• Title/Summary/Keyword: service water system

Search Result 442, Processing Time 0.029 seconds

Web-based Information System Construction of Animal Manure Matching Service for Recycling Agriculture (경축순환농업을 위한 가축분뇨 자원화 웹기반 정보은행 구축)

  • Ryoo, Jong-Won;Choi, Deog-Cheon
    • Korean Journal of Organic Agriculture
    • /
    • v.21 no.1
    • /
    • pp.1-18
    • /
    • 2013
  • Animal and crop production systems were integrated on a single farm. This integrated farming system recycled nutrients on the farm. The separation of animal and crop production with the introduction of cheap commercial fertilizers, farms were not used land-applied manure. The on-line manure matching is one of the emerging business in the achievement of recycling and resource recovery. The manure matching actively promotes the reuse and recycling of by-products and manure. This study constructs to manure matching information system to solve the exchange problems between herders and croppers. Manure matching web sites designed. This paper introduces a web-based animal manure matching system. A manure matching service, part of the manure transport, links farmers who produce excess manure with farmers who can use the manure. Farmers registered with the service have requested manure. The manure matching service supports the transport project by linking farmers with excess manure with those farmers who can utilize the manure safely as a nutrient source. The goal of the service is to protect water quality by fostering efficient land application. Benefits to those who use the manure network include reduced disposal costs, lower purchase costs and recycling of manure. The manure matching is based on the principle that 'one persons waste is another person's fertilizer.' It provides a free online matchmaking service for environmentally safe manure recycling management system.

Study on water pollution measurement and integration monitoring system with B-TOX (B-TOX를 이용한 오염수 측정 및 통합관리시스템 구현에 관한 연구)

  • Yang, Jae-Soo;Han, Yong-Hwan;Lee, Young-Ha;Kim, Yoon-Hyun;Kim, Jing-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.61-67
    • /
    • 2010
  • In operating estimation system, the river and lake is almost simple monitoring system or independent monitoring system. But the present system has many weak points about the concurrent analysis ability of various information collection. Sensors generating the information is not accurate. Therefore, we have something that can be improved. Although we have the related facilities of the purification plant, forebays and sewage disposal plant, and suffer from the difficulty about lack of system of estimation, management and control. As a result of this paper, monitoring system can observe the water pollution and various water environment of whole country. Also, through the sensors of USN, Zigbee, RFID and middle ware, which can service and construct service platform, we present standard plan of remarkable scalability service platform.

A Study on the Operating Performance of Solar Assisted Hot Water System for Apartment Houses (공동주택용 태양열원 급탕시스템의 운전성능 연구)

  • 이윤규;황인주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.928-936
    • /
    • 2003
  • In the present study, feasibility investigation on the solar assisted hot water supply system for apartment houses was carried out by the review of service facility and heat load pattern. Also analysis and experiment of the small sized system model were performed. This hybrid system are consists of solar collector, heat storage tank, controller, and gas boiler using LPG as a secondary heat source. The analytical results showed a good agreement with experimental data. We found that this hybrid system could reduce the energy cost by 30% for hot water compared to typical boiler system in the apartment houses. Also we showed that this model could be used for the energy and economic analysis of the hybrid system.

A Numerical Study on the Reduction of Water Hammering in a Simple Water Supply Pipe System

  • Lim, Ki-Won;Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.51-61
    • /
    • 2001
  • A numerical study has been conducted to characterize the transient pressure in a simple water supply pipe system with an air chamber by utilizing a commercial code that employs the method of characteristics. Some results produced for validation in the study agree quite well with the previously reported. Several parameters are than varied. Among them are the valve closure time, the wave speed, the static pressure, the polytropic exponent, the air chamber volume, the diameter and the shape of orifice in the air chamber, etc, while the water temperature and velocity are kept constant at $20^\circ{C}$ and 0.8m/s, respectively. Results reported in this parametric study may be useful to understand the unsteady behavior of the system.

  • PDF

A Study on the Rational Planning of Water Supply and Sewage System for Rural Village Development Projects (농촌마을종합개발사업에서 상하수도시설의 합리적 계획방향에 관한 기초적 연구)

  • Kim, Hwan-Yong
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.8 no.2
    • /
    • pp.62-71
    • /
    • 2006
  • This study on the rational planning of water supply and sewage system for rural village development projects. Present, when establishment and standard about maintenance of water supply and sewage system were not presented in rural village synthesis development projects, it is real condition that service industry is depending on presenting simple plan in basis planning phase and business enforcement step. This study wishes to present basic data so that can be planned more rationally and enforce and contribute in rural village synthesis development projects water supply and sewage system that is enforced as part of rural village synthesis development projects.

  • PDF

EXPERIMENTAL AND ANALYTICAL STUDIES ON THE INSTABILITY IN THE LZCS FOR CANDU REACTORS

  • Ji, Joon-Suk;Lee, Kwang-Ho;Yun, Bum-Su;Cha, Jung-Hun;Kim, Sang-Nyung
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.561-570
    • /
    • 2008
  • When reactivity insertion such as refueling occurs in CANDU reactors, the power and the water levels are tilted in the upper outer zone of the LZCS (Liquid Zone Control System) and fluctuate unstably for a certain period of time (1-5 days). The instability described above is observed in most CANDU reactors in service around the world, but its root cause is unidentified and no solutions to this problem have been established. Therefore, this study attempted to prove experimentally and analytically that the root cause lies in the hold-up of light water on the top of the TSP (Tube Support Plate) due to the mismatch between net volumetric flow rate of light water and helium crossing the narrowed porous TSP installed within the LZCS compartment. Our method was to perform a hydrodynamic simulation of in/outflow of light water and helium. Two solutions for the aforementioned instability of LZCS are suggested. One is to regulate the compartment for both inflowing helium gas and outflowing light water; the other is to enlarge the flow paths of helium and light water within TSP. The former may be applicable to nuclear reactors in service and the latter to those planned for construction.

