• 제목/요약/키워드: sensible temperature

검색결과 224건 처리시간 0.031초

Tropical Night (Nocturnal Thermal High) in the Mountainous Coastal City

  • Choi, Hyo
    • 한국환경과학회지
    • /
    • 제13권11호
    • /
    • pp.965-985
    • /
    • 2004
  • The investigation of driving mechanism for the formation of tropical night in the coastal region, defined as persistent high air temperature over than 25$^{\circ}C$ at night was carried out from August 14 through 15, 1995. Convective boundary layer (CBL) of a 1 km depth with big turbulent vertical diffusion coefficients is developed over the ground surface of the inland basin in the west of the mountain and near the top of the mountain, while a depth of thermal internal boundary layer (TIBL) like CBL shrunken by relatively cool sea breeze starting at 100 km off the eastern sea is less than 150 m from the coast along the eastern slope of the mountain. The TIBL extends up to the height of 1500 m parallel to upslope wind combined with valley wind and easterly sea breeze from the sea. As sensible heat flux convergences between the surface and lower atmosphere both at the top of mountain and the inland coast are much greater than on the coastal sea, sensible heat flux should be accumulated inside both the TIBL and the CBL near the mountain top and then, accumulated sensible heat flux under the influence of sea breeze circulation combined with easterly sea breeze from sea to inland and uplifted valley wind from inland to the mountain top returning down toward the eastern coastal sea surface should be transported into the coast, resulting in high air temperatures near the coastal inland. Under nighttime cooling of ground surface after sunset, mountain wind causes the daytime existed westerly wind to be an intensified westerly downslope wind and land breeze further induces it to be strong offshore wind. No sensible heat flux divergence or very small flux divergence occurs in the coast, but the flux divergences are much greater on the top of the mountain and along its eastern slope than on the coastal inland and sea surfaces. Thus, less cooling down of the coastal surface than the mountain surface and sensible heat transfer from warm pool over the coast into the coastal surface produce nocturnal high air temperature on the coastal inland surfaces, which is not much changed from daytime ones, resulting in the persistence of tropical night (nocturnal thermal high) until the early in the morning.

낙동강 수계 중의 댐 건설에 의한 주변의 국지기상환경 변화 -II. 수치모델을 이용한 추정- (A change of local meteorological environment according to dam construction of Nakdong-River -II. Estimation using numerical model-)

  • 전병일;이영미
    • 한국환경과학회지
    • /
    • 제11권4호
    • /
    • pp.281-288
    • /
    • 2002
  • This study was carried out for reading the change of local meteorological environment according to dam construction of Nakdong-river using numerical model. The study used PSU/NCAR Mesoscale Model version5(MM5) for inquiring effect of formation of artificial lake after dam construction. The colleague simulated temperature mixing ratio, latent heat flux and sensible heat flux in two cause of existing lake and not. Temperature and mixing ratio in southwest of Andong lake increased because of the air that was warm and moist above the lake moved to southwest due to the northeasterly wind. In the case of existing lake around Andong, latent heat flux increased much in the daytime after sunrise. However, sensible heat flux decreased but it didn't change distinctly in southwest of Andong like the other values.

배기열 회수용 종이 열교환기의 성능에 관한 연구 (A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 유성연;정민호;최재호;권화길;이춘우;이기성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

기상조건이 대중교통수요에 미치는 영향에 관한 연구 (The Effect of Weather Conditions on Transit Ridership)

  • 최상기;이종호;오승훈
    • 대한토목학회논문집
    • /
    • 제33권6호
    • /
    • pp.2447-2453
    • /
    • 2013
  • 본 연구에서는 강우, 불쾌지수, 강설, 체감온도 등 4가지 기상조건이 대중교통수요에 어떤 영향을 미치는지 관련 통계자료를 이용해 분석을 실시하고, 설문조사를 통해 그 이유를 도출하였다. 모든 자료는 일단위로 수집하였고, 평일-주말과 여름-겨울로 구분하여 분석을 실시하였다. 분석결과, 샘플수가 부족한 강설을 제외하고는 강우, 불쾌지수, 체감온도의 기상조건이 대중교통 수요를 약 2~7% 감소시키는 것으로 나타났다. 수요의 감소폭이 통계적으로 유의한지 알아보기 위해 t-검정을 실시하였는데, 이중 강우와 체감온도가 통계적으로 유의하다는 결과를 얻었다. 상관분석 결과도 강우와 체감온도 2가지 지표가 상대적으로 높은 상관관계를 나타냈으며, 야외에 노출되어있는 버스가 지하철에 비해 높은 상관관계를 보였다. 그리고 통계적으로 유의한 결과가 나온 강우와 체감온도, 2가지 지표에 관한 설문을 실시하였다. 수도권에 거주하는 일반시민을 대상으로 설문을 실시한 결과, 평상시에 응답자 중 약 50%가 버스를 이용하였는데, 이중 강우가 발생하거나 체감온도가 낮아지면 버스 이용이 약 30%대로 감소되는 반면, 승용차와 지하철통행은 약 10% 증가되는 것으로 분석되었다. 본 연구 결과는 기후변화에 따른 대중교통정책 및 운영방법 결정에 기초자료로 사용되어질 수 있을 것으로 기대된다.

