초록

In this study, the solids removal characteristics using T-P sludge generated from PACl coagulation were analyzed by laboratory scale and full scale experiment. As the amounts of T-P sludge injection into the raw sewage influent increased at the rate of 0, 1, 2, 3, 4 %, the suspended solids concentrations after 20 minutes setting test decreased to 210, 137, 91, 64, 43 mg/L, respectively. The filtration time required for dewatering test of the raw sewage influent decreased to 982, 728, 658, 581, 492 sec for 0, 1, 2, 3, 4% of T-P sludge injection, respectively. As the amounts of PACl coagulant into the effluent from final setting tank increased at 0, 10, 20, 30, 40 mg/L, the required filtration times for T-P sludge increased into 12.3, 41.7, 53.7, 67.2, 79.5 sec and the dewaterability of T-P sludge decreased. After T-P sludge returned into the primary settling tank on J-si sewage treatment plants, the effluent concentrations of COD, SS, T-N and T-P from primary settling tank into bioreactor decreased by 35.9, 27.9, 22.2, and 52.6% due to the coagulation effects of the T-P sludge. Finally, it was found that the return of T-P sludge into the primary settling tank could result into the sludge reduction having a lower water content of 3.03% p than in case of the only T-P sludge dehydration.

키워드

참고문헌

  1. Jo, Y. M., Jang, M. J., Hong, Y. S. (2013), Improvement of T-P treatment facility on sewage treatment plants in Gyeonggi-Do, Gyeonggi Research Institute, 2013-67, pp. 3-5.
  2. Ministry of Environment. (2012), T-P treatment facility technical support casebook, pp. 4.
  3. Cho, S. B., Jang, H., Kim, M. G., Kim, S. J., Han, S. C. (2013), Study on Removal Feasibility of Nitrogeneous Malodor Compounds using $AlPO_4$ Zeolite Manufactured from Total Phosphorus Sludge, Korea Society of Waste Management, 30(7), pp. 734-740. https://doi.org/10.9786/kswm.2013.30.7.734
  4. Lee, S. M. (2014), A Study on landfill and solidification of sewage sludge total phosphorus, Kyungpook National University, Master Thesis, pp. 4-5.
  5. Dentel, S. K., Thomas, A. V., Kingery, K. M. (1989), Evaluation of the streaming current detector - I. Use in jar tests, Water Research, 23(4), pp. 413-421. https://doi.org/10.1016/0043-1354(89)90132-2
  6. Hyun, M. (2002), Determination of organic polymer addition method to improve dewaterbility of sludge, Gwangju University, Master Thesis, pp. 9.
  7. Balik, O. Y., Aydin, S. (2016), Coagulation/flocculation optimization and sludge production for pre-treatment of paint industry wastewater, Desalination and Water Treatment, 57(27), pp. 12692-12699. https://doi.org/10.1080/19443994.2015.1051125
  8. Carballa, M., Omil, F., Lema, J. M. (2005), Removal of cosmetic ingredients and pharmaceuticals in sewage primary treatment, Water Research, 39(19), pp. 4790-4796. https://doi.org/10.1016/j.watres.2005.09.018
  9. Cho, J. M. (2015), Evaluation of Dewaterability and Settleability of the Coagulated Flocs depending on the Floc Sizes, University of Seoul, Master Thesis, pp. 15-16.
  10. Jiang, J. Q., & Graham, N. J. (1998), Pre-polymerised inorganic coagulants and phosphorus removal by coagulation - a review, Water Sa, 24(3), pp. 237-244.