• 제목/요약/키워드: sewage facility

검색결과 152건 처리시간 0.026초

실규모 연속유입간헐폭기 공정(ICEAS)에서 최적운전조건이 경제성에 미치는 영향 (Economic implications of optimal operating conditions in a full-scale continuous intermittent cycle extended aeration system (ICEAS))

  • 정용재;최윤성;이승환
    • 상하수도학회지
    • /
    • 제38권1호
    • /
    • pp.29-38
    • /
    • 2024
  • Wastewater management is increasingly emphasizing economic and environmental sustainability. Traditional methods in sewage treatment plants have significant implications for the environment and the economy due to power and chemical consumption, and sludge generation. To address these challenges, a study was conducted to develop the Intermittent Cycle Extended Aeration System (ICEAS). This approach was implemented as the primary technique in a full-scale wastewater treatment facility, utilizing key operational factors within the standard Sequencing Batch Reactor (SBR) process. The optimal operational approach, identified in this study, was put into practice at the research facility from January 2020 to December 2022. By implementing management strategies within the biological reactor, it was shown that maintaining and reducing chemical quantities, sludge generation, power consumption, and related costs could yield economic benefits. Moreover, adapting operations to influent characteristics and seasonal conditions allowed for efficient blower operation, reducing unnecessary electricity consumption and ensuring proper dissolved oxygen levels. Despite annual increases in influent flow rate and concentration, this study demonstrated the ability to maintain and reduce sludge production, electricity consumption, and chemical usage. Additionally, systematic responses to emergencies and abnormal situations significantly contributed to economic, technical, and environmental benefits.

생태적 유역관리 도구로써 마을방죽의 수질정화 효율성 고찰 (A Study on Efficiency of Water Purification of Korean Village Bangjuk[dike] as a Means of Ecological Watershed Management)

  • 안병철
    • 한국전통조경학회지
    • /
    • 제30권2호
    • /
    • pp.90-100
    • /
    • 2012
  • 본 연구는 수생태계의 건전성 활용방안에 대한 연구를 마을방죽과 수체계의 원리에서 그 해답을 찾고자 하였으며, 연구대상지 10개의 마을방죽을 중심으로 분석하였다. 마을방죽의 수체계를 구성하는 우물, 공동샘, 마을수로 등 물 흐름을 이루고 있는 구성요소들의 구조와 특성에 대한 이해를 바탕으로 마을방죽의 사회적 생태적 역할 및 도시화로 인해 훼손되거나 소멸된 수생태계 건전성 확보와 생태적 유역관리를 위한 하나의 도구적 방안으로서의 결론은 다음과 같다. 1. 마을방죽은 마을에서 발생하는 배출수와 방죽보다 높은 수위의 농경지에서 흘러드는 농수로를 통해 물을 방죽에 모아서 농업용수로 재활용하고, 그 이상의 물은 논도랑을 통해 하천으로 흘려보내는 구조로서, 각 마을에서 발생하는 유출수를 효율적으로 관리하는 생태적 유역관리를 일상에서 실천하고 있었던 것이라고 볼 수 있다. 단순한 물 흐름의 일시적 저류시설이 아니라, 이를 다시 재사용하고 걸러서 하천으로 보내는 일종의 친환경수처리 시스템인 것이다. 2. 전통마을 5개소와 근대화 이후 농촌마을 5개소를 중심으로 사례대상지 10개의 마을방죽을 선정하여 마을의 수 체계와 방죽의 구조, 물 흐름을 분석하여 방죽의 유형을 분류하였다. 마을방죽의 유형은 소택습지형, 자연유하의 물흐름 구조인 수고답저형, 인위적 수리시설이 필요한 수저답고형 등 3가지 유형으로 분류되었다. 사례연구 대상지 중 전통마을 5개소는 모두 소택습지형으로 나타났으며, 근대화 이후 농촌마을 중 계지마을, 산제리마을, 마암마을, 양촌마을은 수고답저형으로, 상천리마을은 수저답고형으로 분류되었다. 3. 소택형 방죽과 수고답저형 방죽, 수저답고형 방죽으로 분류된 사례대상지의 수질분석을 통해 마을방죽의 수질정화 기능을 확인하였다. 마을하수도 유출수와 생활하수의 영향을 받는 원터마을과 계지마을에서는 암모니아성질소($NH_3-N$)와 총인(T-P)의 효율이 56~95%로 높은 것을 볼 수 있으며, 축사와 농경지의 영향이 강한 상천리와 산제리 마을에서는 부유물질(SS)이 70~85%, 총질소(T-N)와 총인(T-P)이 5.3~65%의 효율로 나타났다. 4. 오염원의 침전과 여과, 식물에 의한 탈질작용을 통해 마을에서 유출되는 생활하수, 마을하수도 배출수, 우수유출수 및 비점오염원들이 하천에 유입되기 전에 다시 한번 걸러주게 되는 수질정화 시스템을 마을방죽의 구조에서 확인할 수 있다. 이러한 구조를 통해 마을방죽은 생태적 유역관리를 위한 기초적 시설로서 활용되어져야 한다. 환경 필터층의 역할을 하는 마을방죽의 수처리 시스템은 단위유역, 집수유역 중심의 생태적 유역관리를 위한 친환경 시설로서 연구되어지고 활용되어야 한다.

