• Title/Summary/Keyword: sensible

Search Result 662, Processing Time 0.026 seconds

A Study on the Optimum Design of Axial Rotary Sensible Heat Exchanger for the Heat Recovery of Exhaust Gas (배기열(排氣熱) 회수용(回收用) 축류(軸流) 회전형(回轉形) 현열교환기(顯熱交換器)의 최적설계(最適設計)에 관한 연구(硏究))

  • Choi, Y.D.;Park, S.D.;Woo, J.S.;Tae, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.2
    • /
    • pp.131-141
    • /
    • 1991
  • A method of optimum design of an axial rotary sensible heat exchanger for the heat recovery of exhaust gas from the air conditioning space was developed in consideration of economics of investment cost and profit according to the installation of heat exchangers. Leakage rate of exhaust gas was calculated and the correlation for the pressure drop due to leakage of exhaust gas was proposed. Heat transfer between the matrix and exhaust and intake gas was analysed to calculate the effectiveness of heat exchanger, which was used for the optimum design of rotary heat exchanger. The results show that optimum rotational speed increases as the length of rotor increases and there exists optimum NTU which maximizes the gain of total cost according to the installation of rotary heat exchanger.

  • PDF

Life-Cycle Cost Analysis of Solution Transportation Absorption System (LCC 분석에 의한 상온 에너지수송용 흡수식 냉동기(STA)의 경제성 평가)

  • 오민규;이봉진;홍희기;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.6
    • /
    • pp.506-513
    • /
    • 2004
  • The objective of this paper is to evaluate the economic performance of latent and sensible energy transportation systems. LCC (Life-Cycle Cost) analysis is a practical method and a guideline for evaluating the economic performance of considered systems during the Life-Cycle Period. By comparing the LCC of alternatives, The most ideal alternative is determined which has the lowest LCC. It is concluded that the cost of STA (Solution Transportation Absorption system) can be reduced by 67% to that of sensible energy transportation for study period with 10 km transportation distance.

Film Boiling Heat Transfer Model of Spray Cooling Focusing on Rebound Motion of Droplets (액적의 리바운드 모션에 주목한 분무냉각 막비등 열전달 모델)

  • Kim, Yeung-Chan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1317-1322
    • /
    • 2004
  • In this report, the heat transfer model of spray cooling on hot surface was developed by focusing on the effect of rebound motion of droplets. In the model, it was assumed that droplets rebound repeatedly on the hot surface and heat transfer upon droplet impact is proportional to sensible heat which heats up the droplets to the saturation temperature. In addition, to take account of the contribution of th heat flux upon impact of rebound droplets, it was assumed that the rebound droplets are distributed following the Gaussian distribution from 0 to L, which distance L is determined by maximum flight distance $L_{max}$. Also the calculated results were compared with existing experimental results.

  • PDF

Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994 (제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우-)

  • 김해동;양성기
    • Journal of Environmental Science International
    • /
    • v.4 no.3
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF

DYNAMICS OF OPEN II-RAYS (META PHYSICS) AND CLOSED II-RAYS

  • Oh, Hung-Kuk
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.39-46
    • /
    • 2000
  • The imploded open $\pi$-rays comprise of the space and their diameters are distributed from nearly zero to infinite. The change of the potential energy in the open $\pi$-ray produces an attraction force between them and it is sensible to the geometric shape factor and its frequency. The equivalent principle of general relativity means that in the wave equation its velocity of the force wave is infinite. The change of the state in a open $\pi$-ray(or any force wave) can be transferred to any sensible open $\pi$-ray via space at a finite velocity. Many properties of the light wave can be deduce from the motions of open $\pi$-rays.The nonsteady and steady Schr dinger equations include the dynamics of open $\pi$-rays and closed $\pi$-rays.$\prod$-ray is a tool of entity for constructing physics and metaphysics at the same time.

  • PDF

Effects of Individual Components on the System Performance in a Desiccant Cooling System (제습냉방시스템에서 요소성능이 시스템성능에 미치는 영향)

  • Chang, Young-Soo;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.687-694
    • /
    • 2007
  • Cycle simulation is peformed for two types of the desiccant cooling system incorporating a regenerative evaporative cooler. The cooling capacity and COP are evaluated at various effectiveness values of the regenerative evaporative cooler, the desiccant rotor and the sensible heat exchanger. As either of the effectiveness of the regenerative evaporative cooler or the humidity effectiveness of the desiccant rotor increases, both the cooling capacity and COP increase, but the enthalpy leak ratio gives the opposite effect on the system performance. It is found that COP of cycle A mainly depends on the humidity effectiveness of the desiccant rotor, while for cycle B enthalpy leak ratio of desiccant rotor has the major impact on COP. The effect of the sensible heat exchanger on the cooling capacity is small about 1/10 compared with those of other components.

