• Title/Summary/Keyword: settling efficiency

Search Result 171, Processing Time 0.024 seconds

Effects of Artificial Filaments Equipped in the Aeration Tank of Aerobic Fermentation System on the Removal Efficiency of Nitrogen of Swine Wastewater Containing High Nitrogen (담체설치가 고질소함유 양돈폐수의 호기발효에 미치는 영향)

  • 손경호;이상락;안정제;권윤정;정태영
    • Journal of Animal Environmental Science
    • /
    • v.6 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • This study was conducted to investigate the effects of artificial filaments equipped in the aeration tank of aerobic·fermentation system on the removal efficiency of swine wastes which were fermented an aerobically and thus containing high nitrogen. Two aerobic fermentation system each consist4s of 4 tanks ; storage tank, 1st and 2nd aeration tank and settling tank were run before and one or three weeks after equipment of artificial filament in the aeration tanks. Total solids concentration tended to increase by aerobic fermentation in all running periods. However, decreased(P<0.05) total nitrogen concentration was shown three weeks after the equipment of artificial filament. Ammonia nitrogen concentration also largely decreased(p<0.05) in both running periods of one and three weeks after equipment of artificial filaments. These results suggest that the artificial filaments may improve the removal efficiency of nitrogen in swine wastewater containing high nitrogen during aerobic fermentation.

  • PDF

Solid-liquid Separation of Swine Wastewater using Bentonite (벤토나이트를 이용한 양돈 폐수의 고액분리)

  • Yim, Je-Hyun;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.742-747
    • /
    • 2004
  • Solid-liquid separation of swine wastewater was conducted using bentonite as coagulant. During the separation experiment, coagulation efficiency was also investigated. To determine optimal bentonite dose, 0.1, 0.2, 0.4, 0.8, and 1.6% (w/v basis) of bentonite was dosed. Suspended solid removal efficiency was 87-98% at whole bentonite dosage. But sediment volume was increased, and settling velocity was decreased at excessive bentonite dosage. Therefore optimal bentonite dosage was evaluated around 0.2-0.4%. In the test to determine optimal pH, coagulation using bentonite was performed at pH 3, 4, 5, 6, and 7. At lower pH suspended solid removal efficiency was increased. However, sediment volume was also increased and phosphorus release was observed. Thereby optimal pH for bentonite coagulation might be appeared in the range of 6-7.

Collection Efficiency of Particles with Effect of Blocks in the Two-Stage Electrostatic Precipitator (2단식 전기집진기 내에서 블록의 영향에 따른 입자의 집진효율)

  • 박성호;박청연
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.217-218
    • /
    • 2000
  • 유해입자 배출 저감을 위한 대기오염 제어장치로는 필터(filter), 관성장치(inertialdevices), 침전조(settling), 스크루버(scrubber), 전기집진기(ElectroStatic Precipitator, ESP)등이 있다. 이 중, 정전기력을 이용한 전기집진기는 대전과정과 집진과정이 동일한 곳에서 이루어지는 1단식(one-stage)과 독립적으로 이루어지는 2단식(two-stage)으로 분류되며, 2단식의 경우, 대전부(charging section)와 집진부(collecting section)는 몇 개의 대전셀(charging cell)과 집진셀(collecting cell)들로 구성되어져 있다. (중략)

  • PDF

Effect of Physicochemical Parameter on PASS-100 Flocculation (PASS-100을 이용한 응집처리시 물리.화학적 인자의 영향)

  • 이상일;서인석;박승국
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.30-35
    • /
    • 1995
  • In this research effect of physicochemical parameter on flocculation using PASS-100 were evaluated. pEt flocculant dosage, mixing intensity and detention time were adopted as experimental variables. The physicochemical parameter( p% mixing intensity and mixing time ) were important Parameter on flocculation performance. Effluent pH range for effective flocculation was 4.5-7. Optimum Gt$_{d}$ range was 20,000-30,000 and its range similar to alum flucculation. Rapid mixing was very important parameter to floe formation in PASS- 100 flocculation. Whereas, slow mixing did not affect to the removal efficiency at settling time for 30minute or more.

