• Title/Summary/Keyword: series

Search Result 23,782, Processing Time 0.049 seconds

Study on ZnO Nanoparticle Dispersions in Test Media Including Natural Organic Matter for Ecotoxicological Assessment (천연유기물을 포함한 산화아연 나노입자 분산배지의 생태독성평가 적용성 연구)

  • Park, Sun-Young;Kim, Kyung-tae;Shin, Yu-jin;Kim, Ji-eun;Lee, Jae-woo;Jo, Eunhye;Sung, Hwa kyung;Kim, Pil-je;Choi, Kyung-hee;Eom, Ig-chun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.11
    • /
    • pp.634-640
    • /
    • 2017
  • Toxicity and fate assessment is necessary in the evaluation of the environmental, health and safety risks of engineered nanomaaterials (ENMs). Therefore, in order to ensure the reproducibility, reliability and relevance of ENMs toxicity results, stable and monomodal dispersion protocols in toxicity test media are needed. Zinc oxide nanoparticles (nZnO) are widely used in various products such as cosmetic products, paper, paints etc. In this study, nZnO dispersions in ecotoxicity test media were produced by following a series of steps of modified National Institute of Standards and Technology (NIST) Special publication 1200-5. In addition, natural organic matter (humic acid (HA)) was used as a stabilizing agent to disperse nZnO in the test media. The hydrodynamic diameters (HDD) of the nZnO in dispersion ranged between 150 and 200 nm according to the dynamic light scattering (DLS) measurement. Based on these dispersions in ecotoxicity test using ecological species (Oryzias latipes, Daphnia magna, Pseudokirchneriella subcapitata and Chironomusus riparius), dispersion protocol was found to have a considerable potential in ecotoxicity test of ENMs.

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

Detection of Sea-water Intrusion Caused by Tidal Action Using DC Resistivity Monitoring (전기비저항 모니터링을 이용한 해수침투 파악)

  • Hwang, Hak-Soo;Lee, Sang-Kyu;Ko, Dong-Chan;Kim, Yang-Soo;Park, In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • The 1 $km^2$ area studied is located in Sukchun-ri, Hwasung-koon, the southern part of Kyeonggi-do. Even though this site has been known as a contaminated area caused by seawater intrusions, geophysical and geochemical surveys have never been carried out at the site to determine the extent of the seawater contamination and to investigate whether the seawater intrusion is in progress. The purpose of this study is to determine the extent of seawater contamination and a preferred channel of the seawater intrusion using geophysical methods such as DC resistivity surveys with Schlumberger array and a dipole-dipole array. In order to determine whether the seawater intrusion is in progress in the area, DC resistivity monitoring with Schlumberger array was performed. According to the resistivity map obtained from the inversion of the resistivity data measured with Schlumberger array, the study area is divided into two districts as relatively lowly resistive (less than 30 ohm-m) and highly resistive (more than 30 ohm-m) areas. The distribution of the lowly resistive area is consistent with the distribution of the layer composed of clay minerals, and the resistivity of this layer decreases slowly as approaching to the old seashore. Hydrogeological analysis shows that the clay layer within a distance of about 200 m from the seashore has been already contaminated by sea-water and its electric conductivity is 8 times higher than that of the sand layer covered by the clay layer. According to the results of the 2-dimensional DC resistivity surveys with a dipole-dipole array, there are two preferred channels of the seawater intrusion in the site, and both the channels are in the NW-SE direction from the old seashore. The lowly resistive zone in the southern channel extends to a depth of 80 m. The DC resistivity monitoring with Schlumberger array was carried out along the preferred channel which has the low resistivity Bone (fracture zone) that extended to a depth of 80 m. The time series of apparent resistivity, measured at a distance of 260 m from the old coast line, fluctuates with a period of 12 hours. From these observations, it can be concluded that the seawater intrusion caused by tidal action is still in progress along the fractured zone interpreted by the DC resistivity surveys with a dipole-dipole array.

