• Title/Summary/Keyword: separation

Search Result 11,235, Processing Time 0.041 seconds

Stage Separation Analysis of Launch Vehicle Using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 발사체 단 분리 운동 분석)

  • Oh, Choong-Seok;Sun, Byung-Chan;Park, Yong-Kyu;Roh, Woong-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.4
    • /
    • pp.341-348
    • /
    • 2015
  • This paper addresses Monte-Carlo simulation analyses for the stage separation of the general launch vehicle. The stage separation event of the launch vehicle occurs during a very short time and is related with many dynamic parameters. The stage separation is a critical event in that the launch fails if there is a collision during the stage separation. The stage separation analyses was conducted for the general launch vehicle to confirm the separation without collision within the designed clearance in case of the random input parameters. This paper presents the stochastic results of the stage separation of the launch vehicle using the Monte-Carlo simulation.

Separation of Mixed Plastics using the Drum type Tribo-Electrostatic Separation Process (드럼형 마찰대전장치를 이용한 혼합플라스틱의 정전선별)

  • Kim Do Kyun;Cho Hee Chan;Jeon Ho Seok
    • Resources Recycling
    • /
    • v.13 no.1
    • /
    • pp.39-46
    • /
    • 2004
  • Triboelectrostatic separation process is a technology that different particles charged after contact and rubbing different materials are separated in a high electric field. This technology has an advantage in that it can be used for separating non-conducting materials such as plastics unlike other electrostatic separation processes. There are two objectives in this study. One is to develop an effective continuous tribo-electrostatic separation process. The other is to apply the developed device for the separation of mixed plastics. Results show that almost all tested plastics reaches over 95% in yield and grade after separation.

Comparison of Pollutant Control in Combined Sewer Overflows and Separated Sewer Overflows using the Separation Wall (우오수분리벽을 이용한 합류식 하수관거와 분류식 우수관거의 월류수 제어효과 비교)

  • Lim, Bong-Su;Kim, Do-Young;Lee, Kuang-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.458-466
    • /
    • 2007
  • This study is to evaluate control effects of separation wall by surveying water quality and sewer overflows during dry and wet periods in combined sewer and separated sewer systems. Ravine water from the combined Seokgyo outfall with the separation wall was separated about four times larger than sewage flow during dry periods. The water quality of the combined Seokgyo outfall with separation wall during dry periods is flow weighed average BOD 61 mg/L, the combined Cheonseokgyo outfall without the separation wall is average BOD 71 mg/L, and the separated Pyeongsong center outfall is average BOD 41 mg/L. The BOD concentration in separated outfall form about 57% of the combined outfall, and this means the separated outfall (i.e. storm sewer) is polluted by inflow of sewage. The overflow load of the separated outfall is ten times higher than the combined outfall and its overflow load per rainfall is three times than combined outfall during the wet periods. Therefore, the control plan of overflow load is required in storm sewer. The control effects of the overflow load increased 79% by setting the separation wall in the combined sewer, and showed 27% increase without the separation wall in separated sewer, but forecasted over 80% increase of effects if the separation wall was set.

Real-time identification of the separated lanthanides by ion-exchange chromatography for no-carrier-added Ho-166 production

  • Aran Kim;Kanghyuk Choi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.69-77
    • /
    • 2021
  • No-carrier-added holmium-166 (n.c.a 166Ho) separation is performed based on the results of separation conditions using stable isotopes dysprosium (Dy) and holmium (Ho) to minimize radioactive waste from separation optimization procedures. Successful separation of two adjacent lanthanides was achieved by cation-exchange chromatography using a sulfonated resin in the H+ form (BP-800) and α-hydroxyisobutyric acid (α-HIBA) as eluent. For the identification process after separation of stable isotopes, the use of chromogenic reagents alternatively enables on-line detection because the lanthanides are hardly absorb light in the UV-vis region or exhibit radioactivity. Four different chromogenic reagents were pre-tested to evaluate suitable coloring reagents, of which 4-(2-Pyridylazo)resorcinol is the most recommendable considering the sensitivity and specificity for lanthanides. Lanthanide radioisotopes (RI) were monitored for separation with an RI detector using a lab-made separation LC system. Under the proper separation conditions, the n.c.a 166Ho was effectively obtained from a large amount of 100 mg dysprosium target within 2 hrs.

Study on multi-stage magnetic separation device for paramagnetic materials operated in low magnetic fields

  • F. Mishima;Aoi Nagahama;N. Nomura;S. Nishijima
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.13-17
    • /
    • 2023
  • Magnetic separation technology for small paramagnetic particles has been desired for the volume reduction of contaminated soil from the Fukushima nuclear power plant accident and for the separation of scale and crud from nuclear power plants. However, the magnetic separation for paramagnetic particles requires a superconducting high gradient magnetic separation system applied, hence expanding the bore diameter of the magnets is necessary for mass processing and the initial and running costs would be enormous. The use of high magnetic fields makes safe onsite operation difficult, and there is an industrial need to increase the magnetic separation efficiency for paramagnetic particles in as low a magnetic field as possible. Therefore, we have been developing a magnetic separation system combined with a selection tube, which can separate small paramagnetic particles in a low magnetic field. In the previous technique we developed, a certain range of particle size was classified, and the classified particles were captured by magnetic separation. In this new approach, the fluid control method has been improved in order to the selectively classify particles of various diameters by using a multi-stage selection tube. The soil classification using a multi-stage selection tube was studied by calculation and experiment, and good results were obtained. In this paper, we report the effectiveness of the multi-stage selection tube was examined.

