• 제목/요약/키워드: sensible heat

검색결과 332건 처리시간 0.023초

Performance Analysis of Sensible and Latent Energy Recovery System for Thermally Controlled Facility

  • Park, Byung-Kyu;Kim, Moo-Geun;Kim, Geun-Oh
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.17-26
    • /
    • 2001
  • Simulation was conducted using TRNSYS to evaluate the thermal performance of a facility. This facility has a condensing-type heat exchanger which is able to recover the latent energy for the purpose of reducing the heating energy in winter. The boiler and chiller are selected based on the annual peak loads and controlled to maintain the facility at the set temperature of 14~$17^\circ{C}$. Supplied energy by the boiler and recovered energy by the heat exchanger were calculated as a function of number of pass through heat exchanger, kind of fuel and hot water velocity. Simulation results show that about 20% of the total heating load can be recovered by the heat exchanger and the amount of latent heat is increasing with the number of pass. This means that the efficiency of the waste energy recovery system can be increased by using a condensing-type heat exchanger rather than a traditional sensible heat exchanger.

  • PDF

제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우- (Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994)

  • 김해동;양성기
    • 한국환경과학회지
    • /
    • 제4권3호
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF

재생증발식 수냉각기의 냉각성능 해석 (Investigation on the Cooling Characteristics of a Regenerative Evaporation Water Cooler)

  • 최봉수;홍희기;이대영
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.393-401
    • /
    • 2006
  • The regenerative evaporation water cooler is devised and analysed in this study. The regenerative evaporation water cooler is composed of a sensible heat exchanger to cool the incoming air, followed by a latent heat exchanger to cool the water evaporatively with the cooled air flowing out of the sensible heat exchanger. By linearizing psychrometric characteristics, the heat and mass transfer in the regenerative evaporation water cooler is analyzed theoretically. The results show that the water can be cooled down even lower than the wet-bulb temperature of the inlet air. When the inlet air is $32^{\circ}C$ and 20% in relative humidity, and the inlet temperature of the water is $20^{\circ}C$, the regenerative evaporation water cooler provides a larger cooling capacity than the conventional evaporation water cooler if the effectiveness of the latent heat exchanger is higher than 0.6 and that of the sensible heat exchanger is higher than 0.5.

위성 영상을 활용한 두 가지 현열 플럭스 추정 방법 간의 비교 (Comparison of Two Methodsto Estimate Urban Sensible Heat Flux by Using Satellite Images)

  • 김상혁;이동근
    • 환경영향평가
    • /
    • 제31권1호
    • /
    • pp.63-74
    • /
    • 2022
  • 도시 지역의 열 환경을 파악하기 위해 열 플럭스를 추정하고자 하는 연구들이 많이 진행되어 왔다. 현재 다양한 방법을 통해 현열 플럭스가 추정되고 있으나 각 방법 간의 차이를 비교하는 연구는 매우 미흡한 실정이다. 따라서 본 연구는 대표적인 두 가지 현열 플럭스 추정 방법을 통해 동일한 대상지의 현열 플럭스를 추정하고 그 결과를 비교하여 방법 간의 의의와 한계를 확인하고자 하였다. 연구 결과 열수지 방정식 방법을 통해 현열 플럭스를 추정할 경우 해상도면에서 큰 장점을 가지나 도시 지역의 특징 중 하나인 인공열을 반영하지 못해 현열이 과소추정될 수 있음을 확인할 수 있었다. 물리식을 기반으로 추정할 경우 상대적으로 오차가 작고 인공열의 반영이 가능하나, 시간 및 공간 해상도에 있어 한계가 있음을 확인하였다. 두 방법은 인공열이 많이 발생하는 공업지역에서 가장 큰 차이를 나타냈으며 그 차이는 평균 약 135 W/m2, 최대 400 W/m2로 나타났다. 반면 녹지 및 수변공간은 약 20 W/m2로 두 방법 간의 차이가 매우 작은 것을 확인할 수 있었다. 두 방법 간의 결과가 도시 지역에서 유의미한 차이를 보이는 만큼 향후 연구 목적에 맞는 방법을 선택할 필요가 있다.

배기열(排氣熱) 회수용(回收用) 축류(軸流) 회전형(回轉形) 현열교환기(顯熱交換器)의 최적설계(最適設計)에 관한 연구(硏究) (A Study on the Optimum Design of Axial Rotary Sensible Heat Exchanger for the Heat Recovery of Exhaust Gas)

  • 최영돈;박상동;우정선;태춘섭
    • 설비공학논문집
    • /
    • 제3권2호
    • /
    • pp.131-141
    • /
    • 1991
  • A method of optimum design of an axial rotary sensible heat exchanger for the heat recovery of exhaust gas from the air conditioning space was developed in consideration of economics of investment cost and profit according to the installation of heat exchangers. Leakage rate of exhaust gas was calculated and the correlation for the pressure drop due to leakage of exhaust gas was proposed. Heat transfer between the matrix and exhaust and intake gas was analysed to calculate the effectiveness of heat exchanger, which was used for the optimum design of rotary heat exchanger. The results show that optimum rotational speed increases as the length of rotor increases and there exists optimum NTU which maximizes the gain of total cost according to the installation of rotary heat exchanger.

