• 제목/요약/키워드: setup variation

검색결과 104건 처리시간 0.027초

Investigations on the influence of radial confinement in the impact response of concrete

  • Al-Salloum, Yousef;Alsayed, Saleh;Almusallam, Tarek;Ibrahim, S.M.;Abbas, H.
    • Computers and Concrete
    • /
    • 제14권6호
    • /
    • pp.675-694
    • /
    • 2014
  • Annular and solid concrete specimens with different aspect ratios and static unconfined compressive strengths were studied for impact loading using SHPB test setup. Numerical simulations in LSDYNA were also carried out and results were validated. The stress-strain curves obtained under dynamic loading were also compared with static compressive tests. The mode of failure of concrete specimen was a typical ductile failure at high strain rates. In general, the dynamic increase factor (DIF) of thin solid specimens was higher than thick samples. In the numerical study, the variation of axial, hydrostatic and radial stresses for solid and annular samples was studied. The core phenomenon due to confinement was observed for solid samples wherein the applied loads were primarily borne by the innermost concrete zone rather than the outer peripheral zone. In the annular samples, especially with large diameter inside hole, the distribution of stresses was relatively uniform along the radial distance. Qualitatively, only a small change in the distribution of stresses for annular samples with different internal diameters studied was observed.

Feasibility Study of Tapped Inductor Filter Assisted Soft-Switching PWM DC-DC Power Converter

  • Moisseev S.;Sato S;Hamada S;Wakaoka M
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.231-234
    • /
    • 2003
  • This paper presents a novel high frequency transformer linked full-bridge type soft-switching phase-shift PWM control scheme DC-DC power converter, which can be used as power conditioner fur small-scale fuel cell power generation system. Using full-bridge soft-switching DC-DC converter topology makes possible to use low voltage high performance MOSFETs to achieve high efficiency of the power conditioner. A tapped inductor filter is implemented in the proposed soft-switching converter topology to achieve soft-switching PWM constant high frequency operation for a wide load variation range. to minimize circulating and idling currents without using additional resonant circuit and auxiliary power switching devices. The practical effectiveness of the proposed soft-switching DC-DC converter is verified in laboratory level experiment with 1 kW 100kHz breadboard setup using power MOSFETs. Actual efficiency of 94-96$\%$ is obtained for the wide load range

  • PDF

저압용 보텍스튜브의 노즐면적비에 따른 에너지 분리특성에 관한 실험적 연구 (An Experimental Study on the Energy Separation in the Ratio of Nozzle Area of a tow Pressure Vortex Tube)

  • 오동진;최정원
    • 에너지공학
    • /
    • 제13권1호
    • /
    • pp.34-39
    • /
    • 2004
  • 본 논문에서는 압축공기를 작동매체로 한 저압용 보텍스튜브에 대한 에너지 분리과정을 상세히 연구하였다 먼저 보텍스튜브에서 에너지 분리되어 나오는 온공기와 냉공기의 온도변화에 대하여 실험하였고, 보텍스튜브의 안쪽표면의 최대벽면온도 변화와 보텍스튜브 내의 온도분포를 통하여 보텍스튜브 내 유동장에서의 정체점의 위치에 대한 유용한 정보를 얻게 되었다. 이를 바탕으로 보텍스튜브의 노즐면적비와, 오리피스의 크기에 따른 에너지분리 과정 등을 실험을 통하여 알아보았다. 이러한 기하학적 형상의 변화실험을 통하여 저압용?대형 보텍스튜브의 에너지 분리과정이 고압형\ulcorner소형 보텍스튜브 보다 에너지 분리효과가 증대됨으로 인하여 최적의 노즐면적비와 오리피스지름비가 차이가 있음을 알 수 있었다.

