• Title/Summary/Keyword: settling test

Search Result 130, Processing Time 0.032 seconds

A Study on Settling Properties of Cohesive Sediments in Shihwa Lake (시화호 점착성 퇴적물의 침강 특성에 관한 연구)

  • LEE YOUNG-JAE;LEE SANG-HWA;HWANG KYU-NAM;RYU HONG-RYUL
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.4 s.65
    • /
    • pp.42-48
    • /
    • 2005
  • The sediment of Shihwa Lake contains an abundant quantity of cohesive sediments. The transport processes of the cohesive sediments are complex and difficult to predict, quantitatively. The cohesive sediments are the primary reason for the pollution of the environment and water quality in the coastal region. In this study, a column test has been performed. In order to quantify the settling velocities of sediment from Shihwa Lake, an experiment was conducted using a specially designed 1.8m tall settling column. A series of settling tests and physico-chemical property tests on Shihwa Lake cohesive sediments has been conducted to investigate the correlation between settling properties and their physico-chemical properties, which are represented as grain size distribution, mineralogical composition, and percentage oj organic contents. Experimental results of physico-chemical property tests show that Shihwa Lake sediments are relatively large in average grain $size(74\mu m)$ contain very small organic $material(6\%)$, and are dominantly composed of Quarts, which has relatively low cohesion. Thus, Shihwa Lake sediments might be specified as those whose settling properties are more influenced by gravity than cohesion. It is concluded that the magnitude of settling velocities of muddy sediments can be quite different, regionally, and it implies that field or laboratory experiments for settling velocity measurement should be preceded over the numerical modeling of muddy sediment transport, in order to obtain the reliable prediction results for a given specific site.

Effective correlation between coagulation efficiency and the sludge settling characteristic (슬러지 응집효율이 침강특성에 미치는 상관관계에 대한 연구)

  • Han, Gee-Bong;Yoon, Ji-Hyun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.1
    • /
    • pp.151-159
    • /
    • 2006
  • In these days, the importance of sludge treatment is emerging due to the London Convention, so this study was conducted to propose the alternatives for the improved sludge treatment on the organic wastewater and sewage sludge with JAR test and settling column equipped with stirrer. The minimum coagulant dosage to earn the optimum sludge settling efficiency resulted from 200mg/l and each critical sludge settling interface showed no distinct difference when PAC was dosed over 200mg/l. Accordingly, Clarification Rate(CR) with 200mg/l dosage was calculated to CR=(Ho-Ht) / Ho=1-0.4=0.6 because the critical sludge settling height stopped at 0.4. The settling velocity of sludge interface was decreased with the increase of MLSS concentration but rather increased with MLSS concentration over 1,000mg/l. This resulted from positive effect of interacted coagulation for floc formation by transfer to the zone of compressed settling when MLSS concentration increased over 1,000mg/l. The settling velocity of sludge interface showed $28.66{\times}10^{-3}/min$ for average settling velocity of sewage sludge which is 6.7 times higher than $4.25{\times}10^{-3}/min$ for average settling velocity of organic wastewater sludge. The increasing rate of CR for organic wastewater activated sludge was higher than that of settling velocity under 200mg/l of PAC dosage but settling velocity was higher than CR over 200mg/l of PAC dosage. However, in case of sewage sludge, the differential rate of CR was low when PAC dosage was increased but the settling velocity was suddenly increased with over 200mg/l dosage. Therefore coagulation effect was more efficient to MLSS settling velocity rather than SS removal effect in the supernatant.

  • PDF

An Experimental Study on the Settling Behavior of Marine Fluid Mud In the West Seaside of Korea (Banweol area) (반월식역 해성토의 침강특성에 관한 실험적 연구)

  • 김수삼
    • Geotechnical Engineering
    • /
    • v.3 no.3
    • /
    • pp.49-62
    • /
    • 1987
  • The settling behavior of marine fluid mud in the west seaside of Korea has been studied with theoretical analysis and experimental technique. This paper describes laboratorial experiments on the sedimentation and the deposition of soil particles in seawater, with measurement of velocity of interface, the water contents, the settlement. And the reseults are compared with an earlier theoretical research, the hindered settling theory of Kynch, McRoberts and Nixon. According to the results the process of Banweol mud sedimentation showed the typical mode of the hindered settling under the condition of initial water content, wo=1000%. Also, the falling rates of fluid mud interface from initial settling height vs. the rising rates of soil deposit from the bottom of the test tub were measured by the function of time, the correlati tranship of them demonstrated as a straight line and obtained an experimental formula.

