• Title/Summary/Keyword: settling test

Search Result 130, Processing Time 0.02 seconds

Application of Particle Size Analysis to Predict the Settleability of CSO Pollutants (입경분포 분석을 활용한 합류식 하수관거 월류수(CSO) 오염물질 침강성 예측)

  • Yoon, Hyun Sik;Lee, Doojin;Park, Young Suk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.295-302
    • /
    • 2006
  • Over the past decades, a flocculation and/or sedimentation process have been adopted to remove pollutants from CSOs. It has been learned that major factors affecting settlement of pollutants are the particle size distribution, their settling velocities and their specific gravity. It is, therefore, a good idea to analyze the particle size distribution and settleability of CSOs pollutants in order to develop details in designing a process. Discussed in this study are pollutant characteristics of CSOs such as particle size distribution and settleability of pollutants. The power law function is applied and is found to be an effective and reliable index for expressing the particle size distribution of pollutants in CSOs. Based on the regression analysis it is observed that the derived constants of curves representing settling velocity profile are proportional to the initial concentration of particles and to the ${\beta}$-values of power law distributions.

A Laboratory Study for Settling Velocities of Cohesive Sediments Entering in Semi-closed Channel (준 폐수로로 유입되는 점착성 퇴적물의 침강속도 산정을 위한 실험적 연구)

  • Kim, Dong-Ho;Yang, Su-Hyun;Hwang, Kyu-Nam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.5
    • /
    • pp.327-334
    • /
    • 2014
  • This study aims to estimate settling velocity ($W_s$) for cohesive sediments from water bodies (Incheon Coast, Kulpo Stream and Han River) mainly connected to the Kyeongin Ara-waterway through the laboratory settling experiments. Results of settling tests for these sediments show that $W_s$ values for sediments are quite different each other: $W_s$ values of Kulpo Stream sediments (0.01 < $W_s$ < 3.07 mm/s) are quite similar with those of Han River sediments (0.01 < $W_s$ < 2.97 mm/s) over the whole range of suspension concentration C (0.1 < C < 90 g/ L), while they are quite different with those for Incheon Coast sediments (0.01 < $W_s$ <0.92 mm/s). Qualitative analyses on test results for physico- chemical properties of sediments and waters with respect to settling velocities show that these differences in settling velocities are mainly due to the salinity difference in the water.

Settling and Filtering Process for the Treatment of Fine Suspended Solids and Soluble Heavy Metals in H Mine Drainage (H 광산배수 내 미세부유물질 및 용해성 중금속의 제거를 위한 침전 및 여과 공법에 관한 연구)

  • Oh, Minah;Kim, WonKi;Kim, DukMin;Lee, SangHoon;Lee, Jai-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.6
    • /
    • pp.102-111
    • /
    • 2012
  • Fine suspended solids generated effluence from treatment process of mine drainage could destroy environment as the aesthetic landscapes, and depreciate water quality. Therefore, the purpose of this research is focused on process development applied the actual field for controlling fine suspended solids and heavy metals, and so lab-scale test was performed for inducement of basic data. The mine drainage used in this research was sampled in H mine located Jeongseon-gun, Gangwon-do. Concentration of suspended solid, arsenic, iron and manganese was exceeded the standard of contaminant limitation for the clean water, and particle size of suspended solid was less than 10 m as fine particle. Although hydraulic retention time of mine drainage for effective settling was required more than 6 hours, hydraulic retention time would be increased in winter season when the settling efficiency could be reduced because of viscosity decreasing. Moreover, installed inclination plate helped to increase settling efficiency of suspended solid about 48 %. Filtering media that was the most effective removal of suspended solids and heavy metal was decided granular activated carbon of 1~2 mm was the optimal size.