  • PDF

A Study on the Psychopharmacological Actions of Panax ginseng in Animals (인삼의 향정신작용에 관한 연구)

  • Hong, Sa-Ack;Kim, Myeong-Seok;Jang, Hyeon-Gap
    • Journal of Ginseng Research
    • /
    • v.1 no.1
    • /
    • pp.33-50
    • /
    • 1976
  • As a continuation of series of works on the pharmacological actions of Panax ginseng. three kinds of behavioral experiments were carried out using rats and mice. The occurrence of component Posterns of general behavioral activity in rat was examined by visual scanning using the ting sample method in the ad lib. And he hunger deprivated situation. In normal ad lib. situation, the eating behavior of rat treated with 100mg/kg of ginseng saponin was significantly more frequent than that of saline control at the night and throughout the 24 hr period. But grooming was less frequent than the control at the same period. In the hunger situation followed by 90~120 hrs of feed deprivation, the locomotive activity and rearing awe significantly more often and sleeping was less frequent in the two dosage g roups of ginseng saponin (10 and 100 mg/kg) than in the saline group though out the observation period. Training of avoidance conditioning in rats was done in a two-way shuttle box. The number of conditioned response (CR) in which the animal avoided sucessfully an electric shock by running in to the other compartment of the hex was regarded as an index of learning performance. Ginseng saponin in doses of 2.5 mg/kg Produced a significantly increased CR in total avoidance tria1s compared with the control. Although other dosage groups of ginseng saponin (5.0, 50mg and 100 mg/kg) showed no significant statistical difference from the normal control, it tended to increase in CR in the ginseng groups than in the control. An aggressive behavior in mice was observed in n shock-generating fighting box. The occurrence of reflexive fighting between two animals induced by an electric shock applied to the feet war checked as an index of aggression. The occurrence of reciprocal fighting episode immediately after the onset. Of the shock was significantly decreased in the dosage group of 400 mg/kg ginseng saponin, but it did net differ in the 100 mg/kg group of ginseng saponin from the control group. The dose, 400 mg/kg of ginseng saponin, inhibited fighting behavior in more than 80% of the Pairs. but 100 mg/kg of ginseng did inhibit it in less than 20% of the pairs.

  • PDF

Registration and Description of Public Records in Korea : A Comparative Analysis of Korean Recordskeeping System with the International Standards (한국의 기록물 둥록 및 기술에 대한 기록관리적 접근)

  • Si, Kwi-Sun
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.3 no.1
    • /
    • pp.69-92
    • /
    • 2003
  • Registration and description of records are important elements of processing which provide with the background information of production of records and business-related information. They also enable to search and use the records. In this paper, I examined the Korean registration and description system defined in the Public Records Management Act which directs the records creating agency to register records in creating offices and directs the "professional archives" to make "basic registrations" and "detailed registrations" of the records. In the analysis and comparison of two different registration and description systems with the known international standards of records and archives management, such as ISO15489 and ISAD(G), I intended to evaluate the Korean records and archives management system and suggested recommendations for the renovation of the Korean recordskeeping system. Despite we have unique office business procedures and the culture of officialdom, and despite we have developed our system based on the established business procedures and office culture, it would be preferable to adopt or follow the international standards and established best practices. After the comparative analysis, I recommended some innovations in the filed of registration and description. For instance, in the basic registration. we would better to install an item of "simple contents summary." We may also need the multiple-level description. The fonds level description and the series level description should be introduced to our archival automated management system. We need to establish a Korean standard of description adopting the rules of the ISAD(G) and ISAAR(CPF). Essential requirements for electronic records management, such as contextual and structural information, should be incorporated in the new standard. Documentation of records disposition also should be reinforced to guarantee the authenticity of records and to ensure control of the records. To implement the recommendations for the standard, we need to amend the Public Records Management Act and its Regulations and Rules. Also it is imperative to redesign the GARS integrated archival automated management system.

The Procedure for Decision of Enforcement by the Arbitration Award and Its Problems (중재판정에 의한 집행판결의 절차와 그 문제점)

