• Title/Summary/Keyword: sewage disposal plant

Search Result 63, Processing Time 0.037 seconds

Effects of Mixing Ratio and Organic Loading Rate of Acid Fermented Food Wastes and Sewage Sludge on the Anaerobic Digestion Process (음식물찌꺼기 산발효산물과 하수슬러지의 혼합비 및 유기물부하가 병합처리에 미치는 영향)

  • Ahn, Chul-Woo;Park, Jin-Sik;Jang, Seong-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.247-256
    • /
    • 2006
  • This study has been conducted for the process of food wastes disposal using surplus capacity of established sewage treatment plant by co-digestion of fermented food wastes and sewage sludge after thermophilic acid fermentation of food wastes. The co-digestion of thermophilic acid fermented food wastes and sewage sludge was performed by semi-continous method in mesophilic anaerobic digestion reactor. It showed great digestion efficiency as the average SCOD and VS removal efficiency in organic loading rate 3.30g VS/L.d. were 74.2% and 73.6%, and the gas production rate and average methane content were 0.440 L/g $VS_{add}.d$ and 66.5%, respectively. Based on the results of this study, the co-digestion of thermophilic acid fermented food wastes and sewage sludge in sewage treatment plant is able to improve treatment efficiency of anaerobic digestion reactor and to dispose food wastes simultaneously, and was proved excellent economical efficiency comparing with any other treatment methods.

Development of Antimicrobial Concrete for Sewage Structures and Application to Construction Field (하수구조물용 항균콘크리트의 개발 및 현장적용)

  • Kim Moo-Han;Kim Gyu-Yong;Lee Eui-Bae;Lee Seung-Hoon;Sohn Yu-Shin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.3 s.21
    • /
    • pp.91-97
    • /
    • 2006
  • Sewage facilities are positively necessary for environment improvement such as rainwater removal, sewage disposal, preservation of the qualify of water and health of the citizens in present-day. Meanwhile, a deterioration of the concrete sewer pipe is increasing rapidly due to the chemical and physical attack and especially biochemical attack that is to say biodeterioration. In this study, researches for the development of antibiotics and antimicrobial concrete were conducted to reduce biochemical corrosion of sewage concrete. First of all, desired performance, such as watertightness, antibiosis, homogeneity, workability and harmlessness, was proposed and performance of antibiotics and antimicrobial concrete were evaluated by them. And developed antimicrobial concrete was applied to actual construction field. As results of this study, dispersibility and antibiosis of liquid antibiotics superior to powdery antibiotics. Antibiosis of antimicrobial concrete was verified, and amount of elution of harmful and effective ingredients was little. In workability, setting time of antimicrobial concrete was delayed. Compressive strength and resistance to carbonation of antimicrobial concrete were more increased than ordinary concrete. Finally, as there were no problems in quality and construction progress of antimicrobial concrete produced in plant, applicability of antimicrobial concrete to actual construction field was verified.

A study on the Effect of SOB(Sulfur-Oxidizing Bacteria) Media on the Removal of Hydrogen Sulfide in Water of Septic Tank (SOB(Sulfur Oxidizing Bacteria) Media가 정화조의 수중황화수소 제거에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil;Kim, Taeksoo;Kwon, Sucheol;Yu, Hyeongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.59-67
    • /
    • 2013
  • The odor occurring in the sewage system induces the displeasure, the disgust such as the headache, the vomit, etc. and increases the spiritual stress and disturbs the pleasant life of residents. These odors occur mainly in the area of combined sewage system treatment, being created in the personal sewage treatment plant such as septic tank and are incoming to sewage pipes and emitted to the outside through the manhole and the receiver, etc.; and this causes odors to the people. The Hydrogen Sulfide, the Methyl Mercaptan, the Ammonia, etc. are materials causing the odor, the more serious issue of odor is occurring since the septic tank of degradation process is being applied. The primary cause of odor is the decomposition of human feces in the septic tanks and sewage disposal facilities. The purpose of this study is reduction of hydrogen sulfide using air supplying and SOB(Sulfur-Oxidizing Bacteria). As a result of this study of the air supply system and the SOB media equipment by air supply, in case the air is injected to SOB media compared to the injection of air only, the removal efficiency the hydrogen sulfide was average 3.4 times higher.

