• Title/Summary/Keyword: sensitivity

Search Result 18,066, Processing Time 0.04 seconds

Sensitivity Factors of Kitsch Expression in Food and Beverage Space - Focused on The Correlations with Characteristics of Kitsch and Design Methods - (F&B공간에 나타난 키치적 표현의 감성 요소에 관한 연구 - 키치의 특성 및 디자인 기법과의 상관성을 중심으로 -)

  • Won, Da-Hee;Lyu, Ho-Chang
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.5
    • /
    • pp.298-307
    • /
    • 2012
  • Contemporary design of food and beverage(F&B) space reflects various needs, not only of eating, but also environmental ones. As a way of meeting this conceptual change and the various needs of contemporary consumers, kitsch expression is often utilized actively. Thus, this study intends to analyze the design characteristics and methods of kitsch expression found in contemporary F&B space and their correlations with sensitivity factors, focusing on relevant cases. Specifically, it examined the definition, origin, and changes of kitsch, and identified the sensitive role of kitsch in interior space. Next, it classified the kitsch characteristics and design methods found in interior design, finally analyzing the characteristics of kitsch expressions in contemporary F&B space by sensitivity factors and their correlations with design methods. As a consequence, it was found that the attempts in contemporary F&B space design to differentiate space through active introduction of various kitsch expressions were fulfilling the sensitive needs of changing consumers by providing new cultural experiences. That is, such attempts are considered to have improved the satisfaction of consumers who value sensitivity, by means of wide exchange of sensitivity between designers and consumers. To raise the sensitive satisfaction of consumers more in future, it is necessary to further continuous and in-depth research on the correlation between kitsch expressions and sensitivity factors in interior design.

  • PDF

An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump (자동차 연료펌프의 오염민감도 실험 연구)

  • 이재천;장지현;신현명
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

The Effects of Sensitivity on Subjective Responses to Residential Noises (생활소음의 주관적 반응에 대한 민감도의 영향)

  • Ryu, Jong-Kwan;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.363-366
    • /
    • 2005
  • Social survey and auditory experiment on residential noises such as floor impact, air-bome, bathroom, drainage and traffic noises were conducted to investigate the effects of sensitivity and background noise levels on subjective response to residential noises. Results of survey showed that multiple questions for sensitivity to noise have a more power for discrimination against subjective response to noise than single question. It was also found that the correlation between sensitivity and annoyance was relatively low, but the differences in annoyance between sensitivity groups were significant. Result of auditory experiment showed that effects of sensitivity on annoyance were different according to noise type and noise level. It was also shown that the difference in annoyance between the lowest sensitive stoup and the highest sensitive group was significant in low noise level. The effects of background noise on subjective responses to noise was also different according to noise source and noise level, and were significant in low noise level of airborne and drainage noise.

  • PDF

Analysis of a Photonic Crystal Fiber Sensor with Reuleaux Triangle

  • Bing, Pibin;Huang, Shichao;Guo, Xinyue;Zhang, Hongtao;Tan, Lian;Li, Zhongyang;Yao, Jianquan
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.199-203
    • /
    • 2019
  • The characteristics of a photonic crystal fiber sensor with reuleaux triangle are studied by using the finite element method. The wavelength sensitivity of the designed optical fiber sensor is related to the arc radius of the reuleaux triangle. Whether the core area is solid or liquid as well as the refractive index of the liquid core contributes to wavelength sensitivity. The simulation results show that larger arc radius leads to higher sensitivity. The sensitivity can be improved by introducing a liquid core, and higher wavelength sensitivity can be achieved with a lower refractive index liquid core. In addition, the specific channel plated with gold film is polished and then analyte is deposited on the film surface, in which case the position of the resonance peak is the same as that of the complete photonic crystal fiber with three analyte channels being filled with analyte. This means that filling process becomes convenient with equivalent performance of designed sensor. The maximum wavelength sensitivity of the sensor is 10200 nm/RIU and the resolution is $9.8{\times}10^{-6}RIU$.

