• Title/Summary/Keyword: separation distance

Search Result 536, Processing Time 0.031 seconds

Breast Radiotherapy with Mixed Energy Photons; a Model for Optimal Beam Weighting

  • Birgani, Mohammadjavad Tahmasebi;Fatahiasl, Jafar;Hosseini, Seyed Mohammad;Bagheri, Ali;Behrooz, Mohammad Ali;Zabiehzadeh, Mansour;meskani, Reza;Gomari, Maryam Talaei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7785-7788
    • /
    • 2015
  • Utilization of high energy photons (>10MV) with an optimal weight using a mixed energy technique is a practical way to generate a homogenous dose distribution while maintaining adequate target coverage in intact breast radiotherapy. This study represents a model for estimation of this optimal weight for day to day clinical usage. For this purpose, treatment planning computed tomography scans of thirty-three consecutive early stage breast cancer patients following breast conservation surgery were analyzed. After delineation of the breast clinical target volume (CTV) and placing opposed wedge paired isocenteric tangential portals, dosimeteric calculations were conducted and dose volume histograms (DVHs) were generated, first with pure 6MV photons and then these calculations were repeated ten times with incorporating 18MV photons (ten percent increase in weight per step) in each individual patient. For each calculation two indexes including maximum dose in the breast CTV ($D_{max}$) and the volume of CTV which covered with 95% Isodose line ($V_{CTV,95%IDL}$) were measured according to the DVH data and then normalized values were plotted in a graph. The optimal weight of 18MV photons was defined as the intersection point of $D_{max}$ and $V_{CTV,95%IDL}$ graphs. For creating a model to predict this optimal weight multiple linear regression analysis was used based on some of the breast and tangential field parameters. The best fitting model for prediction of 18MV photons optimal weight in breast radiotherapy using mixed energy technique, incorporated chest wall separation plus central lung distance (Adjusted R2=0.776). In conclusion, this study represents a model for the estimation of optimal beam weighting in breast radiotherapy using mixed photon energy technique for routine day to day clinical usage.

Investigation of the Variation of SAR Values in Mice and Rats Depending on the Exposure Conditions in Whole-Body Exposure Environments (전신 노출 환경에서 노출 조건에 따른 마우스와 랫트의 SAR 값 변화량 분석)

  • Mun, Ji-Yeon;Seo, Min-Gyeong;Kim, Tae-Hong;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.2
    • /
    • pp.161-167
    • /
    • 2013
  • In animal experiments for EMF exposure, it is very important to estimate the SAR values accurately in animals. In this paper, we investigated the variation of SAR values in mice and rats, depending on the number and separation distance of animals and the existence of the water-supplying bottle. The whole-body of mice or rats in a cage were exposed in the reverberation chamber at CDMA and WCDMA frequencies. Simulation results show that the variation of the whole-body averaged SAR is larger when several animals are exposed in a cage, compared to the existence of water-supplying bottle and the amount of water. It turns out that compared to single mouse or rat is located in the cage, the maximum variation of the whole-body averaged SAR values for mice at 850 MHz and 1,950 MHz are 15.3 % and 14.9 % when three mice are located in the cage, and those for rats are 18.7 % and 21.1 % for each frequency when two rats are located in the cage. It is concluded that the variation of SAR values depending on the exposure conditions in real situation cannot be ignored.

LPG Cylinder Leak Experiment from Multiple Leak Scenarios (누출종류에 따른 LP가스용기 누출량 실증 실험)

  • Lee, Minkyung;Lee, Kang-Ok;Kim, Young Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.61-66
    • /
    • 2019
  • Unlike NG supplied through pipes, LPG is mainly used for independent storage of cylinders or small storage tanks. As LPG is widely used in islands and underdeveloped areas, accidents due to neglect of safety management are high. Houses and businesses that have LPG accidents are likely to be damaged due to relatively high population density. Therefore, the necessity of strengthening the safety management of LPG is constantly raised. Accordingly, in 1996, Korea Gas Safety Corporation conducted an LPG leak test. In this study, based on the 96-year experiment, the gas leakage measurement of LPG vessels was conducted by adding several conditions such as outside temperature and pipe condition. Through this, the trend of leakage for various scenarios of LPG leakage was examined. In the case of a gas leak, when the article which may affect the pressure such as a regulator is not connected, the leakage amount is greatly changed by the outside air temperature, and when the regulator is fastened, the influence of the outlet pressure is large. It is expected that the experiment can be used as basic data for determining gas accidents and leakages that may occur later.