반 건조 하수슬러지와 폐플라스틱 혼합물의 파일롯 규모 연속식 열분해에 의한 생산물과 발생 오염물질 (Products and pollutants of half dried sewage sludge and waste plastic co-pyrolysis in a pilot-scale continuous reactor)

  • 김용화;천승규
    • 한국응용과학기술학회지
    • /
    • 제34권2호
    • /
    • pp.327-337
    • /
    • 2017
  • 반 건조 소화 하수슬러지와 폐플라스틱을 혼합하여 파일롯 규모(85.3kg/hr)의 연속식 저온($510^{\circ}C{\sim}530^{\circ}C$) 열분해 실험을 하였다. 실험결과 열분해가스 발생량은 투입물 건량의 최대 68.3%, 발열량은 $40.9MJ/Nm^3$이었으며, 연속식 열분해에 따른 외기 유입율이 19.6%이었다. 오일은 투입물 건량의 4.2%가 발생하였고, 저위발열량은 32.5 MJ/kg이었으며 시설부식 등을 일으킬 수 있는 황과 염소의 함량이 각각 0.2% 이상이었다. 투입물 건량의 27.5%가 발생한 탄화물의 저위 발열량은 10.2 MJ/kg이었고, 용출시험 결과 지정폐기물에 해당하지 않았다. 열분해가스의 연소 배가스는 일산화탄소, 황산화물, 시안화수소 등의 배출농도가 특히 높았고, 다이옥신 (PCDDs/DFs)은 $0.034ng-TEQ/Sm^3$로서 법적 기준치 이내였다. 건조 배가스 응축으로 발생한 폐수는 수질오염물질 47개 항목 중 총질소, n-H 추출물질, 시안 등의 고농도 항목이 많아 전처리 후 하수처리장 등에서의 병합처리 방식을 고려할 필요가 있었다.

도농복합지역 지하수 함양과 배출에 대한 연구 (Groundwater Recharge and Discharge in the Urban-rural Composite Area)

  • 이병선;홍성우;강희준;이지성;윤성택;남경필
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권2호
    • /
    • pp.37-46
    • /
    • 2012
  • This study was conducted to identify groundwater recharge and discharge amounts of a representative urban-rural composite area located in Yongin city, Kyounggi-do, Korea. Groundwater recharge would be affected by mainly two processes in the study area: rainfall and leakage from public water pipelines including water-supply and sewage system. Groundwater recharge rate was estimated to be 13.5% by applying annual groundwater level data from two National Groundwater Monitoring Stations to the master regression curve method. Subsequently, the recharge amounts were determined to be $13,253{\times}10^3m^3/yr$. Leakage amounts from water-supply and sewage system were estimated to be $3,218{\times}10^3$ and $5,696{\times}10^3m^3/yr$, respectively. On the whole, a total of the recharge amounts was $22,167{\times}10^3m^3/yr$, of which 60% covers rainfall recharge and 40% pipeline leakage. Groundwater discharge occurred through three processes in the composite area: baseflow, well pumping, and discharge from urban infrastructure including groundwater infiltration into sewage pipeline and artificial extraction of groundwater to protect underground facilities from submergence. Discharge amounts by baseflow flowing to the Kiheung agricultural reservoir and well pumping were estimated to be $382{\times}10^3$ and $1,323{\times}10^3m^3/yr$, respectively. Occurrence of groundwater infiltration into sewage pipeline was rarely identified. Groundwater extraction amounts from the Bundang subway line as an underground facility were identified as $714{\times}10^3m^3/yr$. Overall, a total of the discharge amounts was determined to be $2,419{\times}10^3m^3/yr$, which was contributed by 29% of artificial discharge. Even though groundwater budget of the composite area was identified to be a surplus, it should be managed for a sound groundwater environment by changing deteriorated pipelines and controlling artificial discharge amounts.