A Study on the Evaluation of Fuel Characteristic and Economic Benefit for Co-combustion of Dried Sewage Sludge with Coal (건조 하수슬러지의 석탄 혼소를 위한 연료특성 및 경제성 평가에 관한 연구)

  • Kang, Jeong Hee;Kang, Jong Yun;Lee, See Hyung;Kim, Byung Tae;Lee, Nam-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.1
    • /
    • pp.11-19
    • /
    • 2014
  • A study on combustion characteristic and evaluation of cost benefit were carried out using dried sewage sludge to evaluate co-combustion with coal in a coal-fired power plant. In the result of proximate analysis, sewage sludge has 78.09%, 79.65% of moisture content in A STP(Sewage Treatment Plant) and B STP, respectively. The dried sewage sludges show 0.12, 0.14 of fuel ratio value, respectively and over 30,000kcal/kg of combustible index. It means that the dried sewage sludges needs to reform from the results of fuel ratio and combustible index. As a results of the economical benefit evaluation of dried sewage sludge, about 73.4 million won through using the dried sewage sludges instead of coal and 56.4 million won through REC(Renewable Energy Certificate) cost were saved, respectively. On the other hand, it occurs 4.2 million won of additional cost related to ash disposal and 2.6 million won of investment/operation cost for co-combustion facility. In conclusion, co-combustion of dried sewage sludges with coal in a coal-fired power plant saves about 123 million won. However, it needs to consider for power supply to produce dried sewage sludges and opportunity cost for environmental pollution and so on to evaluate more reasonable benefit of co-combustion.

Analytical Evaluation of Influent Depending on the Occurrence of Rainfall by Case Study of Wastewater Treatment Facility (하수처리시설 사례 별 강우발생 유무에 따른 유입수 분석 평가)

  • Choi, Langkyu;Chung, Jin Do
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.35-49
    • /
    • 2019
  • Currently in 2018, Korea has over 600 operating sewage disposal facilities. The law requires a sewage treatment plant to treat 500 tons or more of water per day, and a small-decentralized sewage treatment facility in a community to treat 50 tons or more to less than 500 tons of water per day. However, most facilities fulfill neither the quantity nor the quality requirements from the original design for such reasons as inflow of rainwater and ground water due to deterioration of pipelines and unauthorized input of wastewater in the pipelines. The research has selected 2 representative cases among the technical diagnosif sewage pipelines in many regions within the country to use it as the baseline of: hourly flowrate and BOD water quality analysis in both clear and rainy days, proper plant operation through inflow rate and ratio calculation, and diagnostic evaluation for deterioration of the pipelines and their accessary structures. This also suggests facilities that treats 500 tons or more of inflow per day to sample and analyze the water hourly for 24 hours once a week in both clear weather and rainy weather considering the influence of rainfall on a regular basis.

The Distribution and Standing Crop of Phytoplankton in the Nearby Streams of Suwon Sewage Disposal Plant (수원 하수종말처리장 주변 수역의 식물플랑크톤의 분포와 현존량)

  • Lee, Ok-Min
    • Korean Journal of Environmental Biology
    • /
    • v.19 no.4
    • /
    • pp.282-291
    • /
    • 2001
  • The distribution and standing crop of phytoplankton were investigated seasonally at 6 stations in the nearby streams of Suwon sewage disposal plant. It turned out to be total of 176 taxa, and classified as 4 phylums, 4 classes, 11 orders, 6 suborders, 22 families, 54 genera, 155 species, 20 varieties and 1 form by Engler's classification system. Among 176 taxa, 22 including Microcystis Aphanizomenon flos-aquae were identified as indicators of water pollution. Standing crops of all stations investigated appeared to be relatively high as in other streams through the center of the city, such as Kyoungan-chon of Youngin-si and Gulpo-chon of Buchon-si. In station 1,2,4 and 6, the highest number of standing crop were shown in summer, while in station 3 and 5, it was high in winter. Based on the present study upon the distribution and standing crop of phytoplankton, it is regarded as the state of the eutrophication in the nearby streams of Suwon sewage disposal plant.

  • PDF

Full Scale Study on The Optimum Conditions for Disposal of Sewage Sludge Cake by Using Continual Thermal Wind Dryer and Pyrolysis (연속적 열풍건조/열분해 Full Scale 장치를 이용한 하수슬러지 케익 처분을 위한 최적조건 연구)

  • Ha, Sang-An
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.3
    • /
    • pp.29-37
    • /
    • 2008
  • The objective of this research is to evaluate the optimum treatment methods for disposal sludge cake at different temperatures and periods of time. The disposal dehydrated sewage cake used in this study was obtained from N wastewater treatment plant in the P City. This system consists of continuous conveyer thermal dryer and pyrolysis. The continual conveyer thermal dryer was operated to evaluate the optimum conditions with temperature settings, ranges from 130 to $180^{\circ}C$, loading rates of 650~750 kg/hr and operating times of 110~120 minutes. The continual pyrolysis was also operated to evaluate the optimum conditions with temperature settings, ranges from 650 to $750^{\circ}C$, loading rates of 100~158 kg/hr and operating times of 20~40 minutes. The sewage sludge cake has a moisture content of 78~80% (wt) which decreased up to 1~3%(wt) resulted in breaking of cell wall after operating the continuous conveyer thermal dryer and pyrolysis. Important parameters which were operating times, moisture contents, loading rates, conveyer velocities and rotary velocities effects on the thermal kinetics and dynamics were investigated to evaluate the optimum conditions for the continual thermal dryer and pyrolysis.

