Characterization of Electrical Crosstalk in 1.25 Gbps Optoelectrical Triplex Transceiver Module for Ethernet Passive Optical Networks (이더넷 광 네트워크 구현을 위한 1.25 Gbps 광전 트라이플렉스 트랜시버 모듈의 전기적 혼신의 분석)

  • Kim Sung-Il;Lee Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.3 s.333
    • /
    • pp.25-34
    • /
    • 2005
  • In this paper, we analyzed and measured the electrical crosstalk characteristics of a triplex transceiver module for ethernet Passive optical networks(EPONS). And we improved the electrical crosstalk levels using Dummy ground lines with signal lines. The triplex transceiver module consists of a laser diode as a transmitter, a digital photodetector as a digital data receiver, and a analog photodetector as a community antenna television signal receiver. And there are integrated on silicon substrate. The digital receiver and analog receiver sensitivity have to meet -24 dBm at $BER=10^{-l2}$ and -7.7 dBm at 44 dB SNR. And the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysis and measurement results, the proposed silicon substrate structure that contains the Dummy ground line with $100\;{\mu}m$ space from signal lines and separates 4 mm among devices respectively, is satisfied the electrical crosstalk level compared to simple structure. This proposed structure can be easily implemented with design convenience and greatly reduced the silicon substrate size about $50\%$.

Refinement of damage identification capability of neural network techniques in application to a suspension bridge

  • Wang, J.Y.;Ni, Y.Q.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.1
    • /
    • pp.77-93
    • /
    • 2015
  • The idea of using measured dynamic characteristics for damage detection is attractive because it allows for a global evaluation of the structural health and condition. However, vibration-based damage detection for complex structures such as long-span cable-supported bridges still remains a challenge. As a suspension or cable-stayed bridge involves in general thousands of structural components, the conventional damage detection methods based on model updating and/or parameter identification might result in ill-conditioning and non-uniqueness in the solution of inverse problems. Alternatively, methods that utilize, to the utmost extent, information from forward problems and avoid direct solution to inverse problems would be more suitable for vibration-based damage detection of long-span cable-supported bridges. The auto-associative neural network (ANN) technique and the probabilistic neural network (PNN) technique, that both eschew inverse problems, have been proposed for identifying and locating damage in suspension and cable-stayed bridges. Without the help of a structural model, ANNs with appropriate configuration can be trained using only the measured modal frequencies from healthy structure under varying environmental conditions, and a new set of modal frequency data acquired from an unknown state of the structure is then fed into the trained ANNs for damage presence identification. With the help of a structural model, PNNs can be configured using the relative changes of modal frequencies before and after damage by assuming damage at different locations, and then the measured modal frequencies from the structure can be presented to locate the damage. However, such formulated ANNs and PNNs may still be incompetent to identify damage occurring at the deck members of a cable-supported bridge because of very low modal sensitivity to the damage. The present study endeavors to enhance the damage identification capability of ANNs and PNNs when being applied for identification of damage incurred at deck members. Effort is first made to construct combined modal parameters which are synthesized from measured modal frequencies and modal shape components to train ANNs for damage alarming. With the purpose of improving identification accuracy, effort is then made to configure PNNs for damage localization by adapting the smoothing parameter in the Bayesian classifier to different values for different pattern classes. The performance of the ANNs with their input being modal frequencies and the combined modal parameters respectively and the PNNs with constant and adaptive smoothing parameters respectively is evaluated through simulation studies of identifying damage inflicted on different deck members of the double-deck suspension Tsing Ma Bridge.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

Gravity monitoring of $CO_2$ storage in a depleted gas filed: A sensitivity study (채굴후 가스전내 $CO_2$ 저장소의 중력 모너터링: 감도 연구)

  • Sherlock, Don;Toomey, Aoife;Hoversten, Mike;Gasperikova, Erika;Dodds, Kevin
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2006
  • In 2006, the Cooperative Research Centre for Greenhouse Gas Technologies (CO2CRC) plans to undertake (subject to receiving the necessary approvals) a Pilot program for $CO_2$ storage within a depleted gas reservoir. The Otway Basin Pilot Program (OBPP) aims to demonstrate that subsurface $CO_2$ storage is both economically and environmentally sustainable in Australia. This will be the first $CO_2$ storage program in the world to utilise a depleted gas reservoir and, hence, the experience gained will be a valuable addition to the range of international $CO_2$ storage programs that are underway or being planned. A key component of the OBPP is the design of an appropriate geophysical monitoring strategy that will allow the subsurface migration of the $CO_2$ plume to be tracked and to verify that containment has been successful. This paper presents the results from modelling the predicted gravity response to $CO_2$ injection into the Otway Basin reservoir, where the goal was to determine minimum volumes of $CO_2$ that may be detectable using non-seismic geophysical techniques. Modelling results indicate that gravity measurements at 10 m spacing within the existing observation well and the planned $CO_2$ injection well would provide excellent vertical resolution, even for the smallest $CO_2$ volume modelled (10000 tonnes), but resolving the lateral extent of the plume would not be possible without additional wells at closer spacing.

