• 제목/요약/키워드: separation length

검색결과 450건 처리시간 0.031초

ECDIS에 의한 외끌이 기선저인망 어선의 투양망 조업 과정의 실시간 모니터링 (Real-time monitoring of net setting and hauling process in fishing operations of Danish seine vessel using ECDIS)

  • 이대재;변덕수
    • 수산해양기술연구
    • /
    • 제43권4호
    • /
    • pp.347-354
    • /
    • 2007
  • This paper describes on the real-time monitoring of net setting and hauling process for fishing operations of Danish seine vessels in the southern waters of Korea as an application of a PC based ECDIS system. Tracking of fishing process was performed for the large scale Danish seine vessel of G/T 90 and 350 PS class using the fishing gear which the length of net, ground rope, head rope and sweep line including warp in both sides were 86m, 104m, 118m and 3,200m, respectively. Tracking information for net setting and hauling process was continuously recorded for 23 fishing operations performed on November and December, 2003. All measurement data, such as trawl position, heading, towing course and past track which was individually time stamped during data acquisition, was processed in real time on the ECDIS and displayed simultaneously on the ENC chart. The results indicated that after the separation of a marker buoy from Danish seiner, the averaged running speed of vessel and the averaged setting period while shooting the seine on the course of diamond shape to surround the fish school in the 23 fishing operations were 8.3 knots and 13.1 minutes, respectively. And with the maker buoy taken on board, the averaged running speed of vessel and the averaged towing period while closing the seine on the straight route was 1.0 knots and 47.0 minutes, respectively. After the closing stage of hand rope, the hand rope was towed by the averaged speed of 2.2 knots during the 13.0 minutes. The average area for route of diamond shape swept by sweep lines of the seine in 23 fishing grounds was $709,951.6m^2$. Further investigation is also planed to provide more quantitative tracking information and to achieve more effective surveillance and control of Danish seine vessels in EEZ fishing grounds.

Dynamic Mechanical and Morphological Studies of Styrene-co-Methacrylate and Sulfonated Polystyrene Ionomers Containing Aliphatic Dicarboxylate Salts

  • Luqman, Mohammad;Kim, Joon-Seop;Shin, Kwan-Woo
    • Macromolecular Research
    • /
    • 제17권9호
    • /
    • pp.658-665
    • /
    • 2009
  • This study examined the effects of the sodium salts of aliphatic dicarboxylic acids (DCAs) on the dynamic mechanical properties and morphology of two sets of poly(styrene-co-sodium methacrylate) (MNa) and poly(styrene-co-sodium styrenesulfonate) (SNa) ionomers. When the DCA content was relatively low, the ionic moduli of the MNa and SNa ionomers increased but the matrix and cluster glass transition temperature ($T_g$) did not change significantly. The increasing ionic modulus was almost independent of the type of the ionic groups of the ionomer, and the chain length of DCAs. When a large amount of the sodium succinate (DCA4) was added to the MNa and SNa ionomers, the ionic moduli of the two ionomers increased strongly but the matrix and cluster $T_g's$ increased slightly and significantly, respectively. In the case of sodium hexadecanedioate (DCA 16), DCA 16 increased the ionic moduli of the two ionomers. The addition of DCA16 changed the matrix and cluster $T_g's$ of the MNa ionomer slightly, but decreased the cluster $T_g$ of the SNa ionomer significantly with no change in the matrix $T_g$. In addition, the DCA-containing ionomers showed an X-ray diffraction peak indicating the presence of ordered domains of DC As in the ionomers. Hence, DCA4 acts mainly as a reinforcing filler in MNa and SNa systems. In the case of DCA 16, it initially behaved like a filler but also functioned as a preferential plasticizer for the clusters at high content.