  • PDF

Design and Performance Evaluation of DC Generator Control System for Cortrolling Torque of Rotating Shaft (회전축의 정밀 토그 발생용 직류 발전기 제어장치의 설계 및 성능평가에 관한 연구)

  • Kim, G.S.;Kang, D.I.;Ahn, B.D.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.50-56
    • /
    • 1994
  • A DC generator control system was designed to control the torque of a rotating shaft precisely. The control system is composed of a strain gage type torque cell, a torque cell amplifier, a computer, a D/A converter, a error detector, a DC voltage amplifier and a resistor. The response test under unit step input and the dynamic stability test for the designed control system were carried out. It was confirmed that the settling time from the response test is about 4 s and the error from the dynamic stability test is less than 0.06% of rated output of torque cell. The designed control system may be used to control a DC generator which may be used to apply torque to a rotating shaft.

  • PDF

Evaluation of Hydraulic Characteristics Influenced by Different Deflector Baffles in the Sedimentation Basin with Inclined Plate Settler (경사판 침전지에서 저류벽의 설치위치에 따른 수리학적 특성의 평가)

  • Yu, Myong-Jin;Kim, Hyun-Chul;Ryu, Seong-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Sedimentation is one of the most common and important units in conventional water treatment plant. Structure such as various baffle walls and inclined plate settler may be obstacles to the horizontal flow when it is poorly designed. Therefore, the effects of these structures on characteristics of hydraulic flow must be evaluated to improve the settling efficiency of the floc. The hydraulic characteristic of the two sedimentations at Y water treatment plant (YWTP), which have different deflector baffles inside the settling basin, were investigated by tracer (fluoride) test. The inclined plate settler installed inside settling basin caused an undesirable impact on horizontal flow and produced dead zone. Solid baffle wall under the plate settler could help to minimize the formation of density currents and flow short circuiting. NaF used as a tracer was recovered more than 90% at investigated all basins. Morill index ($t_{90}/t_{10}$), Modal index ($t_p/T-HRT$) and short-circuiting index ($[M-HRT-t_p]/M-HRT$) were determined from tracer test results performed at YWTP. Those indices ranged 2.95~3.02, 0.40~0.53 and 0.32~0.46, respectively.

Evaluation of Solids Removal Characteristics on Sewage Treatment Plants Using T-P sludge Return into the Primary Settling Tank (총인슬러지의 1차 침전지 반송에 따른 하수처리장 고형물 제거특성 연구)

  • Kim, Jong-Oh;Jung, Dong-Gi;Kwon, Hye-Jeong;Hwang, Joon-Seok
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.73-80
    • /
    • 2018
  • In this study, the solids removal characteristics using T-P sludge generated from PACl coagulation were analyzed by laboratory scale and full scale experiment. As the amounts of T-P sludge injection into the raw sewage influent increased at the rate of 0, 1, 2, 3, 4 %, the suspended solids concentrations after 20 minutes setting test decreased to 210, 137, 91, 64, 43 mg/L, respectively. The filtration time required for dewatering test of the raw sewage influent decreased to 982, 728, 658, 581, 492 sec for 0, 1, 2, 3, 4% of T-P sludge injection, respectively. As the amounts of PACl coagulant into the effluent from final setting tank increased at 0, 10, 20, 30, 40 mg/L, the required filtration times for T-P sludge increased into 12.3, 41.7, 53.7, 67.2, 79.5 sec and the dewaterability of T-P sludge decreased. After T-P sludge returned into the primary settling tank on J-si sewage treatment plants, the effluent concentrations of COD, SS, T-N and T-P from primary settling tank into bioreactor decreased by 35.9, 27.9, 22.2, and 52.6% due to the coagulation effects of the T-P sludge. Finally, it was found that the return of T-P sludge into the primary settling tank could result into the sludge reduction having a lower water content of 3.03% p than in case of the only T-P sludge dehydration.

