• Title/Summary/Keyword: settling efficiency

Search Result 171, Processing Time 0.023 seconds

Application of activated carbon induced ballasted flocculation for improving activated sludge settleability (활성슬러지 침전성 향상을 위한 활성탄 가중응집제 적용 연구)

  • Kim, Yongbum;Yang, Hyeji;Choi, Younggun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.153-162
    • /
    • 2021
  • The effects of activated carbon originated Ballasted Flocculant (BF) on the settleability of activated sludge and the recovery of BF by Hydro-cyclone (HC) were analyzed experimentally. Two kinds of BF (M-I: 125-250 ㎛, M-II: 250-425 ㎛ in dia.) and three kinds of activated sludges with different SS concentration (2,300-7,100 mg/L) were applied for this study. With the dosage variation of BF from 0.14 to 1.3 g-BF/g-SS, we could obtain 24-31% improvement in SV30 (Sludge Volume after 30min sedimentation) for the lowest SS concentration sludge (2,300 mg/L). Whereas the SV30 improvement was much higher as 44-48% for the highest SS concentration sludge (7,100 mg/L). The settling characteristics of the sludge with BF followed Vesilind model the best among three models (Vesilind, Takacs and Cho model). HC could effectively separate BF with the separation efficiency of 70-90% and over 95% separation efficiency could be obtained when the HC was applied twice.

The evaluation of T-P removal and dewaterability under the operation change in KIDEA process (-기술정보- 연속유입 KIDEA에서 공정변화에 따른 인제거 및 탈수 함수율 상관관계)

  • Yeon, seung jun;Her, hee seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.179-182
    • /
    • 2008
  • The KIDEA process, occurred in single reactor, is operated by three consequential steps, i.e., aerobic, settling, and discharge while introducing wastewater into the bottom of reactor continuously. It could accomplish biological oxidation (BOD), nitrification, denitrification (T-N), phosphate removal (T-P), and solid separation (SS) through the operational mode mentioned. Especially, this system has removed the T-P by wasting certain amount of sludge at the end of aeration phase during 5~10 minutes and not returned the activated sludge into the reactor, that is, no RAS (Return Activated Sludge). All running mode and instrumentation were controlled by the PLC equipment automatically. In this study, therefore, we have evaluated T-P removal efficiency and moisture content (MC) performance under the different excess sludge wasting mode. T-P track study and MC with TS concentration were analyzed during aerobic and settling phase. It has revealed that there was no significant difference of released T-P concentration between the first case which waste the sludge at the end of aerobic phase (0.2mg/L) and the second case which waste the sludge at 40 min of settling phase (0.25mg/L). Also, dewatering duration and MC have decreased 1.7% when TS concentration was increased from 0.31% to 0.5% during aerobic condition. Hence, it has concluded the system performance was less influenced by the operation time change of PLC program.

Evaluation of Hydraulic Characteristics Influenced by Different Deflector Baffles in the Sedimentation Basin with Inclined Plate Settler (경사판 침전지에서 저류벽의 설치위치에 따른 수리학적 특성의 평가)

  • Yu, Myong-Jin;Kim, Hyun-Chul;Ryu, Seong-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Sedimentation is one of the most common and important units in conventional water treatment plant. Structure such as various baffle walls and inclined plate settler may be obstacles to the horizontal flow when it is poorly designed. Therefore, the effects of these structures on characteristics of hydraulic flow must be evaluated to improve the settling efficiency of the floc. The hydraulic characteristic of the two sedimentations at Y water treatment plant (YWTP), which have different deflector baffles inside the settling basin, were investigated by tracer (fluoride) test. The inclined plate settler installed inside settling basin caused an undesirable impact on horizontal flow and produced dead zone. Solid baffle wall under the plate settler could help to minimize the formation of density currents and flow short circuiting. NaF used as a tracer was recovered more than 90% at investigated all basins. Morill index ($t_{90}/t_{10}$), Modal index ($t_p/T-HRT$) and short-circuiting index ($[M-HRT-t_p]/M-HRT$) were determined from tracer test results performed at YWTP. Those indices ranged 2.95~3.02, 0.40~0.53 and 0.32~0.46, respectively.