Effects of Various Baffles on Hydraulic Characteristics in the Sedimentation Basin with Inclined Plate Settler (경사판 침전지의 수리학적 특성에 대한 구조물의 영향)

  • Yu, Myong-Jin;Kim, Hyun-Chul;Myung, Gyu-Nam;Ryu, Seong-Ho;Cho, Hang-Moon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.427-436
    • /
    • 2004
  • Sedimentation is one of the most common and important units in conventional water treatment plants. Structure such as various baffle walls and inclined plate settler may be obstacles to the horizontal flow when it is poorly designed. Therefore, the effects of these structures on characteristics of hydraulic flow must be evaluated to improve the settling efficiency of the floc. The hydraulic characteristic of the four sedimentations at the three real WTPs (water treatment plants), which have different structural properties respectively inside the settling basin, were investigated by tracer (fluoride) test. The inclined plate settler installed inside settling basin caused a undesirable impact on horizontal flow and produced dead zone. Intermediate baffle and solid baffle wall under the inclined plate settler at GE plant help to minimize the formation of density currents and flow short circuiting. However, installing perforated baffle under the inclined plate settler at other plants could not induce even distribution of flow. NaF used as a tracer was recovered more than 90% at investigated all basin. Morill index ($t_{90}/t_{10}$), Modal index ($t_p/T-HRT$) and short-circuiting index ($[M-HRT-t_p/M-HRT$) were determined from tracer test results performed at three WTPs. Those indices ranged 2.99~3.45, 0.44~0.72 and 0.23~0.47, respectively.

Modificaion and Performance Test for improving ability of Supersonic/Hypersonic Wind Tunnel(MAF) (초음속/극초음속 풍동(MAF)의 성능 향상을 위한 개조 및 검증)

  • Choi, Won-Hyeok;Seo, Dong-Su;Lee, Jae-Woo;Byun, Yung-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.717-722
    • /
    • 2010
  • Supersonic/Hypersonic wind tunnel is a facility which is intended to test and to observe the physical phenomena around a model by creating supersonic flow in the test section. In designing an airplane, the wind tunnel test is demanded to analyzing aerodynamic characteristics of the model without making a prototype. In this research, the model aerodynamic facility(MAF) is modified for the purpose of increasing running time and its functionality. New pneumatic valves for remote control was installed for safety requirement, and new air tanks was installed on MAF as well. A pipe system is also modified to use those new valves and tanks, and the ceiling and side glasses of the test section are switched to ones with the larger surface area. After the MAF modification, a test is performed at Mach 2, 3 and 4. In this test, shadow graph technique, one of the flow visualization methods, is used to visualize supersonic flow field. The pressure in the settling chamber and working section at Mach 2, 3 and 4 was measured in each case. As a result, the possible model size and running time are obtained.

  • PDF

Improvement of Cooling Water Quality by Coagulation and Sedimentation in Steel Mill (응집침전에 의한 제철공장 냉각수질향상)

  • Jo, Kwan-Hyung;Woo, Dal-Sik;Hwang, Byung-Gi;Lee, Seon-Ju;Park, Duck-Weon
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.5
    • /
    • pp.411-416
    • /
    • 2009
  • This study was initiated to improve the cooling water quality by chemical coagulation and sedimentation in steel mills. Due to the inefficient flocculation in the settling tanks of blast furnace cooling water systems, the solid particles in the cooling water overflow accumulate and clog the cooling system. To protect the cooling water system from such fouling, proper flocculants must be continuously used. Laboratory tests were performed for the indirect cooling water system of a plate mill. The batch test in the gas scrubbing cooling water system of a blast furnace showed that the proposed coagulant was more effective for the improvement of coagulation and sedimentation than the existing one. During the tests, cationic flocculants were more effective than use of only an anionic flocculant. The suggested combination of anionic and cationic flocculants can probably improve the turbidity removal efficiency of the cooling water. Proper control of the overflow rate by the designed residence time would help turbidity removal efficiency in the settling tank. In addition, the settling can be enhanced by adopting rapid and slow mixing alternatively. Scale problems in blast furnace cooling water system were reduced to some extent by efficient settling.