A Study of the Exfoliative Cytology of the Human Oral Mucosa of Cigarette Smoking (끽연이 구강점막에 미치는 영향에 관한 박리세포학적 연구)

  • 최광식;김종열
    • Journal of Oral Medicine and Pain
    • /
    • v.6 no.1
    • /
    • pp.111-118
    • /
    • 1981
  • The purpose of this study was observing the keratinization of human oral mucosa on smoking & non-smoking persons. The results are as follows : 1. In the oral mucosa of the smoker, it reaveald the increase of keratinization than the non-smoker. 2. The keratinization of the oral mucosa revealed the increase in proportion to the duration of smoking. 3. The keratinization of the oral mucosa increase in proportion to the amounts of smoking. 4. Between the male and the female in smoking, it didn't show the sensible difference in the keratinization of the oral mucosa. 5. Between smoking and non-smoking, there was not a sensible difference in the change of nucleus and cytoplasm of the oral mucosa.

  • PDF

A Study on the Optimum Design of Plate-Fin Compact Sensible Heat Exchanger for the Heat Recovery of Exhaust Gas (배기열(排氣熱) 회수용(回收用) 평판(平板) - 휜형(形) 밀집형(密集形) 현열(顯熱) 열교환기(熱交換器)의 최적설계(最適設計)에 관한 연구(硏究))

  • Choi, Y.D.;Park, S.D.;Woo, J.S.;Tae, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.2
    • /
    • pp.85-98
    • /
    • 1990
  • Method of optimum design of a compact sensible plate-fin heat exchanger for the heat recovery of exhaust gas from the air conditioning space was developed in consideration of the econamics of investment cost and profit according to the installation of heat exchanges. In the counterflow heat exchanger, the frontal area was fixed and the length of heat exchanger was optimized in order to maximize the net gain according to the setting of the heat exchanger. In the cross flow heat exchanger, the size of the exchanger was also optimized to maximize the net gain.

  • PDF

A Study on the Sensitivity Analysis of the Deterministic Sediment Yield Formulas (결정론적 유사량 산정공식의 민감도 분석에 관한 연구)

  • 김성원;고병련;조정석
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.581-590
    • /
    • 1998
  • This st at the development of the adequate sediment yield formulas in Wi-Stream basin ; IHP representative basin in Korea. As a result of applying outstanding sediment yield formulas among the existing formulas, it is analyzed that including the Engelund & Hansen formula, Yang formula is proper to the Wi-Stream basin. And as a result of sensitivity analysis to the sediment parameters it is analyzed that Rijn and Actors & White formula is more sensible than any other formulas which has been applied the velocity and depth among the parameters. Also, Engelund & Hansen and Yang formula is less sensible than any other formulas. In Wi-Stream basin, it is analyzed that Yang and Engelund & Hansen formula is the most suitable sediment yield formula in this study. But because the existing formulas had been developed in foreign countries and applied the foreign natural livers and reservoirs, it makes careful use of Korean alluvial river and hoped that it will be developed the most adequate formula in Wi-Stream basin.

  • PDF

A Study on the fin efficiency of continuous fin - tube heat exchanger, -In the case of sensible heat transfer- (섹터법을 이용한 연속휜-튜브형 열교환기의 휜효율에 관한 연구, -현열 열전달의 경우-)

  • Jung, Hyeong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.5
    • /
    • pp.76-81
    • /
    • 1996
  • In this paper, a calculation method for fin efficiency of continuous fin is introduced. The continuous fin of in-line and staggered arrangement was divided into many sectors and fin efficiencies of each sectors were calculated by assuming that each sectors be the circular fins. To get the converged fin efficiency which is averaged by the each areas, the number of sectors was increased. The results were compared with equivalnet method by varying the aspect ratios in both cases of in-line and staggered tube arrangement and showed some differences of fin efficiencies.

  • PDF