Structural Changes of PVDF Membranes by Phase Separation Control (상분리 조절에 의한 PVDF막의 구조 변화)

  • Lee, Semin;Kim, Sung Soo
    • Korean Chemical Engineering Research
    • /
    • v.54 no.1
    • /
    • pp.57-63
    • /
    • 2016
  • Thermally induced phase separation (TIPS) and nonsolvent induced phase separation (NIPS) were simultaneously induced for the preparation of flat PVDF membranes. N-methyl-2-pyrrolidone (NMP) was used as a solvent and dibutyl-phthlate (DBP) was used as a diluent for PVDF. When PVDF was melt blended with NMP and DBP, crystallization temperature was lowered for TIPS and unstable region was expanded for NIPS. Ratio of solvent to diluent changed the phase separation mechanism to obtain the various membrane structures. Contact mode of dope solution with nonsolvent determined the dominant phase separation behavior. Since heat transfer rate was greater than mass transfer rate, surface structure was formed by NIPS and inner structure was by TIPS. Quenching temperature of dope solution also affected the phase separation mechanism and phase separation rate to result in the variation of structure.

Hospital Financial Performances and Separation of Dispensary from Medical Practice (의약분업 전후 병원 재무성과의 변화)

  • Jung, Kyu-Eon;Ju, Jeong-Bun;Kim, Young-Kyu
    • Korea Journal of Hospital Management
    • /
    • v.9 no.3
    • /
    • pp.49-70
    • /
    • 2004
  • This study analyzes the effect of separation of dispensary from medical practice on hospital management performance. The results are as follow. The earning ratios of large size hospitals become deteriorated significantly after the separation of dispensary. The growth ratios of revenues from inpatient were unchanged, but the growth ratios of revenues from outpatient of large and middle size hospitals were decreased significantly. Hospitals can't sell the medicines to the outpatient after the separation of dispensary, but they can do to the outpatient. The labor cost ratios of small and large size hospitals are increased significantly after the separation of dispensary. There are two reasons for increase of labor cost ratios. One is the decrease of material cost ratio. The other is the increase of doctor's salary. The material cost ratios of every size hospital are decreased significantly after the separation of dispensary. Because medicines costs of outpatients are decreased. The labor cost and doctors' salary per patient of middle and large size hospitals are increased significantly after the separation of dispensary. And average treatment fees per day of inpatients of middle and large size hospitals are increased significantly after the separation of dispensary. But those of outpatients are decreased significantly. Average numbers of outpatients per bed of small and large hospitals are decreased significantly after the separation of dispensary. And average numbers of inpatients per bed of large hospitals are decreased significantly. In summary, as a consequence of separation of dispensary from medical practice, management performances of large size hospitals become deteriorated significantly.

  • PDF

Applications and a View of Gas Separation by Membranes in Japan (일본에서의 기체분리막의 현황 및 응용)

  • Nakagawa, Tsutomu
    • Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.9-29
    • /
    • 1994
  • The development of separation technology is an important research subject as is clear from its role in the Japanese government's research and development program for basic technology for the next generation(1981~1990). Japan is poor not only in mineral resources but also in energy resources and if a sudden change occurs in oil producing facility or an accident occurs in a nuclear power plant, then energy policy must undergo changes and economic foundations may collapse. Japan has already experienced this. Although, oil prices are stable at present and Japan can import oil at low cost due to the yen appreciation, Japan needs to promote development work for any new energy crisis that may come in the future. This has been the motive for gas separation membrane development in Japan. The study of gas permeation through polymer membranes, which is the basis for membranes for gas separation, at Japanese universities began many years ago, but interest in membranes for gas separation was aroused mainly by the Government. The development of gas separation membranes in Japan started with membranes for oxygen separation on an industrial scale.

  • PDF

Superconducting high gradient magnetic separation for magnetic substance at sludge powder of hot rolled coolant

  • Kwon, Jun-Mo;Ha, Dong-Woo;Kim, Tae-Hyung;Cho, Mun-Dak;Choi, Woo-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.353-353
    • /
    • 2009
  • It is an important task to construct a recycling society with a low damage on the environment in our century. Magnetic separation is expected to be applied for the industrial waste treatment as an important supporting technology. In the magnetic separation of dry condition, the cohesive force between particles is strong compared with that in the wet condition's magnetic separation. The use of high magnetic field by the superconducting magnet enhances the powder's magnetic substance capture ability of the magnetic separation. In this study, the POSCO's coolant sludge of hot rolled steel was used for the superconducting magnetic separation of dry condition. Cryo-cooled NB-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator.

  • PDF

An Introduction to Energy-Based Blind Separating Algorithm for Speech Signals

  • Mahdikhani, Mahdi;Kahaei, Mohammad Hossein
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.175-178
    • /
    • 2014
  • We introduce the Energy-Based Blind Separating (EBS) algorithm for extremely fast separation of mixed speech signals without loss of quality, which is performed in two stages: iterative-form separation and closed-form separation. This algorithm significantly improves the separation speed simply due to incorporating only some specific frequency bins into computations. Simulation results show that, on average, the proposed algorithm is 43 times faster than the independent component analysis (ICA) for speech signals, while preserving the separation quality. Also, it outperforms the fast independent component analysis (FastICA), the joint approximate diagonalization of eigenmatrices (JADE), and the second-order blind identification (SOBI) algorithm in terms of separation quality.