다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅰ) - 환기측과 외기측의 풍량 변화에 대하여 - (Study on the Performance of Total Heat Exchanger with Rotating Porous Plates)

  • 조동현;임태우
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.11-17
    • /
    • 2005
  • This paper reports an experimental study on the performance evaluation of air-to-air heat exchanger with rotary type newly developed in this study. Air flow rate is varied from 10 to 120 m3/h. The range of RPM of the porous rotating discs mounted inside the heat exchanger unit is 0 to 50. The temperature of the return air side is set by adjusting heat supply at heater. The material of the porous rotating discs is cooper and its thickness is 1.0 mm. The heat transfer rate increased with the increase in air flow rate. It was found that the heat transfer rate, as the temperature of the return air side was increased, was improved due to higher temperature difference. The heat exchange performance increased with the increase in the temperature of the return air side at the conditions of the same RPM. The sensible heat exchange efficiency was maximum 68 to 76 percent, and enthalpy exchange efficiency 64 to 74 percent.

  • PDF

Three-dimensional Numerical Prediction on the Evolution of Nocturnal Thermal High (Tropical Night) in a Basin

  • Choi, Hyo;Kim, Jeong-Woo
    • International Union of Geodesy and Geophysics Korean Journal of Geophysical Research
    • /
    • 제25권1호
    • /
    • pp.57-81
    • /
    • 1997
  • Numerical prediction of nocturnal thermal high in summer of the 1995 near Taegu city located in a basin has been carried out by a non-hydrostatic numerical model over complex terrain through one-way double nesting technique in the Z following coordinate system. Under the prevailing westerly winds, vertical turbulent fluxes of momentum and heat over mountains for daytime hours are quite strong with a large magnitude of more than $120W/\textrm{m}^2$, but a small one of $5W/\textrm{m}^2$ at the surface of the basin. Convective boundary layer (CBL) is developed with a thickness of about 600m over the ground in the lee side of Mt. Hyungje, and extends to the edge of inland at the interface of land sea in the east. Sensible heat flux near the surface of the top of the mountain is $50W/\textrm{m}^2$, but its flux in the basin is almost zero. Convergence of sensible heat flux occurs from the ground surface toward the atmosphere in the lower layer, causing the layer over the mountain to be warmed up, but no convergance of the flux over the basin results from the significant mixing of air within the CBL. As horizontal transport of sensible heat flux from the top of the mountain toward over the basin results in the continuous accumulation of heat with time, enhancing air temperature at the surface of the basin, especially Taegu city to be higher than $39.3^{\circ}C$. Since latent heat fluxes are $270W/\textrm{m}^2$ near the top of the mountain and $300W/\textrm{m}^2$ along the slope of the mountain and the basin, evaporation of water vapor from the surface of the basin is much higher than one from the mountain and then, horizontal transport of latent heat flux is from the basin toward the mountain, showing relative humidity of 65 to 75% over the mountain to be much greater than 50% to 55% in the basin. At night, sensible heat fluxes have negative values of $-120W/\textrm{m}^2$ along the slope near the top of the mountain and $-50W/\textrm{m}^2$ at the surface of the basin, which indicate gain of heat from the lower atmosphere. Nighttime radiative cooling produces a shallow nocturnal surface inversion layer with a thickness of about 100m, which is much lower than common surface inversion layer, and lifts extremely heated air masses for daytime hours, namely, a warm pool of $34^{\circ}C$ to be isolated over the ground surface in the basin. As heat transfer from the warm pool in the lower atmosphere toward the ground of the basin occurs, the air near the surface of the basin does not much cool down, resulting in the persistence of high temperature at night, called nocturnal thermal high or tropical night. High relative humidity of 75% is found at the surface of the basin under the moderate wind, while slightly low relative humidity of 60% is along the eastern slope of the high mountain, due to adiabatic heating by the srong downslope wind. Air temperature near the surface of the basin with high moisture in the evening does not get lower than that during the day and the high temperature produces nocturnal warming situation.