A Study on the Application and Design Procedure of Multi-Purpose Wet Detention Ponds for Improving Water Quality - Case Study of NamAk New Town Development Area - (다목적 저류지의 수질개선을 위한 설계과정 및 적용에 관한 연구 - 남악 신도시 개발지를 대상으로 -)

  • Woo, Chang-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.1
    • /
    • pp.97-109
    • /
    • 2004
  • The disposal of stormwater is one of the major problems in urban water management. One method of reducing peak runoff rates and other detrimental impacts of stormwater is detention storage. Detention ponds as a water quality control alternatives have been investigated by a number of researchers. Recognizing multiple roles such as flood peak attenuation, pollution removal and aesthetic enhancement, the design and management of detentions ponds deserve more research. The purpose of this research is to establish design criteria wet detention ponds to improve water quality. Water quality in detention pond discharge might be improve with physical, chemical and biological alterations. Physical alteration was focused in this study. There are several methods for estimating the suspended solid control capability of wet detention ponds. Existing models of suspended solids removal are based on sedimentation and gravity settling theory. The pollutant trap efficiency of pond is a function of several interrelating factors. Detention time is the most important factor, because it determine gravity settling quantities of pollutants. Desirable modification of physical factors for improvement of water quality in wet detention ponds are volume ratio, area ratio, length to width ratio, depth, out let location, bottom soil type. In order to apply design procedure in actual site, Namak new town development area was selected.

The Effect of Sludge Settleability on the Performance of DNR Process (슬러지 침전성이 DNR 공정에 미치는 영향 평가)

  • Suhl, Chang-Won;Lan, Thi Nguyen;Jeong, Hyeong-Seok;Lee, Sang-Min;Lee, Eui-Sin;Shin, Hang-Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.273-280
    • /
    • 2006
  • The sludge settleability is a key factor for operating activated sludge process as well as BNR (biological nutrient removal) process, because the poor sludge settling causes an increase of suspended solid in the effluent. In order to improving the sludge settleability, a settling agent such as iron dust can be applied. In this study, the effect of sludge settleability on the performance of DNR (Daewoo nutrient removal) process was investigated with GPS-X, which is the popular wastewater treatment process model program, and the result of modeling was verified with operating lab-scale DNR process. As a result, if the sludge blanket keeps stable in the secondary settling tank, the effluent quality is similar in spite of different SVI values. And in case of the good sludge settleability, short HRT or long SRT increased the biomass concentration in the bioreactor, and improved the pollutant removal efficiency. In spite of daily influent changing, the good sludge settleability also guaranteed the stable effluent quality. And the results of the lab-scale DNR process experiment could support the simulated results.

An aerobic granular sludge process for treating low carbon/nitrogen ratio sewage

  • Yae, JaeBin;Ryu, JaeHoon;Tuyen, Nguyen Van;Kim, HyunGu;Hong, SeongWan;Ahn, DaeHee
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.238-245
    • /
    • 2019
  • This study investigated the characteristic of aerobic granular sludge (AGS) process to treat the sewage having low carbon/nitrogen ratio (Biochemical oxygen demand ($BOD_5$):Total nitrogen (T-N), 4.5:1) in sequencing batch reactor (SBR). The removal efficiency of $BOD_5$, suspended solid (SS), T-N and phosphorus ($PO_4{^{3-}}$-P) were 92.6%, 64.3% and 90.1%. Concentration and size of AGS were changed in proportion to the organic matters and nitrogen concentration of the influent (Concentration and size of AGS: 1,700-3,000 mg/L, 0.5-1.0 mm). Mixed liquor suspended solid (MLSS) also changed with the concentration of AGS (MLSS: 2,000-3,500 mg/L). When the settling time was shortened from 15 min to 10 min, size and shape of AGS were maintained (Size of AGS: 1.0-1.5 mm). In addition, the concentration of AGS and MLSS increased (Concentration of AGS: 3,500 mg/L, MLSS: 4,000 mg/L). Concentration, size and shape of AGS were affected the settling time of the reactor more than the concentration of organic matter and nitrogen in the influent. In the results of removal efficiency and changes in AGS, we confirmed that the SBR process using AGS can be used to treat the sewage having low carbon/nitrogen ratio by applying short settling time.