A Study on the Image Evaluation for the Improvement of the Landscape of Horticultural Complex in Rural Area (농촌지역 시설원예단지의 경관 개선을 위한 이미지평가)

  • Kong, Minjae;Lee, Siyoung;Kang, Donghyeon;Park, Minjung;Yun, Sungwook;Shin, Jihoon;Son, Jinkwan
    • Journal of Bio-Environment Control
    • /
    • v.26 no.2
    • /
    • pp.78-86
    • /
    • 2017
  • Humans are provided with a wide range of public benefits from ecosystems and agricultural ecosystems, but the establishment of the horticulture complex could be a space that hampers the public function of the agricultural ecosystem. In this study, we sought to focus the function of landscape creation of agricultural landscape and tried to analyze the landscape of the horticulture complex. Therefore, This study aims to suggest ways to build a greenhouse complex which is being indiscreetly introduced in the agriculture landscape through environmentally-friendly manner and minimize the function of the ecosystem service. We divided the greenhouse complex into two categories of Plastic Greenhouse(v) and Glass Greenhouse(g), and compared them to the Netherland and Japan counterparts. Each image of research areas was selected by 3 pics and polled by a total of 101 people. The results of the Evaluation of Landscape Image are as shown in the figure. Netherland Glass Greenhouse scored 1.80 in terms of 'Neat' which is one of the given 15 adjectives. Study results shows that Korean Plastic Greenhouse landscapes need to endeavor Japanese vinly greenhouses and Dutch glasshouses. Consequently, an analysis on the elements of landscapes including green area, variant elements, separation distance is essential in order to improve our country's greenhouse complex landscapes. In this regard, continuous research is required to improve rural landscapes and harmonize large-scale horticultural facilities into the existing agricultural ecosystem.

Population Genetic Structure of Octopus minor Sasaki from Korea and China Based on a Partial Sequencing of Mitochondrial 16S rRNA (미토콘드리아 16S rRNA 염기서열에 의한 한국, 중국 낙지의 유전자 집단 분석)

  • Kim, Joo-Il;Oh, Taeg-Yun;Seo, Young-Il;Cho, Eun-Seob
    • Journal of Life Science
    • /
    • v.19 no.6
    • /
    • pp.711-719
    • /
    • 2009
  • We determined a portion of mitochondrial 16S rRNA gene sequences (416 bp) to investigate the genetic structure of the octopus (Octopus minor Ssaki) population in Korea and China. Samples were obtained from Korea (Yeosu, Namhae, Jindo, Muan, Geomundo and Seosan) and China (Sandong) during the period of August 2006 to September 2007. Sequence analyses of 28 individual specimens collected from 7 localities revealed 11 haplotypes, ranging in a sequence divergence of 0.2% - 1.2%. Phylogenetic analyses using PHYLIP and networks subdivided the octopus into two clades (termed clade A and B) and the nucleotide divergence between them was 0.4%. This haplotype subdivision was in accordance with geographic separation: one at Yeosu, Namhae, Muan and Jindo, and the other at Seosan, Geomundo and Sandong. On the basis of hierarchial genetic analysis, genetic distance between localities in Korea and China were also found, but a significant population differentiation was not shown in this study (p>0.05). Consequently, most of the octopus populations in Korea had considerable distribution due to the mitochondrial gene flow that resulted in a formation of a genetically homogenous structure, whereas some of the Korean and Chinese populations had different genetic structures. Gene flow among populations may be restricted due to impassable geographic barriers that promote genetic differentiation.

A Study on the Improving Speech Intelligibility of Emergency Broadcast Equipment in the Apartments (공동주택 내 비상방송설비의 음성명료도 실태 분석 및 재실자 인지성 개선방안 연구)

  • Oh, So-Young;Cho, Hyun-Min;Lee, Young-Ju;Lee, Min-Joo;Yoon, Myung-Oh
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.60-68
    • /
    • 2018
  • Due to the complicated plan structure of the apartment units and the improved room-to-room sound insulation performance, it is difficult to communicate and recognize the fire situation by emergency broadcast equipment. In this study, speech intelligibility was measured and analyzed for three types of apartment unit by emergency broadcast equipment on various measurement points. Simulations were also conducted to improve the speech intelligibility. As a result of field measurements 72, 84, and 101 Type were not satisfied with NFSC standard of 90 dBA at the point of 1 m distance from source. In addition, it was evaluated that 75 dBA and CIS 0.7 of NFPA standard was not satisfied at all measurement points except for the 72 Type at living room point with door opened condition. Based on the door opened condition of the bedroom, it satisfied the NFPA of 75 dBA and CIS 0.7 in each bedroom when more than 90 dBA was satisfied at the 1 m separation point provided in NFSC standard.

An Advanced MCL Method for a Sharing Analysis of Mobile Communication Systems beyond 3G (차세대 이동통신 시스템의 주파수 공유분석을 위한 개선된 MCL 방법)

  • Chung Woo-Ghee;Yoon Hyun-Goo;Jo Han-Shin;Lim Jae-Woo;Yook Jong-Gwan;Park Han-Kyu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.307-316
    • /
    • 2006
  • In this paper the analytical method, namely advanced minimum coupling loss(A-MCL), was proposed in order to analyze the coexistence of OFDM-based systems beyond 3G(B3G) with point-to point(PP) fixed service(FS) microwave systems. Our proposed method is based on a power spectral density(PSD) analysis. So it can be easily applicable to analyze the coexistence of OFDM-based systems B3G using flexible spectrum usage(FSU) with other systems, where the conventional MCL method cannot allocate transmit power partially to some subcarriers which overlap the band of a victim system. By applying the conventional MCL method and the A-MCL method, interfering power levels at the receiver of a interfered system are respectively calculated. A-MCL can calculate interference power more accurately than MCL by the maximum value of 4.5 dB. Therefore it can be concluded that our prosed method, namely A-MCL, is applicable to a sharing analysis of OFDM-based systems B3G.

