• 제목/요약/키워드: sequentially g-connected

검색결과 2건 처리시간 0.018초

ON SEQUENTIALLY g-CONNECTED COMPONENTS AND SEQUENTIALLY LOCALLY g-CONNECTEDNESS

  • Vijayashanthi, Palanichamy
    • Korean Journal of Mathematics
    • /
    • 제29권2호
    • /
    • pp.355-360
    • /
    • 2021
  • In this paper, we introduce the definition of sequentially g-connected components and sequentially locally g-connected by using sequentially g-closed sets. Moreover, we investigate some characterization of sequentially g-connected components and sequentially locally g-connected.

실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구 (A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation)

  • 이병설;최충석
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.