• Title/Summary/Keyword: sensing interface

Search Result 343, Processing Time 0.026 seconds

Tracking and Interaction Based on Hybrid Sensing for Virtual Environments

  • Jo, Dongsik;Kim, Yongwan;Cho, Eunji;Kim, Daehwan;Kim, Ki-Hong;Lee, Gil-Haeng
    • ETRI Journal
    • /
    • v.35 no.2
    • /
    • pp.356-359
    • /
    • 2013
  • We present a method for tracking and interaction based on hybrid sensing for virtual environments. The proposed method is applied to motion tracking of whole areas, including the user's occlusion space, for a high-precision interaction. For real-time motion tracking surrounding a user, we estimate each joint position in the human body using a combination of a depth sensor and a wand-type physical user interface, which is necessary to convert gyroscope and acceleration values into positional data. Additionally, we construct virtual contents and evaluate the validity of results related to hybrid sensing-based whole-body tracking of human motion methods used to compensate for the occluded areas.

A wireless impedance analyzer for automated tomographic mapping of a nanoengineered sensing skin

  • Pyo, Sukhoon;Loh, Kenneth J.;Hou, Tsung-Chin;Jarva, Erik;Lynch, Jerome P.
    • Smart Structures and Systems
    • /
    • v.8 no.1
    • /
    • pp.139-155
    • /
    • 2011
  • Polymeric thin-film assemblies whose bulk electrical conductivity and mechanical performance have been enhanced by single-walled carbon nanotubes are proposed for measuring strain and corrosion activity in metallic structural systems. Similar to the dermatological system found in animals, the proposed self-sensing thin-film assembly supports spatial strain and pH sensing via localized changes in electrical conductivity. Specifically, electrical impedance tomography (EIT) is used to create detailed mappings of film conductivity over its complete surface area using electrical measurements taken at the film boundary. While EIT is a powerful means of mapping the sensing skin's spatial response, it requires a data acquisition system capable of taking electrical impedance measurements on a large number of electrodes. A low-cost wireless impedance analyzer is proposed to fully automate EIT data acquisition. The key attribute of the device is a flexible sinusoidal waveform generator capable of generating regulated current signals with frequencies from near-DC to 20 MHz. Furthermore, a multiplexed sensing interface offers 32 addressable channels from which voltage measurements can be made. A wireless interface is included to eliminate the cumbersome wiring often required for data acquisition in a structure. The functionality of the wireless impedance analyzer is illustrated on an experimental setup with the system used for automated acquisition of electrical impedance measurements taken on the boundary of a bio-inspired sensing skin recently proposed for structural health monitoring.

An Amperometric Proton Selective Sensor with an Elliptic Microhole Liquid/Gel Interface for Vitamin-C Quantification

  • Faisal, Shaikh Nayeem;Hossain, Md. Mokarrom;Lee, Hye-Jin
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.121-126
    • /
    • 2010
  • An amperometric ascorbic acid selective sensor utilizing the transfer reaction of proton liberated from the dissociation of ascorbic acid in aqueous solution across an elliptic micro-hole water/organic gel interface is demonstrated. This redox inactive sensing platform offers an alternative way for the detection of ascorbic acid to avoid a fouling effect which is one of the major concerns in redox based sensing systems. The detection principle is simply measuring the current change with respect to the assisted transfer of protons by a proton selective ionophore (e.g., ETH 1778) across the micro-hole interface between the water and the polyvinylchloride-2-nitrophenyloctylether gel phase. The assisted transfer reaction of protons generated from ascorbic acid across the polarized micro-hole interface was first characterized using cyclic voltammetry. An improved sensitivity for the quantitative analysis of ascorbic acid was achieved using differential pulse stripping voltammetry with a linear response ranging from 1 to $100\;{\mu}M$ concentrations of ascorbic acid. As a demonstration, the developed sensor was applied for analyzing the content of vitamin-C in different types of commercial pharmaceutical tablets and syrups, and a satisfactory recovery from these samples were also obtained.

Measurement of relative geomatric errors between mating parts by using an omnidirectional image sensing system (OISSA) (전방향센서(OISSA)를 이용한 조립물체사이의 상대오차의 측정)

  • 김완수;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.820-823
    • /
    • 1996
  • In contrast to parts of relatively simple shapes, it is important to match their cross-sectional shapes during mating parts of complicated shapes. It requires the 2.pi. information along their matching boundary to figure out their relative geometrical shapes. In this paper, we propose a method measuring a misalignment at the interface during mating parts with the complicated shapes by using the omnidirectional image sensing system(OLSSA). Also we carried out experiments in order to prove the method, and the results show the feasibility.