  • Kim Bong-Suk
    • Journal of Arbitration Studies
    • /
    • v.13 no.1
    • /
    • pp.169-205
    • /
    • 2003
  • Arbitration means the procedure that a party inquires a third party arbitrator for a resolution on the dispute on certain matters of interest to follow through with the commitment of the arbitration, and a series of procedures performed by the arbitrator of the Korean Commercial Arbitration Board. Arbitration is implemented in accordance with the procedure determined by the Arbitration Act and Arbitration Regulations. In the event the parties reach to the reconciliation during the process of arbitration, the reconciliation is recorded in the form of arbitration award(decision), and in the event a reconciliation is not made, the arbitrator shall make the decision on the particular case. The arbitration award(decision) for reconciliation during the arbitration procedure (Article 31 of Arbitration Act, hereinafter referred to as the 'Act') or the mediation under the Arbitration Regulation of the Korean Commercial Arbitration Board (Article 18 of the Arbitration Regulations) shall have the same effectiveness with the decision rendered by a court that, in the event a party does not perform the obligation, the enforcement document is rendered under the Rules on Enforcement Document on Mediation Statement of various dispute resolution committees of the Supreme Court to carry out the compulsory enforcement. However, in the event that the party to take on the obligation to perform under the arbitration award (decision) rendered by the arbitrator (Article 32 of the Act) does not perform without due cause, a separate enforcement decision in accordance with the procedure determined under the Civil Enforcement Act shall be obtained since the arbitration award(decision) cannot be the basis of enforcement under the Civil Enforcement Act. And, in order to enforce the judgment compulsorily in accordance with the regulations under the Civil Enforcement Act under the foreign arbitration judgment (Article 39 of the A.1), it shall fulfill the requirement determined under the Civil Litigation Act (article 217 of Civil Litigation Act) and shall obtain a separate enforcement decision in accordance with the procedure determined under the Civil Enforcement Act (Article 26 and Article 27 of Civil Enforcement Act) since the arbitration judgment of foreign country shall not be based on enforcement under the Civil Enforcement Act. It may be the issue of legislation not to recognize the arbitration award(decision) as a source of enforcement right, and provide the compulsive enforcement by recognizing it for enforcement right after obtaining the enforcement document with the decision of a court, however, not recognizing the arbitration award(decision) as the source of enforcement right is against Clause 3 of Article 31 of the Act, provisions of Article 35, Article 38 and Article 39 that recognized the validity of arbitration as equal to the final judgment of a court, and the definition that the enforcement decision of a court shall require the in compulsory enforcement under Clause 1 of Article 37 of the Act which clearly is a conflict of principle as well. Anyhow, in order to enforce the arbitration award(decision) mandatorily, the party shall bring the litigation of enforcement decision claim to the court, and the court shall deliberate with the same procedure with general civil cases under the Civil Litigation Act. During the deliberation, the party obligated under the arbitration award(decision) intended to not to undertake the obligation and delay it raises the claim and suspend the enforcement of cancelling the arbitration award(decision) on the applicable arbitration decision within 3 months from the date of receiving the authentic copy of the arbitration award(decision) or the date of receiving the authentic copy of correction, interpretation or additional decision under the Regulation of Article 34 of the Act (Clause 3 of Article 36 of the Act). This legislation to delay the sentencing of the enforcement and then to sentence the enforcement decision brings the difficulties to a party to litigation costs and time for compulsory enforcement where there is a requirement of an urgency. With the most of cases for arbitration being the special field to make the decision only with the specialized knowledge that the arbitrator shall be the specialists who have appropriate knowledge of the system and render the most reasonable and fair decision for the arbitration. However, going through the second review by a court would be most important, irreparable and serious factor to interfere with the activation of the arbitration system. The only way to activate the arbitration system that failed to secure the practicality due to such a factor, is to revise the Arbitration Act and Arbitration Regulations so that the arbitration decision shall have the right to enforce under the Rules on Enforcement Document on Mediation Statement of various dispute resolution committees of the Supreme Court.

  • PDF

Numerical Analysis of Unstable Combustion Flows in Normal Injection Supersonic Combustor with a Cavity (공동이 있는 수직 분사 초음속 연소기 내의 불안정 연소유동 해석)