부산지역 환경기초시설에서 발생하는 폐기물의 물리, 화학적 특성 규명 및 황화수소 발생량 예측에 관한 연구 (Physicochemical Characteristics and Estimation of H2S Emission Rate from Municipal Solid Waste at the Environmental Facilities in Busan City)

  • 이태윤;김도용;김재진;이준기
    • 한국지반환경공학회 논문집
    • /
    • 제10권2호
    • /
    • pp.13-20
    • /
    • 2009
  • 최근 우리나라의 국민들의 삶의 질이 향상됨에 따라 악취발생문제가 중요한 사회이슈가 되고 있다. 특히 환경기초시설에서 발생하는 악취물질로 인한 민원 중 약 67%가 하수처리장과 음식물쓰레기 처리시설에 의한 것으로 나타났으며, 해양오염방지법 시행규칙개정으로 2012년부터는 하수오니 등의 해양투기가 전면 금지될 예정에 있어 이들 시설의 처리량 증가에 따른 관리대책마련이 시급한 실정이다. 따라서 본 연구에서는 부산시 전역의 하수처리장과 음식물쓰레기처리시설중 상대적으로 폐기물발생량이 많은 5개 하수처리장과 5개 음식물쓰레기처리시설을 선정하여 슬러지 시료를 채집하고 이들 시료에 대한 공업분석, 원소분석, XRF 분석, 발열량분석 등을 통해 시료의 물리, 화학적 특성을 알아내었다. 또한 최종적으로 시료 내 황화수소 발생가능농도 측정을 통해 황화수소발생원단위를 산정, 악취민원의 근본적 대책마련을 위한 기초 자료로써 활용 하고자 하였다. 분석결과, 하수슬러지의 황화수소농도는 평균 57.3mg/kg, 음식물쓰레기처리시설의 것은 19.7mg/kg이었다. 최종적으로 총 10개 시설 폐기물의 황화수소 발생원 단위 산정결과 16,017,910.0mg/d로 예측 되었다.

  • PDF

하수도 시스템의 효율적인 운영 및 유지관리를 위한 시스템다이내믹스 모형의 개발 (Development of a System Dynamics Model for the Efficient Operation and Maintenance of Sewerage Systems)

  • 박수완;이태근;김봉재;김태영
    • 한국수자원학회논문집
    • /
    • 제45권1호
    • /
    • pp.101-111
    • /
    • 2012
  • 본 논문에서는 시스템 다이내믹스(System Dynamics, SD) 방법론에 입각하여 하수도 시스템의 운영지표들과 이에 영향을 미치는 외부변수들로 구성된 피드백 루프 메커니즘(Feedback Loop Mechanism)을 관로유지관리와 연관하여 규명하고, 외부변수의 변화에 따른 운영지표의 변화를 예측함으로써 하수도 시스템의 효율적인 운영 및 유지관리 방안을 모색할 수 있는 SD 컴퓨터 모의 모형(Computer Simulation Model)을 개발하였다. 개발된 모형에 부산광역시 하수도 시스템의 과거 운영 자료를 적용함으로써 모형을 검증하였고, 미래의 운영 상황을 예측하였다. 그 결과, 하수도보급률은 이미 목표치에 거의 도달하여 큰 변동이 없을 것으로 예측되었으며, 하수처리효율과 하수처리량, 요금현실화율은 점차 증가할 것으로 예측되었다. 또한 정책 지렛대의 발견을 위해 시스템에 큰 영향을 미치는 주요 운영지표를 선정하여 외부변수의 변화에 대한 민감도 분석을 수행하였는데, 그 결과 관로 유지관리와 연관된 외부변수는 하수처리효율의 변화뿐만 아니라 시설이용률, 하수처리량 등의 변화에도 큰 영향을 미치는 것으로 분석되었다.

비수용성 위생용품 사용에 따른 물재생센터 개선방안: 서울시를 중심으로 (Study on the Improvement of Water Regeneration Center by Using Non-water-soluble Sanitary Products: Focusing on the case of Seoul City)

  • 김충곤;배윤환;신현곤
    • 유기물자원화
    • /
    • 제31권2호
    • /
    • pp.39-44
    • /
    • 2023
  • 본 연구는 비수용성 위생용품의 수요와 공급이 증가하고 있는 상황에서 분뇨 및 하수처리시설의 물재생센터 처리과정중 비수용성 위생용품 관련 문제점을 분석하여 그 개선방안을 마련하고자 수행하였다. 그 결과, 물재생센터의 개선방안은 전처리설비에 주안점을 두어야 할 것이며 향후 설비교체시 하수처리시설의 경우에는 현실에 맞는 각종 제진기 설치를 제안하며, 분뇨처리시설은 조목스크린과 협잡물종합처리기 연계 또는 협잡물종합처리기 단독설치하는 방안을 제안한다. 또한 분뇨처리시설은 우선적으로 협잡물종합처리기 전단에 미세스크린을 설치하여 비수용성 물질을 분리하여야 하며 협잡물처리기의 유지관리 공간 확보가 필요하다.

