• Title/Summary/Keyword: serial system

Search Result 1,054, Processing Time 0.028 seconds

Design and Comparison of the Pipelined IFFT/FFT modules for IEEE 802.11a OFDM System (IEEE 802.11a OFDM System을 위한 파이프라인 구조 IFFT/FFT 모듈의 설계와 비교)

  • 이창훈;김주현;강봉순
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.570-576
    • /
    • 2004
  • In this paper, we design the IFFT/FFT (Inverse fast Fourier Transform/Fast Fourier Transform) modules for IEEE 802.11a-1999, which is a standard of the High-speed Wireless LAN using the OFDM (Orthogonal Frequency Division Multiplexing). The designed IFFT/FFT is the 64-point FFT to be compatible with IEEE 802.11a and the pipelined architecture which needs neither serial-to-parallel nor parallel-to-serial converter. We compare four types of IFFT/FFT modules for the hardware complexity and operation : R22SDF (Radix-2 Single-path Delay feedback), the R2SDF (Radix-2 Single-path Delay feedback), R2SDF (Radix-4 Single-path Delay Feedback), and R4SDC (Radix-4 Single-path Delay Commutator). In order to minimize the error, we design the IFFT/FFT module to operate with additional decimal parts after butterfly operation. In case of the R22SDF, the IFFT/FFT module has 44,747 gate counts excluding RAMs and the minimized error rate as compared with other types. And we know that the R22SDF has a small hardware structure as compared with other types.

Development of the Serial Data Transmission System for Pneumatic Valve System Control

  • Kim, Dong-Soo;Choi, Byung-Oh;Seo, Hyun-Seok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1152-1156
    • /
    • 2003
  • For pneumatic valve system control, we need a serial data transmission system with high speed and reliability for information interchange between main computer and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic valve system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid control valves. in addition, we developed a communication protocol for construction of rs-485 based multi-drop network and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. the field test results show that, even under high noise environment, the data transmission of 375kbps rate is possible up to 1,500meter without using repeater. In addition, the system developed in this research is easily to be extended for a communication network because of its modular structure.

  • PDF

Implementation of Data Protocol Conversion System for High-end CMOS Image Sensors Equipped with SMIA CCP2 Serial Interface (SMIA CCP2 직렬 인터페이스를 가지는 고기능 이미지 센서를 위한 데이터 프로토콜 변환 시스템의 구현)

  • Kim, Nam-Ho;Park, Hyun-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.753-758
    • /
    • 2009
  • Recently the high-end CMOS image sensors are developed, conforming to the SMIA CCP2 specification, which is a high-speed low-power serial interface based on LVDS technology. But this kind of technology trend makes the existing equipments are no longer useful, although their capability is still good enough to handle the recent image sensors if there was no interfacing problem. In this paper, we propose and realize a data protocol conversion system that translates the SMIA CCP2 serial signals into the existing 10-bit parallel signals. The proposed system is composed of a de-serializer and a FPCA chip, and thus can be constructed on a small PCB which enables easy integration between the existing equipments and the new high-end image sensors. Besides, the maximum transfer rate by the SMIA specification is also achieved on the implemented system. So it is expected that the implemented system can be used as a general-purpose protocol converter in a variety of sensor-related application fields.

Development of Test Equipment for KSLV-I Upper Stage (KSLV-I 상단부 시험장비(UTE) 설계 및 개발)

  • Kim, Kwang-Soo;Lee, Soo-Jin;Chung, Eui-Seung;Park, Jeong-Joo
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.171-179
    • /
    • 2007
  • The Test Equipment for the upper stage of KSLV-I has following functions via umbilical cable interface; external power supply, command output such as discrete and analog, data acquisition, CS-I interface simulation for first stage of KSLV-I and RS-422 serial communication for PDU. The main purpose of UTE is the experiment or function verification of system-level upper stage. To realize this system, we used PXI control system. The UTE is consisted of the PXI control system, power supply, terminal block, internal harness, connector panel and so on. The software functions of UTE are classified by four blocks. These are Discrete/Analog I/O control, PDU RS-422 serial communication control, power supply GPIB control and UTE remote control. In this paper, we will describe the design on the hardware and software of UTE.