  • PDF

Laboratory Investigation into Factors Affecting Performance of Anaerobic Contact Process for Pear Processing Wastewater

  • Hur Joon Moo;Son Bu Soon;Jang Bong Ki;Park Jong An;Lee Jong Whoa;Kim Joon Hyun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.2 no.2
    • /
    • pp.99-108
    • /
    • 1998
  • Results obtained from this research showed that the anaerobic contact process was applicable to pear waste with COD removal efficiencies of up to $95\%$ depending on conditions, provided ammonium and phosphate salts were added as well as other nutrients, present in the commercial fertilizer, Milorganite or in yeast extract. These latter materials were required in minimum concentrations of 5 and 1.5 g/L, respectively, in the feed independent of HRT and volatile solids loading rate, with part of the effect due to the mineral fraction. Digestion was satisfactory over the whole range of volatile solids loading rates and liquid retention time of 30 to 0.5 days tested, although treatment efficiency dropped off noticeably between 1 and 0.5 day liquid retention time because of poorer flocculation and separation of anaerobic bacteria. Settling of anaerobic bacteria including methane producing bacteria was related to settling of mixed liquor suspended solids only at 1 to 5 days liquid retention times, at other liquid retention times anaerobic microorganism settled markedly less efficiently than mixed liquor suspended solids. Further studies are being made to provide information of practical and basic interest. Data on the composition of the active fraction of yeast extract might solve many practical nutrient problems encountered with the anaerobic contact process and improve its economics. Further improvement in the flocculation and settling of anaerobic bacteria as well as other bacteria would improve overall performance and allow the use of shorter liquid retention times with dilute waste. Knowledge about the numbers of methane formers present would allow a degree of understanding and control of the process not presently attainable.

  • PDF

Effects of Various Baffles on Hydraulic Characteristics in the Sedimentation Basin with Inclined Plate Settler (경사판 침전지의 수리학적 특성에 대한 구조물의 영향)

  • Yu, Myong-Jin;Kim, Hyun-Chul;Myung, Gyu-Nam;Ryu, Seong-Ho;Cho, Hang-Moon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.427-436
    • /
    • 2004
  • Sedimentation is one of the most common and important units in conventional water treatment plants. Structure such as various baffle walls and inclined plate settler may be obstacles to the horizontal flow when it is poorly designed. Therefore, the effects of these structures on characteristics of hydraulic flow must be evaluated to improve the settling efficiency of the floc. The hydraulic characteristic of the four sedimentations at the three real WTPs (water treatment plants), which have different structural properties respectively inside the settling basin, were investigated by tracer (fluoride) test. The inclined plate settler installed inside settling basin caused a undesirable impact on horizontal flow and produced dead zone. Intermediate baffle and solid baffle wall under the inclined plate settler at GE plant help to minimize the formation of density currents and flow short circuiting. However, installing perforated baffle under the inclined plate settler at other plants could not induce even distribution of flow. NaF used as a tracer was recovered more than 90% at investigated all basin. Morill index ($t_{90}/t_{10}$), Modal index ($t_p/T-HRT$) and short-circuiting index ($[M-HRT-t_p/M-HRT$) were determined from tracer test results performed at three WTPs. Those indices ranged 2.99~3.45, 0.44~0.72 and 0.23~0.47, respectively.

A study on new treatment chemical for leather wastewater; I. Development of new organic coagulant (새로운 피혁폐수 처리제에 관한 연구; I. 새로운 유기 응결제의 개발)

  • Jung, Maeng-Joon;Lee, Chul-Jae;Han, Sung-Wook
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.4
    • /
    • pp.323-330
    • /
    • 2006
  • As the interest in environmental pollution resulting from recent industrial development is converging, wastewater treatment problem of dying processing is one of important pending issue. Usually, flow mediation earth and settling pond etc. of processing plant to handle water or wastewater. Mediation is the wastewater that flowed past settling pond than material of heavy particles, water weight colloid particles that big solids are removed but are suspensibility material settlement exclusion impossible. So, we need flocculation and coagulation action to remove materials from this colloid state. For flocculation and coagulation action chemical agents to add back, addition of chemical agents forms floc of could settle size. That is, shorten the sedimentation time and quality of processing water because promoting sedimentation doing to do fines or suspended solids and colloid can materials large size and also, flocculation to annex efficiency of filtration augment. Therefore, I executed this research to prove that improving organic matter and chromaticity of treated water of processing epochally using organic coagulant informed positive ion co-polymerization superior in color wastewater through this research.