목재단면(木材斷面)의 흡음계수(吸音係數)와 음향(音響)임피이던스 (Acoustic Absorption Coefficient and Impedance of Wood Sections)

  • 홍병화
    • Journal of the Korean Wood Science and Technology
    • /
    • 제17권2호
    • /
    • pp.26-33
    • /
    • 1989
  • The acoustic absorption coefficient and acoustic impedance of 5 species of softwood(sonamoo, sam namoo, gusang namoo, hwaback, sitka spruce) and 5 species of hardwood (Mulgusul namoo, Italian popular, white meranti, red meranti, kalantas) were measured by the standing wave method. which is simple in the setup and gives more accurate result than does any other measuring method. The dependence of the absorption coefficient and complex acoustic impedance on the wood sections. thickness of the sample itself and the back air gap was investigated experimentally in the frequency range from 200Hz to 1800Hz, and the result are as follows: 1. The acoustic absorption coefficient of wood sections was higher on the cross section than radial and tangential sections. 2) The acoustic absorption coefficient were higher in the frequency range from 400Hz to 600Hz, but decreased in the frequency above 600Hz. 3. The genenal tendency of the variation of the normal acoustic impedance was increased according to the frequency. 4. The acoustic absortion coefficient was increased in the to 7mm-thick sample and decreased in 9mm-thick sample. 5. The higher acoustic absorption coefficient was shown in the case with the backing an gap than in the case without the gap.

  • PDF

Research and Experimental Implementation of a CV-FOINC Algorithm Using MPPT for PV Power System

  • Arulmurugan, R.;Venkatesan, T.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1389-1399
    • /
    • 2015
  • This research suggests maximum power point tracking (MPPT) for the solar photovoltaic (PV) power scheme using a new constant voltage (CV) fractional order incremental conductance (FOINC) algorithm. The PV panel has low transformation efficiency and power output of PV panel depends on the change in weather conditions. Possible extracting power can be raised to a battery load utilizing a MPPT algorithm. Among all the MPPT strategies, the incremental conductance (INC) algorithm is mostly employed due to easy implementation, less fluctuations and faster tracking, which is not only has the merits of INC, fractional order can deliver a dynamic mathematical modelling to define non-linear physiognomies. CV-FOINC variation as dynamic variable is exploited to regulate the PV power toward the peak operating point. For a lesser scale photovoltaic conversion scheme, the suggested technique is validated by simulation with dissimilar operating conditions. Contributions are made in numerous aspects of the entire system, including new control algorithm design, system simulation, converter design, programming into simulation environment and experimental setup. The results confirm that the small tracking period and practicality in tracking of photovoltaic array.

공내수 전기전도도의 자동측정시스템 구축을 위한 실험 (An Experiment for determining Electrical Conductivity in Modelholes using Continuous Measurement System)

  • 김영화;박정빈;임헌태
    • 지질공학
    • /
    • 제13권3호
    • /
    • pp.281-292
    • /
    • 2003
  • 모형시추공 내에서 공내수 전기전도도의 자동 측정시스템을 구축하고 이로부터 수리상수 결정과 관련된 제반 기초 환경을 검증하였다. 실험은 상대적으로 높은 염도를 공내수로 하고 증류수를 지층수로 사용하여 지층수의 유입과 유출되는 유량을 일정하게 유지한 상태에서 공내수의 전기전도도 프로파일을 구하는 방식으로 이루어졌다. 관찰의 주 대상은 공내수와 지층수 사이의 염도차. 온도차 및 지층수의 유입량. 유입 ·유출구에 따른 모형시추공 내에서의 전기전도도 변화 양상 파악에 있었다. 실헌결과, 이들 요인이 미치는 영향범위와 적정 측정 환경이 제시되어 향후 모델 실험 및 원위치시험에서 적용될 기초실험 여건이 마련되었다.