  • PDF

A Comparative Study of the Security Prevention Strategies on Arson: Focused on the Behavioral Characteristics between Serial Arsonists and Simple Arsonists (방화범죄의 경비예방 전략에 관한 비교연구 - 연쇄방화범과 단순방화범의 행위적 특성을 중심으로 -)

  • You, Wan-Seok;Hwang, Sung-Hyun
    • Korean Security Journal
    • /
    • no.29
    • /
    • pp.139-162
    • /
    • 2011
  • The purpose of this study is to compare with the general and behavioral characteristics between simple and serial arsonists using the data derived from Scientific Crime Analysis System, Criminal Filing Search System, and Crime Information Management System. The analysis and findings reported here are derived from data extracted from 160 arsonists arrested by police officer. The independent variables included such socio-economic characteristic as arsonists' gender, age, occupation, education level, and previous criminal records of arsonists, and finally the general characteristics of the scene of fire settings. The dependent variable is whether or not serial fire setter. To achieve the purpose, the analysis of frequencies and cross-tab were conducted. According to frequence and cross-tab analysis, there are great differences of the general and behavior characteristics between two groups. In the comparison of simple and serial arsonists, serial arsonists are more likely to have previous criminal records, low socio-economic status, unmarried and no cohabitants than simple arsonists. furthermore, serial arsonists are more likely to use garbage papers for fire setting in the scene of the crime, to have mental or psychological problems, and to get involved in fire setting for the psychological pleasure than simple arsonists do. The present research has some obvious limitations. First, the analysis is based only on arsonists arrested by police officers. These may be considerable differences in arsonists arrested by police officers and fire setters not arrested by them. Additional research is needed to assess the extent to which these findings would apply to fire setters not arrested by police officer in Korea. Secondly, the data in this study are cross-sectional and simple cross-tab analysis are used. Potential limitation of cross-sectional data concerns the inability to specify the changes in measures as arsonists behavioral characteristics. Therefore, further studies need to use longitudinal data and more complicate statistical techniques such as correlation analysis, multiple regression analysis, or LISREL models to specify the casual relationships between dependent and independent variables for fire settings. Even if this study has some limitations, it is meaningful in which it first investigated the comparison of simple and serial arsonists focusing on the general and behavioral characteristics between two groups in Korea.

  • PDF

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

An Interrupt Coalescence Method for Improving Performance of Asynchronous Serial Communication (비동기 시리얼 통신의 성능 향상을 위한 인터럽트 통합 기법)

  • Park, Geun-Duk;Oh, Sam-Kweon;Kim, Byoung-Kuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1380-1386
    • /
    • 2011
  • The request of interrupt accompanies a context switching. If the interrupt is frequently requested, this overhead of context switching can reduce seriously the performance of embedded systems. In order to reduce processing overhead due to frequently requested communication interrupts at Asynchronous Serial Communication, this paper introduces the method of Expanded Asynchronous Serial Communication with the Interrupt Coalescence(IC) that accumulates a fixed number of interrupts and processes them in one time. we implement the existing Asynchronous Serial Communication that requests communication interrupts by one byte at an LN2440SBC embedded board with a uC/OS-II and compare interrupt processing time for the performance evaluation about proposed method. As a result, the communication interrupt processing time of proposed method appears in case of low speed(9,600 bps), the decline of an average 25.18% at transmission, the decline of an average 41.47% at reception. and in case of hight speed(115,200 bps), the decline of an average 16.67% at transmission, the decline of an average 25.61% at reception.