  • PDF

A Study on the Solubilization and Dewaterability of Ultrasonically Treated Wastewater Sludge (초음파 처리한 하수 슬러지의 가용화와 탈수 특성 연구)

  • Youn, You-Sik;Kim, Dong-Jin;Yoo, Ik-Keun;Ahn, Dae-Hee
    • Journal of Environmental Science International
    • /
    • v.18 no.6
    • /
    • pp.675-682
    • /
    • 2009
  • Sludge minimization from wastewater treatment plant is becoming more important to save disposal costs and to contribute to sustainable development. For the reduction of sludge production, solubilization and dewaterability of sludge are important factors in sludge processing. Ultrasonic treatment has been used to enhance sludge solubility and dewaterability with anaerobic digestion sludge, primary sludge, and activated sludge. At the ultrasonic power of 0.2 kW/L for 1 hour, anaerobic sludge and activated sludge showed higher solubilization efficiency than the primary sludge in terms of COD, proteins, and suspended solids. Ultrasonic treatment decreased sludge dewaterability and sludge settling characteristics up to 720 kJ/L of ultrasonic energy. In conclusion, ultrasonic treatment was effective for sludge solubilization but it deteriorate dewaterability (specific resistance) and settling characteristics (SVI) of sludge at the experimental conditions.

Treatment of High Concentration Organic Wastewater with a Sequencing Batch Reactor (SBR) Process Combined with Electro-flotation as a Solids-liquid Separation Method

  • Choi, Younggyun;Park, Minjeong;Park, Mincheol;Kim, Sunghong
    • Environmental Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.395-399
    • /
    • 2014
  • Operation characteristics of the sequencing batch reactor (SBR) process with electro-flotation (EF) as a solid liquid separation method (EF-SBR) were investigated. EF-SBR process showed excellent solid-liquid separation performance which enabled to separate biosolids from liquid phase within 30 min and to extend cyclic reaction time. Although influent organic loading rate was increased stepwise from 5 to 15 g COD/day, food to microorganisms (F/M) ratio could be maintained about 0.3 g COD/g VSS/day in EF-SBR because biomass concentration could be easily controlled at desired level by EF. However, it was impossible to increase biomass concentration at the same level in control SBR (C-SBR) process because solid-liquid separation by gravity settling showed a limitation at higher mixed liquor suspended solids (MLSS) concentration with 60 min of settling time. Total chemical oxygen demand (TCOD) removal efficiency of EF-SBR process was not decreased although influent organic loading rate became 3 times higher than initial value. However, it was seriously deteriorated in C-SBR process after increasing the rate over 10 g COD/day, which was accounted for insufficient organic removal by relatively higher food to microorganisms (F/M) ratio as well as biosolids wash-out by a limitation of gravity sedimentation.

Multi-Phase Buck Converter with Fast Transient Response (빠른 응답을 갖는 멀티페이스 벅 변환기)

  • Lee, Yoon-Jae;Roh, Jeongjin
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.314-317
    • /
    • 2016
  • Recently, efforts to maximize battery life in progress with an increase in the demand for portable devices. In this paper, we propose multi-phase buck converter with fast transient response. Multi-phase buck converter may be used for the output capacitor of small size because the ripple cancellation effect, it is possible to use an inductor having an inductance less. The portable device for quick change from standby mode to active 4-phase design structure was given a fast transient response. The proposed multi-phase buck converter was fabricated using a 0.18 um CMOS process and the supply voltage ranges from 2.7V to 3.3V, the maximum load current is 500mA and settling time is 10us.