  • PDF

Forward osmosis membrane filtration for microalgae harvesting cultivated in sewage effluent

  • Kim, Su-Bin;Paudel, Sachin;Seo, Gyu Tae
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.99-104
    • /
    • 2015
  • The purpose of this study is to evaluate the performance of forward osmosis (FO) system for harvesting microalgae cultivated in secondary sewage effluent. Microalgae species used in this study were chlorella sp. ADE4. The drawing agents used for forward osmosis system were seawater and concentrate of sea water reverse osmosis (SWRO) system. Chlorella sp. ADE4 cultured in secondary sewage effluent illustrated moderate efficiency in removal of total nitrogen (TN) (68%) and superior performance in total phosphorus (TP) removal (99%). Comparison of seawater and SWRO concentrate as drawing agent were made in FO membrane separation of the microalgae. The result from this study depicts that SWRO concentrate is strong drawing agent in FO membrane system providing an average dewatering rate of $4.8L/(m^2{\cdot}hr)$ compared to seawater with average dewatering of $2.9L/(m^2{\cdot}hr)$. Results obtained from this study indicated that FO system could be viable option for harvesting the microalgae for further biodiesel production. SWRO concentrate as a drawing agent could be very important finding in field of membrane technology for disposal of SWRO concentrate.

The Fractionation Characteristics of Organic Matter in Pollution Sources and River (오염물질 배출원과 하천에서의 유기탄소 분포 특성)

  • Kim, Ho-Sub;Kim, Sang-Yong;Park, Jihyung;Han, Mideok
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.5
    • /
    • pp.580-586
    • /
    • 2017
  • The fractionation characteristics of organic matter were investigated in inflow and effluent of each other pollution sources and river. While the DOC/TOC ratio in the influent of public sewage treatment plant and livestock disposal facilities was above 0.58, the POC/TOC ratio of human livestock Night soil treatment plant and stormwater runoff was more than 0.7. The TOC removal efficiency of public sewage treatment plant and human livestock Night soil treatment plant were 88.5 % and 99.6 %, respectively. Although the concentration distribution of organic matter pollution most of total organic carbon (TOC) in effluent of pollution sources accounted for dissolved organic carbon (DOC) type (DOC/TOC ratio >0.89) and Refractory-DOC (RDOC)/TOC ratio was higher (>0.65). The fractionation characteristics of organic matter in river were similar with that of sewage treatment plant and TOC concentration showed the positive correlation with DOC ($r^2=0.93$) and RDOC ($r^2=0.89$) concentration. The decay rate of Labile DOC (LDOC) (avg. $0.128day^{-1}$) was higher than labile particulate organic carbon (LPOC) ($0.082day^{-1}$), while that of DOC ($0.008day^{-1}$) was lower than POC ($0.039day^{-1}$) (paired t-test, p < 0.001, n = 5). These study results suggested that it should consider important both TOC and DOC as the target indicator to control refractory organic matter in pollution sources.

A Study on The Operation Characteristics of 2-Stage Compression Heat Pump using Treated sewage (하수처리수를 이용한 2단 압축 열펌프 시스템의 운전특성에 관한 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Lee, Young-Soo;Chang, Ki-Chang;Ra, Ho-sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.299-303
    • /
    • 2008
  • The treated sewage temperature is about $5^{\circ}C$ lower in summer and $5{\sim}10^{\circ}C$ higher in winter than ambient air. It can be used heat pump heat source and is good heat source on high performance of heat pump. In this study, to develop 100RT 2-stage compression heat pump use treated sewage water heat source and system applies to sewage disposal plant. Although heat pump is better performance, the large temperature difference between load and source makes the performance degradation of a heat pump. To solve this problem screw 2-stage compression is considered. The experiment was focused on the system operating performance variations over supply water and treated sewage water a temperature in the field. The results show that system of heating performance is higher then general heat pump and is enough to supply a hot water of $70^{\circ}C$.

  • PDF