  • PDF

Characteristics of Thermal Performance on the Different Ambient Air Temperatures of Green Roof Plants

  • Han, Seung Won;Park, Joon Sung;Kim, Jae Soon;Jeong, Myung Il
    • 환경생물
    • /
    • 제34권4호
    • /
    • pp.272-280
    • /
    • 2016
  • Changes in land use and increase in urban energy consumption influence urban life. This study analyzed the characteristics and patterns of urban heat and presents management schemes to generate a comfortable and sustainable urban environment. The study aimed to demonstrate the positive effects of artificial ground greening on improving the microclimate through evapotranspiration using perennial herbs. We have designed a chamber that could control constant temperature and humidity, measure temperature reductions in each plant and changes in sensible heat and latent heat. This study identified Sedum kamtschaticum as the most effective plant in controlling temperature. At $22^{\circ}C$, $3.2^{\circ}C$ temperature reduction was observed, whereas four other plants showed a $1.5^{\circ}C$ reduction. At $25^{\circ}C$, $2.0^{\circ}C$ temperature reduction was observed. On the other hand, the use of Sedum sarmentosum resulted in the lowest effect. Zoysia japonica is the most commonly used ground covering plant, although the temperature reduction of Lysimachia nummularia was more effective at high temperature conditions. Sensible heat and latent heat were calculated to evaluate the thermal performance of energy. At a temperature >$30^{\circ}C$, L. nummularia and S. sarmentosum emitted high latent heat. In this study, we analyzed the thermal performance of green roof perennial plants; in particular, we analyzed the evapotranspiration and temperature reduction of each plant. Since the substrate depth and types, plant species, and seasonal change may influence temperature reduction and latent heat of green roofs, further studies are necessary.

대규모 주택단지내의 인공구조물에 의한 승온화효과에 관한 연구 (On the Warming Effects due to Artificial Constructions in a Large Housing Complex)

  • 김해동;이송옥;구현숙
    • 한국환경과학회지
    • /
    • 제12권7호
    • /
    • pp.705-713
    • /
    • 2003
  • In mid-August 2002, under clear summer pressure patterns, we carried out an intensive meteorological observation to examine the warming effects due to artificial constructions in a large housing complex. We set an automatic weather system(AWS) at two places in a bare soil surface within a limited development district and an asphalt surface within a large apartment residence area, respectively. As a result of observation, it became clear that the difference of the surface air(ground) temperature between the bare soil surface and its peripheral asphalt area reached about 4$^{\circ}C$(13$^{\circ}C$) at the maximum from diurnal variation of surface temperatures on AWS data. Through the heat balance analysis using measurement data, it became clear that the thermal conditions at two places are dependent on the properties of surface material. The latent heat flux over the bare soil surface reached to about 300 W/㎡, which is more than a half of net radiation during the daytime. On the other hand, it was nearly zero over the asphalt surface. Hence, the sensible heat flux over the asphalt surface was far more than that of the bare soil surface. The sensible heat flux over the asphalt surface showed about 20∼30 W/㎡ during the night. It was released from asphalt surface which have far more heat capacity than that of bare soil surface.

다양한 지표면 위에서 총체 전달 방법에 의한 대기 난류 플럭스 추정 (Estimation of Atmospheric Turbulent Fluxes by the Bulk Transfer Method over Various Surface)

  • 김민성;권병혁;강동환
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1199-1211
    • /
    • 2014
  • The momentum flux and the sensible heat flux were measured with the scintillometers and ultrasonic anemometers at 6 sites of which surface characteristics like roughness length and zero-displacement are different each other. We estimated the momentum flux and the sensible heat flux based on the bulk transfer method with the drag coefficient and the heat transfer coefficient calculated from the temperature and wind speed at two heights. The variation of bulk transfer coefficients showed a remarkable difference depending on the atmospheric stability which is less influenced by the zero-displacement than the roughness length. The estimated sensible heat fluxes were in good agreement with those measured at 3 m, showing 23.7 $Wm^{-2}$ of the root mean square error that is less than 10% of its maximum. Since the estimated momentum flux is not only effected by drag coefficient but also by wind speed square, the determination of wind speed in the bulk transfer method is critical.

Estimates of Latent Heat and Sensible Heat Fluxes using Satellite data

  • Kim, Young-Seup;Jang, Jae-Dong;Chung, Hyo-Sang;Cha, Joo-Wan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.37-42
    • /
    • 1998
  • Latent and sensible heat fluxes over the global oceans are estimated using SSM/I (Special Sensor Microwave Imager) and AVHRR MCSST (Advanced Very High Resolution Radiometer Multi-Channel Sea Surface Temperature). The heat fluxes are computed from SSM/I wind speeds and surface humidity, the MCSST, and NCEP Reanalysis sea level pressures and 2-m temperatures from 1996 to 1997. The diabatic conditions bulk formula (Kondo, 1975) is used to compute the heat fluxes. To validate, the derived fluxes are compared to the measurements of 3 JMA buoys. The wind speeds and surface humidity derived from SSM/I have accuracies of 1.37m/s and 1.7g/kg, respectively. The heat fluxes were estimated these factors and the standard error of the latent and sensible heat fluxes are 5.53 W/m$^2$ and 3.33 W/m$^2$. The latest El-Nino phenomenon started at the beginning of 1997 and this event was larger than any others. We compare the heat fluxes in 1997 with the fluxes in 1996 and investigate the spatial movement of meteorological factors as well as the heat fluxes associated with El-Nino appearance.

  • PDF