Midinfrared Refractive-index Sensor with High Sensitivity Based on an Optimized Photonic Crystal Coupled-cavity Waveguide

  • Han, Shengkang;Wu, Hong;Zhang, Hua;Yang, Zhihong
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.444-449
    • /
    • 2021
  • A photonic crystal coupled-cavity waveguide created on silicon-on-insulator is designed to act as a refractive-index-sensing device at midinfrared wavelengths around 4 ㎛. To realize high sensitivity, effort is made to engineer the structural parameters to obtain strong modal confinement, which can enhance the interaction between the resonance modes and the analyzed sample. By adjusting some parameters, including the shape of the cavity, the width of the coupling cavity, and the size of the surrounding dielectric columns, a high-sensitivity refractive-index sensor based on the optimized photonic crystal coupled-cavity waveguide is proposed, and a sensitivity of approximately 2620 nm/RIU obtained. When an analyte is measured in the range of 1.0-1.4, the sensor can always maintain a high sensitivity of greater than 2400 nm/RIU. This work demonstrates the viability of high-sensitivity photonic crystal waveguide devices in the midinfrared band.

Theoretical Analysis and Optimization of Extrinsic Fabry-Perot Interferometer Optical-fiber Humidity-sensor Structures

  • Yin, Xiao Lei;Wang, Ning;Yu, Xiao Dan;Li, Yu Hao;Zhang, Bo;Li, Dai Lin
    • Current Optics and Photonics
    • /
    • v.5 no.6
    • /
    • pp.652-659
    • /
    • 2021
  • The theoretical analysis and optimization of extrinsic Fabry-Perot interferometer (EFPI) opticalfiber humidity sensors are deeply investigated. For a typical dual-cavity structure composed of an optical fiber and a humidity-sensitive membrane (HSM), the changes in refractive index (RI) and initial length are discussed for polymer materials and porous oxide materials when relative humidity (RH) increases. The typical interference spectrum is simulated at different RH using MATLAB. The spectral change caused by changing HSM RI and initial length are simulated simutineously, showing different influences on humidity response. To deeply investigate the influence on RH sensitivity, the typical response sensitivity curves for different HSM lengths and air-cavity lengths are simulated. The results show that the HSM is the vital factor. Short HSM length can improve the sensitivity, but for HSM RI and length the influences on sensitivity are opposite, because of the opposite spectral-shift trend. Deep discussion and an optimization method are provided to solve this problem. According to analysis, an opaque HSM is helpful to improve sensitivity. Furthermore, if using an opaque HSM, a short air cavity and long HSM length can improve the sensor's sensitivity These results provide deep understanding and some ideas for designing and optimizing highly sensitive EFPI fiber humidity sensors.

Engineering Students' Ethical Sensitivity on Artificial Intelligence Robots (공학전공 대학생의 AI 로봇에 대한 윤리적 민감성)

  • Lee, Hyunok;Ko, Yeonjoo
    • Journal of Engineering Education Research
    • /
    • v.25 no.6
    • /
    • pp.23-37
    • /
    • 2022
  • This study evaluated the engineering students' ethical sensitivity to an AI emotion recognition robot scenario and explored its characteristics. For data collection, 54 students (27 majoring in Convergence Electronic Engineering and 27 majoring in Computer Software) were asked to list five factors regarding the AI robot scenario. For the analysis of ethical sensitivity, it was checked whether the students acknowledged the AI ethical principles in the AI robot scenario, such as safety, controllability, fairness, accountability, and transparency. We also categorized students' levels as either informed or naive based on whether or not they infer specific situations and diverse outcomes and feel a responsibility to take action as engineers. As a result, 40.0% of students' responses contained the AI ethical principles. These include safety 57.1%, controllability 10.7%, fairness 20.5%, accountability 11.6%, and transparency 0.0%. More students demonstrated ethical sensitivity at a naive level (76.8%) rather than at the informed level (23.2%). This study has implications for presenting an ethical sensitivity evaluation tool that can be utilized professionally in educational fields and applying it to engineering students to illustrate specific cases with varying levels of ethical sensitivity.