  • PDF

배기열(排氣熱) 회수용(回收用) 평판(平板) - 휜형(形) 밀집형(密集形) 현열(顯熱) 열교환기(熱交換器)의 최적설계(最適設計)에 관한 연구(硏究) (A Study on the Optimum Design of Plate-Fin Compact Sensible Heat Exchanger for the Heat Recovery of Exhaust Gas)

  • 최영돈;박상동;우정선;태춘섭
    • 설비공학논문집
    • /
    • 제2권2호
    • /
    • pp.85-98
    • /
    • 1990
  • Method of optimum design of a compact sensible plate-fin heat exchanger for the heat recovery of exhaust gas from the air conditioning space was developed in consideration of the econamics of investment cost and profit according to the installation of heat exchanges. In the counterflow heat exchanger, the frontal area was fixed and the length of heat exchanger was optimized in order to maximize the net gain according to the setting of the heat exchanger. In the cross flow heat exchanger, the size of the exchanger was also optimized to maximize the net gain.

  • PDF

수평형 지중열교환기의 전열량 변화에 대한 실험적 연구 (A Experimental Study of Horizontal Geothermal Heat Exchanger System about Total Enthalpy Change)

  • 조성우;임병찬
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권4호
    • /
    • pp.1-7
    • /
    • 2014
  • This paper is performed to investigate of cooling effect and total enthalpy variation on EAHES(Earth-to-Air Heat Exchanger System) that is buried 3m depth and 60m length. Using EAHES, the reduction of the sensible heat is obviously but latent heat is showed increased trend. Although the outdoor average latent heat accounts for 53.2% of total enthalpy, latent heat of the exit air from EAHES was raised as 58%. For improving cooling effect of EAHES, it has to considered that how to remove the latent heat from EAHES.

Study on Energy Saving Properties by using City- Water as a Heat Source for Dwellings

  • Chung, Yong-Hyun;Mizuno, Minoro;Simoda, Yoshiyuki;Kum, Jong-Soo;Choi, Kwang-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.168-176
    • /
    • 1998
  • A simulation study was conducted to use city-water which is thermally regulated by unused energy as a heat source for urban dwellings. This study utilized multiple heat pump system using the city-water as a heat source and suggested a method of reducing the heat load of hot water supply. The simulation was done to calculate the energy savings at a dwelling for a year. The relation between the controlled temperature of city-water. and electric energy in all seasons was also investigated. Furthermore, it has been found that the controlled water system can lead to considerable energy savings and decrease environmental load such as sensible waste heat which otherwise would form heat islands.

  • PDF

UHF 센서 탑재 UAV를 이용한 지표층 열 플럭스 산출 (Estimation of Surface Layer Heat Flux Using the UHF Sensor Installed on UAV)

  • 김민성;권병혁;윤홍주
    • 한국전자통신학회논문지
    • /
    • 제13권1호
    • /
    • pp.265-276
    • /
    • 2018
  • 지상에 고정된 기기로 감시하기 어려운 대기 하층의 관측 사각 지역에서 유용한 관측 및 자료 분석 기술을 개발하였다. 상층 기상 관측에 사용되는 UHF 라디오존데를 UAV에 탑재하여 기온과 상대습도의 연직 자료를 원격 수집하여 10 m 기상 타워에서 측정한 자료와 비교하였다. 검증된 연직 분포로부터 외삽된 지표 기온과 총체 전달 방법을 이용하여 대기 안정도 변화에 따른 현열 플럭스를 추정하였다. 지상에서 3차원 초음파 풍속계로 측정한 현열 플럭스와 비교한 결과는 원격탐사로 산출되는 현열 플럭스에 허용되는 오차 범위 30%보다 작은 23% 이내의 오차를 보였다. UAV 관측 현열 플럭스로부터 추정한 대기경계층 고도는 대기 오염 확산 모델에 유용한 자료를 실시간, 경제적으로 제공할 수 있다.

다양한 지표면 위에서 총체 전달 방법에 의한 대기 난류 플럭스 추정 (Estimation of Atmospheric Turbulent Fluxes by the Bulk Transfer Method over Various Surface)

  • 김민성;권병혁;강동환
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1199-1211
    • /
    • 2014
  • The momentum flux and the sensible heat flux were measured with the scintillometers and ultrasonic anemometers at 6 sites of which surface characteristics like roughness length and zero-displacement are different each other. We estimated the momentum flux and the sensible heat flux based on the bulk transfer method with the drag coefficient and the heat transfer coefficient calculated from the temperature and wind speed at two heights. The variation of bulk transfer coefficients showed a remarkable difference depending on the atmospheric stability which is less influenced by the zero-displacement than the roughness length. The estimated sensible heat fluxes were in good agreement with those measured at 3 m, showing 23.7 $Wm^{-2}$ of the root mean square error that is less than 10% of its maximum. Since the estimated momentum flux is not only effected by drag coefficient but also by wind speed square, the determination of wind speed in the bulk transfer method is critical.