Performance Enhancement Study of a Final Clarifier by the Optimum Design of Inlet and Baffle Condition (유입구 및 정류벽 최적설계에 의한 최종 침전지 성능 개선 연구)

  • Kim, Hey-Suk;Shin, Mi-Soo;Jang, Dong-Soon;Jung, Sung-Hee;Gang, Dong-Hyo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.177-183
    • /
    • 2005
  • The effluent quality is directly affected by the separation of biological solids in a final clarifier because the majority of discharged $BOD_5$ and SS are virtually dependent on the results of biological solids in the sedimentation tank effluent. If a final clarifier is effectively designed and operated, the desired goal of clarification for wastewater can be achieved together with the cost reduction in the treatment of wastewater. To this end flow characteristics and the removal efficiency of SS are numerically investigated especially by the change of the inlet position and the installation of baffle to improve the performance of a rectangular final clarifier. The 2-D computer program developed in a rectangular coordinates has been successfully validated against experimental residence time distribution(RTD) curves obtained by tracing radio-isotope. The lowering of the inlet position weakens the density current and induces the settling of SS in the front zone of a clarifier. Thus the decreased traveling distance of the sludge increases the removal efficiency of SS in the effluent. The inlet baffle installed in the front region of clarifier prevents the short circuiting flow and induces to flow into the dense underflow, which eventually improves the effluent quality. In the case of lower inlet position, however, installation of baffle results in degradation of effluent quality. Consequently it is strongly recommended that in-depth numerical study be performed in advance for optimizing a clarifier design and retrofitting to improve effluent quality in a final clarifier.

Underwater Channel Environment Analysis Using 10Khz Carrier Frequency at the Shore of West Sea (10kHz 반송파를 사용한 서해안 수중 채널환경 분석)

  • Kim, Min-sang;Ko, Hak-lim;Kim, Kye-won;Lee, Tae-seok;Im, Tae-ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.1
    • /
    • pp.132-139
    • /
    • 2016
  • This study was carried out near the waters of Jango port, Dangjin-gun, Chungcheongnam-do by utilizing 10kHz carrier frequency, for the purpose of measurement and analysis of underwater channel environment of the Western sea. For the measurement of horizontal channel environment, the separation distance between transmitter and receiver is made differently in the range between 10m and 4000m. Meanwhile, for the measurement of vertical channel environment, transmission and receiving side ships are fixed as contacted each other and measured differently depending on their depth of submergence. In this study, the Coherence Bandwidth and the Coherence Time were estimated by analyzing the Power delay profile of the real sea based on the measured data, and analyzing the doppler frequency through frequency conversion of received tone-signal, respectively. This study is expected to become a base study in carrying out the frame design for underwater communication to improve the communication and secure the reliability of communication in future underwater channel environment.

Design and Application of Acrylic Electron Wedge to Improve Dose Inhomogeneities at the Junction of Electron Fields (전자선 조사야 결합부분의 선량분포 개선을 위한 Acrylic Electron Wedge의 제작 및 사용)

  • Kim Young Bum;Kwon Young Ho;Whang Woong Ku;Kim You Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.60-68
    • /
    • 1998
  • Treatment of a large diseased area with electron often requires the use of two or more adjoining fields. In such cases, not only electron beam divergence and lateral scattering but also fields overlapping and separation may lead to significant dose inhomogeneities(${\pm}20\%$) at the field junction area. In this study, we made Acrylic Electron Wedges to improve dose homogeneities(${\pm}5\%$) in these junction areas and considered application it to clinical practices. All measurements were made using 6, 9, 12, 16, 20MeV Electron beams from a linear accelerator for a $10{\times}10cm$ field at 100cm SSD. Adding a 1 mm sheet of acryl gradually from 1 mm to 15 mm, We acquired central axis depth dose beam profile and isodose curves in water phantom. As a result, for all energies, the practical range was reduced by approximately the same distance as the thickness of the acryl insert, e.g. a 1 mm thick acryl insert reduce the practical range by approximately 1 mm. For every mm thickness of acryl inserted, the beam energy was reduced by approximately 0.2MeV. These effects were almost independent of beam energy and field size. The use of Acrylic Electron Wedges produced a small increase $(less\;than\;3\%)\;in\;the\;surface\;dose\;and\;a\;small\;Increase(less\;than\;1\%)$ in X-ray contamination. For acryl inserts, thickness of 3 mm or greater, the penumbra width increased nearly linear for all energies and isodose curves near the beam edge were nearly parallel with the incident beam direction, and penumbra width was $35\;mm{\sim}40\;mm$. We decide heel thickness and angle of the wedge at this point. These data provide the information necessary to design Acrylic Electron Wedge which can be use to improve dose uniformity at electron field junctions and it will be effectively applicated in clinical practices.

  • PDF