Design criteria of Hazen-Williams C value of water pipe system (상수관로의 유속계수 설계기준)

  • Kwon, Hyuk Jae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.6
    • /
    • pp.659-666
    • /
    • 2015
  • In this study, Hazen-Williams C value of pipes in wide waterworks system was estimated and statistically analyzed. Hazen-Williams C value of water pipe was predicted after 20 years of service period. From the results, it was found that C value of water pipe for treated water maintained higher value of 110 after 20 years of installation. Furthermore, it was found that velocity coefficients of steel pipe for less than and more than 20 years of installation were 117.7 and 109.3, respectively. C value of ductile iron pipe for less than and more than 20 years of installation were 118.1 and 114.2, respectively. In this study, it was also found that small value of C is used in the design of water pipe system. Therefore, excessively bigger size of pipe can be determined in the design of water pipe system. From the results of present study, optimum value of C can be used to avoid the oversized design of water pipe system.

The Modernization of Automatic Control facilities of Hydro Power Plant (수력발전소 자동제어설비의 현대화)

  • Kwon, O-Geuk;Kwon, Young-June;Song, Young-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.69-70
    • /
    • 2008
  • Automatic control systems(AVR, Governor, Synchronizer) installed $1970{\sim}1980$ in K-water were considered to be rehabilitated around 2000. Moreover, Korea Power Exchange market system was changed from PPA (Power Purchase Agreement) to a bidding system. Therefore, depending on the power quality, the power provider could achieve additional profits. It is the excitation system and governor that have the functions of enhancing power necessities. During the 20 to 30 years of generator operation, there were many major and minor problems. Examples are SCR burnout (Andong: Excitation system), hunting (Imha: governor), field circuit breaker failure (Chungju 1st: excitation system), the rise of leakage current (Chungju 2nd: excitation system), power supply burnout (Chungju 2nd: governor). These are the typical examples of malfunction which hindered the generator operation and, consequently, diminished the profit of power business. In order to satisfy the needs of the power market and prevent malfunctions mentioned above, the rehabilitation of AVRs and governors were executed. A new system was made to have the flexibility of ancillary service (GF, AGC, etc.), PSS function. With user friendly HMI software, it is more convenient for the operator to fulfill suitable maintenance. It was possible to connect SCADA system by opening protocol of AVR, governor for the efficiency of operation and maintenance.

  • PDF

Modeling and Application of Chlorine Bulk Decay in Drinking Water Distribution System (배급수계통에서 잔류염소 감소 특성 및 적용연구)

  • Ahn, Jae-Chan;Park, Chang-Min;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.487-496
    • /
    • 2005
  • Chlorine bulk decay tests were carried out by bottle test under controlled conditions in a laboratory. Experiments were performed at different temperatures: $5^{\circ}C$, $15^{\circ}C$, $25^{\circ}C$, and the water temperatures when samples were taken from the effluent just before entering to its distribution system. 38 bulk tests were performed for water of Al (water treatment plant), 4 bulk tests for A2 (large service reservoir), and A3(pumping station). Residual chlorine concentrations in the amber bottles were measured over time till about 100 hours and bulk decay coefficients were evaluated by assuming first-order, parallel first-order, second-order. and $n^{th}-order$ reaction. The $n^{th}-order$ coefficients were obtained using Fourth-order Runge-Kutta Method. A good-fit by the average coefficient of determination ($R^2$) was first-order ($R^2=0.90$) < parallel first-order ($R^2{_{fast}}=0.92$, $R^2{_{slow}}=0.95$) < second-order ($R^2=0.95$) < $n^{th}-order$ ($R^2=0.99$). But if fast reaction of parallel first-order bulk decay were applied to the effluent of large service reservoir with ca. 20 hours of travel time and slow reaction in the water distribution system following the first 20 hours, parallel first-order bulk decay would be best and easy for application of water quality modeling technique.

Analysis of soil coarse pore fraction by major factors for evaluation of water conservation function potential in forest soil (산림토양의 수원함양기능 잠재력 평가를 위한 주요 인자별 토양 조공극률 분석)

  • Li, Qiwen;Lim, Hong-Geun;Moon, Hae-Won;Nam, Soo-Youn;Kim, Jae-Hoon;Choi, Hyung-Tae
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.6
    • /
    • pp.35-50
    • /
    • 2022
  • As the water shortage has become a noticeable issue due to climate change, forests play an importance role as the provider of water supply service. There is, however, little information about the relationships between the factors used in the estimation of water supply service and coarse pore fraction of forest soil which determines the potential of water supply. To find out whether there would be an amelioration in the scoring system of water supply service estimation, we examined all factors except meteorological one and additionally, analyzed 4 extra factors that might be related with coarse pore fraction of soil. A total of 2,214 soil samples were collected throughout South Korea to measure coarse pore fractions from 2015 to 2020. First, the result of average coarse pore fraction of all samples showed 32.98±6.59% which was consistent with previous studies. And the results of non-parametric analysis of variance indicated that only two of eleven factors that was used in the scoring system matched the results of coarse pore fraction of forest soils. Tree canopy coverage showed no difference among categories, and slope also showed no significance at level of 0.05 in the linear regression analysis. Additionally, the applicability of 4 extra factors were confirmed, as the result of coarse pore fractions of soil samples were different for various categories of each factor. Therefore, the scoring system of water supply service of forest should be revised to improve accuracy.