  • Jeong-Yeol Choi;Vigor Yang
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.91-93
    • /
    • 2003
  • A comprehensive numerical study is carried out to investigate for the understanding of the flow evolution and flame development in a supersonic combustor with normal injection of ncumally injecting hydrogen in airsupersonic flows. The formulation treats the complete conservation equations of mass, momentum, energy, and species concentration for a multi-component chemically reacting system. For the numerical simulation of supersonic combustion, multi-species Navier-Stokes equations and detailed chemistry of H2-Air is considered. It also accommodates a finite-rate chemical kinetics mechanism of hydrogen-air combustion GRI-Mech. 2.11[1], which consists of nine species and twenty-five reaction steps. Turbulence closure is achieved by means of a k-two-equation model (2). The governing equations are spatially discretized using a finite-volume approach, and temporally integrated by means of a second-order accurate implicit scheme (3-5).The supersonic combustor consists of a flat channel of 10 cm height and a fuel-injection slit of 0.1 cm width located at 10 cm downstream of the inlet. A cavity of 5 cm height and 20 cm width is installed at 15 cm downstream of the injection slit. A total of 936160 grids are used for the main-combustor flow passage, and 159161 grids for the cavity. The grids are clustered in the flow direction near the fuel injector and cavity, as well as in the vertical direction near the bottom wall. The no-slip and adiabatic conditions are assumed throughout the entire wall boundary. As a specific example, the inflow Mach number is assumed to be 3, and the temperature and pressure are 600 K and 0.1 MPa, respectively. Gaseous hydrogen at a temperature of 151.5 K is injected normal to the wall from a choked injector.A series of calculations were carried out by varying the fuel injection pressure from 0.5 to 1.5MPa. This amounts to changing the fuel mass flow rate or the overall equivalence ratio for different operating regimes. Figure 1 shows the instantaneous temperature fields in the supersonic combustor at four different conditions. The dark blue region represents the hot burned gases. At the fuel injection pressure of 0.5 MPa, the flame is stably anchored, but the flow field exhibits a high-amplitude oscillation. At the fuel injection pressure of 1.0 MPa, the Mach reflection occurs ahead of the injector. The interaction between the incoming air and the injection flow becomes much more complex, and the fuel/air mixing is strongly enhanced. The Mach reflection oscillates and results in a strong fluctuation in the combustor wall pressure. At the fuel injection pressure of 1.5MPa, the flow inside the combustor becomes nearly choked and the Mach reflection is displaced forward. The leading shock wave moves slowly toward the inlet, and eventually causes the combustor-upstart due to the thermal choking. The cavity appears to play a secondary role in driving the flow unsteadiness, in spite of its influence on the fuel/air mixing and flame evolution. Further investigation is necessary on this issue. The present study features detailed resolution of the flow and flame dynamics in the combustor, which was not typically available in most of the previous works. In particular, the oscillatory flow characteristics are captured at a scale sufficient to identify the underlying physical mechanisms. Much of the flow unsteadiness is not related to the cavity, but rather to the intrinsic unsteadiness in the flowfield, as also shown experimentally by Ben-Yakar et al. [6], The interactions between the unsteady flow and flame evolution may cause a large excursion of flow oscillation. The work appears to be the first of its kind in the numerical study of combustion oscillations in a supersonic combustor, although a similar phenomenon was previously reported experimentally. A more comprehensive discussion will be given in the final paper presented at the colloquium.

  • PDF

Feasibility of Application of Roy's Adaptation Model to Family Health Assessment (로이적응모델의 가족건강사정에의 적용가능성)

  • Jang Sun-Ok
    • Journal of Korean Public Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.35-56
    • /
    • 1994
  • This article was intended to survey whether Roy' Adapation model ('Roy Model') can be applied to family health assessment and to study whether application of the Roy Model to a Korean family is feasible. under the Roy Model, a family is viewed as an adaptation system having a series of process of input. process, feedback, and output. Further, the Roy Model indicates that a family contains Physiolosical, self-concept. role function and interdependent mode in respect of internal or external stimuli. In the event where the family health assessed, the adaptation mode of that family must be assess at the first stage. Then, the focal, contextual, residual stimuli affecting the family must be assessed. In 1984 Hanson suggested four types of family adaptation mode based upon the Roy Model and thereby enhanced the possibility for family health assessment. In order survey whether the Roy Model can be applied to the Korean family, the author of this article contracted adults of 169 who live in 'A' city to make open questions regarding family and then analyzed responses from them by utilizing Roy model. This study categorized family Adaptation mode based upon the' four types of family adaptation mode developed by Hanson. As a result of this study, family adaptation mode was categorized into 117 concepts. Those 117 concepts are consisted or Physiolosical mode of 47. self­concept mode of 56, role function mode of 9 and interdependent mode of 5. Further. stimuli affecting family were classified based upon Roy's definition as to three types of stimuli. Stimuli on a family are comprised focal stimuli concept of 19, contextual stimuli concepts of 19, one residual stimuli concept. this result implies that the Roy's Model can be applied to Korean family. Physiological mode shows meaning of survival. while self-concept mode reflects meaning of growth and emphasizes harmony among the family based on the familism. The role function mode shows continuity rather control of family member. By contrast, interdependent mode shows interaction with community to which the family belongs. but the degree of interaction does not appear too high. The analysis of family stimuli led this study to conclude that troubles within a family. changes in family structure and diease of family member generate stimuli. However, an application of the Roy Model contains the following problems: First, Roy argued that the family adaptation mode should be assessed at the first level family health assessment and then stimuli affecting family adaptation should be adaptation assessed at the second stage. To the belief of the author of this article. however, for checking family adaptation level. focal, contextual, residual stimuli should be confirmed by assessing stimuli at first stage. Then, the family adaptation mode in respect of such stimuli should be assessed. The rationale for this is that the family adaptation level is determined depending on degree of strength of focal. contextual. residual stimuli. Second. Whall (1991) raised a question 'Does one assess family adaptation mode and intervene in the stimuli?' 'Likewise, assessment of the family adaptation should be made in the following manner in order for family health to be enhanced. Third. Roy believes that additional stimuli (such as contextual and residual) are same as internal process (including nurturance. support, and socialization). However, the basis for this Roy's belief is not too clear. In spite of these problems which the author indicated above, it can be concluded that the Roy Model can serve as a good device for an assessment of family health and that the Roy Model can be applied to a Korean family. Finally, further research of family adaptation theory and family nursing theory is required for a development of these theories.

