• Title/Summary/Keyword: sewage system

Search Result 641, Processing Time 0.025 seconds

A Study on the Improvement of Water Quality according to the Pollution Management Plan of Seomjin River Water System (섬진강수계의 오염원 관리방안에 따른 수질 개선에 관한 연구)

  • Won, Chan-Hee
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.514-527
    • /
    • 2018
  • This study formed a scenario to improve a water quality by expecting and analyzing a water quality of Jeollabuk-do Seomjingang water system, so calculated a result. As a result, it was analyzed that a water quality is improved at 15.32 % of the maximum BOD, 7.17 % of T-N, and 62.86 % of T-P according to domestic and livestock cut amount by reinforcing discharge water of sewage disposal plant and improving pollutant management plans. It was analyzed that supplementing various cut plans such as establishment of efficient cut plans, plans to decrease pollution loading amount, plans to increase sewage disposal efficiently, pollutant decrease through an expansion of sewage disposal area, and energy recovery from animal dung of Total Pollutant Load Management System, and developing a study on more efficient improvement plans of water quality by considering natural increase and economic development are efficient in an improvement in a water quality.

Tertiary Treatment of Sewage by Micro Bubble Ozone and BAF System (미세기포 오존과 생물여과 시스템을 이용한 생활하수의 3차 처리에 관한 연구)

  • Kang, Dong-Han;Jang, Young-Ho;Kim, Jong-Su;Kim, Keug-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.877-884
    • /
    • 2011
  • In this paper, the removal characteristics of dissolved organic carbon (DOCs) by micro bubble ozonation process and $O_3/UV$ process were comparatively studied. In the point of DOC removing reaction coefficient, micro bubble ozonation system and $O_3/UV$ process had not significant difference, $0.0120sec^{-1}$ and $0.0141sec^{-1}$. Therefore micro bubble ozonation process is more suitable for tertiary treatment of sewage in the point of installation and maintenance cost-reducing. The optimum ozone injection rate was 2.0 g $O_3/g$ DOC and HRT was 3 min for the micro bubble ozonation process. The removal efficiency of DOC and SUVA in micro bubble ozonation system was 32.8% and 58.3% respective. Biological aerated filter (BAF) process was installed to remove soluble organic material increased by micro bubble ozonation system. And the effluent BOD of BAF was below 1.0 mg/L. In the view of cost-effectiveness, $O_3/BAF$ process was more profitable than $O_3/UV/BAF$ process for tertiary treatment of sewage. In order to nitrify ammonia in the BAF process completely, $NH_4{^+}-N$ concentration in the influent water of BAF should be designed considering low water temperature in the winter season.

Automatic T-P Coagulation Control System using an EC in the MSBR Process - Full Scale Study - (MSBR 공정에서 전기전도도를 이용한 인 제거 자동제어시스템 - 현장 적용 중심 -)

  • Jang, Hee-seon;Lee, Ho-sik
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.90-96
    • /
    • 2017
  • Many sewage treatment plants have applied the advanced technology of chemical coagulant system to remove phosporus in Korea. However there are some problems for the injection of optimum coagulant dosage. In order to solve these problems, the research related to the more cost-effective automatic total phosphorus coagulation control system using an EC(Electrical Conductivity) have been in progress. This study was conducted by the same process and operation method as the Lab-scale for public small town sewage treatment plant. First, it confirmed the correlation among the EC, PO4-P and coagulant dosage in the Lab-scale MSBR(Membrane Sequencing Batch Reactor) process. Next, it analyzed that correlation coefficient of EC and the coagulant dosage was 0.92 in the Full-scale MSBR process. As a result, not only T-P removal efficiency was doubled but also it satisfied the effluent water quality standard in a stable manner. In addition, by applying the automatic control system using the EC, compared to the fixed coagulant injection system the coagulant dosage could be reduced by 28%.

Small Sewage Treatment Using Septic Tank and Sand Trench (부패조와 모래트렌치를 이용한 소규모 오수 처리)

  • 박영식
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • This study was carried out to treat sewage using sand trench combined with septic tank process in rural areas. In order to find optimum parameters, design and operation mode was changed from Run 1 to Run 4. In order to facilitate nitrification and T-P removal, diffuser and iron plate was installed in the 3rd trench of Run 2 period. The septic tank played a role as pre-application process of sand trench system. The removal efficiencies of COD, NH$_4$-N, T-P at steady state were 94.6%, 87.9% and 54.5%, respectively. Addition of diffuser and iron plate in the 3rd trench has increased the removal efficiencies of the NIL-N and T-P. In this system, denitrification were not occurred because of the high DO.