A Study on the Sediment Volume Change and Two-dimensional Deposited Characteristics of Pumping-dredged Soil (준설토의 체적변화 및 2차원 퇴적특성에 관한 연구)

  • 김형주;이민선;이용주;김대우
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.155-165
    • /
    • 2003
  • A series of one-dimensional cylinder sedimentation test, seepage consolidation test and two-dimensional deposition model test were conducted to examine the characteristics of deposition and volume change of dredged soils containing the high water content, and these experimental results were compared with the sedimentary conditions of actual dredged-reclaimed fields to obtain the relations of a volume change by settling what is required for design. In addition, the change of water content and the distribution of fine grained soils after sedimentation were investigated. Thus, it was concluded that deposition height increased lineary as substantial soil volume increased, and also the elevation of interface increasea proportionately at both the starting time and the finishing time of virtual self-weight consolidation in one-dimensional sedimentation. Furthermore, the two-dimensional model test results were shown to describe the plain distribution of water content and fine grained silt where dredged soil was deposited by two dimensional flowing, and the water content was distributed to wide range from the minimum water content 30% to maximum 180% according to the passed amount of №200 sieve percentage.

Preparation and Properties of Mixed Solvent Type Low Toxic Concentrated Oil Dispersant on Oil (혼합 용매계 저독성 농축형 유분산제의 제조와 광유에 대한 분산효율 특성)

  • Yeom, Kuy-Seol;Kang, Doo-Whan;Kim, Won-Ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.29-38
    • /
    • 1997
  • Low toxic concentrated oil dispersant using n-Paraffin and Di(ethylene glycol)mono butylether mixed solvent was prepared, and tested by oil dispersant performance test method, and oil dispersant efficiency was measured using vertical shaking method to 3 kinds of Crude oil, Bunker oil and W/O emulsions with different physical properties by appling the prepared dispersant. Although toxicity test was performed with Flat fish and Rock fish by appling the mixed oils emulsified using prepared oil dispersant, couldn't find the toxicity to them. Concentrated oil dispersant prepared has a good dispersion efficiency of 97.2% after 0.5min settling time and 28.3% after 10min settling time to Bunker B oil with 10% water solution. Especially, the concentrated oil dispersant showing the low toxicity to Oryzias Latipes(24hr, TLm) was 54,000 ppm and to Brine Shrimp Artemia(24hr, TLm) was 51,000ppm, and also, it was completely biodegradated to 99.1% after $7{\sim}8$days.

The Consideration in Terms of Pressure Probe Used in Experiments of Supersonic Wind Tunne II (초음속풍동 실험에서 사용하는 압력측정 Probe에 대한 고찰 II)

  • Lee, Jae-Ho;Lee, Yeong-Bin;Choi, Joong-Keun;Choi, Jong-Ho;Yoon, Hyun-Gull;Kim, Kyu-Hong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.359-363
    • /
    • 2011
  • In this paper, the characteristic of pressures had been analyzed with a series of shapes that are pressure probes used in supersonic wind tunnel. When a performance of supersonic wind tunnel is evaluated, the Mach number is calculated by using the ratio of static pressure in test section wall to total pressure in settling chamber. Also the flow condition can be visualized by schlieren system. However a number of limitations exist to measure pressure of test section due to high speed and boundary layer effect. Therefore a specific pressure probe is needed for evaluating flow condition in test section at a various of positions. In the paper, experiments were conducted in terms of some pitot probes and the results were compared and analyzed.

  • PDF

Conceptual Study of a Low-Speed Wind Tunnel for Performance Test of Wind Turbine (풍력터빈 성능시험을 위한 저속풍동 개념연구)

  • Kang, Seung-Hee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.19 no.4
    • /
    • pp.24-29
    • /
    • 2011
  • Conceptual study of an open-circuit type low-speed wind tunnel for performance test of wind turbine blade and airfoil is conducted. The tunnel is constituted of a settling chamber, a contraction, closed test section, a diffuser, two corners, a cross leg and a fan and motor. For the performance test, the closed test section width of 1.8 m, height of 1.8 m and length of 5.25 m is selected. The contraction ratio is 9 to 1 and maximum speed in the test section is 67 m/sec. Input power in the tunnel is about 238 kW and its energy ratio is 3.6. The wind tunnel designed in present study will be an effective tool in research and development of wind turbine and airfoil.