Dynamic Deformation Properties of Coarse Granular Materials with Respect to Gradation Characteristics (조립재료의 입도특성에 따른 동적 변형특성 평가)

  • Ha, Ik-Soo;Kim, Nam-Ryong
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.5-14
    • /
    • 2013
  • Coarse granular geomaterials containing large gravels are broadly used for construction of large geotechnical systems such as dams, levees, railways and backfills. It is necessary to evaluate deformation characteristics of these materials for dynamic analysis, e.g. seismic design. This study presents evaluation of dynamic deformation characteristics of coarse materials using large scale resonant column testing apparatus, which uses specimens with 200 mm in diameter and 400 mm in height, and the effects of gradation characteristics on maximum shear modulus, shear modulus reduction curve and damping characteristics were investigated. From experimental study using rock-fill materials for a dam, we could see that the largest or mean particle size affects the shape of shear modulus reduction curve. When the specimens are prepared under the same conditions for maximum particle size, the coefficient of uniformity affects the confining stress exponent of maximum shear modulus. It could be concluded that the maximum particle size is an factor which affects shear modulus reduction curve, and that the coefficient of uniformity is for small strain shear modulus, especially for the sensitivity to confining stress.

Development of Water Quality Management System in Daecheong Reservoir Using Geographic Information System (GIS를 이용한 저수지의 수질관리시스템 구축)

  • 한건연;백창현
    • Spatial Information Research
    • /
    • v.12 no.1
    • /
    • pp.13-27
    • /
    • 2004
  • The current industrial development and the increase of population in Daecheong Reservoir basin have produced a rapid increase of wastewater discharge. This has resulted in problem of water quality control and management. Although many efforts have been carried out, reservoir water quality has not significantly improved. In this sense, the development of water quality management system is required to improve reservoir water quality. The goal of this study is to design a GIS-based water quality management system for the scientific water quality control and management in the Daecheong Reservoir. For general water quality analysis, WASP5 model was applied to the Daecheong Reservoir. A sensitivity analysis was made to determine significant parameters and an optimization was made to estimate optimal values. The calibration and verification were performed by using observed water quality data for Daecheong Reservoir. A water quality management system for Daecheong Reservoir was made by connecting the WASP5 model to ArcView. It allows a Windows-based Graphic User Interface(GUI) to implement all operation with regard to water quality analysis. The proposed water quality management system has capability for the on-line data process including water quality simulation, and has a post processor far the reasonable visualization for various output. The modeling system in this study will be an efficient NGIS(National Geographic Information System) far planning of reservoir water quality management.

  • PDF

Research on the Relative Importance and the Priority for the Functions of the U-City Service Aid Organization (U-City 서비스 지원기관 기능의 상대적 중요도와 우선순위 연구)

  • Yi, Mi Sook;Shin, Dong Bin;Lee, Jae Yong
    • Spatial Information Research
    • /
    • v.21 no.2
    • /
    • pp.35-43
    • /
    • 2013
  • The aim of this research is to analyze the priority to functions of the U-city Service Aid Organization(USAO), which is to support invigorating U-City industry. This research analyzes the relative importance and the priority about the functional area and components of UASO based on AHP. This research also performs a sensitivity analysis. The research result shows that relative importance of functional area is like following orders: 1) distribution of U-City service-related information, 2) quality certification of U-City-related products and services, 3) R&D of U-City technology, 4) standardization of U-City, 5) U-City human resource development. The relative importance order of functional components is 1) establishment of U-City information distribution organization, 2) construction and management of U-City information distribution network, 3) supporting U-City information distribution and price policy, 4) providing U-City information list for distribution, 5) preparation and application of quality certification standard of U-City products and services, 6) research on legal system of U-City items, targets, and procedures for quality certification, 7) research, analysis, and provision of U-City information distribution situation, 8) level examination of constructed infrastructures and services in U-City, 9) U-City core technology development and localization of technology, 10) standardization of collected U-City information, service classification, distribution system. This research result can be applied directly to design functions of USAO. The result also can be used for duty management, human resource planning, or resource allocation.