Determination of Non-Steroidal Anti-Inflammatory Drugs in Human Urine Sample using HPLC/UV and Three Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME)

  • Cha, Yong Byoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3444-3450
    • /
    • 2013
  • Three phase hollow fiber-liquid phase microextraction (HF-LPME), which is faster, simpler and uses a more environmentally friendly sample-preparation technique, was developed for the analysis of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) in human urine. For the effective simultaneous extraction/concentration of NSAIDs by three phase HF-LPME, parameters (such as extraction organic solvent, pH of donor/acceptor phase, stirring speed, salting-out effect, sample temperature, and extraction time) which influence the extraction efficiency were optimized. NSAIDs were extracted and concentrated from 4 mL of aqueous solution at pH 3 (donor phase) into dihexyl ether immobilized in the wall pores of a porous hollow fiber, and then extracted into the acceptor phase at pH 13 located in the lumen of the hollow fiber. After the extraction, 5 ${\mu}L$ of the acceptor phase was directly injected into the HPLC/UV system. Simultaneous chromatographic separation of seven NSAIDs was achieved on an Eclipse XDB-C18 (4.6 mm i.d. ${\times}$ 150 mm length, 5 ${\mu}m$ particle size) column using isocratic elution with 0.1% formic acid and methanol (30:70) at a HPLC-UV/Vis system. Under optimized conditions (extraction solvent, dihexyl ether; $pH_{donor}$, 3; $pH_{acceptor}$, 13; stirring speed, 1500 rpm; NaCl salt, 10%; sample temperature, $60^{\circ}C$; and extraction time, 45 min), enrichment factors (EF) were between 59 and 260. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of 5-15 ng/mL and 15-45 ng/mL, respectively. The relative recovery and precision obtained were between 58 and 136% and below 15.7% RSD, respectively. The calibration curve was linear within the range of 0.015-0.96 ng/mL with the square of the correlation coefficient being more than 0.997. The established method can be used to analyse of NSAIDs of low concentration (ng/mL) in urine.

휴대용 기체 크로마토그래피 / 광이온화 검출기 시스템의 개발 (Development of Portable Gas Chromatography / Photoionization Detector System)

  • 김만구;심지희;이동수;이용근
    • 대한화학회지
    • /
    • 제38권2호
    • /
    • pp.151-159
    • /
    • 1994
  • 기체시료 채취기와 짧은 모세관 컬럼(내경 0.32 mm, 길이 3 m), 광이온화 검출기 및 진공펌프로 구성되어, 컬럼의 출구 압력이 대기압보다 낮은 압력에서 조작되는 휴대용 기체 크로마토그래피 시스템을 개발하였다. 컬럼의 규격은 Golay식을 이용한 계산 결과를 기초로 선택하였으며, 조작압력비(컬럼입구와 출구압력비)는 1.03~1.2의 범위가 적절하였고, 이 조건에서 0.87∼4.63 ml/min의 걸럼유량을 얻을 수 있었다. 구경이 다른 3개의 튜브로 구성된 기체시료 채취기는 자동으로 기체시료를 직접 컬럼에 빠른 속도로 반복하여 도입할 수 있으며, 좋은 재현성을 나타내었다. 컬럼출구 압력이 대기압 이하에서 조작되며 짧은 모세관 컬럼을 사용하는 기체 크로마토그래피는 최적 컬럼유량이 일반적인 크로마토그래피보다 커 신속한 분석이 가능하여, 40초 이내에 m-xylene 과 o-xylene의 바탕선 분리가 가능하였다. 시스템의 분리능력에 영향을 주는 인자는 시료 채취시간, 컬럼의 길이와 내경 및 조작압력비였고, 벤젠 유도체들을 사용하여 이들의 영향을 검토하였다.

  • PDF

PSG 광도파박막을 이용한 $1.3/1.55\mum$ WDM coupler의 설계 및 제작 (Design and fabrication of the $1.3/1.55\mum$ WDM coupler with the PSG waveguide films)

  • 전영윤;김한수;이용태;이형종
    • 한국광학회지
    • /
    • 제6권4호
    • /
    • pp.310-316
    • /
    • 1995
  • 유한영역에서의 조화함수전개법으로 인접한 두 도파로 코어 중심간의 거리 및 도파로 변수에 따른 결합길이를 계산하여 $1.3/1.55\mum$ WDM coupler을 설계하였다. 저압화학기상증착법에 의해 PSG 도파박막을 제작하고 laser lithography와 $CF_4/O_2$ RIE 공정 등을 이용하여 WDM coupler를 제작하였다. 또한 광섬유를 지지 및 고정하기 위하여 Si 기판 위에 V-groove를 만들었으며 제작된 WDM coupler와 V-groove로 지지된 광섬유를 UV curing epoxy를 사용하여 접속하였다. 제작된 WDM coupler의 $1.3.\mum$, $1.55\mum$에서의 분지별 도파모드를 관측하고 분할비를 측정한 결과 최대 분할비는 각각 9dB, 12dB였다.