  • PDF

A Study on the Characteristics of Tropical Cyclone Passage Frequency over the Western North Pacific using Empirical Orthogonal Function (경험적 직교함수를 이용한 북서태평양 열대저기압의 이동빈도 특성에 관한 연구)

  • Choi, Ki-Seon;Kang, Ki-Ryong;Kim, Do-Woo;Hwang, Ho-Seong;Lee, Sang-Ryong
    • Journal of the Korean earth science society
    • /
    • v.30 no.6
    • /
    • pp.721-733
    • /
    • 2009
  • A pattern of tropical cyclone (TC) movement in the western North Pacific area was studied using the empirical orthogonal function (EOF) and the best track data from 1951 to 2007. The independent variable used in this study was defined as the frequency of tropical cyclone passage in 5 by 5 degree grid. The $1^{st}$, $2^{nd}$ and $3^{rd}$ modes were the east-west, north-south and diagonal variation patterns. Based on the time series of each component, the signs of first and second mode changed in 1997 and 1991, respectively, which seems to be related to the fact that the passage frequency was higher in the South China Sea for 20 years before 1990s, and recent 20 years in the East Asian area. When the eigen vectors were negative values in the first and second modes and TC moves into the western North Pacific, TC was formed mainly at the east side relatively compared to the case of the positive eigen vectors. The first mode seems to relate to the pressure pattern at the south of Lake Baikal, the second mode the variation pattern around $30^{\circ}N$, and the third mode the pressure pattern around Japan. The first mode was also closely related to the ENSO and negatively related to the $Ni\tilde{n}o$-3.4 index in the correlation analysis with SST anomalies.

Fabrication and Performance of Anode-Supported Flat Tubular Solid Oxide Fuel Cell Unit Bundle (연료극 지지체식 평관형 고체산화물 연료전지 단위 번들의 제조 및 성능)

  • Lim, Tak-Hyoung;Kim, Gwan-Yeong;Park, Jae-Layng;Lee, Seung-Bok;Shin, Dong-Ryul;Song, Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.283-287
    • /
    • 2007
  • KIER has been developing the anode-supported flat tubular solid oxide fuel cell unit bundle for the intermediate temperature($700{\sim}800^{\circ}C$) operation. Anode-supported flat tubular cells have Ni/YSZ cermet anode support, 8 moi.% $Y_2O_3$ stabilized $ZrO_2(YSZ)$ thin electrolyte, and cathode multi-layer composed of Sr-doped $LaSrMnO_3(LSM)$, LSM-YSZ composite, and $LaSrCoFeO_3(LSCF)$. The prepared anode-supported flat tubular cell was joined with ferritic stainless steel cap by induction brazing process. Current collection for the cathode was achieved by winding Ag wire and $La_{0.6}Sr_{0.4}CoO_3(LSCo)$ paste, while current collection for the anode was achieved by using Ni wire and felt. For making stack, the prepared anode-supported flat tubular cells with effective electrode area of $90\;cm^2$ connected in series with 12 unit bundles, in which unit bundle consists of two cells connected in parallel. The performance of unit bundle in 3% humidified $H_2$ and air at $800^{\circ}C$ shows maximum power density of $0.39\;W/cm^2$ (@ 0.7V). Through these experiments, we obtained basic technology of the anode-supported flat tubular cell and established the proprietary concept of the anode-supported flat tubular cell unit bundle.