• Title/Summary/Keyword: series of buildings

Search Result 252, Processing Time 0.024 seconds

BIM Based Time-series Cost Model for Building Projects: Focusing on Construction Material Prices (BIM 기반의 설계단계 원가예측 시계열모델 -자재가격을 중심으로-)

  • Hwang, Sung-Joo;Park, Moon-Seo;Lee, Hyun-Soo;Kim, Hyun-Soo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.2
    • /
    • pp.111-120
    • /
    • 2011
  • High-rise buildings have recently increased over the residential, commercial and office facilities, thus an understanding of construction cost for high-rise building projects has been a fundamental issue due to enormous construction cost as well as unpredictable market conditions and fluctuations in the rate of inflation by long-term construction periods of high-rise projects. Especially, recent violent fluctuations of construction material prices add to problems in construction cost forecasting. This research, therefore, develops a time-series model with the Box-Jenkins methodologies and material prices time-series data in Korea in order to forecast future trends of unit prices of required materials. BIM (Building Information Modeling) approaches are also used to analyze injection time of construction resources and to conduct quantity takeoff so that total material price can be forecasted. Comparative analysis of Predictability of tentative ARIMA (Autoregressive Integrated Moving Average) models was conducted to determine optimal time-series model for forecasting future price trends. Proposed BIM based time series forecasting model can help to deal with sudden changes in economic conditions by estimating future material prices.

Ambient Vibration Testing and System Identification for Tall Buildings (고층건물의 자연 진동실험 및 시스템판별)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.23-33
    • /
    • 2012
  • Dynamic response measurements from natural excitation were carried out for three 18-story office buildings to determine their inherent properties. The beam-column frame system was adopted as a typical structural form, but a core wall was added to resist the lateral force more effectively, resulting in a mixed configuration. To extract modal parameters such as natural frequencies, mode shapes and damping ratios from a series of vibration records at each floor, the most advanced operational system identification methods based on frequency- and time-domain like FDD, pLSCF and SSI were applied. Extracted frequencies and mode shapes from the different identification methods showed a greater consistency for three buildings, however the three lower frequencies extracted were 1.2 to 1.7 times as stiff as those obtained using the initial FE models. Comparing the extracted fundamental periods with those estimated from the code equations and FE analysis, the FE analysis results showed the most flexible behavior, and the most simple equation that considers the building height as the only parameter correlated fairly well with test results. It is recognized that such a discrepancy arises from the fact that the present tests exclude the stiffness decreasing factors like concrete cracking, while the FE models ignore the stiffness increasing factors, such as the contribution of non-structural elements and the actual material properties used.

Calibration of model parameters for the cyclic response of end-plate beam-to-column steel-concrete composite joints

  • Nogueiro, Pedro;da Silva, Luis Simoes;Bento, Rita;Simoes, Rui
    • Steel and Composite Structures
    • /
    • v.9 no.1
    • /
    • pp.39-58
    • /
    • 2009
  • Composite joints, considering the composite action of steel and concrete, exhibit, in general, high strength and high ductility. As a consequence, the use of this type of joint has been increasing in many countries, especially in those that are located in earthquake-prone regions. In this paper, a hysteretic model with pinching is presented that is able to reproduce the cyclic response of steel and composite joints. Secondly, the computer implementation and adaptation of the model in a spring element within the computer code Seismosoft is described. The model is subsequently calibrated using a series of experimental test results for composite joints subjected to cyclic loading. Finally, typical parameters for the various joint configurations are proposed.

Design and Performance Evaluation of Hybrid Window Walls With Variable Transmittal Materials (투과시스템의 광학특성을 고려한 복합적 외벽채광부의 성능평가에 관한 연구)

  • Do, Jin-Seok;Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.11-18
    • /
    • 2004
  • Growing use of entire glass facades with metal frames are popularly witnessed in modern building practices and design competition as well. In spite of architectural aesthetics and view to outdoors, environmental issues still exist in that kind of buildings. One of the solutions for the problems might be the use of functional glasses such as a heat-resistant glass or various tinted glasses for the glass walls. This paper aims to provide performance data related to the impact of various transmittal materials of window systems on the light distribution. A series of computer simulation deals with the basic geometrical and optical design elements of a commonly used all-glass facades. Additionally an experimental configuration of the vertical window is proposed for better result of daylighting. A window system equipped with an inner-light shelf can improve the uniformity of natural light in a space by reducing the level of illumination near the window and redirecting light deeply into the space.

A parametric study on seismic fragility analysis of RC buildings

  • Nagashree, B.K.;Ravi, Kumar C.M.;Venkat, Reddy D.
    • Earthquakes and Structures
    • /
    • v.10 no.3
    • /
    • pp.629-643
    • /
    • 2016
  • Among all the natural disasters, earthquakes are the most destructive calamities since they cause a plenty of injuries and economic losses leaving behind a series of signs of panic. The present study highlights the moment-curvature relationships for the structural elements such as beam and column elements and Non-Linear Static Pushover Analysis of RC frame structures since it is a very simplified procedure of non-linear static analysis. The highly popular model namely Mander's model and Kent and Park model are considered and then, seismic risk evaluation of RC building has been conducted using SAP 2000 version 17 treating uncertainty in strength as a parameter. From the obtained capacity and demand curves, the performance level of the structure has been defined. The seismic fragility curves were developed for the variations in the material strength and damage state threshold are calculated. Also the comparison of experimental and analytical results has been conducted.