A Study on Settling Properties of Fine-Cohesive Sediments in Keum Estuary (금강 하구역 미세-점착성 퇴적물의 침강특성에 관한 연구)

  • Ryu Hong-Ryul;Chun Min-Chul;Hwang Kyu-Nam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.3
    • /
    • pp.251-261
    • /
    • 2006
  • The purpose of this study is to quantitatively estimate the settling property for fine-cohesive sediments in Keum Estuary and to evaluate the spatial variation by analyzing and comparing the local and seasonal variation of the settling properties in Keum Estuary with that of the settling properties in the other sites. After the spatial variation of physico-chemical properties such grain size distribution, the percentage of organic contents, mineralogical composition etc is investigated through experiments and analyses, interrelation between the physico-chemical properties and settling velocities and effect that the physico-chemical properties have on the quantitative variation of settling velocities were also analyzed in this study. Experimental results of settling tests shows that settling velocities of Keum Estuary mud vary in the range of two orders of magnitude (from 0.01 to 1mm/sec) over the corresponding concentration range of 0.1 to 80 g/L, and a feature of settling velocity profile is quite different in quantity as compared to those of previous studies with mud of other regions: Saemankuem, Tampa Bay, Sevem Estuary and lake Okeechobee. However, their local and seasonal variabilities within Keum Estuary appear to be insignificant.

Feasibility of Activated-Carbon Adsorbent to Sequester Sunken Hazardous and Noxious Substances (HNS) (흡착제를 이용한 침강 HNS 처리 및 현장적용 가능성 연구 - 현장 처리를 위한 활성탄소 활용 조건 검토 및 제안 -)

  • Choi, Ki-young;Kim, Chang-joon;Kim, Hye-eun;Jung, Jun-mo;Hwang, Ho-jin;Lee, Moonjin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.7
    • /
    • pp.858-863
    • /
    • 2020
  • We experimented with the particle-settling velocity and CHCl3 absorption efficiency of seven activated-carbon and analyzed seven heavy metal contents by elution for application to the field treatment of sunken HNS on the marine seabed. The mean particle-settling velocity was in the range 0.5-8 cm/s, except when the 8-20 mesh was used. The larger the HNS particle, the faster the particle-settling velocity was, and the CHCl3 absorption efficiency increased considerably owing to the larger surface area. In addition, the elution test results showed that the total Zn and As contents in >100-meshed activated carbon was higher than the contents criteria for the standard for water-treatment agents, and Cr, Zn, and As were released at higher concentrations than those released by other activated-carbon groups. Taken together, the CHCl3 absorption efficiency, settling velocity, and elution test results suggested that the 20-60, 20-40, and 2mm&down mesh activated-carbon adsorbents could be applied to the field treatment of HNSs and that the minimum required amount for field treatment were 0.82, 0.90, and 1.28 ton/㎘, respectively, as calculated based on the HNS-adsorption-capacity priority.

Relationship between Physical Property of Re-agglomerated Floc and Turbulent flow (난류모델을 이용한 재응집 Floc의 물리적 특성 연구)

  • Park, No-Suk;Kim, Seong-Su;Kim, Kwan-Youp;Kim, Jong-Oh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.103-108
    • /
    • 2010
  • Until now, research reports that it is difficult for brokenup floc after coagulation to reaggregate and settling efficiency of reaggregated floc is relatively low have dominated in water treatment process. In contrast, from recent study conducted by the French researcher, because the density of the reaggregated floc was higher than the previous floc, the settling efficiency of reaggregated floc increased. In this study, 15 times wet test were carried out and the removal efficiency of reagrregated floc was considerably increased. Moreover, this result was explained using the turbulent model for the flow occurred around the floc. Consequently, in the case of suitable hydrodynamic condition for the reaggregation, the characteristics of the reaggregated floc was changed into the favorable condition for improvement of settling efficiency. Also, the most important factor for reaggregation of floc was governed by hydrodynamic shear stress.

Development of NH3 Emission Factors using a Dynamic Flux Chamber in a Sewage Treatment Plant (부유형 챔버를 이용한 하수처리장에서의 암모니아 배출 특성 연구)

  • Jeon, Eui-Chan;Sa, Jae-Hwan;Park, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.263-273
    • /
    • 2005
  • In this study, the major emission procedures and emission characteristics were identified at the site of sewage treatment plant which is one of the major sources of ammonia. At the same time the emission factors and emission rates were estimated. In order to calculate the emission flux, we used a Dynamic Flux Chamber(DFC), which is found to be a proper sampling devise for area sources such as sewage treatment plant. It was found that the most stable sampling condition was when the stirrer's speed of DFC was 120RPM, and it would be the best time to take a sample 60 minutes later after setting the chamber. The relatively higher flux was shown in Autumn compared to summer and winter. Annual ammonia emission rates procedures were calculated as $906.32{\mu}g/activity-ton$, $1,114.72{\mu}g/activity-ton$ and $437.53{\mu}g/activity-ton$ each at the primary settling basin, aeration basin and the final settling basin, respectively. The ammonia emission rate the highest at in the aeration basin according to this test. This results was due to that the surface of aeration basin or the final settling basin is relatively wider than the primary settling basin.