A Study of Collision Characteristics in differential sedimentation according to variation of Ionic Strength, Zeta Potential and Particle Size (이온화세기, 제타전위, 입자크기에 따른 속도차 침전에서의 입자간 충돌특성에 관한 연구)

  • Han, Moo Young;Dock Ko, Seok;Park, Chung Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.1
    • /
    • pp.81-87
    • /
    • 1998
  • The possibility of collision of two particles slowly settling one after another in water can be described using the collision efficiency factor in differential sedimentation (${\alpha}_{DS}$). ${\alpha}_{DS}$ was found to be a function of several parameters particle size, particle size ratio, Hamaker constant, density of liquid and particle, gravity acceleration. Previous researches were limited to the case when there is no electric repulsion assuming that the suspension is destabilized. In this paper, ${\alpha}_{DS}$ is calculated for the stabilized condition. The relative trajectory of two particles are calculated including hydrodynamics, attraction and repulsion forces. Ionic strength and surface potential significantly affect the collision possibility of two settling particles. Depending on the surface potential and ionic strength, ${\alpha}_{DS}$ value is divided into three regions; stable, unstable and transition zone. ${\alpha}_{DS}$ increases as the ionic strength increases, and as the surface charge decreases. This result can be used to model both destabilized and stabilized suspension incorporating the collision efficiency factors of the other coagulant mechanisms such as fluid shear and Browian motion.

  • PDF

Treatment of Hydrogen Fluoride Generated from the F-gases Decomposition Processes

  • Park, Jun-Hyeong;Choi, Chang Yong;Kim, Tae-Hun;Shin, InHwan;Son, Youn-Suk
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.4
    • /
    • pp.190-196
    • /
    • 2016
  • The objective of this study is to obtain the optimal conditions to remove hydrogen fluoride (HF) generated from a variety of F-gas treatment processes. First, we selected $Ca(OH)_2$ and $CaCO_3$ as a reactant among the various alkali salts which have a high removal efficiency and a competitive price by forming a calcium fluoride precipitate. Additionally, various factors were investigated to improve the removal efficiency of HF. The conditions such as the settling time, agitating time and intensity, reaction temperature, and pH were considered as main factors. As a result, in the treatment process to remove HF through Ca-based alkali salts, the optimal conditions were a 120 min settling time, 30 min of agitation at 100 rpm, a pH of 4-8, and a reaction temperature of $40^{\circ}C$.

Preparation and Properties of Mixed Solvent Type Low Toxic Concentrated Oil Dispersant on Oil (혼합 용매계 저독성 농축형 유분산제의 제조와 광유에 대한 분산효율 특성)

  • Yeom, Kuy-Seol;Kang, Doo-Whan;Kim, Won-Ki
    • Journal of the Korean Applied Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.29-38
    • /
    • 1997
  • Low toxic concentrated oil dispersant using n-Paraffin and Di(ethylene glycol)mono butylether mixed solvent was prepared, and tested by oil dispersant performance test method, and oil dispersant efficiency was measured using vertical shaking method to 3 kinds of Crude oil, Bunker oil and W/O emulsions with different physical properties by appling the prepared dispersant. Although toxicity test was performed with Flat fish and Rock fish by appling the mixed oils emulsified using prepared oil dispersant, couldn't find the toxicity to them. Concentrated oil dispersant prepared has a good dispersion efficiency of 97.2% after 0.5min settling time and 28.3% after 10min settling time to Bunker B oil with 10% water solution. Especially, the concentrated oil dispersant showing the low toxicity to Oryzias Latipes(24hr, TLm) was 54,000 ppm and to Brine Shrimp Artemia(24hr, TLm) was 51,000ppm, and also, it was completely biodegradated to 99.1% after $7{\sim}8$days.

A Study on the Hydraulic Experiments of Modi Khola Hydroelectric in Nepal (네팔 Modi Khola 수력발전소 수리모형실험 연구)

  • 선우중호;박창근
    • Water for future
    • /
    • v.28 no.1
    • /
    • pp.107-120
    • /
    • 1995
  • This study is concerned with the hydraulic experiments of Modi Khola Hydroelectric in Nepal. The experimental domain consists of the intake structure and the settling basin. The intake structure was made by the undistorted model with the scale of 1:20, the settling basin by the distorted model with the scale of 1:10(vertical) and 1:15(horizontal). Based on the movable bed model theory, the 'Anthracite'($\rho_s$ =1.48) is chosen as a model material. According to the model tests, the installation of the guide wall with proper height and the proper control of the flushing gate are required for the effective flushing in the intake structure. In the settling basin a more proper design of the inlet in order to constrain the turbulence flow is required for an efficient sedimentation and the installation of another flushing pipe near the maximum sedimental area is required. Since the trap efficiency is measured about 95%, it is concluded that the design of the settling basin is proper.

  • PDF