병렬처리 그래픽 기술 기반의 Spectral Domain-Optical Coherence Tomography를 이용한 3차원 광 대역 망막 촬영 (High-Speed SD-OCT for Ultra Wide-field Human Retinal Three Dimensions Imaging using GPU)

  • 박기범;조남현;;김지현
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.135-140
    • /
    • 2013
  • We have developed an ultra wide-field of view Optical Coherence Tomography(OCT) which has capability to 2D and 3D views of cross-sectional structure of in vivo human retina. Conventional OCT has a limitation in visualizing the entire retina due to a reduced field of view. We designed an optical setup to significantly improve the lateral scanning range to be more than 20 mm. The entire human retinal structure in 2D and 3D was reported in this paper with the developed OCT system. Also, we empirically searched an optimized image size for real time visualization by analyzing variation of the frame rate with different lateral scan points. The size was concluded to be $1024{\times}2000{\times}300$ pixels which took 9 seconds for visualization.

Utilization improvement of PDMS and fluoropolymers by mutual application

  • Sihn, Youngho;Lee, Woojin
    • Membrane and Water Treatment
    • /
    • 제2권1호
    • /
    • pp.39-49
    • /
    • 2011
  • We investigated about the utilization improvement of the PDMS and fluoropolymers by mutual application in environmental analysis. We were conducted the direct fluorination with mild condition on the PDMS films and analyzed its surfaces before and after fluorination. The results of FTIR and SEM analysis on the PDMS films showed that the film surfaces were fluorinated without irreversible deformation by the fluorination. During the fluorination, the measured contact angles of water and several alcohols on the PDMS films decreased with time and that of most alcohols decreased to 0 after 30 minutes. The surface energy of fluorinated PDMS films has increased by 2 times. Also, we investigated the influence factors on the change of permeation rate of water through PDMS tubes with time. It was observed that the change of permeation rate of water through PDMS tube was affected by temperature, water phase and spatial distribution of water. From these results, we could verify the principal causes of the decrease of permeation rate of water through PDMS tube with time and proposed a new experimental setup for reducing the variation of permeation rate of water less than 2%.

시간지연 샘플링을 이용한 광섬유 격자 센서어레이의 선형 복조 (Linear interrogation of fiber Bragg grating sensor array using time-delayed quadrature sampling technique)

  • 김종섭;송민호
    • 한국광학회지
    • /
    • 제15권1호
    • /
    • pp.34-38
    • /
    • 2004
  • 파장가변형 광섬유레이저로 광섬유격자 센서어레이를 복조하는 방법을 제안하였다. 레이저의 출력파장을 시간지연 샘플링으로 분석하고 이를 이용하여 기존 시스템의 비선형적 동작특성을 개선하였다. 계산된 파장값은 센서어레이 출력파평의 각 피크에 할당되어 파장가변필터의 비선형성에 영향받지 않고 가해진 물리량에 대하여 항상 선형적인 출력을 얻게 하였다. 실험을 통하여 약 20 pm의 분해능을 얻었으며 이는 고속의 위상변조를 사용할 경우 크게 개선될 수 있음을 보였다.

환기용 축류팬의 가이드핀 블레이드 형상변화에 따른 유동특성에 관한 연구 (Effects of a Guide Fin Blade on the Flow Characteristics in a Ventilating Axial Fan)

  • 박홍광;이지근;노병준
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.874-882
    • /
    • 2007
  • The effects of a guide fin blade on the flow characteristics in a ventilating axial fan were investigated experimentally. The guide fins were setup onto the pressure surface of the blade, and their effects on the flowrate were evaluated. Two types of the guide fin blade were designed. One is the stem fin blade, and the other is the radial fin blade. The stem fin is designed normal to the circumference of a circle, and the radial fin is designed along the circumference of a circle. The results from the guide fin blade fans are compared with that of the blade without guide fins. The position and the geometry of the radial fin setting up on the blade have an effect on the increase of flowrate with the minor sacrifice of rotational speed of the blades. The radial fin positioning at 0.84 times blade diameter shows highest performance in the flowrate. The increase of the blade weight resulting from applying the guide fins shows minor effect on the variation of rotational speed of the blades.