Comparison of Measured and Predicted Photovoltaic Electricity Generation and Input Options of Various Softwares (태양광 발전량 예측 도구별 입력 요소 분석 및 실제 발전량 비교에 관한 연구)

  • No, Sang-Tae
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.87-92
    • /
    • 2014
  • The objectives of this study are to investigate input variables of photovoltaic generation programs and to compare their prediction to actual generation of photovoltaic system in the C city hall and the C city sewage treatment plant. We investigated the actual amount of generation, the forecast amount of generation, the amount of solar radiation data, and calculated the relative errors. We simulated the photovoltaic system of C city hall and the C city sewage treatment plant located in Chungju using existing programs, such as SAM, RETSCREEN, HOMER, PV SYST, Solar Pro. The result of this study are as follows : Through examining the relative errors of monthly predicted and actual generation data, monthly generation data showed big errors in winter season?. Except winter season, actual amount of generation and the predicted amount of generation showed no large errors.

Overview and Trend of Small Hydropower Development in Korea (국내 소수력발전 기술개발 현황과 전망)

  • Lee, G.B.;Lee, E.W.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.735-741
    • /
    • 2005
  • We have studied the prearranged plan and the economy of a candidate site for the development of small hydro power. And also we have confirmed its economy by suggesting the technology of the unmanned operation and the selection of the water turbine generator which has a great efficiency, working rate and suitability to the topographical characteristics of various development sites, for example, irrigation reservoirs, water works pipes, sewage systems and cooling water of a steam power station. We proposed some opinions such as the better improvement of small hydropower industry the people' view, cooperation among industry/university/ research institutes, remote control/maintenance and goverment's legislature and supporting system etc.

  • PDF

Study on the Discharge Characteristics of Non-point Pollutant Source in the Urban Area of the Youngsan-River Basin (영산강 유역 도시지역의 비점오염원 배출특성에 관한 연구)

  • Jin, Young-Hoon;Park, Sung-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.4
    • /
    • pp.605-613
    • /
    • 2006
  • Discharge characteristics of non-point source pollutant and load amount of the discharge in the urban area were investigated in the Pungyeongjeong-stream basin and the Yongbong-stream basin in this present study. The land use of the studied basins were divided into paddy field, industrial complex area, combined sewage system, separate sewer system and point sources discharge. The descriptive statistics on the event mean concentrations (EMCs) of non-point pollutants by the the land use showed in the range of 4.43-32.28 mg/L for BOD and 8.27~56.17 mg/L for COD. The highest concentration was shown from the combined sewage system. The EMC of SS at the paddy field in the Pungyeongjeong-stream basin showed the highest range with the values ~ from 35.76 to 358.86 mg/L, which might have been influenced by a levee construction in the adjacent of the area. The relatively high concentration values of 4.43~32.28 mg/L and 1.617.13 mg/L emerged from TN and TP,respectively, at the discharge points of the both stream basins.

Shipboard sewage treatment by Sequence Batch Reactor utilizing Beneficial Microorganisms (유용미생물을 적용한 선박오수용 SBR공정에 관한 연구)

  • Kim, In-Soo;Lee, Eon-Sung;Ha, Shin-Young;Oh, Yeom-Jae;Ekpeghere, Kelvin I.;Koh, Sung-Cheol
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.10a
    • /
    • pp.36-37
    • /
    • 2010
  • Lab scale experiment was carried out to study applicability of BM (Beneficial Microorganisms) to the conventional SBR system for the shipboard sewage treatment. BM has been successfully applied to the wastewater treatment by the SBR process and hence this system maintained a stable effluent quality together with an increased treatment efficiency, meeting the requirements of IMO regulations. The SBR system facilitated by BM would be a suitable process for cruise ships in terms of the malodor control, treatment efficiency and operation conveniences.

  • PDF

Improvement on Sewerage Effluent Standard of Public Sewerage Treatment Plants (공공하수처리시설 수질기준 선진화 방안)

  • Yu, Soon-Ju;Park, Sang-Min;Kwon, Oh-Sang;Park, Su-Jeong;Yeom, Ick-Tae
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.276-287
    • /
    • 2013
  • Domestic sewage contains increasingly more pharmaceuticals and personal care products (PPCPs), due to rising use of medicines, health supplement food and daily necessities. And various types of industrial wastewater from pollution sources in treatment areas could flow into the public sewerage treatment plants (PSTPs) in metropolitan areas. The conventional PSTPs are designed to treat suspended solids, biodegradable organics, nitrogen and phosphorous from residential and industrial areas and public facilities. However, toxic, conventional, and non-coventional pollutants from non-domestic sources that discharge into sewer system as well as domestic source with various chemicals could not be treated in the conventional PSTPs and discharged untreated to public basin. In this paper we aim to consider the establishment system of effluent standard of PSTPs in comparison with water quality standard of water environment and wastewater discharge regulation. And also we suggest the necessity of regulations on the pretreatment of industrial wastewater as part of efforts to improve water quality in sewerage systems and to protect public basin.