  • PDF

A Study on the Normalized Analysis of Sensitivity Optimization of Evanescent-Field, Integrated-Optic Biosensor based on Planar Optical Waveguide (평면 광도파로 기반의 소산파 집적광학 바이오센서의 감지도 최적화에 관한 정규화 해석에 관한 연구)

  • Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.25-30
    • /
    • 2018
  • Closed-form analytical expressions and 3-dimensional normalized charts for the homogeneous sensing and surface sensing structures are derived to provide the conditions for the maximum sensitivity of integrated-optic biosensors based on evanescent-wave and stepindex planar optical waveguides. The analysis is made for transverse electric (TE) polarization mode, in both cases where the measurand is homogeneously distributed in the cover (namely, homogeneous sensing), and where it is an ultrathin film on the waveguide-cover interface (namely, surface sensing).

Development of Density Measurement Technique Based on Two Point Detectors and Measurement Reliability According to Different Sensing Gaps (두 지점의 지점검지기를 이용한 밀도측정방안 개발 및 측정간격에 따른 신뢰성 분석)

  • Lee, Cheong-Won;Kim, Min-Seong;Park, Jae-Yeong;Lee, Eun-Gyu
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.3
    • /
    • pp.157-167
    • /
    • 2010
  • Density is the most important congestion indicator among the three fundamental flow variables, flow, speed and density. Measuring density in the field has two different ways, direct and indirect. Taking photos with wide views is one of direct ways, which is not widely used because of its cost and lacking of proper positions. Another direct density measuring method using two point detectors has been introduced with the concept of instantaneous density, average density and measurement interval. The relationship between accuracy and measurement interval has been investigated using the SIMULATION data produced by Paramics Application Programming Interface function. We analyze the affect of segment density accuracy by sensing gap each road condition such as sensing segment length, lane and LOS after gathering data by Paramics Application Programming Interface.

Tactile Sensing for Virtual Interaction as a Part of Ubiquitous Game Development (유비쿼터스게임의 상호작용 구성요소 개발을 위한 촉각응용)

  • Lee, Young-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1062-1068
    • /
    • 2007
  • In order to design and develop a ubiquitous game, it is necessary to develop a natural and flexible interface between the real world and the virtual world, based on social and physical context awareness. We design user interface model and the tactile sensing system that performs virtual interaction and collection of the sensor data. It is sensitive so the collected data should be filtered, rearranged and analyzed. This information is quite different from stylus input, keyboard, button or mouse for interaction. We detect kicked 3D force position of a ball, moment of area, moment of inertia and modified ball shape using tactile sensing system and analyzed data. The results demonstrate that the proposed approach is desirable and robust as well as the results can be used realistic actions and reactions considering attack force and to make interesting environments for ubiquitous game.

Realization of a two dimensional Haptic Interfacing Apparatus for Virtual Object Recognition Experiments (가상물체 인식 실험을 위한 2차원 Haptic 인터페이스 장치의 구현)

  • Lee, Joon-Cheol;Jang, Tae-Jeong
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.415-421
    • /
    • 1999
  • In this paper, a 2D X-Y table, two axes of which are symmetrical, and a force sensing device are constructed, which comprise a 2D haptic interfacing apparatus. Two DC motors are used for actuating the two axes of the table and two precision encoders for sensing the position of each axis. Four PZTs are used for sensing the direction and the magnitude of the 2D force applied to the force sensing device by the user. The performance of the 2D haptic interface device is tested by 2D virtual object recognition experiments.

  • PDF

Impact of a New Formula on the Fresnel Reflectance on Microwave Remote Sensing

  • Qing, Xu;Yuguang, Liu
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1340-1342
    • /
    • 2003
  • In microwave remote sensing, the Fresnel reflectance formula is widely used in the sea surface emissivity modeling. As an essential contribution to microwave remote sensing, a new formula on the Fresnel reflectance has been derived based on our understanding of the complex index of refraction and continuity condition of E-M waves at the interface between two mediums. The proposed formula can be used to obtain the emissivity of sea surface, which is useful to retrieve sea surface temperature, sea surface salinity and the brightness temperature. Considering Bragg-resonant scatter, it is useful for the calculation of the normalized radar cross-section, and the retrieval of sea surface wind either.

  • PDF

Development of ESAD with Flight Environment Sensing Function and Sled Test Method for Function Verification (비행환경 감지 기능을 보유한 ESAD 개발 및 기능 확인을 위한 슬레드 시험 방안)

  • Hanseong Jo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.273-280
    • /
    • 2023
  • Recently electronic safety and arming device(ESAD) has attracted increasing attention due to its design flexibility. However, ESAD can be armed unintentionally due to a malfunction of an external device or interface. Thus ESAD needs an internally generated arming signal independent from the external device. In this paper, a new sensor-hybrid ESAD(SHESAD) with a flight environment sensing function for generating arming signal internally is proposed and a sled test based method is also suggested for evaluating its functions. Through the test results, the operability of the flight environment sensing function was confirmed. Also, it is shown that the proposed test method is suitable for verification of ESAD with the flight environment sensing function.