Shaking Table Tests of 1/12-Sale R.C. Bearing-Wall system with Bottom Piloti Frames (1/12 축소 철근콘크리트 상부벽식-하부골조 건축물의 진동대 실험)

  • 이한선;고동우;권기현;김병현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.407-414
    • /
    • 2001
  • The severe shortage of the available sites in the highly developed downtown area in Korea necessitates the construction of high-rise buildings which meet the need of residence and commercial activity simultaneously. The objective of this study is to investigate the seismic performance of this type of building structures. For this purpose, two 1 :12 scale 17-story reinforced concrete model structures were constructed according to the similitude law, in which the upper 15 stories have a bearing-wall system while the lower 2-story frames have two different layouts of the plan The one is a moment-resisting frame system and the other is a moment-resisting frame system with a infilled shear wall. Then, this model was subjected to a series of earthquake excitations. The test results show that the existence of shear wall reduced the shear deformation at the piloti frame, but has almost the negligible effect on the reduction of the overturning-moment angle.

  • PDF

Influence of wind disturbance on smart stiffness identification of building structure using limited micro-tremor observation

  • Koyama, Ryuji;Fujita, Kohei;Takewaki, Izuru
    • Structural Engineering and Mechanics
    • /
    • v.56 no.2
    • /
    • pp.293-315
    • /
    • 2015
  • While most of researches on system identification of building structures are aimed at finding modal parameters first and identifying the corresponding physical parameters by using the transformation in terms of transfer functions and cross spectra, etc., direct physical parameter system identification methods have been proposed recently. Due to the problem of signal/noise (SN) ratios, the previous methods are restricted mostly to earthquake records or forced vibration data. In this paper, a theoretical investigation is performed on the influence of wind disturbances on stiffness identification of building structures using micro-tremor at limited floors. It is concluded that the influence of wind disturbances on stiffness identification of building structures using micro-tremor at limited floors is restricted in case of using time-series data for low-rise buildings and does not cause serious problems.

Effects of damping ratio on dynamic increase factor in progressive collapse

  • Mashhadi, Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • v.22 no.3
    • /
    • pp.677-690
    • /
    • 2016
  • In this paper, the effect of damping ratio on nonlinear dynamic analysis response and dynamic increase factor (DIF) in nonlinear static analysis of structures against column removal are investigated and a modified empirical DIF is presented. To this end, series of low and mid-rise moment frame structures with different span lengths and number of storeys are designed and the effect of damping ratio in DIF is investigated, performing several nonlinear static and dynamic analyses. For each damping ratio, a nonlinear dynamic analysis and a step by step nonlinear static analysis are carried out and the modified empirical DIF formulas are derived. The results of the analysis reveal that DIF is decreased with increasing damping ratio. Finally, an empirical formula is recommended that relates to damping ratio. Therefore, the new modified DIF can be used with nonlinear static analysis instead of nonlinear dynamic analysis to assess the progressive collapse potential of moment frame buildings with different damping ratios.

Virtual Manufacturing for an Automotive Company (II) - Constuction and Operation of a Virtual Body Shop (자동차 가상생산 기술 적용 (II) - 차체공장 가상플랜트 구축 및 운영)

  • Noh, Sang-Do;Hong, Sung-Won;Kim, Duk-Young;Sohn, Chang-Young;Hahn, Hyung-Sang
    • IE interfaces
    • /
    • v.14 no.2
    • /
    • pp.127-133
    • /
    • 2001
  • Virtual Manufacturing is a technology facilitating effective development and agile production of products via computer models representing physical and logical schema and the behavior of the real manufacturing systems. For the successful application of this technology, a virtual plant as a well-designed and integrated environment is essential. We propose a series of systematic approaches and effective methods for construction and operation of a virtual plant in this paper, such as a 3-D CAD modeling, cell and line simulations and databases. We developed key technologies for measuring and 3-D CAD modeling of many equipments, facilities and structures of the buildings. In order to study the benefit of virtual manufacturing, we constructed a sophisticated virtual plant model of a Korean automotive company's body shop, and conducted precise simulations of unit cell, lines and the whole plant. We could obtain the benefit of savings in time and cost in many manufacturing preparation activities in the new car development processes.

  • PDF

Seismic performance of secondary systems housed in isolated and non-isolated building

  • Kumar, Pardeep;Petwal, Sandeep
    • Earthquakes and Structures
    • /
    • v.16 no.4
    • /
    • pp.401-413
    • /
    • 2019
  • The concept of base isolation for equipment is well known. Its application in buildings and structures is rather challenging. Introduction of horizontal flexibility at the base helps in proper energy dissipation at the base level thus reducing the seismic demand of the super structure to be considered during design. The present study shows the results of a series of numerical simulation studies on seismic responses of secondary system (SS) housed in non-isolated and base-isolated primary structures (PS) including equipment-structure interactions. For this study the primary structure consists of two similar single bay three-store reinforced cement concrete (RCC) Frame building, one non-isolated with conventional foundation and another base isolated with Lead plug bearings (LPB) constructed at IIT Guwahati, while the secondary system is modeled as a steel frame. Time period of the base isolated building is higher than the fixed building. Due to the presence of isolator, Acceleration response is significantly reduced in both (X and Y) direction of Building. It have been found that when compared to fixed base building, the base isolated building gives better performance in high seismic prone areas.