지하시설물 3차원 모델 연결부 보정 및 요철보정에 관한 연구 (A study on the correction of the connection part of the underground facility 3D model and the correction of irregularities)

  • 김성수;한규원;허성서;한상훈
    • 한국측량학회지
    • /
    • 제39권6호
    • /
    • pp.429-435
    • /
    • 2021
  • GPR (Ground Penetrating RADAR)은 도로의 포장 상태 및 싱크홀, 지하관로를 검사하는 센서로 도로관리에 지하공간통합지도는 지하에 매설된 지하시설물(상수, 하수, 가스, 전력, 통신, 난방), 지하구조물(지하철, 지하차도, 지하보도, 지하주차장, 지하상가, 공동구), 지반(시추, 관정, 지질)의 총 15종의 지하정보를 3차원 기반에서 한눈에 확인할 수 있도록 구축한 지도를 말한다. 본 연구는 2차원의 지하시설물 데이터를 3차원 기반의 지하공간통합지도(지하시설물 3차원 모델)로 변환함에 있어 발생하는 관로별 연결부위 처리 문제와 지하시설물 관로의 요철문제를 보정하는 기술을 개발하는 것을 목적으로 한다. 이를 위하여 우선 지하시설물 데이터를 3차원 기반으로 생성하는 기술에 대한 국내·외 현황을 조사·검토하였으며 실제적인 문제 해결을 위하여 곡면보정 알고리즘과 요철보정 알고리즘을 개발하였다, 곡면보정 알고리즘은 2차원의 라인을 3차원의 원통으로 만들어 연결하는 경우 접합부위가 자연스럽게 연결될 수 있도록 고안하였으며 요청보정 알고리즘은 한 개의 단위 관로에 여러 개의 버텍스가 포함되어 이를 3차원 모델로 만들었을 때 발생하는 요철현상을 해결할 수 있도록 고안하였다. 개발된 알고리즘을 검수하기 위하여 알고리즘이 적용된 보정프로그램과 뷰어프로그램을 개발하였다. 위와 같은 과정을 토대로 지하시설물 3차원 모델을 현실과 동일하게 제작할 수 있었다. 본 연구는 지하공간통합지도의 활용도 제고를 위한 기반 연구로써 그 의의가 있을 것으로 판단된다.

시스템다이내믹스를 활용한 도시개발밀도의 적정성 평가 모델 구축 연구 (Establishment of the Measurement Model about the Adequate Urban Development Density using System Dynamics)

  • 전유신;문태훈
    • 한국시스템다이내믹스학회:학술대회논문집
    • /
    • 한국시스템다이내믹스학회 2003년도 하계학술대회발표논문집
    • /
    • pp.1-24
    • /
    • 2003
  • The purpose of this paper was developing a development density control model for urban growth management, using system dynamics modeling. The density control model was developed to see how urban growth, transition, and decay occur depending on the interaction among population, houses, industry structure, land and urban infrastructure such as road, water supply, and sewage treatment facilities. Suggesting adequate level of development density control using the model was another purpose of this paper. The model was applied to An'yang city to estimate the maximum number of population, industry structures, houses, and cars that can be adequately sustained with the current An'yang city's infrastructur capacity. The computer simulation results shows that the city is overpopulated by some 90,000 people. To reduce the population to the adequate level that the current urban infrastructure can sustain, the current city regulation on floor area ratio are needed to be strengthened at least 20 to 35%.

  • PDF

하수처리공정에서 이산화탄소를 이용한 스트러바이트 제어에 관한 연구 (A study of struvite control using CO2 in sewage treatment process)

  • 한금석;홍성호;최영준
    • 상하수도학회지
    • /
    • 제32권3호
    • /
    • pp.261-268
    • /
    • 2018
  • Sludge transporting pipes in wastewater treatment plant are easy to be clogged with struvite when the digested sludge and dehydrated filtrate are transported through the pipes, which lowers the efficiency of sludge treatment system in a WWTP. pH is one of the most important factors in struvite formation, and carbon dioxide separated from biogas can be used to control pH and struvite formation. By controlling pH, the amount of dehydrating agent can be reduced by about 10%, which saves the budget for facility maintenance. As $CO_2$ is reused and dehydrating chemicals are saved, the approach can contribute to global warming gas reduction.