Detection of Clavibacter michiganensis subsp. michiganensis Assisted by Micro-Raman Spectroscopy under Laboratory Conditions

  • Perez, Moises Roberto Vallejo;Contreras, Hugo Ricardo Navarro;Herrera, Jesus A. Sosa;Avila, Jose Pablo Lara;Tobias, Hugo Magdaleno Ramirez;Martinez, Fernando Diaz-Barriga;Ramirez, Rogelio Flores;Vazquez, Angel Gabriel Rodriguez
    • The Plant Pathology Journal
    • /
    • v.34 no.5
    • /
    • pp.381-392
    • /
    • 2018
  • Clavibacter michiganensis subsp. michiganesis (Cmm) is a quarantine-worthy pest in $M{\acute{e}}xico$. The implementation and validation of new technologies is necessary to reduce the time for bacterial detection in laboratory conditions and Raman spectroscopy is an ambitious technology that has all of the features needed to characterize and identify bacteria. Under controlled conditions a contagion process was induced with Cmm, the disease epidemiology was monitored. Micro-Raman spectroscopy ($532nm\;{\lambda}$ laser) technique was evaluated its performance at assisting on Cmm detection through its characteristic Raman spectrum fingerprint. Our experiment was conducted with tomato plants in a completely randomized block experimental design (13 plants ${\times}$ 4 rows). The Cmm infection was confirmed by 16S rDNA and plants showed symptoms from 48 to 72 h after inoculation, the evolution of the incidence and severity on plant population varied over time and it kept an aggregated spatial pattern. The contagion process reached 79% just 24 days after the epidemic was induced. Micro-Raman spectroscopy proved its speed, efficiency and usefulness as a non-destructive method for the preliminary detection of Cmm. Carotenoid specific bands with wavelengths at 1146 and $1510cm^{-1}$ were the distinguishable markers. Chemometric analyses showed the best performance by the implementation of PCA-LDA supervised classification algorithms applied over Raman spectrum data with 100% of performance in metrics of classifiers (sensitivity, specificity, accuracy, negative and positive predictive value) that allowed us to differentiate Cmm from other endophytic bacteria (Bacillus and Pantoea). The unsupervised KMeans algorithm showed good performance (100, 96, 98, 91 y 100%, respectively).

Design and Fabrication of APD-FET Module for 2.5 Gbps Optical Communicating System (광통신용 APD-FET 광수신모듈 설계 및 제작)

  • 강승구;송민규;윤형진;박경현;박찬용;박형무;윤태열;이창희;심창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.166-172
    • /
    • 1994
  • The fiber optic receiver, ETRI APD-FET 1.0, is developed for the application of optical communication. This fiber optic receiver includes PD sub-module and pre-amplifier case. A single lens system is introduced for the PD sub-module. The sub-module consists of the avalenche photodiode(APD), GRIN rod lens, and a single mode fiber. The above components are enclosed into the stainless steel 304L housings. By bevelling the fiber end, the single mode fiber provides less than ~ 28 dB of optical return loss. The area of image focus is controlled by adjusting the length of spacer located in-between the fiber and the GRIN rod lens. The laser welding technique is applied to achieve the maximum coupling efficiency for the joining of each housing. In the pre-amplifier case, GaAs FET pre-amplifier workes for photocurrent amplification and the thermister is mounted to control the APD bias. The performance of ETRI APD-FET1.0 shows the sensitivity of - 30.3 dBm at $10^{-10}$ BER(bit error rate) and 2.5 Gbps optical random signal of $2^{23}-1$ word length. The fiber optic receiver is one of the essensial parts of the transmission module for B-ISDN. Also, the above optical packaging technology will be adapted for the developement of 10 Gbps transmission application 2.5 Gbps 5 Gbps

  • PDF

Fabrication and Transmission Experiment of the Distributed Feedback Laser Diode(DFB-LD) Module for 2.5Gbps Optical Telecommunication System (2.5Gbps 광통신용 distrbuted feedback laser diode(DFB-LD) 모듈 제작 및 광송신 실험)

  • 박경현;강승구;송민규;이중기;조호성;장동훈;박찬용;김정수;김홍만
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.423-430
    • /
    • 1994
  • We designed and fabricated the single mode fiber pigtailed DFB-LD module for 2.5 Gbps optical communication system. In the design of the DFB-LD module, we made the module divided into two parts of inner sub-module and outer 14-pin butterfly package and cylindrical shaped sub-module contain quasi confocal 2 lens system including optical isolator and electrical connection between these parts via hybrid substrate of bias T circuit. Laser welding was used to assemble the sub-module which requires accurate fixing between optical elements. The fabricated DFB-LD module showed optical coupling efficiency of 20% and - 3 dB small signal response of more than 2.6 GHz. We confirmed mechanical reliability of the module by temperature cycle test where the tested module exhibit optical power fluctuation of less than 10%. Finally we evaluated the performance of the fabricated DFB-LD module as light source of 2.5 Gbps optical communication system, sensitivity of - 30.2 dBm was obtained through 47 km optical fiber transmission under the criterion of $1\times10^{-10}$ BER and transmission penalties were 1.5 dB caused by extinction ratio and 1.0 dB caused by chromatic dispersion of normal single mode fiber. fiber.