Modeling and Analysis of High Speed Serial Links (SerDes) for Hybrid Memory Cube Systems (하이브리드 메모리 큐브 (HMC) 시스템의 고속 직렬 링크 (SerDes)를 위한 모델링 및 성능 분석)

  • Jeon, Dong-Ik;Chung, Ki-Seok
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.12 no.4
    • /
    • pp.193-204
    • /
    • 2017
  • Various 3D-stacked DRAMs have been proposed to overcome the memory wall problem. Hybrid Memory Cube (HMC) is a true 3D-stacked DRAM with stacked DRAM layers on top of a logic layer. The logic die is mainly used to implement a memory controller for HMC, and it is connected through a high speed serial link called SerDes with a host that is either a processor or another HMC. In HMC, the serial link is crucial for both performance and power consumption. Therefore, it is important that the link is configured properly so that the required performance should be satisfied while the power consumption is minimized. In this paper, we propose a HMC system model included the high speed serial link to estimate performance accurately. Since the link modeling strictly follows the link flow control mechanism defined in the HMC spec, the actual HMC performance can be estimated accurately with respect to each link configuration. Various simulations are conducted in order to deduce the correlation between the HMC performance and the link configuration with regard to memory utilization. It is confirmed that there is a strong correlation between the achievable maximum performance of HMC and the link configuration in terms of both bandwidth and latency. Therefore, it is possible to find the best link configuration when the required HMC performance is known in advance, and finding the best configuration will lead to significant power saving while the performance requirement is satisfied.

A Study on protocol analysis between KTX control system and sub-devices (고속열차(KTX)제어시스템과 하부장치간 프로토콜 분석연구)

  • Kim, Hyeong-In;Jung, Sung-Youn;Kim, Hyun-Shik;Jung, Do-Won;Kim, Chi-Tae;Kim, Dong-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.179-186
    • /
    • 2007
  • KTX control systems mutually control OBCS, ATC, MBU, TECA, MDT, ABU, HVAC, TRAE, PID and FDTR, KTX OBCS as master, and controls other sub-control devices as slave, using various serial lines. In order to analyze physical structure of various serial link lines and mutual data transmission structure, serial line analyzer is used in many ways. To use serial line analyzer, prior and professional technics about High Speed Train and experience of using device are necessary. In spite of difficult situation of space and environment where we work for maintenance of High Speed Train, in presenting basic structure about physical connection method aquired by sub-device serial line data collection and about communication data analysis, I hope that this research will be helpful for the person who work for similar area. Also, I hope that this research will help diagnostic work of High Speed Train, which is necessary for test run of independently developed High Speed Train.

  • PDF

Design and Implementation of Wireless Lighting LED Controller using Modbus TCP for a Ship (Modbus TCP를 이용한 선박용 무선 LED 제어기의 설계 및 구현)

  • Jeong, Jeong-Soo;Lee, Sang-Bae
    • Journal of Navigation and Port Research
    • /
    • v.41 no.6
    • /
    • pp.395-400
    • /
    • 2017
  • As a serial communications protocol, Modbus has become a practically standard communication protocol and is now a commonly available means of connecting industrial electronic devices. Therefore, all devices can be connected using the Modbus protocol with the measurement and remote control on ships, buildings, trains, airplanes and more. The existing Modbus that has been used is based on serial communication. Modbus TCP uses Ethernet communication based on TCP / IP which is the most widely used Internet protocol today; so, it is faster than serial communication and can be connected to the Internet of Things. In this paper, we designed an algorithm to control LED lighting in a wireless Wi-Fi environment using the Modbus TCP communication protocol, and designed and implemented a LED controller circuit that can check external environmental factors and control remotely through the integrated management system of a ship. Temperature, humidity, current and illuminance values, which are external environmental factors, are received by the controller through the sensors, and these values are communicated to the ship's integrated management system via the Modbus protocol. The Modbus can be connected to Master devices via TCP communication to monitor temperature, humidity, current, illuminance status and LED output values, and also users can change the RGB value remotely in order to change to the desired color. In addition, in order to confirm the implementation of the controller, we developed a simulated ship management system to monitor the temperature, humidity, current and illumination conditions, and change the LED color of the controller by changing the RGB value remotely.