night soil from near apartment districts. The objectives of this study was to investigate the improvement of digestion efficiency using microbial agent(Bio-dh). The system was a pilot-scale, two-staged, anaerobic sludge digestion system. The first-stage digester was heated and mixed. The agitation velocity of the first-stage digester was 120rpm. The second-stage digester was neither heated nor mixed. The Digestion temperature was kept at $35{\pm}1^{\circ}C$ The detention time of digester was 19 days. The dosage of sewage sludge and microbial agent were $0.65m^3/day$ and $0.5{\ell}/day$, respectively. The experiments was run for 25days. Three times a week, $COD_{Mn}$ and SS of effluent, TS, VS, and biogas production rate were measured. Temperature, pH, and alkalinity were measured daily. The results were as follows ; Without microbial agent, digestion efficiencies ranged 46.0%~50.9%(mean=48.6%), with microbial agent(Bio-dh), digestion efficiencies ranged 52.8%~57.3%(mean=54.2%). Consequently, microbial agent(Bio-dh) increased the sludge digestion efficiency about 12%. Also, Without microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 1,639mg/L, 4,888mg/L respectively. With microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 859mg/L, 2,405mg/L respectively. Consequently, microbial agent(Bio-dh) increased the removal efficiency of $COD_{Mn}$ and SS about 47.6% and 50.8%, respectively.

  • PDF

Designing a Decentralized Stormwater Management Corridor for a Flood-Prone Watershed using Surface Runoff Analysis (지표유출수 분석을 통한 상습침수유역의 분산식 우수관리통로 설계)

  • Lee, Seul;Lee, Yumi
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.3
    • /
    • pp.13-26
    • /
    • 2015
  • Many urban areas in Korea suffer from repeated flood damage during intensive rainfall due to an increase in impervious areas caused by rapid urbanization and deteriorating sewage systems. A centralized stormwater management system has caused severe flood damage in an area that has proven unable to accommodate recent climate change and a rise in precipitation. Most flooding prevention projects that have been recently implemented focus on increasing drainage system capacity by expanding the size of sewer pipes and adding pumping stations in downstream areas. However, such measures fail to provide sustainable solutions since they cannot solve fundamental problems to reduce surface runoff caused by urbanization across the watershed. A decentralized stormwater management system is needed that can minimize surface runoff and maximize localized retention capacity, while maintaining the existing drainage systems. This study proposes a stormwater management corridor for the flood-prone watershed in the city of Dongducheon. The corridor would connect the upstream, midstream, and downstream zones using various methods for reducing stormwater runoff. The research analyzed surface runoff patterns generated across the watershed using the Modified Rational Method considering the natural topography, land cover, and soil characteristics of each sub-watershed, as well as the urban fabric and land use. The expected effects of the design were verified by the retainable volume of stormwater runoff as based on the design application. The results suggest that an open space network serve as an urban green infrastructure, potentially expanding the functional and scenic values of the landscape. This method is more sustainable and effective than an engineering-based one, and can be applied to sustainable planning and management in flood-prone urban areas.

Physical and Chemical Analysis of Organic Wastes for the Establishment of Total Management System (유기성 폐기물 종합관리기술구축을 위한 물리·화학적 성상 분석)

  • Kim, Young-Koo;Phae, Chae-Gun;Choi, Hoon-Keun;Kim, Sung-Mi;Hwang, Eui-young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.1
    • /
    • pp.100-114
    • /
    • 2005
  • Organic waste, which is defined as wastes derived from various biological organisms that contain more than 40% of organic materials, is generated about 100 million tons per year in Korea. These organic wastes are now controlled by several governmental entities, under different rules and regulations, leading to the improper management and inefficient treatment. Therefore, integrated management system is primarily needed for the efficient recycling of organic waste. In this study, six kinds of organic wastes, which are food waste, sludges(sewage, waste water, night soil), animal excreta, animals and plants residues, and three kinds of recycling by-products(compost, feed, anaerobic digestion by-products) made of organic wastes, were analyzed for their physical and chemical characteristics. On the basis of this result, a possibility for the efficient recycling of organic waste was investigated.

  • PDF

Bacterial Community Shift during the Startup of a Full-Scale Oxidation Ditch Treating Sewage

  • Chen, Yajun;Ye, Lin;Zhao, Fuzheng;Xiao, Lin;Cheng, Shupei;Zhang, Xu-Xiang
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.1
    • /
    • pp.141-148
    • /
    • 2017
  • The oxidation ditch (OD) is one of the most widely used processes for treating municipal wastewater. However, the microbial communities in the OD systems have not been well characterized, and little information about the shift of bacterial community during the startup process of the OD systems is available. In this study, we investigated the bacterial community changes during the startup period (over 100 days) of a full-scale OD. The results showed that the bacterial community dramatically changed during the startup period. Similar to the activated sludge samples in other studies, Proteobacteria (accounting for 26.3%-48.4%) was the most dominant bacterial phylum in the OD system, but its relative abundance declined nearly 40% during the startup process. It was also found that Planctomycetes proliferated greatly (from 4.79% to 13.5%) and finally replaced Bacteroidetes as the second abundant phylum in the OD system. Specifically, some bacteria affiliated with genus Flavobacterium exhibited remarkable decreasing trends, whereas bacterial species belonging to the OD1 candidate division and Saprospiraceae family were found to increase during the startup process. Despite of the bacterial community shift, the organic matter, nitrogen, and phosphorus in the effluent were always in low concentrations, suggesting the functional redundancy of the bacterial community. Moreover, by comparing with the bacterial community in other municipal wastewater treatment bioreactors, some potentially novel bacterial species were found to be present in the OD system. Collectively, this study improved our understandings of the bacterial community structure and microbial ecology during the startup of a full-scale wastewater treatment bioreactor.