A Relationship between Kinetic Visual Acuity and Contrast Sensitivity (동적시력과 대비감도의 상관관계)

  • Shim, Moon-Sik;Kang, Hye-Sook;Kim, Sang-Hyun;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.225-229
    • /
    • 2014
  • Purpose: The study was to analyze the correlation between kinetic visual acuity (KVA), visual acuity(static visual angle, SVA) and contrast sensitivity. Methods: Ninety-nine undergraduate students studying Ophthalmic Optics were fully corrected by the Topcon CV-3000 Phoropter. The contrast sensitivity was measured for the participants under the photopic condition ($100cd/m^2$) with Vector Vision CSV-1000E at 2.5 meter, while KVA was measured with KOWA AS-4A. The participants were classified into three groups L, M and H depending on the KVA (0.1~0.3, 0.31~0.6 and greater than 0.61, respectively) and were analyzed whether there was the correlation between the contrast sensitivity, visual acuity and refractive error. Results: The KVA was correlated with the contrast sensitivity for 3 cpd (r=0.26), for 6 cpd (r=0.48), for 12 cpd (r=0.38) and 18 cpd (r=0.47). Except for the low frequency of 3 cpd, they all were higher than the one of the SVA and the KVA (r = -0.37). The contrast sensitivity for 3, 6, 12 and 18 cpd was 59.41, 92.22, 38.41 and 14.39 in the group L, respectively. The contrast sensitivity in the group M was 66.03, 108.78, 53.51 and 19.20 and the one in the group H was 70.90, 146.10, 62.90 and 25.33 for 3, 6, 12 and 18 cpd, respectively. Conclusions: The correlation of the contrast sensitivity and the KVA was higher than the one of the contrast sensitivity and the SVA. It can be assumed that the contrast sensitivity will be high if the KVA is high, except for the case for low spatial frequency.

Changes of Contrast Sensitivity with Decreasing Luminance in Photopic Conditions (명소시 상태에서 휘도 감소에 따른 대비감도 변화)

  • Lee, Eun Jin;Yoon, Moon Joo;Kim, Soo-Hyun;Yang, Gye Tak;Jeong, Ju-Hyun;Kim, Hyun Jung;Kim, Hyun Il;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.411-417
    • /
    • 2012
  • Purpose: To investigate changes of contrast sensitivity with decreasing luminance in photopic conditions. Methods: Contrast sensitivities for 63 university students were investigated at 5 different luminance levels using FACT chart. Results: All contrast sensitivities measured were in the normal range. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd between 40 and $10cd/m^2$. From an intersection point of two hypothetical lines related with contrast sensitivity for 6 and 3 cpd, we could evaluated that the peak moved from 6 to 3 cpd at about $25cd/m^2$. When luminance decreases from 120 to $10cd/m^2$, contrast sensitivity loss at 6 cpd was most, while contrast sensitivity at 1.5 cpd changed little. We could evaluate that at luminance of more than $25cd/m^2$ evaluated approximately, contrast sensitivity was high in the following order of spatial frequency: 18< 12<1.5<3<6 cpd, while at luminance of less than about $25cd/m^2$ as follows: 18<12<1.5<6<3 cpd. Contrast sensitivity losses with decreasing luminance were also evaluated using the decrements and decrement rates of contrast sensitivity. The decrement of contrast sensitivity was the greatest at 6 cpd, while the decrement rate was the greatest at 8 cpd. Conclusions: We propose that evaluation methods used in this research may be available as another methods to evaluate the changes of contrast sensitivity.

Preform Design by the Sensitivity Method (민감도법을 이용한 자유단조 공정의 예비성형체 설계)

  • 심현보;노현철;서의권
    • Transactions of Materials Processing
    • /
    • v.10 no.4
    • /
    • pp.294-301
    • /
    • 2001
  • The sensitivity method has been applied to find perform shape that results in the desired shape after foring. As a 2D example, initial shape of specimen for the cylinder shape without barrelling after forging has been found. The method is then applied to various shapes of 3D free forging and initial shapes of the corresponding specimens after forging have been found successfully The sensitivity method is proven to be an effective and accurate tool for the preform design.

  • PDF