  • PDF

이동통신 시스템에서 입력 메시지 분리제어 방식을 통한 제어국의 성능 개선 (Performance Improvement of Base Station Controller using Separation Control Method of Input Messages for Mobile Communication Systems)

  • 원종권;박우구;이상호
    • 한국정보처리학회논문지
    • /
    • 제6권4호
    • /
    • pp.1058-1070
    • /
    • 1999
  • 이 논문은 이동통신 시스템의 제어국에 순간적으로 가해지는 다량의 입력 메시지에 대하여 효율적이고 신뢰성 있는 제어를 위하여 입력 메시지를 메시지 특성에 따라 분리한 다음 다중 프로세서를 사용하여 제어하는 모델을 제안한다. 제안 모델의 성능 개선에 필요한 요소들의 특성을 사전에 파악하기 위하여 M/M/c/K 큐잉 모델을 이용한다. 이 결과를 토대로 SLAM II를 이용한 시뮬레이션에 의해 입력 메시지에 대한 손실확률, 큐의 평균점유 길이의 분포, 프로세서 관리기(서버)의 점유율, 큐에서의 평균 대기 시간에 대하여 제안 모델과 기존 모델의 성능을 비교한다. 또한 과도한 입력 메시지로 인하여 과부하가 발생할 경우 두 입력 메시지에 대한 부하 제어 기능을 추가한 모델을 제안하고, 시뮬레이션에 의해 성능을 분석한다.

  • PDF

한국산 기름종개 Cobitis taenia Linne의 연구 3. 횡반B${\cdot}$C형의 형태와 분포 (A STUDY OF KOREAN SPINOUS LOACHES(Cobitis taenia Linne) 3. On the Morphology and Distribution of the Crossband B-type and C-type)

  • 김익수
    • 한국수산과학회지
    • /
    • 제9권3호
    • /
    • pp.209-213
    • /
    • 1976
  • 여러가지 반문형을 가진 기름종개는 우리나라의 어디에나 널리 분포하지만 횡반B형과횡반 C형은 영산강과 섬진강에서만 서식하고 있어 주목된다. 이 2형은 반문과 지리적 분포상 차이를 보이면서도 이들의 체장분포, 아가미뚜껑뒤의 친한 흑갈색의 반점, 골질반의 구조, 비늘의 형태는 동일하다. 그러나 반문, 2차성징, 체장분포 및 비늘의 형태상 특징은 본속 기지종과는 분명희 구별된다. 이것은 지리적 격리에 의하여 생긴 고유한 형태로서 원래 동일종 이었던 것이 오랜 세월이 지남에 따라 한때 연결되었으리라고 추측되는 영산강과 섬진강이 각각 독립되므로 양개체군간에 교배가 불가능하기 때문에 반문의 분화가 생긴 것으로 본다.

  • PDF

열 장 흐름 분획장치의 제작과 효율성에 관한 연구 (A Study of Construction and Efficacy of Thermal Field-Flow Fractionation)

  • 이대운;허욱환;전선주;이인호
    • 대한화학회지
    • /
    • 제36권3호
    • /
    • pp.419-427
    • /
    • 1992
  • 본 연구에서는 열 장 흐름 분획장치를 제작하고 이를 이용하여 폴리스티렌의 머무름과 선택성을 조사하였으며 최적 분리조건을 결정하였다. 열 장 흐름 분획장치의 채널 부분은 열전도도가 좋은 구리판을 윗벽과 아랫벽으로 하여 그 사이에 Mylar spacer를 끼워 제작하였다. 구리판 표면은 이상적인 유선형 흐름이 이루어지도록 매끈하고 굴곡이 없도록 세공하였으며, Mylar spacer는 채널을 형성하도록 잘라낸 후 거친 부분을 사포로 갈아내었다. 윗 구리판은 히터를 넣어 온도를 높였고 아래 구리판은 수도물을 이용하여 온도를 낮추어 온도 구배를 주었다. 폴리스티렌의 머무름은 분자량과 채널에 가해준 온도차가 커지면 증가하였고, 일정한 온도차에서 차가운 벽의 온도를 20∼$45^{\circ}C$로 높히면 감소하였다. 시료의 선택성은 크기 배제 크로마토그래피보다 훨씬 좋았으며, 머무름이 큰 용질일수록 선택성이 좋았다. 이론단의 높이는 유속과 비례하였으며, 이로부터 폴리스티렌의 다분산도를 측정할 수 있었다.

  • PDF

소아 외래마취의 특성 (Pediatric Outpatient Anesthesia)

  • 서일숙
    • Journal of Yeungnam Medical Science
    • /
    • 제18권2호
    • /
    • pp.145-169
    • /
    • 2001
  • 수술전, 후의 준비 및 처치를 적절히 할 수만 있다면 수술을 받은 후 귀가하는 외래수술은 특히 소아환자와 보호자로부터 환영받을 수 있는 안전하고 경제적인 방법이다. 대상환아의 선택시에는 수술의 종류와 소요시간 그리고 환아의 상태 등을 종합적으로 판단하여 수술후 합병증을 야기하지 않고, 빠른 회복이 가능한 대상을 선별토록 해야 하며 특히 소아의 연령에 따른 인지의 정도 및 심리적 다양성을 충분히 감안하여 마취유도시 까지는 정신외상을 주지 않도록 환아와의 rapport형성에 최대한의 배려를 해야 하며 수술후의 통증 및 회복시 야기될수 있는 부작용에 대하여는 가능한 한 예방이 바람직하나 초래된 경우에는 신속한 처치를 해주므로써 환아의 고통을 경감시켜 주도록 해야한다. 최근에 등장한 여러가지 이상적인 마취약제들과 아울러 합리적인 투여방법의 발달로 신속하고 부드러운 마취유도 및 수술이 끝난 후의 빠른 회복 그리고 부작용의 최소화가 가능하게 되었다. 그러나 국내의 의료현실상 아직은 이상적인 약제들을 의사의 판단에 따라 자유롭게 사용할 수 있는 여건이 되지 못하며 소아의 통증치료에 대하며 의료전이 소극적이며 수술후 관리에 대한 보호자들의 이해수준이 낮으므로 수술 당일 바로 환아를 병원에서 퇴원시키는 것은 상당한 위험성을 내포하고 있기 때문에 소아에서의 외래마취는 성인의 경우와는 달리 아직은 보편화되지 못하고 있는 실정이다.

  • PDF

가로세로비에 따른 날개 하부 유동장의 공기역학적 영향 (Aerodynamic Effect on the Flow Field under the Wing with Varying Aspect Ratio)

  • 조철영;박종호
    • 한국추진공학회지
    • /
    • 제20권2호
    • /
    • pp.94-101
    • /
    • 2016
  • 본 논문에서는 날개의 가로세로비 변화가 날개 하부 유동장에 미치는 공기역학적 영향을 압력분포 측정과 입자영상속도계(PIV)를 이용하여 조사하였다. PIV 측정결과를 이용하여 파일런 주변 유동장의 속도변화를 레이놀즈수 $1.384{\times}10^5$$2.306{\times}10^5$의 조건에서 속도 성분별로 각각 분석하였다. 파일런으로부터 날개의 끝단이 시위 길이의 80% 만큼 떨어진 가로세로비 4.8의 경우, 날개 끝단으로부터의 끝단 와류의 영향이 날개 아랫면의 표면압력을 낮아지게 하고, 날개 끝단 주변의 흐름을 가속시킴으로써 날개 하부의 파일런 주변 유동장에 영향을 미쳤다. 시험결과에서는 가로세로비가 증가함에 따라 날개 하부 유동장에 대한 날개 끝단으로부터의 공기역학적 효과는 작아지는 경향을 보였다.